• 제목/요약/키워드: Level meter

검색결과 485건 처리시간 0.022초

Curtain 감의 음향특성에 관한 연구(제2보) -투과율을 중심으로- (A Study on the Acoustical Characteristics of Curtain Fabrics (Part 2) -by Transmission Coefficient-)

  • 조현혹;정운자;강경자
    • 한국의류학회지
    • /
    • 제6권1호
    • /
    • pp.61-66
    • /
    • 1982
  • Succeeding to Report 1, to compare folded curtain fabrics with curtain fabrics, the sound pressure level (SPL) of folded curtain fabrics were measured by sound level meter. Transmission coefficient was calculated by the ratio of incidence sound intensity and transmission sound intensity. The relationship between these values and factors (drape coefficient, porosity) relating to the structure of curtain fabrics were investigated experimentally. The following results were obtained: 1. The transmission coefficient by ratio of sound pressure level was lower than that by ratio of sound intensity. 2. In folded curtain fabrics, difference of SPL was smaller and transmission coefficient generally decreased. 3. The relation between the porosity and transmission coefficient of curtain fabrics is given as plus correlation.

  • PDF

실내 공기 데이터 측정기 및 모니터링 시스템 (Indoor Air Data Meter and Monitoring System)

  • 전성우;임현근;박순모;정회경
    • 한국정보통신학회논문지
    • /
    • 제26권1호
    • /
    • pp.140-145
    • /
    • 2022
  • 고도화된 현대사회는 도시산업화와 대중교통으로 인한 대기오염 물질 중 미세먼지는 실외에서 실내로 유입되는 현상이 있다. 실내에서 사용하는 미세먼지 측정기는 제한적인 정보 제공과 오염 수치가 다르게 측정되어 사용자에게 원하는 데이터와 모니터링을 할 수 없는 문제점이 발생하고 있다. 이러한 문제점을 해결하기 위해 본 논문에서는 실내 공기 질 데이터 미세먼지와 초미세먼지인 Dust(PM1.0, PM2.5, PM10), VOC(Volatile Organic Compounds)와 PIR(Passive Infrared Sensor)로 미세먼지 측정기와 모니터링시스템을 설계 및 구현하였다. 측정기는 지정한 구역에 설치하여 미세먼지를 실시간 측정하고 Google Cloud Platform의 App Engine을 통하여 데이터 수집 및 저장하고 시각화하여 사용자에게 제공하는 미세먼지 측정기와 모니터링시스템을 제안한다.

소닉노즐의 유량측정 불확도 평가 (Evaluation of Flow Measurement Uncertainty of Sonic Nozzle)

  • 최해만;박경암;최용문;오연균;윤병로
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.601-606
    • /
    • 2001
  • Measurement uncertainty should be evaluated according to ISO/IEC 17025. In Flow measurement area, uncertainty evaluation scheme was applied to the reference flow meter, sonic nozzle. Uncertainty was calculated by evaluating various uncertainty factors affected in flow measurement. The expanded uncertainty of the sonic nozzle was 0.21 % (confidence level of 95 %). This evaluation example will be useful in flow measurement uncertainty determination of other flow meters.

  • PDF

화약산업의 발파 안전대책 -소음진동 및 안전거리 설정을 중심으로- (A Study of the Safe Measure on the Gun Powder Industries)

  • 안명석
    • 한국안전학회지
    • /
    • 제6권4호
    • /
    • pp.98-104
    • /
    • 1991
  • 본 연구는 국내외 문헌과 현장 데이타를 기준으로 하여 일부 외국 기술 자료를 인용 하여 정리 하였으며, 岩盤發破現場에서의 폭발사고에 대하여는 RION VM- l2B, LR-04Recoder등 소음·진동계를 이용한 안전진단 결과를 토대로 騷音振動에 따른 被害 및 防止對策을 위주로 기술하였고, 煙火發射現場에서의 一般安全守則과 Portable Sound Level-meter를 이용한 폭음측정 결과를 토대로 한 爆發騷音 및 Transite를 사용한 측정치를 정리하여 落下安定踞離 設定에 대하여 기술하였다.

