• Title/Summary/Keyword: Leg Length Difference

Search Result 103, Processing Time 0.088 seconds

Effect of Various Lower Extremity Exercises Using the Swiss Ball While Standing on Balance, Muscle Strength, Gait and Fall Efficacy in Stroke Patients: A Pilot Study

  • Lim, Yun-Jeong;Kang, Soon-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.4
    • /
    • pp.202-209
    • /
    • 2021
  • Purpose: This study examined whether various lower extremity exercises using a Swiss ball in the standing position could improve balance, muscle strength, gait, and fall efficacy in stroke patients. Methods: Twenty-one stroke patients were randomly divided into three groups, each with seven participants. For four weeks, experimental group 1 performed various lower extremity exercises using a Swiss ball, while experimental group 2 executed the same exercises without a Swiss ball, and the control group underwent general physical therapy. The subjects' knee extensor muscle strength, balance, gait, and fall efficacy were evaluated before and after the intervention using portable muscle strength measurement, the Berg Balance Scale (BBS), G-walk, and the Korean Falls Efficacy Scale (K-FES). Results: Knee extensor strength increased significantly in all three groups after the intervention; in particular, a significant increase was seen in experimental groups 1 and 2 compared to the control group. Moreover, all three groups had significantly better BBS scores and higher cadence after the intervention; notably, experimental group 1 had better scores and increased cadence than the control group. Additionally, gait speed was significantly increased in the experimental group 1 than in the control group. The step length of the non-affected leg was also significantly higher in the same group. The K-FES score improved significantly in all three groups, but there was no significant difference between the groups. Conclusion: This study suggests that lower extremity exercises with or without a Swiss ball could be effective interventions to improve muscle strength, balance, gait, and fall efficacy in stroke patients.

Effects of the Patellar Tendon Strap on Kinematics, Kinetic Data and Muscle Activity During Gait in Patients With Chronic Knee Osteoarthritis

  • Eun-Ji Lee;Ki-Song Kim;Young-In Hwang
    • Physical Therapy Korea
    • /
    • v.30 no.2
    • /
    • pp.110-119
    • /
    • 2023
  • Background: Osteoarthritis is a common condition with an increasing prevalence and is a common cause of disability. Osteoarthritic pain decreases the quality of life, and simple gait training is used to alleviate it. Knee osteoarthritis limits joint motion in the sagittal and lateral directions. Although many recent studies have activated orthotic research to increase knee joint stabilization, no study has used patellar tendon straps to treat knee osteoarthritis. Objects: This study aimed to determine the effects of patellar tendon straps on kinematic, mechanical, and electromyographic activation in patients with knee osteoarthritis. Methods: Patients with knee osteoarthritis were selected. After creating the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), leg length difference, Q-angle, and thumb side flexion angle of the foot were measured. Kinematic, kinetic, and muscle activation data during walking before and after wearing the orthosis were viewed. Results: After wearing the patellar tendon straps, hip adduction from the terminal stance phase, knee flexion from the terminal swing phase, and ankle plantar flexion angle increased during the pre-swing and initial swing phases. The cadence of spatiotemporal parameters and velocity increased, and step time, stride time, and foot force duration decreased. Conclusion: Based on the results of this study, the increase in plantar flexion after strap wearing is inferred by an increase due to neurological mechanisms, and adduction at the hip joint is inferred by an increase in adduction due to increased velocity. The increase in cadence and velocity and the decrease in gait speed and foot pressure duration may be due to joint stabilization. It can be inferred that joint stabilization is increased by wearing knee straps. Thus, wearing a patellar tendon strap during gait in patients with knee osteoarthritis influences kinematic changes in the sagittal plane of the joint.

Effects of visual information on Y-Balance Test (시각정보가 Y-Balance Test에 미치는 영향)

  • Byung-Hoon Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.977-987
    • /
    • 2023
  • The purpose of this study was to investigate the effect of visual information on the dynamic balance on Y-balance Test(YBT). The subjects of the study were 18 male and female adults in their 20s and 30s (age: 23.17±1.72 years, height: 172.46±9.84 cm, weight: 73.39±11.44 kg, leg length: 88.89±5.69 cm) who participated in the study. To measure dynamic balance between binocular and monocular use, absolute reach distance, composite score, and COP variables were measured on left and right feet through YBT and results were derived. As a result of the study, monocular block(left and right eye block) showed higher absolute reach and composite scores than binocular use in posterolateral, posteromedial, and composite scores during YBT. As a result of COP, there was no difference in anterior and posteromedial reach. When reaching posterolateral, AP COP velocity of left foot in monocular block appeared slower than that in binocular vision, and in COP velocity, COP velocity of left foot in monocular block appeared slower than binocular vision.

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

The Effect of Habitat Size on Huanren Brown Frog (Rana huanrensis) Larvae's Growth Rate in Mt. Surak (수락산에 서식하는 계곡산개구리(Rana huanrensis Fei, Ye & Huang, 1991) 유생의 서식지 면적에 따른 생장률 연구)

  • Na, Sumi;Um, Yewon;Kim, Hyun-jung;An, Chi-Kyung;Yi, Hoonbok
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.2
    • /
    • pp.75-82
    • /
    • 2017
  • This study was executed to know the effect of the habitat size on huanren brown frog (Rana huanrensis) larvae's growth. We've conducted the study on Mt. Surak in Sanggye-dong, Nowon-gu, Seoul. Our study site was discriminated the huanren brown frog larvae's habitat into the three different areas, such as small area (S1, $3.91m^2$), middle area (S2, $4.42m^2$), and large area (S3, $38.37m^2$) in the same water channel. We measured two times per a week the 15 huanren brown frog larvae's body length, and developmental stages (foreleg, hind leg, tail length) including the environmental factors (humidity, air temperature and water temperature) of the study site from March 30 to June 28 in 2016. The only hatching rate was measured for the three egg sacs at the S2 study site. We found that the average hatching rate was $76.84{\pm}18.23(%)$ at S2. Generally, because of less precipitation during our study periods, all habitat areas for our study site were gradually decreased. The middle area, S2, was not reduced, the small area, S1, was reduced more than a fourth, and the largest area, S3, was drastically reduced more than half from initial area. There was no statistically difference among the three study sites for the three environmental factors (average humidity, average air temperature, and average water temperature) by F-test, but there were significant difference among the three site for the larvae's body length (F-test p< 0.05). Therefore, the larger of habitat areas, the larger of the larvae length as well as the faster of the larvae's developmental stages. When we measured the body lengths of immature huanren brown frogs, the immature frog of S1 was smallest, the immature frog of S3 was middle lenght, and the immature frog of S2 was largest. There were statistically different among the three study sites for the immature huanren brown frogs (F-test, p< 0.05). Because the S2 study site was relatively stable without rarely changing the study area, it meant that huanren brown frog was sensitive to habitat areas. Based on the results of this study, if we study on the effect of the altitude on the growth rate of huanren brown frog, it must be helpful in understanding the habitat environment of the population of huanren brown frog.

Kinematic Effects of Newly Designed Knee-Ankle-Foot Orthosis With Oil Damper Unit on Gait in People With Hemiparesis

  • Park, Hyung-Ki;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.64-73
    • /
    • 2013
  • The purposes of this study were to develop a new orthosis controlling ankle and knee joint motion during the gait cycle and to identify the effects of the newly designed orthosis on gait kinematics and tempospatial parameters, including coordination of the extremities in stroke patients. Fifteen individuals who had sustained a stroke, onset was 16 months, participated in this study. Before application of the measurement equipment the subjects were accustomed to walking on the ankle-foot orthosis (AFO) or stance control knee with knee flexion assisted-oil damper ankle-foot orthosis (SCKAFO) for 5 minutes. Fifteen patients were investigated for 45 days with a 3-day interval between sessions. Measurements were walking in fifteen stroke with hemiparesis on the 3D motion analysis system. Comparison of AFO and SCKAFO are gait pattern. The difference between the AFO and SCKAFO conditions was significant in the gait velocity, step length of the right affected side, stance time of both legs, step-length asymmetry ratio, single-support-time asymmetry ratio, ${\phi}$-thigh angle and ${\phi}$-shank angle in the mid swing (p<.001). Using a SCKAFO in stroke patients has shown similar to normal walking speeds can be attained for walking efficiency and is therefore desirable. In this study, the support time of the affected leg with the SCKAFO was longer than with the AFO and the asymmetry ratio of single support time decreased by more than with the AFO. This indicates that the SCKAFO was effective for improving gait symmetry, single-support-time symmetry. This may be due to the decrease of gait asymmetry. Thus, the newly designed SCKAFO may be useful for promoting gait performance by improving the coordination of the extremity and decreasing gait asymmetry in chronic stroke patients.

