• Title/Summary/Keyword: Lens of the Eye

Search Result 361, Processing Time 0.032 seconds

SKIN ABSORBED DOSES FROM FULL MOUTH STANDARD INTRAORAL RADIOGRAPHY IN BISECTING ANGLE AND PARALLELING TECHNIQUES (각이등분법 및 평행법에 의한 전악 구내 표준 촬영시 두경부 피부 흡수선량 비교)

  • Kim Ae-Ji;Nah Kyung-Soo;Doh Shi-Hong;Kim Hyun-Ja;Yoo Meong-Jin
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.315-333
    • /
    • 1990
  • This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography (l4 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator(60㎜ in diameter, 20㎝ in length) and rectangular collimator(35㎜ × 44㎜, 40㎝ in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rates of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling techniuqe, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  • PDF

Eyes and Vision of the Bumblebee: a Brief Review on how Bumblebees Detect and Perceive Flowers

  • Meyer-Rochow, V.B.
    • Journal of Apiculture
    • /
    • v.34 no.2
    • /
    • pp.107-115
    • /
    • 2019
  • Bumblebees have apposition compound eyes (one on either side of the head) of about 6,000 ommatidia and three small single-lens ocelli on the frons of their head capsule. The surface of the eye is smooth and interommatidial hairs, as in the honeybee, are not developed. Each ommatidium (approx. 26 ㎛ in diameter) is capped by a hexagonal facet and contains in its centre a 3 ㎛ wide, columnar light-perceiving structure known as the rhabdom. Rhabdoms consist of thousands of regularly aligned, fingerlike microvilli, which in their membranes contain the photopigment molecules. Axons from each ommatidium transmit the information of their photic environment to the visual centres of the brain, where behavioural reactions may be initiated. Since bumblebee eyes possess three classes of spectrally different sensitivity peaks in a ratio of 1:1:6 (UV= 353 nm, blue= 430 nm and green=548 nm) per ommatidium, they use colour vision to find and select flower types that yield pollen and nectar. Ommatidial acceptance angles of at least 3° are used by the bumblebees to discriminate between different flower shapes and sizes, but their ability to detect polarized light appears to be used only for navigational purposes. A flicker fusion frequency of around 110Hz helps the fast flying bumblebee to avoid obstacles. The small ocelli are strongly sensitive to ultraviolet radiation and green wavelengths and appear to act as sensors for light levels akin to a photometer. Unlike the bumblebee's compound eyes, the ocelli would, however, be incapable of forming a useful image.

A Study on the Shielding of Orbit by 3D Printed Filament in Brain CT (Brain CT검사 시 3D프린터 필라멘트에 따른 수정체 차폐 연구)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.101-108
    • /
    • 2021
  • The CT can accurately present the anatomical structure of an organ in the human body, and the resolution of the image is excellent. On Brain CT examination, the radiation sensitivity of the orbit is high and it is subject to many exposure effects. To reduce exposure dose of lens, this study compares change of exposure dose and shielding rate about non-shielding and shielding in a way of using two shielding materials, bismuth and tungsten. In this study, we used bismuth and tungsten filament as shielding materials made by 3D printing to measure the exposure dose according to the materials thickness and each of slices. To compare each shielding rate, 1 mm to 5 mm of two materials was measured with the head phantom fixed and the Magicmax universal dosimeter placed on the eye when the shielding material is not placed, and the shielding material is placed on it. In the 1 mm thick filament, the bismuth filament showed 26.8% and the tungsten filament showed 43.1% shielding rate. Therefore, tungsten presents much greater shielding effect than bismuth.

Development of Defects Detecting System for Corrugated Board, Mill Application, and Changes of Production Defects Ratio (골판지 불량 검색 시스템 개발, 현장적용과 생산 불량률 변화)

  • Jeong, Jin-Mo;Min, Kyung-Eun;Kim, Mun-Sung;Park, Jong-Moon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.40 no.2
    • /
    • pp.37-42
    • /
    • 2008
  • Defects of corrugated board were limiting factors to the corrugated industry's growth. On-line detecting systems of defects are beneficial to increase profits of the corrugated board companies by reducing base paper consumption, increasing process reliability, and increasing productivity. By replacing naked eye inspection of defects to a defects detecting system, continuous inspection without fatigue may guarantee final products quality. The system was developed, which was consisted of line scan CCD camera, lens, illuminating parts, high speed image processor, software, various input parts, and output parts. First installation location of the system was at before fluting process after base paper unwinding, and surface of liner board was inspected by the system. Second installation location was after fluting process and combining process for liner board. Production loss includes ragged appearance of edge, irregular flute shape, wrong combination of flute, score cracking, defects in base paper, and flute cracking. The production loss was analyzed before and after the system installation at a commercial domestic mill. The production loss ratio was defined as a production loss weight per total production weight. The production loss ratio before the installation was decreased a lot from 1.28%(during 3 months before installation) to 0.76%(during 12 months after the first installation) and to 0.25%(during 6 months after the second installation).

The Analysis of Binocular Vision Function by measuring Accommodative Convergence(AC/A) (조절성 폭주비(AC/A) 측정에 의한 양안시 기능 분석)

  • Kang, In-San;Seo, Yong-Won;Choi, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.159-164
    • /
    • 2005
  • Accommodation and convergence is combination movement which is closely connected with each other. When one of them is stimulated, both of functions occur at the same time. Specially, the convergence by the accommodation's stimulation is called as accommodative convergence. That has excess or deficiency according to refraction state of eye. This study was performed by using both of Gradient method and Heterophoria method to 41 adults who have no any ophthalmic disease. 1. As the result of investigation about the distribution of heterophoria at distance, there were orthophoria of 5 subjects, exophoria of 32 and esophoria of 4. Exoporia occupied at the hightest rate. The distribution of heterophoria at near cover a wider range more than at distance. 2. When we measured the horizontal heterophoria amount in the state of relaxation of accommodation power of lens, exophoria amount increased in case of 38 subjects. 3. The person who has $4{\sim}6{\Delta}/D$ which conform to normal AC/A ratio occupied 27 subjects(66%) in Heterophoria method and 16(39%) in Gradient method, respectively.

  • PDF

Comparison of the Size of objects in the Virtual Reality Space and real space (가상현실 공간상에서 물체의 크기와 실제 크기간의 비교연구)

  • Kim, Yun-Jung
    • Cartoon and Animation Studies
    • /
    • s.49
    • /
    • pp.383-398
    • /
    • 2017
  • Virtual Reality contents are being used as media in various fields. In order for the virtual reality contents to be realistic, the scale of the objects in the virtual reality must be the same as the actual size, and the user must feel the same size. However, even if the size of the character in the virtual reality space is made equal to the size in comparison with the size of the character in the reality, the distortion of the size can occur when the user looks at the object in the image with the HMD. In this paper, I investigate the requirements related to size in virtual reality, and try to find out what difference these requirements have in virtual reality and how the difference affects users. Experiments and surveys to compare the size of objects in virtual reality space and the size of objects in real space were conducted to investigate how scale distortion occurs at distant and near places. I hope that this paper will be a useful research for virtual reality developers.

Keratitis by Acanthamoeba triangularis: Report of Cases and Characterization of Isolates

