• 제목/요약/키워드: Light Sensitivity

검색결과 613건 처리시간 0.022초

DEVELOPMENT OF CALCULATION METHOD OF SENSITIVITIES FOR LIGHT WATER REACTORS

  • Takeda, Toshikazu;Foad, Basma
    • Nuclear Engineering and Technology
    • /
    • 제45권6호
    • /
    • pp.753-758
    • /
    • 2013
  • A new method of calculating sensitivity coefficients of core characteristics relative to infinite-dilution cross sections has been developed. Conventional sensitivity coefficients are evaluated for the changes of effective cross sections which are dependent on individual models of core and cell. Therefore a correction has been derived to the conventional sensitivity coefficients based on the perturbation theory. The accuracy of the present method has been verified by comparing numerical results of sensitivity coefficients with a reference Monte-Carlo method.

전례공간에서의 빛요소 적용에 대한 계획방안 연구 (A study on the Application Plan of Light Elements in Liturgy Space)

  • 반상철;김기혁
    • 한국산학기술학회논문지
    • /
    • 제17권11호
    • /
    • pp.521-536
    • /
    • 2016
  • 천주교의 경우 예배와 기도가 이루어지는 교회건물의 중심은 전례공간이라고 할 수 있다. 이 전례공간의 조성은 참례자의 감성에 영향을 주고, 이 감성은 믿음과 연결되기 때문에 전례공간에서 감성에 대한 고려는 매우 중요한 계획요소가 된다고 할 것이다. 본 연구에서는 감성요소 중 시각을 통해 심성을 변화시키는 데에 가장 중요한 조건을 '빛'이라고 보고, 신심을 불러일으키는 전례공간을 형성하는 데에 빛의 역할을 강조하고자 하였다. 따라서 전례공간의 전례상 의미와 중요성을 이해하고, 공간적 위상과 역할을 파악하였고, 전례공간에서의 빛의 기능적 감성적 특성을 분석하기 위해 빛의 종류와 특성, 빛의 역할과 조건 등과 감성의 대상으로서의 빛에 대해 자료를 분석 정리하였다. 그리고 전례공간에서의 빛의 사용사례의 분석을 통해 그 효과와 적절성 및 적용의 조건 등을 파악하였다. 본 연구를 통해 성당의 사회적 역할 변화가 이루어지고 있고, 빛의 디자인적 역할 강화와 함께 성당공간의 활용도 제고에 따른 인공조명의 연출적용이 필요하게 됨을 확인하게 되었다. 또한 연구자료의 분석을 통해 적정조도의 기준을 제안할 수 있게 되었다. 이러한 과정을 통해 얻어진 결과를 종합하여 전례공간에의 빛요소 적용에 대한 계획적 방안을 제안하고자 하였다.

광전식감도시험기의 발광부와 수광부 작동원리에 관한 연구 (A Study on the Operating Principle of the Light-emitting and -receiving Part of the Photoelectric Sensitivity Tester)

  • 윤헌주;권성필;김형권;사공성호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.151-154
    • /
    • 2008
  • The advanced technical data collected from home and abroad have properly been analyzed, so that they are useful to improve the photoelectric sensitivity tester. The results of this study have quickly been supplied to the related industry. Our research and development team has verified the response characteristics of the light-emitting and -receiving part of the photoelectric sensitivity tester in order to help the local manufacturer to study, develope and produce their photoelectric detectors.

  • PDF

펜던트형 감성조명 LED 등기구 모듈개발

  • 서동원;김영근;김진사;김금택;최운식;송민종;송명현;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.264-264
    • /
    • 2009
  • The sensitivity lighting of pendant type used Micro-controller AVR, embodiment method for Munsell chromaticity diagram system and adoption method for light source lens respectively. About a plan design of light fixture, LED circuit designed flow chart of circuits and LED driver of organizations in electron device. For used Solidworks soft ware program, LED light source must take a heat shink part and LED light fixture module for sensitivity lighting of pendant type into considerations

  • PDF

자외선조사에 의한 다공질 실리콘 알코올 센서의 감도 개선 (Improvement of Sensitivity in Porous Silicon Alcohol Gas Sensors by UV Light)

  • 김성진;최복길
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.676-680
    • /
    • 1999
  • To do breath alcohol measurement, a sensor is necessary that it can detect low alcohol gas concentration of 0.01% at least. In this work, a capacitance-type alcohol gas sensor using porous silicon layer is developed to measure low alcohol gas concentration. The sensor using porous silicon layer has some sensitivity at room temperature by very large effective surface area, but there is still much room for improvement. In this experiment, we measured the capacitance of the sensor under 254 nm UV light on the porous silicon layer, in which alcohol solution was kept in a flask at 25, 35, and $45^{\circ}C$ by a heater. As the result, the improvement of sensitivity by illuminating UV light was observed. The increasing rate of the capacitance was shown to be double more than those measured under UV-off state. It is supposed that UV light activates response of the oriental and interfacial polarizations which have slow relaxation time for AC field.

