• Title/Summary/Keyword: Length

Search Result 38,913, Processing Time 0.062 seconds

How to Avoid Graft-Tunnel Length Mismatch in Modified Transtibial Technique for Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Graft

  • Ko, Dukhwan;Kim, Hyeung-June;Oh, Seong-Hak;Kim, Byung-June;Kim, Sung-Jae
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.407-412
    • /
    • 2018
  • Background: We conducted this study to determine the optimal length of patellar and tibial bone blocks for the modified transtibial (TT) technique in anterior cruciate ligament (ACL) reconstruction using the bone-patellar tendon-bone (BPTB) graft. Methods: The current single-center, retrospective study was conducted in a total of 64 patients with an ACL tear who underwent surgery at our medical institution between March 2015 and February 2016. After harvesting the BPTB graft, we measured its length and that of the patellar tendon, patellar bone block, and tibial bone block using the arthroscopic ruler and double-checked measurements using a length gauge. Outcome measures included the length of tibial and femoral tunnels, inter-tunnel distance, length of the BPTB graft, patellar tendon, patellar bone block, and tibial bone block and graft-tunnel length mismatch. The total length of tunnels was defined as the sum of the length of the tibial tunnel, inter-tunnel distance and length of the femoral tunnel. Furthermore, the optimal length of the bone block was calculated as (the total length of tunnels - the length of the patellar tendon) / 2. We analyzed correlations of outcome measures with the height and body mass index of the patients. Results: There were 44 males (68.7%) and 20 females (31.3%) with a mean age of 31.8 years (range, 17 to 65 years). ACL reconstruction was performed on the left knee in 34 patients (53%) and on the right knee in 30 patients (47%). The optimal length of bone block was 21.7 mm (range, 19.5 to 23.5 mm). When the length of femoral tunnel was assumed as 25 mm and 30 mm, the optimal length of bone block was calculated as 19.6 mm (range, 17 to 21.5 mm) and 22.1 mm (range, 19.5 to 24 mm), respectively. On linear regression analysis, patients' height had a significant correlation with the length of tibial tunnel (p = 0.003), inter-tunnel distance (p = 0.014), and length of patellar tendon (p < 0.001). Conclusions: Our results indicate that it would be mandatory to determine the optimal length of tibial tunnel in the modified TT technique for ACL reconstruction using the BPTB graft. Further large-scale, multi-center studies are warranted to establish our results.

Association between Introduction of the Diagnosis-Related Groups System for Anal Operation and Length of Stay: Higher Effectiveness at Hospitals with Longer Length of Stay

  • Park, Hye Ki;Chun, Sung-Youn;Choi, Jae-Woo;Kim, Seung-Ju;Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.28 no.2
    • /
    • pp.178-185
    • /
    • 2018
  • Background: We investigated association between introduction of the diagnosis-related groups (DRG) system for anal operation and length of stay. Also, we investigated how it is different among hospitals with longer length of stay and among hospitals with shorter length of stay before introduction of the DRG system. Methods: We used data from Health Insurance Review and Assessment which were national health insurance claim data. Total 13,111 cases of anal surgery cases were included which were claimed by hospitals since July 2012 to June 2014. Two-level multivariable regression was conducted to analysis the association between length of stay and characteristics of hospital and patient. Results: Before introducing DRGs, the average length of stay was 5.41 days. After introducing DRGs, average length of stay was decreased to 3.92 days. After introducing DRGs, length of stay has decreased (${\beta}=-1.0450$, p<0.0001) and it was statistically significant. Among hospitals which had short length of stay (shorter than mean of length of stay) before introducing DRGs, effect of introducing DRGs was smaller (${\beta}=-0.4282$, p<0.0001). On contrary, among hospitals which had long length of stay (longer than mean of length of stay) before introducing DRGs, effect of introducing DRGs was bigger (${\beta}=-1.8280$, p<0.0001). Conclusion: Introducing DRGs was more effective to hospitals which had long length of stay before introducing DRGs.