  • Xuan, Ying-Hua;Chung, Byung-Suk;Hong, Yeon-Chul;Kong, Hyun-Hee;Hahn, Tae-Won;Chung, Dong-Il
    • Parasites, Hosts and Diseases
    • /
    • v.46 no.3
    • /
    • pp.157-164
    • /
    • 2008
  • Three Acanthamoeba isolates (KA/E9, KA/E17, and KA/E23) from patients with keratitis were identified as Acanthamoeba triangularis by analysis of their molecular characteristics, a species not previously recognized to be a corneal pathogen. Epidemiologic significance of A. triangularis as a keratopathogen in Korea has been discussed. Morphologic features of Acanthamoeba cysts were examined under a microscope with differential interference contrast (DIC) optics. Mitochondrial DNA (mtDNA) of the ocular isolates KA/E9, KA/E17, and KA/E23 were digested with restriction enzymes, and the restriction patterns were compared with those of reference strains. Complete nuclear 188 and mitochondrial (mt) 16S rDNA sequences were subjected to phylogenetic analysis and species identification. mtDNA RFLP of 3 isolates showed very similar patterns to those of SH621, the type strain of A. triangularis. 16S and 18S rDNA sequence analysis confirmed 3 isolates to be A. triangularis. 18S rDNA sequence differences of the isolates were 1.3% to 1.6% and those of 16S rDNA, 0.4% to 0.9% from A. triangularis SH621. To the best of our knowledge, this is the first report, confirmed by 18S and 16S rDNA sequence analysis, of keratitis caused by A. triangularis of which the type strain was isolated from human feces. Six isolates of A. triangularis had been reported from contaminated contact lens cases in southeastern Korea.

Development of Identification Method of Rice Varieties Using Image Processing Technique (화상처리법에 의한 쌀 품종별 판별기술 개발)

  • Kwon, Young-Kil;Cho, Rae-Kwang
    • Applied Biological Chemistry
    • /
    • v.41 no.2
    • /
    • pp.160-165
    • /
    • 1998
  • Current discriminating technique of rice variety is known to be not objective till this time because of depending on naked eye of well trained inspector. DNA finger print method based on genetic character of rice has been indicated inappropriate for on-site application, because the method need much labor and skilled expert. The purpose of this study was to develops the identification technique of polished rice varieties using CCD camera images. To minimize the noise of the captured image, thresholding and median filtering were carried out, and edge was extracted from the image data. Image data after pretreatment of normalize and FFT(fast fourier transform) were used for library model and feedforward backpropagation neural network model. Image processing technique using CCD camera could discriminate the variety of rice with high accuracy in case of quite different rice of shape, but the accuracy was reached at 85% in the similar shape of rice.

  • PDF

Analysis of changes in ocular function according to beats per minute (BPM) (분당비트수(BPM)에 따른 안기능 변화 분석)

  • Bong-Hwan Kim;Sun-Hee Han;Chan-heum Kang;Hyeon-seok Lee;Dong-uk Kwon;Chae-won Park;Hyung-Soo Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1639-1643
    • /
    • 2023
  • Purpose. We wanted to find out how the changes in brain function affected by the beats per minute (BPM) of music affected visual function. Methods. The subjects were 40 people in their 20s (30 men, 10 women) with no eye disease, strabismus, amblyopia and a corrected visual acuity of 1.0 or higher. Wearing headphones while excluding surrounding noise as much as possible, we played music while adjusting the beat rate at 40 BPM intervals from 80 to 200 BPM. Then, pupil size measurement, lag of accommodation test, and minus lens addition method maximum accommodation test were performed and analyzed. Results. As a result of analyzing changes in visual function according to beats per minute [BPM], it was found that although sound can be consciously affected, it does not directly affect visual function significantly in terms of accommodative lag and changes in pupil size. It was confirmed that the effect was limited to the maximum accommodation. Conclusions. In clinical practice, it is necessary to conduct a refraction test while keeping in mind that there are changes in visual function depending on the BPM of surrounding sounds.

A study of the manual procedure of ocular prosthesis (의안의 제조 방법에 관한 연구)

  • Kim, Jai Min;Park, Dong Hwa;Yoo, Geun Chang;Kim, Soon Ae;Cho, Seung Kwon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.95-99
    • /
    • 2002
  • To investigate the manual procedure for custom fitting of ocular prosthesis and the cytotoxicity induced by extract solution of prosthetic eye, this study was performed. These procedures included the trial fitting of the wax model, impression molding, the an of iris color duplication, sclera mold made from the prosthetic wax model, scleral tints and vascular pattern, finishing and polishing. Inhibition of cell growth for extract solution was measured by MTT assay. Extract solution did not show the cytotoxicity. This study suggests that the manual procedure for custom fitting of ocular prosthesis is good for education of students.

  • PDF