• Title/Summary/Keyword: Level shift

Search Result 892, Processing Time 0.024 seconds

A Study on the Spatial Composition and Area Distribution Functional shift in the Community Center - Focused on the Cases in Gunpo, Gyeonggi-do - (주민센터의 '기능전환'에 따른 공간구성과 면적배분에 관한 연구 - 경기도 군포시 사례를 중심으로 -)

  • Juen, Mu-Yeon;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.2
    • /
    • pp.176-185
    • /
    • 2010
  • Due to Korean government's reduction policy of the level of local administration, the government tries to become smaller and more efficient organization and in accordance with this movement, they try to transfer the human power and work of the office of Eup, Myeon, Dong to the office of Si, Goon, Goo so that they can take administrative action quickly, increase the efficiency of administration by preventing the overlapping of administrative task, improve the administrative service toward the citizens and make a functional shift of Inhabitant Self-Government Center in a way that is aimed at improving the quality of life of the inhabitants by setting up cultural, welfare facilities and forming the local community. Hereupon I expect this study will help to show the ways of composing the space of community center, accommodating the various demands of inhabitants through appropriate area calculation of functional area, increasing the efficiency of government officers' administrative support and also will be the guide for the architectural designs of the community centers. For this purpose, I have investigated community centers of 8 Dongs out of 11 Dongs in Goon-po Si that was chosen to be operating the pilot program of the office of Eup, Myeon, Dong's functional shift and obtained excellent results. I have surveyed how the functional spaces are being used, interviewed the government officials, examined the size of the functional and required space with Building card of a plan and the analyzed results are as follows.

Association between Physical activity and Depressive Symptoms among Korean Male Workers (일개 제조업 남성근로자에서 신체활동과 우울증상과의 관련성)

  • Chae, Chang Ho;Park, Chulyong;Son, Jun Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.201-209
    • /
    • 2017
  • Objectives: This study was conducted to assess the association between level of physical activity and depressive symptoms among Korean male workers. Methods: A self-administered questionnaire was distributed and anthropometric measurements were conducted with 1,379 male workers during a general health check. From this data, we identified the general characteristics, levels of physical activity(IPAQ), and depressive symptoms(CES-D) of the study population. We conducted univariate logistic regression to verify the variables that affect depressive symptoms and multivariate logistic regression to calculate odds ratios. Results: Among the 1,379 male workers, 43.4% were in the insufficiently active group(IPAQ category 1) and 22.8% were in the depressive symptom group($CES-D{\geq}16$). The odds ratio(OR) for depressive symptoms was statistically higher in the insufficiently active group, workers aged over 30, the shift work group, and the unmarried group. Adjusted for those variables, the ORs for depressive symptoms were found to be 1.45(95% CI=1.25-2.11), 1.15(OR=1.15, 95% CI=1.08-1.99) and 1.75(95% CI=1.48-2.02), for the insufficiently active group, workers aged over 30, and the shift work group, respectively. Conclusions: We found physical inactivity, age, marital status, and shift work to be associated with depressive symptoms among male workers. This study supports the suggestion that physical activity can be helpful to reduce depressive symptoms among workers.

A Study on the Multiresolution Motion Estimation Adequate to Low-Band-Shift Method in Wavelet Domain (웨이블릿 변환 영역에서 저대역 이동법에 적합한 다해상도 움직임 추정에 관한 연구)

  • 조재만;김현민;고형화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.2C
    • /
    • pp.110-120
    • /
    • 2003
  • In this paper, we propose a Multiresolution Motion Estimation(MRME) adapted to Low-Band-Shift(LBS) method in wavelet domain. To overcome shift-variant property on wavelet coefficients, the LBS was previously proposed. This method which is applied to reference frame in video coding technique, has superior performance in terms of rate-distortion characteristic. However, this method needs more memory and computational complexity. In this paper, The computational complexity of the proposed method(LBS-MRME) is about 15.6% of that of existing method at 3-level wavelet transform. And although it has about 7 times as much as existing method's motion vector since each subband has different motion vector, it decreases motion compensated prediction error by detailed motion estimation, and then has better efficient coding performance. The experimental results with the proposed method showed about 0.3∼11.6% improvement of MAD performance in case of lossless coding, and 0.3∼3.0㏈ improvement of PSNR performance at the same bit rate in case of lossy coding.

A Maintenance Model Applying Loss Function Based on the Cpm+ in the Process Mean Shift Problem in Which the Production Volume Decreases (생산량이 감소하는 공정평균이동 문제에서 Cpm+ 기준의 손실함수를 적용한 보전모형)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.1
    • /
    • pp.45-50
    • /
    • 2021
  • Machines and facilities are physically or chemically degenerated by continuous usage. The representative type of the degeneration is the wearing of tools, which results in the process mean shift. According to the increasing wear level, non-conforming products cost and quality loss cost are increasing simultaneously. Therefore, a preventive maintenance is necessary at some point. The problem of determining the maintenance period (or wear limit) which minimizes the total cost is called the 'process mean shift problem'. The total cost includes three items: maintenance cost (or adjustment cost), non-conforming cost due to the non-conforming products, and quality loss cost due to the difference between the process target value and the product characteristic value among the conforming products. In this study, we set the production volume as a decreasing function rather than a constant. Also we treat the process variance as a function to the increasing wear rather than a constant. To the quality loss function, we adopted the Cpm+, which is the left and right asymmetric process capability index based on the process target value. These can more reflect the production site. In this study, we presented a more extensive maintenance model compared to previous studies, by integrating the items mentioned above. The objective equation of this model is the total cost per unit wear. The determining variables are the wear limit and the initial process setting position that minimize the objective equation.