  • PDF

영사식 무아레 토포그래피에서 격자 주기에 따른 물체거리와 광원의 위치에 대한 무늬 민감도 변화 (Fringe Sensitivity of Projection Moire Topography Due to Position of Light Source and Object Distance According to Grating Periods)

  • 오현석;주윤제;조재흥
    • 한국광학회지
    • /
    • 제27권2호
    • /
    • pp.67-72
    • /
    • 2016
  • 영사식 무아레 토포그래피에서 실제 물체에 대한 측정오차를 줄이기 위해서는 물체높이에 따른 무늬차수의 변화율인 무늬 민감도에 대한 조사가 필수적이며, 또한 무늬 민감도를 활용을 하면 절대 차수 결정이 매우 편리하고 정확해진다. 영사기를 사용한 영사식 무아레 토포그래피에서 무늬차수를 결정하기 위한 변수는 광원의 위치와 물체의 위치, 격자주기이다. 이 변수들 중에서 광원의 위치를 횡축으로 움직이는 광원 횡축 이동법과 물체를 종축으로 움직인 물체 종축 이동법에 따른 무늬 민감도를 격자주기에 따라 서로 비교하고 이를 분석하였다. 그 결과 광원 횡축 이동법에서 광원과 상검출기 사이의 간격이 클수록 민감도가 높았으나, 물체 종축 이동법에서 물체와 결상렌즈 사이의 거리가 작을수록 민감도가 높았다. 그리고 두 방법에서 격자주기가 작을수록 민감도가 더 높았으며 변수 변화에 따른 무늬 민감도 변화량은 더 컸다.

Reasons for Variation in Sensitivity and Specificity of Visual Inspection with Acetic Acid (VIA) for the Detection of Pre-Cancer and Cancer Lesions of Uterine Cervix

  • Parashari, Aditya;Singh, Veena
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7761-7762
    • /
    • 2013
  • Alternative strategies such as visual inspection of cervix with acetic acid, are real time, economical and easily implemented methods for cervical cancer screening. However, variable sensitivity and specificity have been observed in various community based studies. The possible reasons could include variation in man power training, light source used for visualization, and preparation of diluted (4-5%) acetic acid and its storage. A standardized protocol for training, teaching material (easy to understand in the local language) for trainees, supervision and reinforcement by intermittent and supplementary training to check the quality of their observation, a standard protocol for preparation dilute acetic acid and its storage and a standard good light source (equivalent to day light) are needed to minimize the variation in sensitivity and specificity of VIA in community settings.

색렌즈의 광투과율에 따른 대비감도 변화 (Changes of Contrast Sensitivity According to Light Transmittance of Color Lenses)

  • 이선행;이윤정;조현국
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3427-3433
    • /
    • 2009
  • 본 연구는 착색렌즈의 광투과율에 따른 명소시 대비감도의 변화를 분석하여 색렌즈를 착용할 때 색상에 따른 적절한 광투과율 기준을 제시하고자 하였다. 정상 시기능을 가진 남자 24명과 여자 13명을 대상으로, 광투과율 80~90%, 60~80%, 43~60%, 30~43%로 착색된 4개의 색렌즈(회색, 갈색, 적색, 녹색)를 순서대로 착용시키고 F.A.C.T. 시표를 이용하여 대비감도 검사를 실시하였다. 검사 결과, 광투과율이 감소될수록 대비감도는 감소되었고, 시감도는 갈색이 가장 높고 적색이 가장 낮은 것으로 나타났다. 대비감도 검사결과를 고려한 색상별 권장 광투과율은 갈색, 회색과 녹색 38% 이상, 적색 52% 이상인 것으로 나타났다. 이러한 결과들로 보아 일상생활에서 눈을 보호할 목적으로 색렌즈를 선택할 때 색상과 그 색상에 적절한 광투과율이 고려되어야 한다.

Preliminary study on the visual sensitivity of Oreochromis niloticus using LED light source for the aquaculture development in Uganda

  • Esther Kagoya;Kyoungmi Kang
    • Fisheries and Aquatic Sciences
    • /
    • 제26권8호
    • /
    • pp.514-523
    • /
    • 2023
  • The visible threshold of Oreochromis niloticus responded to high light intensity under short wavelengths, whereas the response to low light intensity under long wavelengths was low, with a minimum visual threshold of 574 nm of LED lights. Movement distance of O. niloticus was dropped at 31℃ and increased abnormally at 37℃ under natural light. Comparing movement distance under red (622 nm) and green (518 nm) lights of LED, movement distance and swimming speed under red and green lights were higher than under natural light. However, the movement distance decreased rapidly at 31℃ under red light and lowest at 33℃ under green light. After that, there was a tendency to adapt to high water temperatures gradually. Consequently, red and green lights may be recommended for O. niloticus's aquaculture because the red and green lights have a positive effect on growth performance, survival rate, and metabolism, as shown in previous studies. It is necessary to control the water temperature below 32℃ because abnormal behavior above 32℃ revealed under red and green LED lights and natural light.

광 루미네슨스 다공질 실리콘을 이용한 새로운 자외선 센서 (A Novel Ultraviolet Sensor using Photoluminescent Porous Silicon)

  • 민남기;고주열;강철구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.444-449
    • /
    • 2001
  • In this paper, a novel ultraviolet sensor is presented based on a photoluminescent porous silicon. Porous silicon layer was formed by chemical etching of surface of pn junction in a $HF(48%)-HNO_3(60%)-H_20$ solution. Incident ultraviolet(UV) light is converted to visible light by photoluminescent porous silicon layer, and then this visible light generates electron-hole pairs in the pn junction, which produces a photocurrent flow through the device. In order to maximize detection efficiency, the peak sensitivity wavelength of the pn junction diode was matched with the peak wavelength of Photoluminescence from porous silicon layer. The porous silicon ultraviolet sensor showed a large output current as UV intensity increases and but very low sensitivity to visible light. The detection sensitivity of porous silicon sensor was calculated as 2.91mA/mW. These results are expected to open up a possibility that the present porous silicon sensor can be used for detecting UV light in a visible background, compared to silicon UV detectors which have an undesirable response to visible light.

  • PDF