• 제목/요약/키워드: Level control

검색결과 17,984건 처리시간 0.04초

OPTIMIZATION OF THE PARAMETERS OF FEEDWATER CONTROL SYSTEM FOR OPR1000 NUCLEAR POWER PLANTS

  • Kim, Ung-Soo;Song, In-Ho;Sohn, Jong-Joo;Kim, Eun-Kee
    • Nuclear Engineering and Technology
    • /
    • 제42권4호
    • /
    • pp.460-467
    • /
    • 2010
  • In this study, the parameters of the feedwater control system (FWCS) of the OPR1000 type nuclear power plant (NPP) are optimized by response surface methodology (RSM) in order to acquire better level control performance from the FWCS. The objective of the optimization is to minimize the steam generator (SG) water level deviation from the reference level during transients. The objective functions for this optimization are relationships between the SG level deviation and the parameters of the FWCS. However, in this case of FWCS parameter optimization, the objective functions are not available in the form of analytic equations and the responses (the SG level at plant transients) to inputs (FWCS parameters) can be evaluated by computer simulations only. Classical optimization methods cannot be used because the objective function value cannot be calculated directely. Therefore, the simulation optimization methodology is used and the RSM is adopted as the simulation optimization algorithm. Objective functions are evaluated with several typical transients in NPPs using a system simulation computer code that has been utilized for the system performance analysis of actual NPPs. The results show that the optimized parameters have better SG level control performance. The degree of the SG level deviation from the reference level during transients is minimized and consequently the control performance of the FWCS is remarkably improved.

3상 3레벨 인버터의 중성점 제어를 이용한 고조파 왜율 저감 효과 (The effect of Harmonic Distortion Reduction on Three Phase Three level Inverter Using Neutral Point Control)

  • 김정규;양오
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.90-94
    • /
    • 2018
  • In this paper, we applied a three-level T-type inverter with the one more voltage level than two-level inverter. However, the three-level T-type inverter has a systematic problem with voltage unbalances. So neutral point control is essential. Therefore, the voltage unbalance problem of the three - phase inverter was confirmed to be controlled within 5V using the neutral point control algorithm in charge and discharge mode. In addition, total harmonic distortion was reduced in three phases (u phase, v phase, w phase) when neutral point control was performed in charging mode and also in three phases (u phase, v phase, w phase) in discharge mode. In this paper suggests a neutral point control algorithm to solve the voltage unbalance of a three-level T-type inverter, and shows the improvement of the performance of the proposed algorithm through experiment.

발효기 하드웨어 변환을 이용한 용존산소 제어 (Feedback Control of Dissolved Oxygen with Hardware Modification of Fermenter)

  • 이중헌;이인영;박영훈
    • KSBB Journal
    • /
    • 제15권3호
    • /
    • pp.280-284
    • /
    • 2000
  • The simple imcroprocessor device was provided for the control of dissolved oxygen(DO) level. The DO analog signal output from fementer was used as a measurement variable and the agitation speed of fermenter was used as a manipulatio variable. Agitation speed was manipulated to maintain DO level above 10% of saturation condition during cell growth period with microprocessor. Since the experimental resultsshowed that the DO level was maintained above 10% and agitation speed was inverse proportional to DO level ithis simple control device can be used for the DO control of fermenter.

  • PDF

원전 증기발생기 수위제어 디지탈화 및 적응에 관한 연구 (A study on the digitalize and application of Steam Generator level control system for nuclear power plant)

  • 문병희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.265-267
    • /
    • 1993
  • A control for Steam Generator (S/C) level is very difficult by automatic control mode but also manual control node during plant start up and/or low power level operation with the analog control system because of a non-nominal process responce. The goal of this study is to improve and computerize and applicate for KO-RI #1 Steam Generator level control system.

  • PDF

Tile Level Rate Control for High Efficiency Video Coding (HEVC) on Multi-core Platform

  • Marzuki, Ismail;Ahn, Yong-Jo;Sim, Donggyu
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2015년도 추계학술대회
    • /
    • pp.147-148
    • /
    • 2015
  • This paper proposes a tile level rate control for High Efficiency Video Coding (HEVC). The proposed tile level rate control is designed by considering the multi-core platform of tile in HEVC. The proposed tile level rate control allocates the number of bits for each tile based on the predetermined weight generated from the current picture level rate control. According to the experimental results, the proposed tile level rate control for HEVC on multi-core platform loses negligibly the bitrate accuracy about 0.07% on average over the reference software HM-14.0.

  • PDF

신속제조환경에서의 새로운 생산입력통제방식에 관한 연구 (A Study of New Production Input Control in an Agile Manufacturing Environment)

  • 김현수
    • 대한산업공학회지
    • /
    • 제23권4호
    • /
    • pp.699-708
    • /
    • 1997
  • Production control is usually composed of due-dote assignment, production input control, and priority dispatching rule. A production input control(PIC) is mainly to control the WIP level on the shop floor. On the other hand, a priority dispatching rule(PDR) is mainly to control the tardiness/earliness of on order and number of tardy jobs. Therefore, if we select a particular PIC which can control only a particular performance measure(i.e., tardiness), it may cause worsening other performance measure(i.e., WIP level, shopfloor time, etc.) This newly developed production input control, DRD(Dual Release-Dates), is mainly designed to control the WIP level on the shop floor by employing two different release-dates of an order(earliest release. date and latest release-date and the release condition (relationship between the current WIP level and the pre-defined maximum WIP level) while trying to meet the due-date of the order.

  • PDF

전자급수기에 관한 연구 (System Design of an Electronic Watering Device)

  • 박규태
    • 대한전자공학회논문지
    • /
    • 제10권5호
    • /
    • pp.1-6
    • /
    • 1973
  • 본논문은 자동급수기의 설계 및 제작연구를 한 것으로 digital scanning circuits를 이용하여 10개의 probe를 차례로 scanning하여 지표의 습도를 검출하여 reference level과 비교하여 필요한곳에 자동적으로 급수하도록 설계하였다. 이 system의 control을 위하여 main clock oscillator와 controloscillator를 사용하였고 control circuit로는 programmable unijunction transistor를 이용하여 reference level을 조절하게하여 임의의 원하는 습도에 급수하도록 하였다. 제작된 급수재는 모래의 습도가 6%에서 51%로 변화시키면서 실험하여 언제나 input level이 reference level보다 약 0.6V보다 높을때 완전동작하였으며 reference level은 임의로 조절할 수 있었다.

  • PDF

연속식 가열로의 Level 2 제어 시스템 설계 (Design of Level 2 Control System for Continuous Reheat Furnaces)

  • 유보현;이재용;임동렬;차재민;염충섭
    • 시스템엔지니어링학술지
    • /
    • 제12권1호
    • /
    • pp.113-120
    • /
    • 2016
  • Steel in a continuous reheat furnace is heated to higher temperature to be treated in the rolling steel process. Due to this reason the continuous reheat furnace system requires an optimal control system to adjust the temperature inside the furnace. Level 2 control systems for continuous reheat furnaces generate automatic heating set points for the level 1 system of the furnace based on the mathematical thermal model which can give a good estimation of steel heating inside the furnace and is used to adjust heating requirements to optimize furnace combustion. For the current study the analytic methodology based on the design procedure from the systems engineering to develop new level 2 control system of a continuous reheat furnace was proposed. The system analysis and the requirements of the level 2 control system were derived using the unified modeling language (UML) 2.0, and the design of database and the graphic user interface (GUI) for the level 2 control system were conducted.

The Effect of Cognitive Emotional Control on Happiness Levels

  • Kim, Jungae;Kim, Milang
    • International Journal of Advanced Culture Technology
    • /
    • 제9권1호
    • /
    • pp.143-151
    • /
    • 2021
  • This study was a cross-sectional descriptive research to analyze the effects of sub-factors of cognitive emotional control on happiness levels. The participants of the study were 201 men and women in their 20s, and data were collected online from January 1 to 15 collected data were, 2001 using structured cognitive control and happiness level questionnaires. The collected data were conducted Independent t-test, Pearson correlation analysis, simple regression analysis, multiple regression Analysis, hierarchical regression analysis using SPSS 18.0 statistic program. As a result, the study appeared that the level of happiness by gender does not differ, and cognitive emotional control affected 58.5%. The average of cognitive emotional control was higher for all men, but women were higher than men in criticized others. Also, acceptance was the sub-factor of emotional control that most affected the level of happiness (β=-.587, p<0.01). Based on the results of this study, it is suggested that a systematic program on subject of acceptance, a sub-factor of cognitive emotional control, should be developed to improve the level of happiness.

화력 발전소 드럼수위의 퍼지-PI 캐스케이드 제어 (Fuzzy-PI Cascade Control of Drum Level of Boiler in Thermal Power Plan)

  • 변승현;조지용;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.458-460
    • /
    • 1998
  • The drum level control is initiated by 1-element manual control, and then the control mode is changed to 1-element automatic control mode. Finally, the drum level control is changed to 3-element automatic control mode by the logic based on pre-defined threshold of main steam flow. In terms of plant automation, the automatic 1-element control mode is required from the start-up of boiler. In this paper, the fuzzy controller is adopted for automatic 1-element control of drum level from start-up. It is suggested that the fuzzy controller is used in 1-element control, and the fuzzy-PI cascade controller is used in 3-element control. Finally, the validity of suggested control scheme is shown via simulation.

  • PDF