• Title/Summary/Keyword: Lens Radiation Dose

Search Result 73, Processing Time 0.02 seconds

Whole brain radiotherapy using four-field box technique with tilting baseplate for parotid gland sparing

  • Park, Jaehyeon;Yea, Ji Woon
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the efficacy and feasibility of four-field box whole brain radiotherapy (FB-WBRT) with tilting baseplate by comparing bilateral WBRT (B-WBRT). Methods and Materials: Between March 2016 and September 2018, 20 patients with brain metastases underwent WBRT using the four-field box technique. WBRT is performed with a dose of 30 Gy in 10 fractions daily. Two computed tomography simulations per person were performed. One was in the traditional supine position for B-WBRT and the other by applying the tilting acrylic supine baseplate to elevate the head by 40° for FB-WBRT. The B-WBRT used the field-in-field technique, which is the most commonly used method in our institution. The FB-WBRT comprised anterior, posterior, and bilateral beams. A wedge was applied in anterior and posterior fields to compensate for skull convexity. Results: The average of Dmean of both parotid glands was 10.2 Gy (range, 3.8 to 17.8 Gy) in B-WBRT and 5.4 Gy (range, 2.0 to 11.7 Gy) in FB-WBRT (p < 0.05). Compared to B-WBRT, FB-WBRT reduced the mean dose of the right and left parotid glands from 10.1 Gy to 4.9 Gy and from 10.4 Gy to 5.8 Gy, respectively (p < 0.05). Further, V5, V10, V15, V20, and V25 for the parotid gland decreased significantly in FB-WBRT (p < 0.05). The Dmax and Dmean of lens decreased according to the dose-volume histogram. Conclusion: Compared to B-WBRT, FB-WBRT with a tilting baseplate is a simple and effective method that takes feature of noncoplanar beam to protect the parotid gland.

Study of overlapping setting up of Planning Target Volume for Improving Target Coverage adjacent Organ At Risk (손상위험장기에 인접한 표적 Coverage 개선을 위한 Planning Target Volume 중복 설정에 관한 연구)

  • Lee, Jung Woong;Kim, Bo Kyum;Mun, Jun Ki;Woo, Hun;Lee, Yang Hoon;Jeon, Chang Woo;Lee, Jea Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.33-41
    • /
    • 2019
  • Purpose: The purpose of this study is to improve the reduction of coverage of PTVs adjacent to organ at risk (OAR) by setting up overlapping Planning Target Volume (PTV) during Volumetric Modulated Arc Therapy(VMAT). Materials and Methods: In patients who received Whole Brain, Gall Bladder and Rectum radiation therapy, We compared the cover change, maximum dose, Homogenicity Index and Conformity Index of PTV and also compared the maximum dose and average dose change of Organ At Risk by organizing treatment plans that are not applied overlaped PTV and treatment plans that are applied overlaped PTV in areas where coverage is insufficient. Results: overage of treatment plans with overlapping PTVs was increased in all patients, and overall coverage was also increased in each of the four patients. The maximum dose for PTV was increased in five patients, and the Homogenicity Index and Conformity Index for all patients did not differ much. The maximum dose of the lens was increased by 1.12 times, and the maximum dose was decreased in two patients for brain stem. The mean dose of the eyeball was increased by a maximum of 1.15 times, and there was no significant difference between both parotid gland. In case of gallbladder cancer patients, the mean dose in the liver and colon was decreased, and the mean dose in the duodenum was increased. In the case of rectal cancer patients, the mean dose was reduced for both femur and bladder set as OARs. The overall MU was shown to be similar in four patients, excluding one. Conclusion: If the critical dose of OAR is considered and used properly, I think it is a useful way to improve coverage of PTV.