  • PDF

농업용수 사용량 계측을 위한 전자파 표면유속계의 적용 (Application of microwave water surface current meter for measuring agricultural water intake)

  • 백종석;김치영;이기성;강현웅;송재현
    • 한국수자원학회논문집
    • /
    • 제53권12호
    • /
    • pp.1071-1079
    • /
    • 2020
  • 하천수의 통합적인 물관리를 위해서는 농업용수의 목적으로 취수되는 하천수량과 같은 기초자료의 확보가 필수적이다. 취입보를 통해 취수되는 하천수는 농업용수로를 통해 도수되는데, 계측지점의 특성에 맞는 취수량 계측방법이 필요하다. 본 연구에서는 만경강 유역 어우보의 농업용수로 도플러 효과를 이용해 표면유속을 산정하는 전자파 표면유속계를 적용하였는데, 주로 홍수기와 같이 고유량 상황에서 사용되고 있다. 저유량이나 고풍속에서는 표면유속이 단면 전체의 평균유속을 대변하기 어렵기 때문에 연중 지속적인 활용도가 낮다고 평가받고 있어, 농업용수로에서 전자파 표면유속계를 이용한 계측이 적합한지에 대한 검증이 필요한 상황이다. 전자파 표면유속계로 계측한 자료를 실측 유량자료와의 비교를 통해 농업용수로에서의 취수량 자료를 산정하였다. 농업용수로에서 최저유속 약 0.3 m/s, 최저유량 약 1.0 m3/s 이상시 전자파 표면유속계를 이용해 산정되는 일단위 유량은 기준유량 대비 경향성과 정확도가 높은 편인 것으로 확인되었고, 특히, 고유량일때 정확도가 높은 것으로 나타났다. 저유량에서는 양적인 측면에서는 유효한 결과를 얻을 수 있으나, 자료의 경향성이 불안정한 것으로 미루어 저유량시 표면유속으로 단면의 평균유속으로 산정하는 것에는 후속적인 연구가 필요할 것으로 판단한다. 본 연구를 통해 일정 유속 이상의 인공수로에서는 전자파 표면유속계를 통해 취수량을 산정하는 것이 적정한 것으로 사료되어 하천수 사용량 계측의 방안으로서 널리 보급되길 기대한다.

신생아집중치료실 내 인큐베이터 간호를 받는 미숙아가 경험하는 소음 수준 및 빈도 (Noise Level and Frequency Experienced by Premature Infants Receiving Incubator Care in the Neonatal Intensive Care Unit)

  • 주소현;김태임
    • Child Health Nursing Research
    • /
    • 제26권2호
    • /
    • pp.296-308
    • /
    • 2020
  • Purpose: The purpose of this study was to identify the noise level and frequency experienced by premature infants receiving incubator care in the neonatal intensive care unit (NICU). Methods: The participants were 20 premature infants receiving incubator care in the NICU of a university hospital in Daejeon Metropolitan city. The noise level was measured using a professional sound-level meter (ET-958, FLUS, Shenzhen, China) based on a noise classification table developed by the author. The data were analyzed with descriptive statistics, the t-test, analysis of variance, and Pearson correlation coefficients using SPSS for Windows version 22.0. Results: The average noise level experienced by premature infants receiving incubator care in the NICU was 51.25 dB (range: 45.0~81.7 dB). The frequency of noises was highest for factors related to nursing activities (40.3%), followed by human factors (29.1%), machine alarm sounds (20.1%), incubator operation (6.6%), and internal environmental factors (3.9%). Conclusion: According to the above results, the noise level experienced by premature infants receiving incubator care in the NICU exceeded the recommendations of the American Academy of Pediatrics. Therefore, it is necessary to develop an interventional program to reduce noise in the NICU, and to conduct follow-up studies to verify its effectiveness.

