• Title/Summary/Keyword: Level meter

Search Result 483, Processing Time 0.027 seconds

Consideration about Ozone Generation in the Treatment Room While Treating a Patient (방사선 치료 시 치료실 내에서 발생하는 오존에 관한 고찰)

  • Kwak, Yong-Kuk;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.75-82
    • /
    • 2009
  • Purpose: Measure the ozone level in the treatment room while treating a patient so want to know the degree of contamination caused by ozone occurrence. Materials and Methods: Use the linear accelerator (Clinac 21EX, Varian, USA) with the ozone meter (series-200, aeroQual, New Zealand) and water phantom (Wellhofer, IBA, Germany) is irradiated the radiation so that measured the ozone generation level according to MU, dose-rate, SSD, field size, energy, delay time and put the ozone meter in the treatment room actually while treating a patient so measured the daily ozone level variation. Results: While irradiating the radiation, degree of ozone contamination wasn't affected by the energy but mostly in case of electron beam, ozone level was higher than photon beam. The higher dose-rate (0.016~0.025 ppm/hr), the farther SSD (0.018~0.030 ppm/hr), the wider field sizes (0.016~0.025 ppm/hr), the more MU (0.018~0.046 ppm/hr), it occurred high ozone level. Ozone decrement according to delay time changed the background level (0.016 ppm/hr) after elapsed time of 10 minutes from irradiating radiation. And daily ozone occurrence level in the treatment room was below ozone standard level 0.1 ppm/hr (average:0.06 ppm/8 hr) but it could confirm that ozone generation level was included the level (max:0.038 ppm/hr) above 0.02 ppm/hr which patient could perceive. Conclusion: Through ozone level according to variation of certain conditions, actually in the treatment room ozone generation level didn't damaged to patients or workers. Commonly peoples think that ozone was harmful gas but it thought that small amount of ozone generation level while treating a patient was beneficial in the treatment room through air purge action of pathogenic germ or virus sterilization.

  • PDF

Instrumentation Management of the Deep Soft Ground with Dredged Clay Reclaimed in the Upper (준설점토가 상부에 매립된 대심도 연약지반 계측관리)

  • Jung, Na-Young;Kang, Seung-Chan;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.67-78
    • /
    • 2022
  • In this study, the measurement results of the coastal deep soft ground buried in the upper part of the dredged clay were analyzed and compared with the current specification standards. Based on the results, a suitable proposal was suggested for the selection, installation, data arrangement, and analysis of each instrument used in the deep soft ground improvement construction. The pore water pressure meter has a range of 1.5 times or more of the expected measurement range, considering the field conditions of the soft ground. The groundwater level meter installed in the horizontal drainage layer checks the change in the groundwater level during the embanking as well as the performance of the catchment well and the horizontal drainage layer. Therefore, it is important to manage so that the groundwater level exists inside the horizontal drainage layer during embanking. It is enough to install the inclinometer in the gravel layer below the soft ground or weathered rock with an N value of 40 or more for the deep soft ground. It seems desirable to install a screw type for differential settlement meter. However, the screw type should not settle due to its own weight. Considering that it is a dredged landfill where subsidence occurs significantly, it is sufficient to manage the tolerance of leveling at about 10 mm (L is the one-way distance (km)).

Design and manufacture of horn lens antennas of 80 GHz MM wave FMCW radar for cryogenic fluids level measurement

  • Jeon, S.M.;Mun, J.M.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.29-33
    • /
    • 2022
  • Recently, development of a cryogenic fluids storage tank for storing or transporting liquid hydrogen is actively in progress. In cryogenic fluids storage tanks, hydrogen evaporates due to the extreme temperature difference inside and outside the tank. As the mass of the cryogenic fluids changes with continuous vaporization, the fluids level also changes. Therefore, there is need for a method of accurately measuring the level change in the storage tank. In the case of general cryogenic fluids, it is difficult to accurately measure the level because the dielectric constant is very low. As a method of measuring cryogenic fluids level with low dielectric constant, it can be used an Millimeter wave (MM wave) FMCW radar sensor. However, the signal sensitivity is very weak and the level accuracy is poor. In this paper, the signal sensitivity is improved by designing the horn lens antenna of the existing 80 GHz FMCW radar sensor. Horn lens antenna is fabricated by FDM/SLA type 3D printer according to horn and lens characteristics. The horn is used to increase the signal gain and the lens improves the signal straightness. This makes it possible to measure the level of cryogenic fluids with a low dielectric constant.

Flood control analysis of the sea dike at estuary. (하구방조제의 홍수조절 해석)

  • 서승덕
    • Water for future
    • /
    • v.10 no.2
    • /
    • pp.113-124
    • /
    • 1977
  • Alone the southwesten coast of Korean peninsula, the extensive available arable acreages suited for forming are found in the development of tidal flats in the geographically curved bays with a motable tidal emplitude. It was found that the developments of these tidal flats cover an estimated area more than 276,000ha. In this paper, a flood control system by Pul's Storage Indication Method and Pul's Graphical Method at Return Periods-50 yrs, design rainfall-267mm per 48hrs and design flood-926c.m.s. and at 0.2meter control height above the High Water Ordinary Spring Tide Level (+11.0m) was studied. At the result, the flood demage in the reservoir at Return Periods-50 yrs and the tidal level at H.W.O.S.T.L. were satisfied to the below E.L. 11.20m (Flood Level in the reservoir). Well skilled flood control technique and management and control of draining sluice gate should be required for the disaster prevention from the flood and tide damage.

  • PDF

Development and Performance of Automated Calibration System of Sound Level Meters (소음계 교정 자동화 시스템 개발 및 성능평가)

  • 김용태;조문재;이용봉;서재갑
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

The Measurement of Firing Noise of K2 Rifle at Close Distance (근접 측정에 의한 K2 소총 사격음의 측정)

  • 이윤
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1123-1128
    • /
    • 2004
  • An experimental study on firing noise of K2 rifle was performed. Firing noises of K2 rifle were measured at close distance to rifle. Firing noise of K2 rifle which made in Korea, has not measured before. The measurement of firing noise at close distance is not simple, because the amplitude of firing noise is much bigger than the measuring limit of ordinary sound level meter even though it uses a signal attenuator. The measurement of firing noise at close distance is necessary for noise source positioning and for obtaining the sound power of K2 rifle. By this experimental study, the firing noise levels of K2 rifle at different positions are obtained and these data can be used to Predict the sound pressure level at any distance from muzzle of the rifle. Also these data can be used to calculate the threshold shift of gunner's ear.

Tendency of Calibration and Test for Acoustic Field in KRISS (KRISS 에서 수행된 음향관련 교정 및 시험 검사 동향)

  • Suh, Jae-Gap;Jung, Sung-Soo;Jho, Moon-Jae;Suh, Sang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1767-1771
    • /
    • 2000
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 1999. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

Development of a sea environmental monitoring system using wire and wireless communication ($\cdot$무선통신을 이용한 해양환경 모니터링 시스템의 개발)

  • 김진호;한정만;김상봉
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.160-165
    • /
    • 1996
  • This paper introduces a sea environmental monitoring system for measuring pH,DO, level and temperature. This system is developed using a personal computer(PC) and multiple single board computers. A PC communicates with the single board computers by awireless communication method and transfers data to another personal computer for processing data by a modem. The values of pH,Do,level and temperature, which are basic components to estimate sea environment, are real-timely processed in the single board computer at each stations, and transferred to the monitoring PC. These data are graphically shown on the PC monitor and logged on the data processing system in the form of file. Using the wire and wireless communication system, user can constantly analyze the acquired data and detect the sea contamination.

  • PDF

Characterization of one Time-Sequential Stereoscopic 3D Display - Part II: Quick Characterization Using Homogeneity Measurements -

  • Pierre, Boher;Thierry, Leroux;Collomb-Patton, Veronique
    • Journal of Information Display
    • /
    • v.11 no.2
    • /
    • pp.63-67
    • /
    • 2010
  • In these authors’ previous paper, it was shown that grey-level stability is one of the main drawbacks of the time-sequential stereoscopic 3D display. In the present study, it was demonstrated that a videoluminance meter can be used to rapidly and easily check the quality of such display. A dedicated pattern was applied to simultaneously check the effect of the grey level on the other eye and the effect of the temporal synchronization. The results were compared with those provided by a temporal model of the display, which was obtained by measuring its temporal behavior. The visual impact of the grey-level instabilities was precisely quantified, and they were found to be a major source of imperfections for the aforementioned display.

Trap Level Study of Alq3 for OLED with Debye Dielectric Relaxation (Debye 이론을 이용한 유기 EL용 Alq3계 재료의 Trap Level 측정)

  • Jeong, Yong-Seok;Jeong, Yeon-Tae;Kim, Jong-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.668-672
    • /
    • 2004
  • Upon Debye's dielectric relaxation theory, we tried simple determination method of trap level in organic EL materials. From dielectric measurements in the 20 Hz - 1 MHz frequency range and in the 150 K - 320K temperature range, the depth of traps in Alq$_3$ filled with remaining electrons was determinated. Comparing to other determination techniques like TSL, or TL, the apparatus all we need is just simple LCR meter, thermometer and cooling method(liquid nitrogen). The mean activation energy is about 0.20 eV. It is in good agreement with previous determinations by other techniques like TSL. This results consolidate the validity of Burrow's transport mechanism model. Further intensified experiment with UV light on the dielectric absorption(Photodipolair effect) was nevertheless disturbed by the photoconductivity component.