• Title/Summary/Keyword: Leveling System

Search Result 224, Processing Time 0.025 seconds

Hoop Energy Storage System(HESS) for Electric Power Utility (전력 계통에의 이용을 위한 후프 에너지 저장 시스템)

  • 백광현;정기형
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.173-178
    • /
    • 1995
  • Hoop Energy Storage System(HESS) for electric power utility were discussed laying primary stress on the diurnal load leveling of Korean electric power system. A number of potential storage technologies are outlined and possibility for real application of HESS was suggested. Primary system variables were determined on the basis of state of electric power demand-supply of 1994. As a prerequisite technology for HESS, noncontacting support using magnetic pressure and high power conversion were discussed.

  • PDF

Enhancement of network stability using flywheel Energy storage unit and circulating type cycloconverter (플라이휠과 순환전류형 싸이크로컨버터를 이용한 계통안정도 향상)

  • Ryu, Ho-Seon;Kim, Byung-Kweon;Whang, In-Ho;Lee, Heung-Ho;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.202-204
    • /
    • 1993
  • Appropriate control of real and reactive power flowing in and out from system can lead to considerable benefits : network stabilization, load leveling, voltage regulation etc. This paper presents how to control real and reactive power flow between an flywheel energy storage system and a power three phase network. The system compensating real and reactive power consists of control system and cycloconverter operating in the four quadrant modes.

  • PDF

Integrated Storage System For Automobile Production Line (자동차 생산라인을 위한 통합창고 시스템)

  • Kim, Duksu;Seo, Yoonho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.2
    • /
    • pp.1-8
    • /
    • 2014
  • The automobile manufacture is a typical integrated assembly production that the numerous parts are committed sequentially to the assembly line. In this type of automobile manufacture, WBS (white body storage) and PBS (paint body storage) are operated to adjust the production sequence and to buffer. Starvation (impossibility of production owing to the insufficient supply) or blocking (impossibility of production owing to the over capacity) could occur in some chance, hence, both storages (WBS, PBS) are integrated as a prevention. This system is called integrated storage. In this paper, we suggest the simulation model of 'WBS-PBS integrated storage' and methodology of operation considering both 'Color grouping' and 'Option leveling.'

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.

Development of Intelligent Force Reflection Joystick using Pneumatic Motor

  • Sungman Pyo;Insung Song;Kyungkwan Ahn;Soonyong Yang;Lee, Byungryong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.65.6-65
    • /
    • 2002
  • In teleoperation robotic system such as hydraulically actuated robotic excavator for dangerous area, the maneuverability and convenience is the most important part. Particularly the force information is important in dealing with digging and leveling operation in the tole-operated excavator. Excavators are also subject to a wide variation of soil-tool interaction forces. This paper proposes a new force reflecting joystick using pneumatic motor and a new algorithm for selecting force-reflecting gain in a velocity-force type bi lateral teleoperation system. The master system is electrical joystick with the same structure of that of real excavator. Particularly Pneumatic motor is used newly in...

  • PDF

A Study on the Thermal Characteristics of a $MgO/H_2O$ Chemical Heat Pump ($MgO/H_2O$ 계 화학식 열펌프의 열적 특성에 관한 연구)

  • ;;;;Yukitaka Kato
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.34-41
    • /
    • 2004
  • The chemical heat pump based on the Dehydration/Hydration process with a MgO/$H_2O$ system has been researched. The reactor bed could be expected to store the heat around 200∼37$0^{\circ}C$ by the dehydration reaction and to release the heat around 100∼16$0^{\circ}C$ by the hydration reaction under the heat amplification mode operation. The heat output rate of the heat pump system was evaluated using the experimentally determined parameters. The results show that 6∼50 W/kg of heat output and 0.5∼0.8 of heat recovery ratio are attainable. The heat pump will be applicable for a load leveling in a co-generation system by chemical storage of surplus heat at low heat demand and by supplying heat in the peak load period.

Development of a 0.5MW PCS for efficient connection operation of wind power system (풍력 발전시스템의 효율적인 연계운전을 위한 0.5MW급 PCS 개발)

  • Lee, Yun-Jae;Choi, Eun-Sik;Lee, Chung-Woo;Ryu, Kang-Yeul;Jo, Jang-Ho;Lee, Jin
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.498-500
    • /
    • 2012
  • According to the climatic characteristics of the wind power output is difficult to predict and a severe strain due to a change in output has been very influential in the grid. Jeju Hangwon wind farm, many of the wind generator is installed in a wide area because it is not have this device that artificially Smoothing is needed. In addition, By the requirements of the power company active power supply / control and improve power system reliability and energy storage during the peak demand for electricity using the energy stored in the power supply is needed. In this paper, Unit 12 in Jeju Hangwon demonstrated 0.5MW PCS and energy storage system associated with the wind through the stabilization of output and the leveling of output and test results will be introduced.

  • PDF

An Optimized File System for SSD (SSD를 위한 최적화 파일시스템)

  • Park, Je-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.2
    • /
    • pp.67-72
    • /
    • 2010
  • Recently increasing application of flash memory in mobile and ubiquitous related devices is due to its non-volatility, fast response time, shock resistance and low power consumption. Following this trend, SSD(Solid State Disk) using multiple flash chips, instead of hard-drive based storage system, started to widely used for its advantageous features. However, flash memory based storage subsystem should resolve the performance bottleneck for writing in perspective of speed and lifetime according to its disadvantageous physical property. In order to provide tangible performance, solutions are studied in aspect of reclaiming of invalid regions by decreasing the number of erasures and distributing the erasures uniformly over the whole memory space as much as possible. In this paper, we study flash memory recycling algorithms with multiple management units and demonstrate that the proposed algorithm provides feasible performance. The proposed method utilizes the partitions of the memory space by utilizing threshold values and reconfigures the management units if necessary. The performance of the proposed policies is evaluated through a number of simulation based experiments.

Hydropneumatic Modeling and Analysis of a Heavy Truck Cabin Air Suspension System (대형 트럭 캐빈 공기 현가장치의 유공압 모델링 및 해석)

  • Shin, Hang-Woo;Choi, Gyoo-Jae;Lee, Kwang-Heon;Ko, Han-Young;Cho, Gil-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.128-134
    • /
    • 2008
  • In this paper, a hydropneumatic modeling and analysis of a heavy truck cabin air suspension system is presented. Cabin air suspension system is a system which improves ride comfort of a heavy truck and it can reduce vibration between truck frame and cabin. The components of the system, air spring, shock absorber, leveling valve and full cabin system are mathematically modelled using AMESim software. Simulation results of components and full cabin system are compared with experimental data of components and test results of a cabin using 6 axis simulation table. It is found that the simulation results are in good agreements with test results, and the hydropneumatic model can be used well to predict dynamic characteric of heavy truck cabin air suspension system.

Orthodontic treatment of gummy smile by maxillary total intrusion with a midpalatal absolute anchorage system

  • Hong, Ryoon-Ki;Lim, Seung-Min;Heo, Jung-Min;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.43 no.3
    • /
    • pp.147-158
    • /
    • 2013
  • This article describes the orthodontic treatment of a 31-year-old Korean female patient with gummy smile and crowding. The patient showed excessive gingival display in both the anterior and posterior areas and a large difference in gingival heights between the anterior and posterior teeth in the maxilla. To correct the gummy smile, we elected to intrude the entire maxillary dentition instead of focusing only on the maxillary anterior teeth. Alignment and leveling were performed, and a midpalatal absolute anchorage system as well as a modified lingual arch was designed to achieve posterosuperior movement of the entire upper dentition. The active treatment period was 18 months. The gummy smile and crowding were corrected, and the results were stable at 21 months post-treatment.