Control of Shrinkage Cracking of Cement Composites with Different Length Mixture of PVA Fibers (서로 다른 길이의 PVA 섬유 혼합에 따른 시멘트 복합체의 균열제어 특성)

  • Won, Jong-Pil;Kim, Myung-Kyun;Park, Chan-Gi;Kim, Wan-Young;Park, Kyoung-Hoon;Jang, Chang-Il
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.405-408
    • /
    • 2006
  • The purpose of this study was to determine the optimum length distribution of hybrid PVA(Poly vinyl alcohol) fiber. To produce blended PVA fiber length, first the length distribution of PVA fiber in the cement composites were identified in an experimental study based on simplex lattice design. Among the different length distributions investigated, fiber length was found to have statistically significant effect on plastic shrinkage cracking of cement composites. Subsequently, Complex analysis techniques were used to devise an experimental program that helped determine the optimum combinations of the selected fiber length distribution based on plastic shrinkage crack. The optimum blended PVA length ratio was 0.0146% 4mm fiber, 0.0060% 6-mm fiber, 0.0285% 8-mm fiber, and 0.0209% 12-mm fiber.

  • PDF

Estimation of production length of PC beam by using splice length of bottom rebar (하부철근 이음길이에 따른 PC 보 제작 길이 산정)

  • Sung, Soojin;Lim, Chaeyeon;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.84-85
    • /
    • 2014
  • Green frame is column-beam structure composed of precast concrete members. Based on Revision of Structural Concrete Design Code, the bottom rebar of beam shall be extend at least 150mm into the support member. However, if the bottom rebar extend to satisfy Revision of Structural Concrete Design Code, the installation fo beam is impossible due to interference between the columns and beams. Thus, the aim of this study is estimation of production length of precast concrete beam by using splice length of bottom rebar. In this study to solve this problem, lap splice were used on the join. This study was calculated length of the reinforcement by the diameter. According to the length of the rebar, the production length of beam concrete was calculated. The results of this study will satisfy the Revision of Structural Concrete Design Code about column-beam connection when green frame will be applied.

  • PDF

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

Derivation of Development Length in Pretensioned Prestressed Concrete Members (프리텐션공법의 프리스트레스트 콘크리트 부재의 정착길이 산정에 관한 실험 및 이론연구)

  • 오병환;김의성;최영철
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.3-11
    • /
    • 2000
  • In pretensioned concrete structures, bond between prestressing steel and concrete is an essential component to ensure the integrity of a pretensioned member. The anchorage and development of the prestressing force depend exclusively on bond. The purpose of this study is to investigate the characteristics of bond and development length between pretensioned steel and concrete. To resolve the controversy over the adequacy of the current code provision on development length of prestressing strands, a comprehensive test program has been scheduled and twenty four rectangular prestressed concrete beams have been tested to determine development length. Major test variables include diameter of strands (12.7mm, 15.2mm) and concrete covers (3cm, 4cm, 5cm). The test results indicate that the development length based on the bond stress-slip relation. The proposed model can evaluate realistically the development length of pretensioned prestressed concrete members and can be the good basis for the future basis of code equations on development length of PSC members.

Clinical Evaluation and Treatment of Leg Length Inequality (하지길이균차에 대환 임상평가와 치료)

  • Kim, Chang-Hwan;Kim, Jong-Deog
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.5 no.1
    • /
    • pp.19-29
    • /
    • 2004
  • Objectives : Visual check and X-ray are commonly used by chiropractors to estimate ieg length inequality, This study have three categories: diagnosis for anatomic leg length inequality; difference between anatomic and functional leg length inequality; theraphies for anatomic or functional leg length inequality. Methods : We referred to a PubMed site by using word of 'leg length [JU] J Manipulative Physiol Ther', only items with abstracts. Results : We searched 26 articles in J Manipulative Physiol Ther with the key word-Ieg length. Conclusion : 1. Radiographs were most accurate and commonly used by chiropractors to measure anatomic leg length inequality, clinically wood block, tape measure, visual check are acceptable. 2. There was no article about difference between anatomic and functional leg length inequality. 3. Heel lift was commonly used with conservative theraphy for anatomic leg length Inequality. 4. Chiropractors have not yet proved that the supposed positive effects are a result of a reduction of subluxation, The detection of the manipulative lesion in the sacroiliac joint depends on valid and reliable tests, Because such tests have not been established, the presence of the manipulative lesion remains hypothetical. Great effort is needed to develop, establish and enforce valid and reliable test procedures.

  • PDF

Structural analysis of joint part by adhesive length of a composite pressure vessel with separated dome (돔 분리형 연소관의 접착 길이에 따른 체결부의 구조해석)

  • Jeon, Kwang-Woo;Shin, Kwang-Bok;Hwang, Tea-Kyung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.933-937
    • /
    • 2011
  • In order to determine optimal design length of adhesive joint of a composite pressure vessel with separated dome, stress analysis of joint part according to changes of adhesive length was done. Adhesive length has a range of 50mm to 300mm as design variables. The ratio of adhesive length with any stress gradient to initial non-stressed adhesive length was called "stress gradient length ratio" and selected as objective function. The stress gradient length ratio of joint part with adhesive length of more than 200mm was increased very slowly with increase of adhesive length. It means that adhesive length of about 200mm could be the optimal value to ensure the structural safety of joint part against internal pressure of 2,500 psi.

  • PDF

Analysis of the effects of the baseline length accuracy in integer ambiguity resolution for GPS attitude determination system

  • Lee, Geon-Woo;Son, Seok-Bo;Park, Chan-Sik;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1211-1215
    • /
    • 2005
  • In the GPS attitude determination system, the baseline length constraints can be used efficiently to reduce the search space. It is possible by adopting the assumptions that the baseline length doesn't change and the true baseline length is precisely known. But in real situation, the baseline length might be changed by many reasons and it is impossible to measure the true baseline length because there exists measurement error and antenna phase centre movement. In order to analyze the effect of the baseline length accuracy, one needs to know the relation between the accuracy of the baseline length and success rates of the integer ambiguity resolution. In this paper, the effect of the baseline length accuracy to the integer ambiguity resolution in the attitude determination system is analyzed by empirical method. The results show that the margins in the baseline length accuracy is less than a few cm which implies that one should take great cares when applying the attitude determination system to the flexible structures.

  • PDF

Diallel Cross Analysis of Characters in Barley (이면교잡에 의한 대맥형질의 유전분석)

  • Chung, Won-Bok;Chung, Dae-Soo;Takeda, Kazuyoshi;Sato, Kazuhiro
    • Journal of Life Science
    • /
    • v.7 no.1
    • /
    • pp.59-65
    • /
    • 1997
  • In this experiment, gene actions were analysized for seven barley parents in order to obtain basic information on their genetic improvement by diallel crosses. The results obtained were summarized as follows. In analysis of variance, additive, dominant, maternal and reciprocal effects were observed significantly for culm length, tiller number, number of spiked per plant, culm diameter, awn length, leaf width, number of grains per spike, and 1000 grain weight. Over-dominance was shown by Vr-Wr graphic analysis in five characters such as tiller number, number of spikes per plant, length of flag leaf, number of grains per spike, and 1000 grain weight, and partial dominance in four characters such as culm length, culm diameter, awn length, and leaf width. Component of genetic varience analyzed for four characters such as culm diameter, awn length, length of flag leaf, and leaf width showed that additive effects were higher than dominant effects. Culm length, tiller number, number of spikes per plant, number of grains per spike, and 1000 grain weight showed dominant effects higher than additive effects. The narrow-sense heritability for awn length, leaf width, and number of grains per spike showed high values as more than 0.62, while broad-sense heritability for culm length, number of spikes per plant, culm diameter, awn length, leaf width, number of grains per spike, and 1000 grain weight showed high values as more than 0.65.

  • PDF