A Study on the Three-Level Converter using Primary Auxiliary Circuit (1차측 보조회로를 이용한 Three-Level 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Cho, Kyu-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.972-981
    • /
    • 2008
  • A New ZVS(Zero Voltage Switching) and ZVZCS(Zero Voltage and Zero Current Switching) Three-Level Converter is proposed. The proposed converter presented in this paper used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the all switch. A primary auxiliary circuit, which consists of one coupled inductor, is added in the primary to provide ZVZCS conditions to primary switches. Many advantages including simple circuit topology high efficiency, and low cost make this converter attractive for high power applications. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 2kW(27V, 74A) 40 kHz IGBT based experimental circuit.

Robust Unit Root Tests with an Innovation Variance Break

  • Oh, Yu-Jin
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.1
    • /
    • pp.177-182
    • /
    • 2012
  • A structural break in the level as well as in the innovation variance has often been exhibited in economic time series. In this paper we propose robust unit root tests based on a sign-type test statistic when a time series has a shift in its level and the corresponding volatility. The proposed tests are robust to a wide class of partially stationary processes with heavy-tailed errors, and have an exact binomial null distribution. Our tests are not affected by the size or location of the break. We set the structural break under the null and the alternative hypotheses to relieve a possible vagueness in interpreting test results in empirical work. The null hypothesis implies a unit root process with level shifts and the alternative connotes a stationary process with level shifts. The Monte Carlo simulation shows that our tests have stable size than the OLSE based tests.

Efficiency Characteristic of Three-Level Converter (Three-Level 컨버터의 효율특성에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Lee, Eun-Young;Gye, Sang-Bum;Eom, Tae-Min;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.187-193
    • /
    • 2007
  • This paper presents the Efficiency Characteristic of Three-Level Converter. Three-Level DC/DC Converter Presented in this paper is used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switch. This converter reduces the voltage stress across the main switch to half of input voltage. This paper analyses the loss of each component and the various losses for efficiency variation. The result of the analysis are verified using 3kW prototype.

  • PDF

A study on the CICDR-TL(Coupled Inductor Current Doubler Rectifier-Three Level) DC/DC Converter with Phase Shift Control (위상이동 방식을 적용한 CICDR-TL(Coupled Inductor Current Doubler Rectifier-Three Level) DC/DC 컨버터에 관한 연구)

  • Lee, Dong-Hyun;Kim, Yong;Bae, Jin-Yong;Kim, Pill-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.159-162
    • /
    • 2004
  • The paper proposes the coupled inductor rectifier of Three Level DC/DC converter CICDR-TL(Coupled Inductor Current Doubler Rectifier-Three Level) achieves Zero Voltage Switching (ZVS) for the switches in a wide load range and Zero Current Switching (ZCS) in a light load range. Advantages and disadvantages of this topology compared to the conventional Center Tapped TL Converter are discussed. Experimental evaluation results obtained on a 27V 60A DC/DC converter prototype for the 1.8kW 40kHz IGBT based experimental circuit.

  • PDF

Three-Level ZVZCS DC/DC Converter using a Assistance Power Sources of the RailRoad Vehicles (철도차량 보조전원용 Three-Level ZVZCS DC/DC 컨버터)

  • Rho S.C.;Lim E.K.;Yang S.H.;Kim Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.880-885
    • /
    • 2003
  • Using a Assistance Power Sources of the Railroad Vehicles Three-Level ZVZCS DC/DC Converter is presented in this paper. The proposed three-Level DC/DC Converter Is to achieved zero voltage and zero current switching for the two Main switches. phase shift method is used a parastic capacitance by reverse recovery characteritics in a inner diode of the switching device. Also. using a diode second part of the Transformer by the simple auxiliary circuit for the achieved zero current switching of the Auxiliary switch. For the ZVZCS movement of the all switching devices is analyzed and verified under a 5kW, in the 100kHz switching frequency.

  • PDF

A Study on the Loss Analysis of Three Level Converter (Three Level 컨버터의 손 분석에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Yoon, Suk-Ho;Kim, Pill-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.177-182
    • /
    • 2002
  • This paper presents the loss analysis of Three Level Converter. Three Level DC/DC Converter presented in this paper used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switch. This converter reduces the voltage stress across the main switch to half of input voltage. This paper analyses the loss of each component and the various losses in the circuit assessed. The result of the analysis are verified using 2.5kW prototype.

  • PDF