• Title/Summary/Keyword: Light Flux Ratio

Search Result 39, Processing Time 0.025 seconds

Illuminance Distribution and Photosynthetic Photon Flux Density Characteristics of LED Lighting with Periodic Lattice Arrangements

  • Jeon, Hee-Jae;Ju, Kang-Sig;Joo, Jai-Hwang;Kim, Hyun-Gyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.1
    • /
    • pp.16-18
    • /
    • 2012
  • LED lighting systems that combine lighting capability, emotional and physiological characteristics are required for lighting source and multifunctional applications. In this work, Simulation studies using optical analysis software packages, Light Tools, are presented. This is done to estimate the uniformity ratio of illuminance and photosynthetic photon flux density (PPFD) of the periodic 2D lattice arrangements, such as square, diamond, two-way bias quadrangular, hexagonal, and Kagome lattices, under the same transmissivity, absorptance and reflectivity. It has been found out that the two-dimensional Kagome lattice arrangement exhibited high uniformity ratio of illuminance and PPFD compared to other lattices. Accordingly, these results can be used to guide a design and improve the lighting environment which in turn would maximize the uniform distributions of illuminance.

Development of An Optical Surface Roughness Sensor for On-the-Machine Measurement (기상 측정을 위한 광학적 표면 거칠기 측정 센서 개발)

  • Kim, Hyun-Soo;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.168-178
    • /
    • 1994
  • This paper presents an optical surface roughness sensor developed for intermediate- process measurement on the machine. The light scattering method is adopted for the sensor, which is designed conpact and flexible enough to apply to 'on the machine' measurement of surface roughness. The developed sensor has special features such that it makes use, as the measurement parameter, of the ratio between fluxes of the incident light, and the specularly and partly diffusely reflected light, and that it can adjust the incident light angle. The experimental investigation reveals not only the sensor has good performance as a surface roughness sensor but the sensor is very robust so as to be useful in in-process measurement.

  • PDF

Monitoring observation of PG0934+013 using The Southern African Large Telescope

  • Park, Dawoo;Woo, Jong-Hak;Romero-Colmenero, Encarni;Crawford, Steven M.;Barth, Aaron J.;Pei, Liuyi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.54-54
    • /
    • 2013
  • We performed spectroscopic and photometric monitoring observations of a QSO, PG0934+013 for a reverberation-mapping analysis, using the 9-m Southern African Large Telescope (SALT) for spectroscopy and the 2-m Faulkes Telescope North and the South for photometry. The monitoring campaign was carried out for 5 month between December 2012 to April 2013, providing 20 spectroscopic epochs and ~40 photometric epochs. Based on the obtained spectra, which typically have a signal-to-noise ratio to 30-60, we performed multicomponent decomposition using various components, i.e., power-law continuum, FeII emission complex, and broad and narrow emission lines, to properly measure the Hbeta line flux. After a flux normalization using [O III] 5007 line luminosity, we obtained a rms spectrum from all epochs, which shows clear variability of Hbeta line. We find that Hbeta line flux decreases by ~20% during the monitoring period while the continuum flux obtained from the aperture photometry based on the imaging data, shows similar variability. The current Hbeta light curve shows monotonic decrease and a reliable cross correlation analysis between Hbeta and continuum light is difficult. Nevertheless, we obtained a preliminary lag measurements as ~24 light days.

  • PDF

Analysis of Spectral Light Intensity of High Pressure Sodium and Metal Halide Lamps for Plant Growth (식물생장용 고압나트륨램프와 메탈할라이드램프의 분광 광강도 분석)

  • Lee, Hye-In;Kim, Yong-Hyeon;Kim, Dong-Eok
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.413-419
    • /
    • 2010
  • Plant growth was greatly affected by the spectral distribution and light intensity of artificial lighting sources. In this study, the spectral characteristics of high power sodium (HPS) lamps and metal halide (MH) lamps produced by three different manufacturers were measured. Even though the spectral distribution of HPS lamps with lamp wattage of 250 W and 400 W was very similar, but the spectral light intensity by the manufacturers was different. Difference in the spectral light intensity of MH lamps by the manufacturers was increased with the increasing lamps wattage. Light intensity at the region of blue (B), green (G), red (R) and far-red (FR) light of HPS and MH lamps was also analyzed. HPS lamps showed the light intensity in order of R, FR, B and G light. The ratio of G, B, R and FR to photosynthetic photon flux (PPF) of HPS lamps with the lamp wattage of 250 W was 3.0-3.2%, 5.5-5.9%, 17.3-19.2% and 6.5-7.8%, respectively. For MH lamps, it showed the light intensity in order of R, FR, B, and G. The ratio of B, G, R, and FR to PPF of MH lamps with 250 W was 14.0-15.5%, 22.6-27.5%, 7.5-9.5% and 2.7-4.2%, respectively. HPS and MH lamps with 400 W had a relatively smaller ratio of R and FR to PPF than those with 250 W. HPS lamps showed that the ratio of light intensity of B and FR to R was 0.15-0.28 and 0.36-0.4, respectively. For MH lamps, the ratio of light intensity of B and FR to R was 1.26-2.72 and 0.27-0.56, respectively. From these results, it was concluded that the portion of blue light of MH lamps was higher than those of HPS lamps.

