• Title/Summary/Keyword: Life Safety Code

Search Result 122, Processing Time 0.024 seconds

Optimal Life Cycle Cost Design of a Bridge (교량의 생애주기비용 최적설계)

  • Park, Jang-Ho;Shin, Yung-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.115-122
    • /
    • 2010
  • The importance of the life cycle cost (LCC) analysis for bridges has been recognized over the last decade. However, it is difficult to predict LCC precisely since the costs occurring throughout the service life of the bridge depend on various parameters such as design, construction, maintenance, and environmental conditions. This paper presents a methodology for the optimal life cycle cost design of a bridge. Total LCC for the service life is calculated as the sum of initial cost, damage cost, maintenance cost, repair and rehabilitation cost, user cost, and disposal cost. The optimization method is applied to design of a bridge structure with minimal cost, in which the objective function is set to LCC and constraints are formulated on the basis of Korean Bridge Design Code. Initial cost is calculated based on standard costs of the Korea Construction Price Index and damage cost on damage probabilities to consider the uncertainty of load and resistance. Repair and rehabilitation cost is determined using load carrying capacity curves and user cost includes traffic operation costs and time delay costs. The optimal life cycle cost design of a bridge is performed and the effects of parameters are investigated.

An Outline of Food Ethics (음식윤리 개요)

  • Kim, Suk-Shin
    • Food Science and Industry
    • /
    • v.49 no.2
    • /
    • pp.83-97
    • /
    • 2016
  • This review was performed to outline the food ethics to the professionals in the field of food science and industries. Food ethics is the ethics or ethical consideration concerning food; while, the keywords of food ethics are a life, happiness and the wisdom. The ultimate goal as well as the first principle of food ethics is a sustainable living of human race. In order to reach the goal a coexistence of humans and nature, coexistence of humans and humans, and the fulfillment of essential requirements of a food are needed. The needs yield six categorical imperatives such as a respect for life, preservation of nature, distributive justice without deception or fakes, prior consideration of consumer, moderation and balance neither overs nor shorts, and the assurance of safety. The core principles corresponding to the categorical imperatives include a respect for life, environmental preservation, justice, priority of consumer, dynamic equilibrium, and the priority of safety. The core principles approach is a simple, clear, and practical method in solving ethical issues. The code of food ethics is also based on the core principles.

Combining in-plane and out-of-plane behaviour of masonry infills in the seismic analysis of RC buildings

  • Manfredi, V.;Masi, A.
    • Earthquakes and Structures
    • /
    • v.6 no.5
    • /
    • pp.515-537
    • /
    • 2014
  • Current seismic codes (e.g. the NTC08 Italian code and the EC8 European code) adopt a performance-based approach for both the design of new buildings and the assessment of existing ones. Different limit states are considered by verifying structural members as well as non structural elements and facilities which have generally been neglected in practice. The key role of non structural elements on building performance has been shown by recent earthquakes (e.g. L'Aquila 2009) where, due to the extensive damage suffered by infills, partitions and ceilings, a lot of private and public buildings became unusable with consequent significant socio-economic effects. Furthermore, the collapse of infill panels, particularly in the case of out-of-plane failure, represented a serious source of risk to life safety. This paper puts forward an infill model capable of accounting for the effects arising from prior in-plane damage on the out-of-plane capacity of infill panels. It permits an assessment of the seismic performance of existing RC buildings with reference to both structural and non structural elements, as well as of their mutual interaction. The model is applied to a building type with RC framed structure designed only to vertical loads and representative of typical Italian buildings. The influence of infill on building performance and the role of the out-of-plane response on structural response are also discussed.

A Study on the Development of Database for Lighting Design System (조명 설계 시스템을 위한 데이터베이스 개발에 관한 연구)

  • 조성오
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.4
    • /
    • pp.196-203
    • /
    • 2004
  • In The Lighting design is important to acknowledge appearance space. Development of artificial light makes a extension to life space in the Modern life. With the rapid development of efficient light sources, have lighting design acquired the tools that allow artificial lighting to be produced with adequate illuminance levels. However, by the task of defining the objectives and methods behind discipline, of deciding on the criteria by which the artificial lighting that is now provide many available data to be anpaied. The main concern is which illuminace levels and types of lighting will ensure optimum visual performance, high productive and safety at design which are affordable. This study is support to standard design process with material reflection rate, installing the lighting fixture, task illuminance level and automatic arithmetic calculation during the lighting design. Lighting Design database can check and support other final lighting level. A quantitative light that is primarily oriented toward providing a recommended illuminance level, the criterion of develop a concept that goes beyond the requirements that would ensure productivity and safety to meet the needs of the architecture and interior space. illuminance level is compose to space task and space code according to KS A 3011. To be able to design the visual effect of an environment the central reference quantity has to provided the Database.

Simulation Study of Smoke Control Accordance with Zoning in the Atrium Space of High-rise Buildings (초고층 건물 아트리움 공간에서의 제연구획에 따른 시뮬레이션 연구)

  • Ryu, Hyungkyou;Bae, Sanghwan;Lee, Byungseok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.7
    • /
    • pp.335-342
    • /
    • 2014
  • The big issue in fire and life safety protection in atriums is that hot smoke can spread vertically via the atrium openings, and impact atrium floors remote from the fire. Three different strategies to provide fire and life safety protection for atrium space were evaluated in this study, using the FDS model. Strategy A is the atrium protection approach addressed in the Korean Building Fire Protection Code, where atria are required to be enclosed with fire shutters from the $2^{nd}$ floor to the atrium top, and the ground floor is allowed to open to the atrium; in this case, no smoke control is required. Strategy B is the atrium protection approach, with smoke control provided in accordance with NFPA 92B; in this case, no atrium floor is enclosed. Strategy C is the atrium protection approach, in which some of the upper atrium floors are enclosed (the case of the top atrium floor being enclosed is evaluated in this study), and atrium smoke control is also provided to protect the lower atrium floors.

A Study on Creep Crack Growth Properties of 308 SS for FFS Evaluation of High Temperature Components (고온설비의 FFS평가를 위한 308 스테인리스강의 크리프 균열성장 재료물성에 대한 연구)

  • Lee, Kyung-Yong;Baek, Un-Bong;Yoon, Kee-Bong
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.5-10
    • /
    • 2002
  • For fitness-for-service evaluation of high temperature plant components with defects, crack growth life must be assessed properly as indicated in the recent draft of API 579 code. Type 308 stainless steel has been widely used as a field weld material in the petrochemical industry. In this study, creep crack data of type 308 stainless steel are collected and re-analyzed using $C_t$ as a characterizing fracture parameter. A unique da/dt versus $C_t$ relationship was obtained despite of difference of creep deformation constant of the reviewed materials and specimen geometry of the tested specimens. The obtained results can be employed for crack growth life assessment and fitness-for-service evaluation for the cracks in high temperature components. It is also argued that since the effect of creep properties and other material variability on the creep crack growth behavior would be minor the obtained model may be applied for most of the 308 stainless steels.

Service Life Variation for RC Structure under Carbonation Considering Korean Design Standard and Design Cover Depth (국내설계기준과 피복두께를 고려한 RC 구조물의 탄산화 내구수명의 변동성)

  • Kim, Yun-Shik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.15-23
    • /
    • 2021
  • In this paper, service life for RC(Reinforced Concrete) substructure subjective to carbonation was evaluated through deterministic and probabilistic method considering field investigation data and Design Code(KDS 14 20 40). Furthermore changes in service life with increasing COV(Coefficient of Variation) and equivalent safety index meeting the same service life were studied. From the investigation, the mean and its COV of cover depth were evaluated to 70.0 ~ 90.0 mm and 0.2, respectively. With intended failure probability of 10.0 % and 70 mm of cover depth, service life decreased to 137 years, 123 years, and 91 years with increasing COV of 0.05, 0.1, and 0.2, respectively. In the case of 80 mm of cover depth, it changes to 179 years, 161 years, and 120 years with increasing COV. The equivalent safety index meeting the same service life from deterministic method showed 1.66 ~ 3.43 for 70 mm of cover depth and 1.61 ~ 3.24 for 80 mm of cover depth, respectively. The various design parameters covering local environment and quality condition in deterministic method yields a considerable difference of service life, so that determination of design parameters are required for exposure conditions and parameter variation.

Analysis of Detection Ability Impact of Clang Static Analysis Tool by Source Code Obfuscation Technique (소스 코드 난독화 기법에 의한 Clang 정적 분석 도구의 성능 영향 분석)

  • Jin, Hongjoo;Park, Moon Chan;Lee, Dong Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.3
    • /
    • pp.605-615
    • /
    • 2018
  • Due to the rapid growth of the Internet of Things market, the use of the C/C++ language, which is the most widely used language in embedded systems, is also increasing. To improve the quality of code in the C/C++ language and reduce development costs, it is better to use static analysis, a software verification technique that can be performed in the first half of the software development life cycle. Many programs use static analysis to verify software safety and many static analysis tools are being used and studied. In this paper, we use Clang static analysis tool to check security weakness detection performance of verified test code. In addition, we compared the static analysis results of the test codes applied with the source obfuscation techniques, layout obfuscation, data obfuscation, and control flow obfuscation techniques, and the static analysis results of the original test codes, Analyze the detection ability impact of the Clang static analysis tool.

Estimation of Dynamic Motions and Mooring Forces for Floating Type Offshore Platform Based on Hydrodynamic Analysis (동수력학 해석 기반 부유식 해양 플랫폼의 동적 운동 및 계류력 산정)

  • Cha, Ju-Hwan;Moon, Chang-Il;Song, Chang-Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.48-57
    • /
    • 2012
  • This paper deals with numerical analyses in the context of estimations of hydrodynamic motions and dynamic loads for a floating type offshore platform using some exclusive simulation code such as code for the simulation of a floating type of offshore crane based on multi-body dynamics, along with the commercial code AQWA. Verifications of numerical models are carried out by comparing the RAO results from the simulation code. In the verification analyses, hydrodynamic motions are examined in the frequency domain for the floating type offshore platform according to the mooring lines. Both the hydrodynamic motions and dynamic loads are estimated for floating type offshore platforms equipped with the catenary type and taut mooring lines. A review and comparison are carried out for the numerically estimated results. The structural safety of the connection parts in an offshore structure such as a floating type offshore platform is one of the most important design criteria in view of fatigue life. The dynamic loads in the connecting area between a floating type offshore platform and its mooring lines are estimated in detail according to variations in the mechanical properties of the mooring lines. The dynamic tension load on the mooring lines is also estimated.

A Study on the Safety and Usability of University Dormitory Buildings (대학 기숙사 건물의 안전성 및 사용성 평가 연구)

  • Chae, Kyoung-Hun;Heo, Seok-Jae;Hur, Moo-Won
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.26 no.2
    • /
    • pp.3-10
    • /
    • 2019
  • This study evaluated the vibration use and safety of students living in the dormitories on the 12th and 14th floors by feeling uncomfortable. The measurement method was to measure the acceleration due to free vibration and single - person walking. The slab stiffness was then calculated, and the usability and safety were compared according to international standards. The natural frequency of the slab was 6.8 Hz. The natural frequency of a typical slab is around 15Hz. Therefore, the evaluation slab is judged as a flexible floor structure. It is considered that there is a high possibility of resonance in the middle of daily life because of low natural frequency and near harmonic component of walking vibration. As a result, the RMS acceleration level is within the tolerance range defined by ISO 10137 code, but the 13th floor exceeds the reference limit, so that a sensitive person could detect the vibration somewhat in the lying position.