Effect of Different Stunning Time on Meat Quality of Broiler (육계 도축 시 전기 실신 시간이 육질에 미치는 영향)

  • Chae, H.S.;Ahn, C.N.;Yoo, Y.M.;Ham, J.S.;Jeong, S.G.;Lee, J.M.;Choi, Y.I.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.1017-1024
    • /
    • 2005
  • This study was investigated the effect of the length of stunning time on pH, water holding capacity(WHC), cooking loss(CL), meat color and incidence rate of blood spot in broiler carcass. One-hundred and forty broiler chickens were slaughtered by three different length of stunning times(5 sec., 8 sec., 11 sec.) with the same electrical frequency(255Hz) and 50 voltage in a commercial abattoir. The WBS values and cooking loss of breast muscle were increased with increasing the stunning time, while WHC of breast muscle were decreased. Lightness(L* value) and yellowness(b* value) scores of leg muscle and skin stunned with 50V, 255Hz, 8 sec, 11 sec. were higher than those of broilers stunned with 50V, 255Hz, 5sec(P<0.05). But, there was no significant difference in color on breast and wing muscle. In subjective evaluation, frequence of the first grade had a trend of being increased by extending the stunning time. There was only a few cases of PSE chicken with 0.02%, while blood spot was observed at the highest rate for the 5 sec. treatment. TBARS indicated that a longer length of stunning resulted in a higher rate of fat oxidation. This experiment demonstrated that the length of stunning time has a significant effect on meat quality and its stability during chiller storage.

Association between muscular strengths and gait characteristics of elderly people aged 65 to 74 and 75 and above (전·후기 노인의 근력과 보행 특성의 관계)

  • Back, Chang-Yei;Joo, Ji-Yong;Kim, Young-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.415-422
    • /
    • 2020
  • This study investigates the relationship between muscular strengths and gait characteristics of the elderly. Totally, 107 subjects, aged 65 to 85 years, participated in this study. Researchers measured muscle strengths (grip force, toe grip force, gluteus medius, and gluteus maximus forces) and walking characteristics (walking speed, cadence, step length, single leg support, and double legs support). Dynamometers and inertial measurement unit-based shoe systems were used for measuring muscular strength and gait characteristics, respectively. No significant difference was observed in strengths and walking characteristics between the young elders (YE, 65-74 years) and the old elders (OE, 75-85 years). For each age, muscular strength significantly correlated with some gait parameters. Forces of gluteus medius and gluteus maximus muscles showed better significant correlations between some gait parameters for all age groups, as compared to grip force and toe grip force. Regression coefficients between walking speed and grip force did not vary with age. We conclude that muscular strengths in OE better explained the gait characteristics than in YE subjects. Even though grip strength is an easily measured variable for senior fitness test, forces of gluteus medius and gluteus maximus muscles are more meaningful for understanding the walking characteristics of elderly people.

Clinical Analysis of Pelvic Fracture in 54 Dogs (54두 개에서 발생한 골반 골절의 임상적 분석)

  • Kim, Kyung-Hee;Lee, Jong-Hoon;Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.467-472
    • /
    • 2011
  • This study was conducted to describe clinical presentation of pelvic fracture and compare clinical outcomes of each part of pelvic fractures in 54 client-owned dogs. There was an average of 3.61 pelvic fractures per dog and 47 dogs had more than two fractures. The average time until initial weight-bearing on the affected leg, hospitalization after surgery, and lameness score at final check in 31 dogs that underwent surgery were 7.04 days, 16.39 days, and 1.25, respectively, and there were no significant difference in the incidence of sacroiliac luxation, iliac fracture, and acetabular fracture among them. The length of hospitalization and the lameness score upon final check of the dogs with over two surgically repaired sites were significantly longer and higher than those of the dogs with one surgically repaired site (P = .043 and P = .008, respectively). Upon final check of the dogs with bilateral pelvic fracture that was surgically treated, the hospitalization and lameness score were significantly longer and higher than those of dogs with unilateral pelvic fracture that was surgically treated (P = .034 and P = .033), respectively. The number of pelvic fractures treated surgically appears to be a more influential factor influencing recovery from pelvic fractures than the location of the pelvic fractures.

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF