• 제목/요약/키워드: Light Output Efficiency

검색결과 232건 처리시간 0.03초

생물학적 방법에 의한 도시생활폐기물 매립지의 침출수 독성특성 평가 (Biological Evaluation for Characteristics of Leachate Toxicity from Municipal Solid Waste Landfill)

  • 황인영;류경무
    • Environmental Analysis Health and Toxicology
    • /
    • 제11권1_2호
    • /
    • pp.31-39
    • /
    • 1996
  • Leachate from municipal solid waste (MSW) landfill, effluent from leachate treatment plant, and ground water sample from a monitoring well near landfill site were tested for an acute toxicity. Microtox toxicity test was used for testing the acute toxicity of leachate and other samples. EC$_{50}$ values which a concentration of pollutant for reducing 50% light output from luminescent bacteria, Photobacterium phosphoreum were determined to assess the toxicity of pollutants as well as the relative toxicity. In addition, characteristics of leachate were studied and compared to those of phenol and pentachlorophenol (PCP) which are typical aquatic toxic pollutants. For leachate, EC$_{50}$ for 30 min incubation was 10.8%, while for phenol and PCP, 46 ppm and 1.2 ppm, respectively. the relative toxicity of treated leachate by in situ aeration with activated sludge was reduced to more than 75% of toxicity of the untreated leachate. Microtox toxicity test was failed to figure out EC$_{50}$ values for groundwater from a monitoring well since the relative toxicity of the unconcentrated sample was too low to estimate EC$_{50}$. Addition of activated carbon to leachate was reduced the relative toxicity. The reduction Pattern of the relative toxicity of leachate by mechanical aeration was similar to that of PCP, but different from that of phenol. These findings suggest that the toxicity of leachate may come from PCP-like toxic compounds rather than phenol-like one. In conclusion, the process of aeration with activated sludge might be very important to reduce the environmental toxicity of leachate. And Microtox test could be a reasonable bioassay for screening and monitoring the environmental toxicity of leachate from municipal solid waste landfill as well as for determining the reduction efficiency of the leachate toxicity by various treatment processes in leachate treatment plant.

  • PDF

저온 전도성 필름으로 본딩된 태양광 모듈의 특성 평가 및 실증 연구 (Characterization of Low-temperature Conductive Films Bonded PV Modules and Its Field Test)

  • 백수웅;최광일;이석호;전찬혁;홍승민;이길송;신현우;양연원;임철현
    • 한국전기전자재료학회논문지
    • /
    • 제27권3호
    • /
    • pp.189-194
    • /
    • 2014
  • In this paper, PV modules using a low-temperature conductive film(LT-CF) as a bonding material between a cell and a solder free ribbon were produced and chracterized, which is more environmental-friendly, cost effective and high efficient. Mainly, filed electrical performance of PV modules using three different types of bonding material; a convetional solder ribbon(SR), a LT-CF and a light-capturing Ribbon(LCR) were compared to comfirm the feasibility of LT-CF as a bonding material. The filed test were conducted for 3 months and results were discussed in terms of amount of output energy production and efficiency.

퍼지 논리 제어를 기반으로 한 2축 태양광 추적시스템에 관한 연구 (A Study on a Two-Axis Solar Tracking System Based on Fuzzy Logic Control)

  • 안병원;이희배;배철오
    • 해양환경안전학회지
    • /
    • 제21권5호
    • /
    • pp.531-537
    • /
    • 2015
  • 태양광 패널로부터 출력을 최대로 얻기 위해서는 신뢰성이 높은 태양광 추적 장치가 설계되어야 한다. 본 논문에서는 LabVIEW 프로그램을 이용하여 퍼지 제어를 기반으로 구현한 2축 태양광 추적 장치 시스템을 제작하여 그 성능에 대해서 알아보았다. 태양광 패널의 움직임을 제어하기 위한 구현된 퍼지 의사결정 시스템의 사용자 인터페이스를 통하여 모든 파라미터를 제어하고 확인할 수 있는 지능제어기와 기계적인 구동부분의 설계가 연구의 중심이 되고 있다. 실제 태양광 추적시스템을 개발하여 환경, 날씨, 계절 및 빛 상태와 같은 영향에 대해서 분석하였다. 태양광 추적장치는 실제 상황에서 시험하였고 시스템 동작과 관련된 모든 변수들은 기록되고 분석되었다. 제안한 태양광 추적시스템을 활용할 경우 고정식 패널에 비해 날씨에 따라 다르지만 최대 약 38% 정도의 더 높은 효율을 얻을 수 있어 자동으로 추적할 때 매우 좋은 결과를 얻을 수 있었다.

