• 제목/요약/키워드: LiBr

검색결과 231건 처리시간 0.024초

삼중효용 흡수사이클의 성능특성 평가 (evaluation of Performance Characteristic on Triple Effect Absorption Cycle)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

작동매체에 따른 2중효용 흡수식 시스템의 성능해석 (Thermodynamic Analysis of Double-effect Absorption Heat Pump System with New Working Pairs)

  • 원승호;이영수
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.250-255
    • /
    • 1991
  • Performance analysis of double-effect absorption heat pump system has been done to find improved working pairs (or mixture) by computer simulation. Based on the thermodynamic analysis, the coefficient of performance and mass flow ratio are investigated to compare three aqueous solutions [LiCl-water, LiSCN-LiBr-water, LiCl-$CaCl_2$-$Zn(NO_3)_2$-water] which was developed for only cooling, with conventional LiBr-water solution. It is found that the performances of the new aqueous solutions are better than that of LiBr-water solution not only in cooling systems, but also in heating systems. Theoretical thermodynamic performance data can be used in heat recovery systems by basic design data.

  • PDF

LiBr 수용액으로 용해시켜 제조한 거대억새 홀로셀룰로오스 용해 및 재생 필름특성 (Dissolution Characteristics and Regenerated Miscanthus Sinensis Holocellulose Film Prepared by Dissolving the LiBr Solution)

  • 양지욱;권구중;황교정;황원중;황재현;김대영
    • 펄프종이기술
    • /
    • 제47권6호
    • /
    • pp.89-97
    • /
    • 2015
  • In this study, dissolution characteristics of 60% LiBr aqueous solution for Miscanthus sinensis holocellulose in accordance with heating time and characteristics of regenerated films were analyzed. Miscanthus sinensis holocellulose was made by peracetic acid method. During the dissolution of 60% LiBr solution for the holocellulose, the dissolution was started from the tip of the cellulose fiber after about 7 minutes, and proceeded as it swollen like a balloon. A lot of Si was identified by analyzing hollocellulose regenerated film through SEM/EDS. Cross section of regenerated film as dissolution time till 40 minutes of dissolution showed multilayered structure and fiber orientation. But after 40 minutes, multilayered structure and fiber orientation was not observed. The crystal structure of the holecellulose was transformed cellulose I into cellulose II. Therefore, dissolution for 20 minutes with 60% LiBr solution in the condition of $190^{\circ}C$ hot plate was shown as an optimum condition to manufacture the holocellulose regenerated film.

헬리컬 흡수기의 열ㆍ물질전달 특성에 관한 실험적 연구 (An Experimental Study on Beat and Mass Transfer Characteristics of Helical Absorber)

  • 권오경;윤재호;윤정인
    • 대한기계학회논문집B
    • /
    • 제28권1호
    • /
    • pp.81-88
    • /
    • 2004
  • In this study, heat and mass transfer characteristics of five components solution (LiBr+Lil+LiNO$_3$+LiCl+$H_2O$) which could be substituted for commonly used LiBr solution are tested using a helical absorber. The arrangement of helical-typed heat exchangers allows to make the system more compact as compared to conventional one. The effects of experimental parameters, such as the solution flow rate, cooling water, solution temperature, solution concentration and surfactant have been investigated in view of the heat and mass transfer. The results of the experiment of heat and mass transfer performance show that five components solution should have 2% higher concentration fur equal absorption capacity of LiBr solution. But considering that five components solution have higher solubility than LiBr solution about 4% high concentration, five components solution could be applied to a small sized water cooled or air cooled absorption chiller/heater. The increase of heat and mass transfer coefficient by surfactant addition is about 25∼30% and 23∼40% respectively.

Ditopic Binding of Alkali Halide Ions to Trimethylboroxine

  • Jeong, Kyung-Hwan;Shin, Seung-Koo
    • Mass Spectrometry Letters
    • /
    • 제1권1호
    • /
    • pp.9-12
    • /
    • 2010
  • Trimethylboroxine (TMB) is a six-membered ring compound containing Lewis acidic boron and Lewis basic oxygen atoms that can bind halide anion and alkali metal cation, respectively. We employed Fourier transform ion cyclotron resonance spectroscopy to study the gas-phase binding of $LiBrLi^+$ and $F^-(KF)_2$ to TMB. TMB forms association complexes with both $LiBrLi^+$ and $F^-(KF)_2$ at room temperature, providing direct evidence for the ditopic binding. Interestingly, the $TMB{\cdot}F^-(KF)_2$ anion complex is formed 33 times faster than the $TMB{\cdot}Li^+BrLi$ cation complex. To gain insight into the ditopic binding of an ion pair, we examined the structures and energetics of $TMB{\cdot}Li^+$, $TMB{\cdot}F^-$, $TMB{\cdot}LiF$ (the contact ion pair), and $Li^+{\cdot}TMB{\cdot}F^-$ (the separated ion pair) using Hartree-Fock and density functional theory. Theory suggests that $F^-$ binds more strongly to TMB than $Li^+$ and the contact ion-pair binding ($TMB{\cdot}LiF$) is more stable than the separated ion-pair binding ($Li^+{\cdot}TMB{\cdot}F^-$).

Mn2O3가 LiNiBi Ferrite의 물리적 특성에 미치는 영향 (Physical Properties of Polycrystalline Mn2O3-Substituted LiNiBi Ferrite)

  • 고재귀
    • 한국재료학회지
    • /
    • 제14권9호
    • /
    • pp.655-658
    • /
    • 2004
  • Lithium ferrites are a low-cost material which have been prominent in the high frequency core industry because of their excellent temperature performance and high squareness ratio. In order to develope the lithium ferrites with the high squareness and low coercive force, the ferrites of $Li_{0.48}Bi_{0.02}Ni_{0.04}Fe_{2.46-x}O_4$ were investigated the by varying composition, temperature and frequency. Electric loss of the Li-ferrite was lowered with the substitution of $Mn_{2}O_3$. The addition of $Mn_{2}O_3$ increased the magnetic induction (Bm&Br) but decreased the coercive force (Hc) and the squareness ratio (R=Br/Bm). Also, the Br value was stable at environmental temperature variation.

삼중효용 LiBr/물 흡수식 냉방기의 사이클 시뮬레이션 (Cycle simulation of a triple effect LiBr/water absorption chiller)

  • 조광운;정시영;정은수
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.79-87
    • /
    • 1998
  • Basic design of a 50USRT(175㎾) triple effect absorption chiller driven by hot gas has been carried out for both parallel and series flow cycles. Parallel flow cycle showed higher COP, however, the temperature in the generator was also higher than that in series flow cycle. Dynamic operation behavior of a parallel flow system at off-design conditions, such as the change in heat transfer medium temperature or the construction change of the system components, has been investigated in detail. It was found that the cooling capacity was seriously decreased by reducing hot gas flow rate and UA-value in the high temperature generator. However, the system COP was improved, because thermal load in the system components was reduced. The COP and the cooling capacity was found to be improved as cooling water temperature decreased or chilled water temperature increased. The optimum ratio of solution distribution could be suggested by considering the COP, the cooling capacity and the highest temperature in the system, which is critical for corrosion.

  • PDF

LiBr-$H_2O$계 흡수식냉동기의 부식에 미치는 온도의 영향 (The Effect of Temperature on Corrosion of Absorption Refrigeration Systems Using LiBr-$H_2O$ Working Fluids)

  • 임우조;정기철;윤병두;강성수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.92-97
    • /
    • 2001
  • This paper was studied on the effect of temperature on corrosion of absorption refrigeration systems using LiBr-$H_2O$ working fluids. In the fresh water and 62 %lithium bromide solution at $70^{\circ}C$, polarization test of SS 400, Cu(Cl220T-OL) and Ni-Al bronze was carried out. And Polarization behavior, polarization resistance characteristics, corrosion rate(mmpy) and corrosion sensitivity of materials forming absorption refrigeration systems was considered. The main results are as following: As the experimental temperature increase, the change of corrosion rate of Ni-Al bronze become duller than SS 400 and Cu in 62 % lithium bromide solution. Open circuit potential of SS 400 is less noble than that of Cu and Ni-Al bronze in fresh water, but that becomes noble than Cu and Ni-Al bronze in 62 % lithium bromide solution. The corrosion sensitivity of Ni-Al bronze was controlled than that of Cu and SS 400 in 62% LiBr solution.

  • PDF

수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구 (An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube)

  • 설신수;이상용
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.

Water-Lithium bromide-Lithium nitrate계 흡수용액 개발 (Development of Absorption fluid with Water-Lithium bromide-Lithium nitrate system)

  • 오영삼;주우성;박달령;조원일;백영순;방효선
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.190-192
    • /
    • 1996
  • 본 연구는 기존의 Water-Lithium Bromide(H2O/LiBr) 용액에 비해 부식성이 낮은 Water-Lithium bromide-Lithium Nitrate계(H2O/LiBr-LiNO3)용액의 용해도, 증기압, 점도, 표면장력 등의 물리적 성질을 조사하였다. 또한 용해도가 가장 큰 최적의 혼합 몰비를 구하여 증기압 및 점도, 표면장력등의 물성을 구함으로써 흡수식 냉온수기용 홉수제 개발의 기본 자료를 확보하였다. 이러한 연구 결과로부터 다성분 Lithium 염 혼합물계로 이루어진 흡수용액 개발의 기초자료로 이용하고자 한다.

  • PDF