A Study on the Comparative Analysis of Images and Doses According to Tube Orientation During Anterior-Posterior Axial Projection Examination of the Skull (머리뼈 전-후 축 방향검사 시 Tube 방향설정에 따른 표면선량과 영상분석에 관한 연구)

  • Jeong, Sung-Hun;Yoo, Je-hyeon;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.301-306
    • /
    • 2021
  • The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town's examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37° in the cathode direction and 30° and 37° in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30° and 37° The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

A Study on the Patient Exposure Doses from the Panoramic Radiography using Dentistry (치과 파노라마 촬영에서 환자의 피폭선량에 관한 연구)

  • Park, Ilwoo;Jeung, Wonkyo;Hwang, Hyungsuk;Lim, Sunghwan;Lee, Daenam;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 2013
  • This study estimate radiation biological danger factor by measuring patient's exposed dose and propose the low way of patient's exposed dose in panoramic radiography. We seek correcting constant of OSL dosimeter for minimize the error of exposed dose's measurement and measure the Left, Right crystalline lens, thyroid, directly included upper, lower lips, the maxillary bone and the center of photographing that indirect included in panoramic radiography by using the human body model standard phantom advised in ICRP. In result, the center of photographing's level of radiation maximum value is $413.67{\pm}6.53{\mu}Gy$ and each upper, lower lips is $217.80{\pm}2.98{\mu}Gy$, $215.33{\pm}2.61{\mu}Gy$. Also in panoramic radiography, indirect included Left, Right crystalline lens's level of radiation are $30.73{\pm}2.34{\mu}Gy$, $31.87{\pm}2.50{\mu}Gy$, and thyroid's level of measured exposed dose can cause effect of radiation biological and we need justifiable analysis about radiation defense rule and substantiation advised international organization for the low way of patient's exposed dose in panoramic radiography of dental clinic and we judge need the additional study about radiation defense organization for protect the systematize protocol's finance and around internal organs for minimize until accepted by many people that is technological, economical and social fact by using panoramic measurement.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

Patient Exposure Dose Reduction in Coronary Angiography & Intervention (심혈관조영술 및 중재술 시 환자 선량 감소방안)

  • Lim, Do-Hyung;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.69-76
    • /
    • 2022
  • This study, the method of reducing the exposure dose by changing the geometrical requirements among the preceding studies and the method of directly wearing a protector on the patient were used to expose the patient. A comparative experiment was conducted on the method of reducing the dose and the most effective method for reducing the exposure dose was investigated. Using the phantom, the dose of the lens, thyroid gland, and gonad gland in the 5 views most used in coronary angiography and intervention accumulated 5 times for 10 seconds at 60~70 kV, 200~250 mA as an automatic controller of the angiography system, and measured by Optically Stimulated Luminescent Dosimeter(OSLD). SID 100 cm and Cine 15 f/s as a control group the experiment was conducted by dividing the experimental group into 3 groups: a group lowered to Cine 7.5 f/s, a phantom protector, and a group lowered to 95 cm SID. As a result of the experiment, showing decrease in exposure dose compared to the control group. Lowering the cine frame may be the simplest and most effective method to reduce the exposure dose, but there is a limit that it cannot be applied if the operator judges that the diagnostic value is small or feels uncomfortable with the procedure. Conclusion as fallow reducing the exposure dose by directly wearing protector is the next best solution, and it is hoped that the conclusions obtained through this study will help reduce the exposure dose to unnecessary organ.

Polymerization of HEMA by Electron beam Irradiation and Fabrication of Soft contact lens (전자빔조사에 의한 HEMA의 중합과 소프트콘택트렌즈 제조)

  • Hwang, Kwang-Ha;Shin, Joong-Hyeok;Sung, Yu-Jin;Jeong, Keun-Seung;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • Purpose: Polymerization of HEMA(2-hydroxyethyl methacrylate) which can be used in the soft contact lens has been performed by using electron beam(EB) irradiation, and examined the best condition for the polymerization. Comparing the physical properties of the contact lenses to the one fabricated by thermal polymerization method, we check the use possibility of the EB irradiation to the fabrication of the soft contact lens. Methods: We investigated the degree of polymerization of the HEMA according to the composition of the monomer, the additive ratio and the dose of electron beam (0~120 kGy). The degree of polymerization was measured depending on the EB dose to research the best synthetic condition under the EB irradiation. The physical properties of the contact lens such as water content(%), oxygen transmissibility(Dk/t) and optical transmittance were analysed by using the FT-IR results with comparing the two different polymerization method (thermal and electron beam polymerization) with same additive ratio. Results: When the dose of electron beam was above 100 kGy, the degree of polymerization of HEMA was above 99% with regardless using cross-linker and initiator. The water content of the lens fabricated by EB method showed 10% higher than the one by the thermal method which was 40%. The lens fabricated by EB method also showed higher oxygen transmissibility(Dk/t) as same with the water content, and showed twice higher value in the lens fabricated by pure HEMA. According to the FT-IR results, hydrophilic property of the lens fabricated by EB method was increased due to increasing the intermolecular hydrogen bonding. It showed above 90% optical transmittance in the visible range of wavelength on the contact lenses fabricated by the both of two different polymerization method. Conclusions: The polymerization of HEMA without cross-linker and initiator was successful above 100 kGy of EB irradiation. Moreover the lens fabricated from the polymer synthesized by pure HEMA with 100 kGy of EB showed the highest water content and oxygen transmissibility. Therefore EB irradiation is another possible method to synthesize the polymer which can be used for the soft contact lens.