레이저에 의해 손상된 치아경조직 및 치수조직의 치유과정에 대한 연구 (HEALING PROCESS OF DENTAL HARD TISSUES AND PULP TISSUE AFTER LASER IRRADIATION)

  • 김철순;민병순;최호영;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.20-42
    • /
    • 1998
  • The present study was designed to understand the basic principles of the laser system and to assess the optimal coditions of the Nd:YAG laser irradiation system in order to expand the use of the laser system in the dental field. The laser system used in this study was a pulsed-wave output type and the power level is 9 watts. The incisors of developing rats were irradiated with the laser system explained above for 0.5, 1, and 2 seconds giving energy density 71, 167, and 215 J/$cm^2$ respectively. The rats were sacrificed just after irradiation or 10 minutes and 10 days after irradiation. The specimens were examined with the stereoscope, light microscope and transmission electron microscope. The results are as follows: 1. The tissue removal efficiency (depth of the cavity formed) is increased with the energy density after Nd:YAG laser irradiation. 2. The carbonized area is increased with the energy density. Cracks and melted appearance are seen in all kinds of the energy densities. 3. The lacunae in the damaged alveolar bone by the laser irradiation were empty, while those in the newly formed bone were occupied with the osteocytes. The damaged alveolar bone was repaired by the osteoblasts and macrophages on the periphery of the bone matrix. 4. The damaged enamel was replaced by the loose connective tissues showing many kinds of cells. The ameloblasts were differntiated on the replaced loose connective tissue. 5. The damaged dentin was repaired by the irregular dentin formed by the odontoblasts differentiated from the mesenchymal cells migrated from the pulp core.

  • PDF

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

3.0 kW 고출력 발진 단일 모드 Yb 광섬유 레이저 (High-power Yb Fiber Laser with 3.0-kW Output)

  • 박종선;박은지;오예진;정훈;김지원;정예지;이강인;이용수;조준용
    • 한국광학회지
    • /
    • 제32권4호
    • /
    • pp.147-152
    • /
    • 2021
  • 본 논문에서는 최고 출력 3.0 kW 발진 단일 모드 이터븀(ytterbium, Yb) 첨가 광섬유 레이저에 대해 보고한다. 고출력 광섬유 레이저의 출력을 제한하는 주된 요소인 유도 라만 산란 문턱 값과 광섬유 내 온도 분포를 계산하고 이를 바탕으로 양방향 펌핑 구조의 단일 공진기 Yb 광섬유 레이저 시스템을 제작하였다. 그 결과 4.1 kW의 펌프 출력에서 최고 출력 3.0 kW의 레이저 빔을 얻을 수 있었고, 그때의 기울기 효율은 81.5%로 계산되었다. 최고 출력에서 측정된 출력 빔의 빔질(M2)은 1.26으로 단일 공간 모드 빔 출력 특성을 가지고 있음을 확인하였고, 유도 라만 산란 및 횡모드 불안정 현상은 관측되지 않았다. 본 연구에서 얻은 광섬유 레이저 출력 결과는 지금까지 국내에서 보고된 다이오드 레이저로 펌핑한 광섬유 레이저 출력 중 가장 높은 출력이며, 향후 더 높은 출력을 얻기 위한 방법에 대해 논의하고자 한다.