On-machine Measurement for grinding Machines (연삭기에서의 기상 측정)

  • Kim, Hyun-Soo;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.27-36
    • /
    • 2001
  • 본고에서는 고정도 제품을 생산하는 연삭기에 대해 가공물 및 연삭 공구인 연삭 숫돌을 기상에서 측정하기 위한 여러 가지 방법들을 소개하였고 일부는 적응 예를 기술하였다. 소개된 기상 측정장치들은 특히 반복 공정이 필요한 연삭 현장에서 생산성 향상을 위해 유용하게 활용될 수 있을 것으로 생각된다. 그러나 관련 연구가 지속된다면 연삭기의 작업조건 자동 설정, 연삭 상태 진단 등, 연삭기의 지능화에도 적극적으로 응용될 수 있을 것으로 기대된다.

  • PDF

A Method for Measurement of Roughness of Ground Surfaces by Using Fluxes of Scattered Lights (산란광속측정에 의한 연삭가공 표면 거칠기 측정방법)

  • Hong, Seong-Wook;Kim, Hyun-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.4
    • /
    • pp.46-54
    • /
    • 1995
  • This paper presents a simple method for measurenemt of roughness of ground surfaces. The present method utilizes fluxes of scattered lights condensed through lenses aligned along the specular direction. A theoretical analysis is preformed for the purpose of investigating the possibility of the method as well as determining the experimental condition. Experiments are also performed to show the effectiveness and robustness of the proposed method. The theoretical and experimental results show that the proposed method is simple enouth to implement and has a potential to identify a wide range of roughness of ground surfaces.

  • PDF

Growth and Flowering Responses of Petunia to Various Artificial Light Sources with Different Light Qualities

  • Park, In Sook;Cho, Kyung Jin;Kim, Jiseon;Cho, Ji Yoon;Lim, Tae Jo;Oh, Wook
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.55-66
    • /
    • 2016
  • This study was carried out to investigate the effect of artificial light sources with different light qualities on the growth and flowering characteristics of a herbaceous long-day plant, Petunia ${\times}$ hybrida Hort. Seedlings of petunia cultivar 'Madness Rose' were potted, acclimated for one week, and grown in a phytotron equipped with tube- and bulb-type fluorescent lamps (FL tube and bulb), tube-type white light-emitting diodes (LED tube), halogen lamps (HL), metal halide lamps (MH), and high pressure sodium lamps (HPS) for 10 weeks. The temperature, photoperiod, and photosynthetic photon flux density (PPFD) in the phytotron were $22{\pm}2^{\circ}C$, 16 h, and $25{\pm}2{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. Light sources combined with HL promoted stem elongation, and plant height and internode length decreased with increasing red to far-red (R:FR) ratio. FL tube + LED tube, HPS, and FL tube promoted branching, whereas plants grown under light sources combined with HL did not have any branches. Days to flowering (from longest to shortest) occurred as follows: FL tube + HL > FL tube + HL > MH > HPS = FL tube + FL bulb > FL tube + LED tube > LED tube > FL tube, indicating that reducing the R:FR ratio of the light sources promoted flowering. Only 20% of plants grown under an FL tube flowered, whereas under all other treatments, 100% of plants flowered. At 10 weeks after treatment, plants grown under HPS and MH had (cumulatively) 12 open flowers, and those grown under FL tube + FL bulb, LED tube, FL tube + LED tube, and HPS treatment had approximately seven flower buds. These results suggest that light sources with low R:FR ratios promote flowering and stem elongation in petunia, but they reduce its ornamental value due to overgrowth and poor branching.

Early Hardening Behavior of Natural Hydraulic Lime Paste by Multiple Light Scattering Analysis (Multiple Light Scattering 분석법을 이용한 천연수경성석회의 초기경화 거동)

  • Moon, Ki-Yeon;Cho, Kye-Hong;Cho, Jin-Sang;Hong, Chang-Woo
    • Resources Recycling
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2017
  • In the present study, the multiple light scattering method was used for analysis of early hardening behavior of natural hydraulic lime (NHL) containing inorganic additives. In order to improve the properties of self-manufactured NHL, blast furnace slag and three types of gypsum were mixed with mixing ratio, and a water/solid ratio of fresh NHL paste was fixed 0.6. The fresh pastes in flat-bottomed cylindrical glass tubes were placed in the instrument. The backscattering flux (BS) of light from fresh pastes was then periodically measured at 10 minutes intervals the entire length of the sample (55mm) at $23^{\circ}C$ for 24 hours. The rate of increase of BS, slope of a linear equation to the mean value of BS (%) as a function of hydration time, was increased from 0.02 to 0.38 BS %/hour due to addition of blast furnace slag and gypsum. In the case of addition of hemi-hydrate, BS (%) and rate of increase in BS were highest.

Development of Quantification Method for Bioluminescence Imaging (발광영상에 대한 정량화 방법 개발)

  • Kim, Hyeon-Sik;Choi, Eun-Seo;Tak, Yoon-O;Choi, Heung-Kook;Lee, Ju-Young;Min, Jung-Joon;Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.451-458
    • /
    • 2009
  • Purpose: Optical molecular luminescence imaging is widely used for detection and imaging of bio-photons emitted by luminescent luciferase activation. The measured photons in this method provide the degree of molecular alteration or cell numbers with the advantage of high signal-to-noise ratio. To extract useful information from the measured results, the analysis based on a proper quantification method is necessary. In this research, we propose a quantification method presenting linear response of measured light signal to measurement time. Materials and Methods: We detected the luminescence signal by using lab-made optical imaging equipment of animal light imaging system (ALIS) and different two kinds of light sources. One is three bacterial light-emitting sources containing different number of bacteria. The other is three different non-bacterial light sources emitting very weak light. By using the concept of the candela and the flux, we could derive simplified linear quantification formula. After experimentally measuring light intensity, the data was processed with the proposed quantification function. Results: We could obtain linear response of photon counts to measurement time by applying the pre-determined quantification function. The ratio of the re-calculated photon counts and measurement time present a constant value although different light source was applied. Conclusion: The quantification function for linear response could be applicable to the standard quantification process. The proposed method could be used for the exact quantitative analysis in various light imaging equipments with presenting linear response behavior of constant light emitting sources to measurement time.

A MONTE CARLO STUDY OF FLUX RATIOS OF RAMAN SCATTERED O VI FEATURES AT 6825 Å AND 7082 Å IN SYMBIOTIC STARS

  • Lee, Young-Min;Chang, Seok-Jun;Heo, Jeong-Eun;Hong, Chae-Lin;Lee, Hee-won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.57.3-58
    • /
    • 2016
  • A symbiotic star is a wide binary system consisting of a hot white dwarf and a mass losing giant, where the giant loses its material in the form of a slow stellar wind resulting in accretion onto the white dwarf through gravitational capture. Symbiotic stars are known to exhibit unique spectral features at 6825 and 7082, which are formed from O VI 1032 and 1038 through Raman scattering with atomic hydrogen. In this Monte Carlo study we investigate the flux ratio of 6825 and 7082 in a neutral region with a geometric shape of a slab, cylinder and sphere. By varying the amount of neutral hydrogen parametrized by the column density along a specified direction, we compute and compare the flux ratio of Raman scattered O VI 6825 and 7082. In the column density around 1020 cm-2, flux ratio changes in a complicated way, rapidly decreasing from the optically thin limit to unity the optically thick limit as the column density increases. It is also notable that when the neutral region is of a slab shape with the O VI source outside the slab, the optically thick limit is less than unity, implying a significant fraction of O VI photons escape through Rayleigh scattering near the boundary. We compare our high resolution CFHT data of HM Sge and AG Dra with the data simulated with finite cylinder models confirming that 'S' type symbiotic tend to be characterized by thicker HI region that 'D' type counterparts. It is expected that this study will be useful in interpretation of the clear disparity of Raman O VI 6825 and 7082 profiles, which will shed much light on the kinematics and the asymmetric distribution of O VI material around the hot white dwarf.

  • PDF