• Title/Summary/Keyword: Light Pipe

Search Result 172, Processing Time 0.023 seconds

Evaluation and Application of Prediction Models for the Daylight Performance of a Light-Pipe System (광파이프 시스템의 채광성능 예측모델의 검증 및 적용)

  • Yun, Geun Young;Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The use of natural light has the potential for improving both the energy efficiency and indoor environmental quality in buildings. A light-pipe system can introduce daylight to spaces that would otherwise not be able to benefit from the advantages of daylight penetration. For the light-pipe system to be widely used in Korea, it is important to quantify its daylighting performance with due consideration regarding the effects imposed by the local climate conditions. This paper presents the evaluation results of existing semi-empirical models to predict daylighting performance of a light-pipe system. The evaluation of the existing models was based on the monitoring data obtained from a underground parking lot in which the light-pipe system was installed. Comparisons were made between the predicted and the monitored data obtained from the study. The results indicated that semi-empirical models which was developed using the experimental data obtained under the Korean climatic conditions had a good prediction performance. We also quantified the effects caused by sky conditions, solar altitudes, room dimensions, and the aspect ratio of a light-pipe system on both the daylighting performance of the light-pipe system and the indoor illuminance distributions of the space using the semi-empirical model. Finally, this paper provides the design guideline of the light-pipe system for its application to an underground parking lot space.

Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System (수직형 라이트파이프의 채광성능에 관한 예비평가)

  • Shin, Hae Mi;Park, Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

A Light Pipe Based Recycling Scheme for LED Brightness Enhancement

  • Ouyang, George;Li, Kenneth
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1149-1151
    • /
    • 2007
  • As a follow-up to our previous work we present in this paper some experimental results on LED light recycling. Specifically we demonstrate for the first time that screen brightness can be increased using our light pipe based light recycling scheme for reallife projection display applications.

  • PDF

Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot (지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구)

  • Shin, Ju-Young;Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

Tracepro Simulation Design and Evaluation for the Double Blind Light Pipe Daylighting System (Tracepro를 활용한 이중 블라인드 광파이프 채광 시스템의 블라인드 설계 및 시스템 효율 평가)

  • Kang, Eun-Chul;Lee, Euy-Joon;Yo, Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.515-520
    • /
    • 2012
  • A daylighting system includes three parts; light collector, light transformer and light distributor. A DBLP(Double blind light pipe) daylighting system consists of a double blind light collector, a mirror duct type light transformer and a prism film light pipe distributor. The double blinds for a light collection are used to track the sun's altitude and azimuth movements throughout the day. Behind both sets of blinds is the light transformer, which is based on a rectangular cone shaped light duct. The light transformer was designed to efficiently deliver the light into the light pipe within a 30 degree radial spread for the efficient light into the distributor. In this study, DBLP system efficiency was simulated, evaluated and optimized by Tracepro as a popular ray trace light design simulation program. The results indicated that DBLP system efficiency evaluated a maximum 22.4% in case of Spring/Fall season solar noon time. While the overall average system efficiency in the morning and afternoon is evaluated about 10%.

Design on illumination of structures for lighthouse in Korea

  • Han, Ju-Seop;Yu, Yong-Su;Kim, Jong-Uk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1327-1332
    • /
    • 2014
  • This paper presents information about the examples of the design on Illumination of Structures(LED Light Pipe for lighthouse) in Korea. We have applied illumination by flood-lighting or facade-lighting in place of the 57 lighthouses (offshore structures) and 4 beacons. The ways of illumination of structures are using direct illumination with LED, halogen lamps and metal halide lamps, and indirect illumination with LED non-neon lamps. The illumination of structures helps a observer to identify the Aids to Navigation and w aterway. The fabricated LED Light Pipe is a transparent acrylic round bar and easy to install. The Light Pipe is arranged in two rows of L ED (78ea). It can be connected in series. It has 4 colours(Red, Green, Yellow, White). We analyzed and the horizontal divergence angle of the LED light pipe is defined as the range with 50% of maximum luminous intensity. Also, we evaluated the conspicuity on the origin al lantern and LED Light pipe for lighthouse. The field experiment was conducted in 'Yeosuguhang lighthouse' in Yeosu-city (Korea). F rom the experimental results, it was confirmed that the fabricated LED Light Pipe is clearly distinguished.

Development of Daylighting System with Modified Light Pipe for Longer Transmission Distance and Higher Illuminance

  • Vu, Hoang;Kim, Youngil;Park, Chaehwan;Park, Jongbin;Bae, Hojune;Shin, Seoyong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.93-102
    • /
    • 2021
  • In this research, we present a natural lighting system with transmission distance of 30m and lighting efficiency of 35% (30m standard) for operating hours of 7h/day (based on clear sky). The system is composed of parabolic reflective mirror and modified light pipe that can secure more than 88% of light concentration efficiency. The light loss rate of newly designed light pipe transmission system is demonstrated to 0.8 %/m in the straight-line part and 2%/m in the curved part. Modified light pipe daylighting system shows better performance over fiber optic daylighting system in terms of transmission distance (1.5 times longer) and illuminance (3.05 times higher).

Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction (이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Yoo, Seong-Yeon;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

Performance Comparison Study on LFLP and DBLP Daylighting System (LFLP와 DBLP 자연채광시스템의 성능평가 비교 연구)

  • Choi, Jeon-Yong;Kang, Eun-Chul;Lee, Euy-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.799-804
    • /
    • 2011
  • The LFLP (Linear Fresnel Light Pipe) system uses a linear Fresnel lens to follow the sun and concentrates the parallel sunlight into a line. A LFLP daylighting system has been developed and updated to a DBLP (Double Blind Light Pipe) daylighting system to improve the overall system efficiency in the morning and afternoon. The new design consists of a double-blind style with a cone-shaped light transformer. The blinds are used to collect the sun's altitude and azimuth movements through the day. Behind the two sets of blinds is the light transformer, which is based on a parabolic-shaped light concentrator. The light transformer is designed to efficiently deliver light within a thirty-degree radial spread so that the light pipe can internally reflect the light. The results of scale-model tests are encouraging, and the efficiency is three times higher than that of the previous LFLP system.

Design and Manufacture of CFRP Pipe for Bicycle Frame (자전거 프레임용 CFRP 파이프 설계제작)

  • 이범성
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.130-137
    • /
    • 2003
  • The pipe of CFRP for bicycle frame is designed and made for light weight of bicycle and then its suitability to bicycle frame is verified by comparing the other material i.e. steel, Cr-Mo steel, Al alloy pipe for bicycle frame. The pipe of CFRP is laminated to [0/$\pm$45]$_T$ and made by tape winding method and then its degree of light weight is evaluated by comparing the other pipes which is made by steel etc.