집중 태양열에 의한 온도구배가 열전발전모듈의 출력 성능에 미치는 영향 (Influence of temperature gradient induced by concentrated solar thermal energy on the power generation performance of a thermoelectric module)

  • 최경후;안다훈;부준홍
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.777-784
    • /
    • 2017
  • 일반적으로 열전발전 소자를 사용하여 에너지 하베스팅을 하는 경우, 시스템의 작동환경에 의해 주어지는 온도구배를 활용하게 된다. 따라서 열전소자의 특성상 큰 온도구배를 기대하기 어려운 작동환경에서는 원하는 출력을 얻을 수 없으며, 작동 온도가 높을 때 얻어지게 되는 최적의 발전효율을 기대하기 힘들다. 자연환경에서 얻을 수 있는 태양에너지를 활용한 신재생 에너지의 활용은 그 동안 태양광발전이나 태양열발전에 국한되어 왔다. 태양광발전은 태양광의 일정 파장대만 사용하고 빛의 산란에 의해 발전효율이 낮아지는 단점이 있으며, 태양열발전은 일반적으로 대규모 설비를 갖춰야 하는 공간상의 제약이 있다. 본 연구에서는 태양열을 집광하여 열전소자에 조사함으로서 큰 온도구배를 형성하여 상용 열전소자의 출력을 향상시킬 수 있는 간단한 소형 발전시스템을 설계 및 제작하였다. 장시간 태양열 집중을 위해 태양 추적 장치를 설치하였으며, 열전소자 하부에 고온의 태양열이 전달되어 온도 편차가 줄어드는 현상을 막기 위해 액체 순환식 냉각기를 설치하여 큰 온도구배를 유지할 수 있도록 설계한 후, 일련의 실험으로 시험하여 그 유용성과 타당성을 검증하였다.

침철석과 자외선 LED를 이용한 아비산염의 광촉매 산화 (Photocatalytic Oxidation of Arsenite Using Goethite and UV LED)

  • 전지훈;김성희;이상우;김순오
    • 대한환경공학회지
    • /
    • 제39권1호
    • /
    • pp.9-18
    • /
    • 2017
  • 비소는 다양한 유해물질들 중 독성이 가장 크다고 알려져 있으며, 자연발생 또는 인간의 활동으로부터 비소오염이야기될 수 있다. 지하수 내 비소는 환원 환경에서 아비산염, 산화 환경에서 비산염 형태로 존재한다. 아비산염은 비산염보다 독성이 강하고 이동성이 더 크기 때문에 아비산염을 비산염으로 산화시켜 독성을 저감시키기 위한 연구가 많은 관심을 받고 있다. 본 연구에서는 비소로 오염된 지하수로부터 독성이 높은 아비산염을 독성이 낮은 비산염으로 산화시키기 위하여 자외선램프 및 자외선 LED 광원과 침철석 촉매를 이용한 광촉매 산화 공정에 대하여 연구하였다. 광산화 실험에서 광촉매로 사용된 침철석의 투여량이 0.05 g/L일 때 가장 높은 광산화 효율을 나타났다. 또한 광원의 파장별 겉보기 광산화 효율을 비교한 결과, 자외선램프가 자외선 LED에 비하여 아비산염의 산화 효율이 더 높은 것으로 나타났다. 하지만, 자외선 방사량을 기준으로 보정하면, 자외선 LED가 자외선램프보다 광산화 효율이 더 높은 것으로 평가되었다. 본 연구를 통해 침철석 광물이 존재하는 지하수 환경에서 외부로부터 다른 광촉매를 투여하지 않고 친환경적인 광산화 공정을 이용하여 비소의 독성 저감이 가능하다는 것을 알 수 있었다. 또한, 공정 또한 자외선 LED가 자외선램프의 단점을 보완할 수 있는 대체 광원으로 광산화 공정에 활용 가능하다는 것을 확인하였다.