응급실의 소음도와 환자의 인지정도에 관한 연구 (A Study on the Noise Level and Patients' Perception of the Noise in Emergency Department)

  • 정승은;최창하
    • 기본간호학회지
    • /
    • 제5권2호
    • /
    • pp.341-352
    • /
    • 1998
  • The purpose of this study was to provide a bases for comfort of patient through of measuring the noise level in emergency room and grasping the perception to noise of inpatient. Data on noise level through sound level meter in ER and patients' perception of the noise through a structured questionnaire and were collected from August 21 to September 5 in 1998. And collected data were analyzed with SAS statistics progeam, descriptive statistic, t-test and ANOVA. The result of examination is as follows : 1. Among a noise level of measured highest was 64.6dB(A) in 'rounding of medical teams', the lowest was 54.8dB(A) in 'traffic noise from outside'. 2. The mean score of noise perception was 0.93. Among a kind of noise reported by the subjects, that which ranked highest was 'conversation of patients' caregiver and visitors'(1.75). The ranked lowest was 'noise of airconditioner'(0.59). 3. The relationship between perception of noise and subjects' characteristics was not significient. Therefore, based on this result, ways require to decrease the noise level in emergency department.

  • PDF

현미경의 길이표준 소급성 확립을 위한 배율 교정 시편 인증 (Certification of magnification standards for the establishment of meter-traceability in microscopy)

  • 김종안;김재완;박병천;엄태봉;강주식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.645-648
    • /
    • 2005
  • Microscopy has enabled the development of many advanced technologies, and higher level microscopic techniques are required according to the increase of research in nano-technology and bio-technology fields. Therefore, in many applications, we need to measure the dimension of micro-scale parts accurately, not just to observe their shapes. To establish the meter-traceability in microscopy, gratings have been widely used as a magnification standard. KRISS provides the certification service of magnification standards using an optical diffractometer and a metrological AFM (MAFM). They are based on different measurement principles, and so can give complementary information for each other. In this paper, we describe the configuration of each system and measurement procedures to certificate grating pitch values of magnification standards. Several measurement results are presented, and the discussion about them are also given. Using the optical diffractometer, we can calibrate a grating specimen with uncertainty of less than 50 pm. The MAFM can measure a grating specimen of down to 100 nm pitch value, and the calibrated values usually have uncertainty less than 500 pm.

  • PDF

지속적 경막외진통법후 Pressure Algometer에 의한 요통의 평가 (Evaluation of Backpain after Continuous Epidural Analgesia by Pressure Algometer)

  • 권영은;박성희;김인령;이준학;이기남;문준일
    • The Korean Journal of Pain
    • /
    • 제9권2호
    • /
    • pp.363-367
    • /
    • 1996
  • Background: Recently postoperative pain control with continuous epidural analgesia has been increased. This study aimes to evaluate backpain following continuous epidural analgesia by pressure threshold meter (algometer). Methods: After informed consent, 50 ASA physical status I or II patients undergoing elective gynecologic surgery were selected. After placing epidural catheter, patients received morphine 0.05mg/kg with 0.25% bupivacaine 5 ml followed by continuous infusion of 0.125% bupivacaine 100 ml with morphine 4 mg for 48 hours. backpain was measured by pressure algometer over lumbar paraspinalis at the L4 level, 5 and 7 cm from the midline on preoperative, operation day, 1st, 2nd, 3rd, and 4th postoperative days. Results: Postoperative mean pressure thresholds of were higher than preoperative value (p<0.05). Conclusion: The continuous epidural analgesia dose not provide or aggravate postoperative backpain, but it must be evaluated for long term follow-up.

  • PDF

가상현실 환경에서의 3차원 사운드 생성을 위한 거리 변화에 따른 구조적 머리전달함수 모델 (A Range Dependent Structural HRTF Model for 3-D Sound Generation in Virtual Environments)

  • 이영한;김홍국
    • 대한음성학회지:말소리
    • /
    • 제59호
    • /
    • pp.89-99
    • /
    • 2006
  • This paper proposes a new structural head-related transfer function(HRTF) model to produce sounds in a virtual environment. The proposed HRTF model generates 3-D sounds by using a head model, a pinna model and the proposed distance model for azimuth, elevation, and distance that are three aspects for 3-D sounds, respectively. In particular, the proposed distance model consists of level normalization block distal region model, and proximal region model. To evaluate the performance of the proposed model, we setup an experimental procedure that each listener identifies a distance of 3-D sound sources that are generated by the proposed method with a predefined distance. It is shown from the tests that the proposed model provides an average distance error of $0.13{\sim}0.31$ meter when the sound source is generated as if it is 0.5 meter $\sim$ 2 meters apart from the listeners. This result is comparable to the average distance error of the human listening for the actual sound source.

  • PDF