• Title/Summary/Keyword: Length frequency data

Search Result 618, Processing Time 0.029 seconds

Estimation of Depth-Length Ratios with the Han-River Basin's Simultaneous Rainfall Data (한강유역 동시강우량 자료를 이용한 강우량-거리비의 산정)

  • 이원환;이길춘
    • Water for future
    • /
    • v.20 no.1
    • /
    • pp.55-61
    • /
    • 1987
  • This Study is to estimate depth-length ratios by the frequency analysis of simultaneous rainfall data on fixed points in the Han -River basin. The depth-length ratios are based on examination of spatial and temporal correlation structures of the Han-River basin's rainfall. This Study reveals that the depth-length ratios are decreasing as the distance of the basin increases and that they are increasing as the duration of rainfall increases. This study also shows that the ratios tend to decrease as the return period increase. The results present general equations and characteristic equations of depth-length ratios, figures and characteristic parameter tables which explain the temporal and spatial structures of rainfall in the Han-River basin.

  • PDF

The Improvement of Leakage Error in Digital courier Transform (디지털 푸리에 변환에서 누설오차의 개선)

  • 정의봉;안세진;장호엽;장진혁
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.455-460
    • /
    • 2001
  • An exact spectrum wish no leakage error could be obtained when the period of the signal coincides perfectly with the record length. However, the record length will be determined regardless of the period of signal. The Leakage error due to this problem will gibe a distorted spectrum. In the conventional research, the method was proposed to estimate the three parameters, frequency, amplitude and phase angle, from the spectrum data for anundamped sinusoidal signal. In this paper, some techniques are proposed to estimate frequency, amplitude and damping ratios from the frequency response functions for damped signals. The validation of the proposed techniques is verified by several numerical examples.

  • PDF

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

A study on improving the evaluation of motorway functions using Trip Length Frequency Distribution(TLFD) (통행거리빈도분포를 활용한 고속도로 기능 평가 개선 연구)

  • Kwon, Ceholwoo;Yoon, Byoungjo
    • Journal of Urban Science
    • /
    • v.11 no.2
    • /
    • pp.9-17
    • /
    • 2022
  • The purpose of this study is to develop an index for evaluating the function of a new motorway using the travel distance frequency distribution (TLFD) calculated using the vehicle travel route big data, and to overcome the limitations of the evaluation through the existing traffic volume. The mobility evaluation index of motorways was developed by applying it to the TLFD data table in 2019. The smaller the value of the mobility evaluation index of the link is calculated, the more it is a link with mainly short-distance travel, and the higher the value of the mobility evaluation index, the more it means a link with mainly long-distance travel. The accessibility evaluation index was calculated through the result of the mobility evaluation index of all motorways developed, and all motorways were grouped into three groups using K-means clustering. Group A was found to exist inside a large city and consisted of motorways with many short-distance traffic, Group B was investigated as acting as an arterial between groups, and Group C was classified as a motorway consisting mainly of long-distance traffic connecting large cities and large cities. This study is significant in developing a new motorway function evaluation index that can overcome the limitations of motorway function evaluation through the existing traffic volume. It is expected that this study can be a reasonable comprehensive indicator in the operation and planning process of motorways.

Determination of a New Cut-off Frequency Coefficient for Sound Propagation in the Surface Duct (표층도파관 내에서의 새로운 Cut-off 주파수 계수결정)

  • 김성부
    • The Journal of the Acoustical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.37-44
    • /
    • 1982
  • In the mixed layer when the frequency approaches the cut-off frequency for the first mode of notmalmode theory, sound ceases to be trapped. Based on the data of surface sound velocities abtained during the period of 16 years in the Sea of Japan. A new cut-off frequency coefficient in the surface duct that will determine the miximum wave length for duct transimission of underwater sound has been calculated.

  • PDF

Drying Characteristics of Large Western Redcedar Timber During Radio Frequency/Vacuum Drying (웨스턴 레드시더 큰 정각재(正角材)의 고주파 진공 건조 특성)

  • Jung, Hee-Suk;Avramidis, Stavros;Cai, Liping
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.1-8
    • /
    • 1998
  • Western redcedar timber, 26 by 26cm in cross section and by 200cm long, was dried in a laboratory radio-frequency/vacuum kiln under 65torr of ambient pressure and a fixed frequency of 6.78MHz for the potential rapidly dry large timber. All process data were collected and saved in a computer through a data acquisition system. The temperature in the middle of timber was higher than temperature at the quarter point of timber length and thickness. Temperature gradients developed in the longitudinal and transverse direction of timber. The pressure in the middle of timber was higher than pressure at the quarter point of timber length. The pressure in the middle of timber was lower in the early stage of drying, and higher in the latter stage of drying than pressure at the quarter point of timber thickness. Power density was very highest during heating period and then gradually decreased. The drying curve was approximately linear and the total drying time was 27 hours from an initial moisture content(MC) of 48.6 percent to a final Me of 19.2 percent with only a few mild internal checks in the middle location of timber.

  • PDF

Fundamental vibration frequency prediction of historical masonry bridges

  • Onat, Onur
    • Structural Engineering and Mechanics
    • /
    • v.69 no.2
    • /
    • pp.155-162
    • /
    • 2019
  • It is very common to find an empirical formulation in an earthquake design code to calculate fundamental vibration period of a structural system. Fundamental vibration period or frequency is a key parameter to provide adequate information pertinent to dynamic characteristics and performance assessment of a structure. This parameter enables to assess seismic demand of a structure. It is possible to find an empirical formulation related to reinforced concrete structures, masonry towers and slender masonry structures. Calculated natural vibration frequencies suggested by empirical formulation in the literatures has not suits in a high accuracy to the case of rest of the historical masonry bridges due to different construction techniques and wide variety of material properties. For the listed reasons, estimation of fundamental frequency gets harder. This paper aims to present an empirical formulation through Mean Square Error study to find ambient vibration frequency of historical masonry bridges by using a non-linear regression model. For this purpose, a series of data collected from literature especially focused on the finite element models of historical masonry bridges modelled in a full scale to get first global natural frequency, unit weight and elasticity modulus of used dominant material based on homogenization approach, length, height and width of the masonry bridge and main span length were considered to predict natural vibration frequency. An empirical formulation is proposed with 81% accuracy. Also, this study draw attention that this accuracy decreases to 35%, if the modulus of elasticity and unit weight are ignored.

Effects of a Constipation Intervention Program on Inpatients′ Defecation (변비 중재 프로그램이 입원환자의 배변에 미치는 효과)

  • 최자윤
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.1
    • /
    • pp.72-80
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the effect of a constipation reduction program for inpatients. Method: Subjects were selected in one medical ward of C University Hospital from May, 2001 to November, 2001. Twenty-nine subjects were assigned to an experimental group and 32 subjects to a control group. Data related to the frequency of defecation and to the length and amount of laxative drugs used was collected by a medical record review and data on the degree of constipation was obtained by a self-report using a constipation assessment scale. Results: More than 90% of the subjects admitted in the department of neurology and one third of total subjects presented with activity limitation and about one fourth of the subjects were fed with a nasogastric tube. There was a significant difference in the degree of constipation, frequency of defecation, and the length and amount of laxative drug use between the two groups. Conclusion: This program is effective in inpatient's constipation reduction. Further studies need to apply this program in various clinical environments and properly use this program in different clinical settings.

In situ side-aspect target strength of Japanese anchovy (Engraulis japonicus) in northwestern Pacific Ocean (북서 태평양 멸치(Japanese anchovy)에 대한 측면 음향 반사강도 특성)

  • Lee, Hyung-Been;Kang, Don-Hyug
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.3
    • /
    • pp.248-256
    • /
    • 2010
  • Acoustic side-aspect target strength (TS) of living Japanese anchovy (Engraulis japonicus) was measured at 120kHz during in situ experiments. The data were collected by lowering and horizontally projecting the splitbeam transducer into the anchovy school. For analysis and interpretation of the side-aspect TS data, acoustic theoretical model, based on the fish morphology, and dorsal-aspect TS data were used. Total length of the anchovy ranged from 6.6 to 12.8cm (mean length 9.3cm). The side-aspect TS distributed between -40 and -55dB, has an obvious length dependency. The mean side-aspect TS of the anchovy was -47.8dB, and the TS was about 2dB higher than mean TS generated from dorsal-aspect measurements. With reference to maximum TS, the results of the side-aspect TS were distributed within the range of the theoretical and dorsal-aspect TS. Apparently these tendency indicates that side-aspect TS measured from the study is useful data. These in situ measurements of side-aspect TS can be applied to improve acoustic detection and estimates of the anchovy, and is necessary to measure with a various frequency and length for making enhance data.

Inference of Age Compositions in a Sample of Fish from Fish Length Data (개체군 체장자료를 이용한 연령조성 추정)

  • Kim, Kyuhan;Hyun, Saang-Yoon;Seo, Young Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.51 no.1
    • /
    • pp.79-90
    • /
    • 2018
  • Fish ages are critical information in fish stock assessments because they are required for age-structure models such as virtual population analysis and stochastic catch-at-age models, whose outputs include recruitment strengths, a spawning stock size (abundance or biomass), and the projection of a fish population size in future. However, most countries other than the developed countries have not identified ages of fish caught by fisheries or surveys in a consistent manner for a long time (e.g.,>20 years). Instead, data about fish body sizes (e.g., lengths) have been well available because of ease of measurement. To infer age compositions of fish in a target group using fish length data, we intended to improve the length frequency analysis (LFA), which Schnute and Fournier had introduced in 1980. Our study was different in two ways from the Schnute and Fournier's method. First we calculated not only point estimates of age compositions but also the uncertainty in those estimates. Second, we modified LFA based on the von Bertalanffy growth model (vB-based model) to allow both individual-to-individual and cohort-to-cohort variability in estimates of parameters in the vB-based model. For illustration, we used data about lengths of Korean mackerel Scomber japonicas caught by purse-seine fisheries from 2000-2016.