Sodium Alginate와 Cellulose가 흰쥐의 소화생리에 미치는 영향 (Effects of Sodium Alginate and Cellulose on Gastrointestinal Physiology in Rats)

  • 송영선;양정례;서명자
    • 한국식품영양과학회지
    • /
    • 제25권4호
    • /
    • pp.551-559
    • /
    • 1996
  • 10% sodium alginate와 cellulose의 장기간 섭취가 휜쥐(Sprague-Dawley, 수켯)의 소화생리에 미치는 영향은 다음과 같았다. 체중 증가량은 무섬유식이군과 cellulose군에 비해 sodium alginate군에서 유의적으로 낮았다(p<0.05). 소장의 무게와 길이 및 단위길이 당 무게는 무섬유식이군과 cellulose군에 비해 sodium alginate군에서 유의적으로 높았다(p<0.05). 분변의 부피 및 무게는 무섬유식이군에 비해 식이섬유 첨가군에서 높게 나타났으며(p<0.05), 건조 중량은 cellulose군에서 가장 높았다. 분변으로 배설된 단백질 및 직질의 함량은 무섬유식이군에 비해 식이섬유 첨가군에서 유의적으로 높았으며 (p<0.05), 따라서 단백질과 지질의 소화율은 무섬유식이군에 비해 cellulose군과 sodium alginate군에서 유의적으로 낮았다(p<0.05). 췌장의 amylase와 lipase 활성은 세군간에 유의적인 차이가 없었으나 무섬유식이군에 비해 식이섬유군에서 다소 낮은 경향을 보였으며, 췌장의 Prntease 활성은 무섬유식이군과 cellulose군에 비해 sodium alginate군에서 유의적으로 낮았다(p<0.05). 췌장의 DNA 및 RNA 함량은 식이군간에 유의적인 차이가 없었으나 췌장 단백질 함량은 무섬유식이군에 비해 식이섬유군에서 높게 나타났다(p<0.05). SEM과 LM을 이용한 연구에서 식이섬유의 섭취는 주름을 가진 넓은 잎사귀모양의 융모세포와 goblet cell의 증식을 유도하는 것을 확인하였다. 이상의 결과를 종합해 볼 때, 식이섬유의 섭취는 지방과 단백질의 흡수를 억제하여 영양소의 소화율을 떨어뜨리며 소화기관의 형태적.생화학적 변화를 유도함을 알 수 있었다.

  • PDF

고온초전도 동기모터의 계자손실 해석 및 냉각 해석 (Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor)

  • 김기찬;이대동
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.69-74
    • /
    • 2018
  • 산업현장에서 사용되는 대형 모터는 전기자권선의 절연내력 저하 및 과열문제 등으로 인하여 정지사고의 위험이 높고 산업재해의 규모가 크므로 넓은 장소의 확보가 필요하다. 따라서 기존 모터에 비해 소형, 경량이면서 절연내력이 뛰어난 대용량 모터가 요구되어지고 있으며 이에 대한 연구가 활발히 진행되어지고 있다. 초전도 모터는 기존의 발전기나 모터와 같은 회전기의 계자코일을 초전도 화하여 계자의 발생을 크게 증가시킴으로서, 기기의 효율과 출력을 높이고, 소형화 및 경량화, 안정도 향상 등의 장점을 가지고 있으므로 초전도 선재의 성능을 발휘할 수 있도록 선제의 임계온도 이하로 낮추어줄 수 있는 냉각시스템의 설계 및 해석기술이 매우 중요하다. 따라서 본 연구에서는 100HP 고온초전도 동기모터의 개념설계를 통한 계자손실 해석과 냉각시스템의 저온 열전달 해석을 수행하였다. 계자손실 해석 결과, 고온초전도 선재를 사용하게 되면 균일한 공극자속밀도가 나타남을 확인하였다. 그리고 가스네온 및 액체네온에 대한 저온 열전달 해석 결과, 고온초전도 선재의 저온 안정성을 유지하기 위해서는 액체네온 1kg/min의 유량의 사용이 적합함을 확인하였다.