Comparison of Volumetric Modulated Arc Therapy and Non-coplanar Fixed-field Intensity Modulated Radiation Therapy for Irregular Target adjacent to Organ At Risk (손상위험장기에 인접한 불규칙한 모양의 타겟 치료 시, 용적변조회전 방사선치료와 비동일평면상의 빔을 이용한 세기변조 방사선치료의 유용성 평가 및 비교)

  • Kim, Kyung Ah;Na, Kyung Soo;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.57-68
    • /
    • 2017
  • Purpose: The purpose of this study was to compare volumetric modulated arc therapy(VMAT) with fixed-field intensity modulated radiation therapy(IMRT) using non-coplanar beam when the shape of target is irregular and the location is adjacent to organ at risk(OAR). Materials and Methods: The subjects of this study were a total of 6 patients who had radiation therapy for whole scalp(2 patients), partial scalp(2 patients), and whole ventricle(2 patients) by True Beam STX(Varian Medical Systems, USA). VMAT plans consisted of coplanar or non-coplanar arcs which can minimize the volume of OAR included in beamlets. All fixed-field IMRT plans consisted of non-coplanar beams using more than 2 angles of Couch. Results: The VMAT and IMRT plans were compared with regard to the maximum dose of both lens, both optic nerves, optic chiasm, and brain stem and the mean dose of both eyeballs and hippocampus. VMAT plans showed higher dose than ncIMRT plans at more than 6 of all OARs in every patient, and the ratio was from 1.1 times to 8.2 times. In case of total scalp and partial scalp, the volume of brain which received more than 20 Gy in the VMAT plans was 2 times larger than the volume in the ncIMRT plans. In case of whole ventricle, there was no significant difference. Target coverage was satisfied in both plans($PTV_{100%}=95%$). The maximum dose in target volume and required monitor unit(MU) of ncIMRT were higher than them of VMAT plans. Conclusion: Even though ncIMRT is less efficient than VMAT with regard to required MU and treatment time, the dose to OARs is much lower than VMAT and PTV Coverage is similar with VMAT. If the shape of target is irregular and location is adjacent to OAR, comparison VMAT plan with ncIMRT plan deserves to be considered.

  • PDF

Dose Distribution of 100 MeV Proton Beams in KOMAC by using Liquid Organic Scintillator (액체 섬광체를 이용한 100 MeV 양성자 빔의 선량 분포 평가)

  • Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.621-626
    • /
    • 2017
  • In this paper, an optical dosimetric system for radiation dose measurement is developed and characterized for 100 MeV proton beams in KOMAC(Korea Multi-Purpose Accelerator Complex). The system consists of 10 wt% Ultima GoldTM liquid organic scintillator in the ethanol, a camera lens(50 mm / f1.8), and a high sensitivity CMOS(complementary metal-oxide-semiconductor) camera (ASI120MM, ZWO Co.). The FOV(field of view) of the system is designed to be 150 mm at a distance of 2 m. This system showed sufficient linearity in the range of 1~40 Gy for the 100 MeV proton beams in KOMAC. We also successfully got the percentage depth dose and the isodose curves of the 100 MeV proton beams from the captured images. Because the solvent is not a human tissue equivalent material, we can not directly measure the absorbed dose of the human body. Through this study, we have established the optical dosimetric procedure and propose a new volume dose assessment method.

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF