• Title/Summary/Keyword: Left ventricular functional parameters

Search Result 21, Processing Time 0.024 seconds

Cardioprotective Effect by Preconditioning with Calcium-free Solution (칼슘결핍용액 투여 전처치에 의한 심근보호 효과)

  • 조대윤;이종화;김호덕
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.773-780
    • /
    • 1999
  • Background: It has been demonstrated that brief periods of calcium depletion and repletion (calcium-free preconditioning, CP) have cardioprotective effects as seen in ischemic preconditioning(IP) which enhances the recovery of post-ischemic contractile dysfunction and reduces the incidence of reperfusion-induced arrhythmia or infarct size after a prolonged ischemia. In the present study, we tested this paradoxical phenomenon in isolated rabbit hearts. Material and Method: Hearts isolated from New Zealand white rabbits(1.5∼2.0 Kg body weight) were perfused with Tyrode solution using the Langendorff technique. After stabilizing the baseline hemodynamics, the hearts were subjected to 45 minutes of global ischemia followed by 120 minutes of reperfusion with IP(IP group, n=7) or without IP (ischemic control group, n=7). IP was induced by a single episode of 5 minutes global ischemia and 10 minutes reperfusion. In the CP group(n=7), the hearts were subjected to perfusion with Tyrode solution with calcium depletion for 5 minutes and repletion for 10 minutes, and 45 minutes of ischemia and 120 minutes of reperfusion. Left ventricular function including developed pressure, dP/dt, heart rate, left ventricular end-diastolic pressure and coronary flow was measured. Infarct size was determined by staining with 1% triphenyltetrazolium chloride and planimetry. Data were analyzed by a one-way analysis of variance and Tukey's post-hoc test. Result: In comparison with the ischemic control group, IP significantly enhanced the recovery of the left ventricular function including the left ventricular developed pressure, contractility, and coronary flow; in contrast, these functional parameters of the CP group tended to be lower than those of the ischemic control group. However, the infarct size was significantly reduced by IP or CP(p<0.05). Conclusion: These results suggest that in isolated Langendorff-perfused rabbit heart model, CP(induced by single episode of 5 minutes calcium depletion and 10 minutes repletion) could not improve the post-ischemic contractile dysfunction(after a 45-minute global ischemia) but it has an infarct size-limiting effect.

  • PDF

Beneficial effects of andrographolide in a rat model of autoimmune myocarditis and its effects on PI3K/Akt pathway

  • Zhang, Qi;Hu, Li-qun;Li, Hong-qi;Wu, Jun;Bian, Na-na;Yan, Guang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.23 no.2
    • /
    • pp.103-111
    • /
    • 2019
  • The study is to investigate effects of andrographolide on experimental autoimmune myocarditis (EAM). Lewis rats were immunized on day 0 with porcine cardiac myosin to establish EAM. The EAM rats were treated with either andrographolide (25, 50, 100 mg/kg/day) or vehicle for 21 days. An antigen-specific splenocytes proliferation assay was performed by using the cells from control rats immunized with cardiac myosin. Survival rates, myocardial pathology and myocardial functional parameters (left ventricle end-diastolic pressure, ${\pm}dP/dt$ and left ventricular internal dimension) of EAM rats received andrographolide were significantly improved. Andrographolide treatment caused an decrease in the infiltration of $CD3^+$ and $CD14^+$ positive cells in myocardial tissue. Moreover, andrographolide treatment caused a reduction in the plasma levels of tumor necrosis factor-alpha, interleukin-17 (IL-17) and myosin-antibody, and an increase in the level of IL-10 in EAM rats. Oral administration of andrographolide resulted in the decreased expression of p-PI3K, p-Akt without any change of PI3K and Akt. Further results indicate andrographolide significantly inhibited myosin-induced proliferation in splenocytes, and this effect was inhibited by co-treatment of SC79 (Akt activator). Our data indicate andrographolide inhibits development of EAM, and this beneficial effect may be due to powerful anti-inflammatory activity and inhibitory effect on PI3K/Akt pathway.

Thyroid Hormone-Induced Alterations of $Ca^{2+}-ATPase$ and Phospholamban Protein Expression in Cardiac Sarcoplasmic Reticulum

  • Kim, Hae-Won;Noh, Kyung-Min;Park, Mi-Young;Lee, Hee-Ran;Lee, Eun-Hee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.2
    • /
    • pp.223-230
    • /
    • 1999
  • Alterations of cardiovascular function associated with various thyroid states have been studied. In hyperthyroidism left ventricular contractility and relaxation velocity were increased, whereas these parameters were decreased in hypothyroidism. The mechanisms for these changes have been suggested to include alterations in the expression and/or activity levels of various proteins; ${\alpha}-myosin$ heavy chain, ${\beta}-myosin$ heavy chain, ${\beta}-receptors,$ the guanine nucleotide-binding regulatory protein, and the sarcolemmal $Ca^{2+}-ATPase.$ All these cellular alterations may be associated with changes in the intracellular $Ca^{2+}$ concentration. The most important regulator of intracellular $Ca^{2+}$ concentration is the sarcoplasmic reticulum (SR), which serves as a $Ca^{2+}$ sink during relaxation and as a $Ca^{2+}$ source during contraction. The $Ca^{2+}-ATPase$ and phospholamban are the most important proteins in the SR membrane for muscle relaxation. The dephosphorylated phospholamban inhibits the SR $Ca^{2+}-ATPase$ through a direct interaction, and phosphorylation of phospholamban relieves the inhibition. In the present study, quantitative changes of $Ca^{2+}-ATPase$ and phospholamban expression and the functional consequences of these changes in various thyroid states were investigated. The effects of thyroid hormones on (1) SR $Ca^{2+}$ uptake, (2) phosphorylation levels of phospholamban, (3) SR $Ca^{2+}-ATPase$ and phospholamban protein levels, (4) phospholamban mRNA levels were examined. Our findings indicate that hyperthyroidism is associated with increases in $Ca^{2+}-ATPase$ and decreases in phospholamban levels whereas opposite changes in these proteins occur in hypothyroidism.

  • PDF

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

Are Biomarkers Predictive of Anthracycline-Induced Cardiac Dysfunction?

  • Malik, Abhidha;Jeyaraj, Pamela Alice;Calton, Rajneesh;Uppal, Bharti;Negi, Preety;Shankar, Abhishek;Patil, Jaineet;Mahajan, Manmohan Kishan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2301-2305
    • /
    • 2016
  • Background: The early detection of anthracycline- induced cardiotoxicity is very important since it might be useful in prevention of cardiac decompensation. This study was designed with the intent of assessing the usefulness of cardiac troponin T (cTnT) and NT- Pro BNP estimation in early prediction of anthracycline induced cardiotoxicity. Materials and Methods: In this prospective study histologically proven breast cancer patients who were scheduled to receive anthracycline containing combination chemotherapy as a part of multimodality treatment were enrolled. Baseline cardiac evaluation was performed by echocardiography (ECHO) and biomarkers like cardiac troponin T (cTnT) and N terminal- pro brain natriuretic peptide (NT- Pro BNP). All patients underwent cTnT and NT- Pro BNP estimation within 24 hours of each cycle of chemotherapy and were followed up after 6 months of initiation of chemotherapy. Any changes in follow up ECHO were compared to ECHO at baseline and cTnT and NT- Pro BNP levels after each cycle of anthracycline-based chemotherapy. Results: Initial data were obtained for 33 patients. Mean change in left ventricular diastolic diameter (LVDD) within 6 months was $0.154{\pm}0.433cms$ (p value=0.049). Seven out of 33 patients had an increase in biomarker cTnT levels (p value=0.5). A significant change in baseline and follow up LVDD was observed in patients with raised cTnT levels (p value=0.026) whereas no change was seen in ejection fraction (EF) and left atrial diameters (LAD) within 6 months of chemotherapy. NT- Pro BNP levels increased in significant number of patients (p value ${\leq}0.0001$) but no statistically significant change was observed in the ECHO parameters within 6 months. Conclusions: Functional monitoring is a poorly effective method in early estimation of anthracycline induced cardiac dysfunction. Estimation of biomarkers after chemotherapy may allow stratification of patients in various risk groups, thereby opening window for interventional strategies in order to prevent permanent damage to the myocardium.

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.

Reference Values of Functional Parameters in Gated Myocardial Perfusion SPECT : Comparison with $QGS^{\circledR}$ and $4DM^{\circledR}$ Program (게이트 심근 관류 스펙트의 심기능 지표의 정상 참고값 : $QGS^{\circledR}$ 프로그램과 $4DM^{\circledR}$ 프로그램의 비교)

  • Jeong, Young-Jin;Park, Tae-Ho;Cha, Kwang-Soo;Kim, Moo-Hyun;Kim, Young-Dae;Kang, Do-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.430-437
    • /
    • 2005
  • Purpose: The objectives of this study were - First, to determine the normal range of left ventricular end diastolic volume (EDV), end systolic volume (ESV) and election fraction (EF) from gated myocardial perfusion SPECT for Quantitative Gated SPECT (QGS) and 4D-MSPECT (4DM), respectively. Second, to evaluate the relationships between values produced by both software packages. Materials & Methods: Tc-99m MIBI gated myocardial perfusion SPECT were performed for 77 patients (mean age: $49.6{\pm}13.7y$, n=37(M), 40(F)) with a low likelihood (<10%) of coronary artery disease (CAD) using dual head gamma camera (E.CAM, Siemens, USA). Left ventricular EDV, ESV and EF were automatically measured by means of QGS and 4DM, respectively. Results: in QGS, the mean EDV, ESV and EF for all patients were $78.2{\pm}25.2ml,\;27.4{\pm}12.9ml\;and\;66.6{\pm}8.0%$ at stress test respectively, not different from rest test (p>0.05). In 4DM, the mean EDV, ESV and EF for all patients were $89.1{\pm}26.4ml,\;29.1{\pm}12.8ml\;and\;68.5{\pm}6.7%$ at stress test. Most cases in 4DM, there was no significant difference statistically between stress and rest test (p>0.05). But statistically significant difference was found in EF ($68.5{\pm}6.7%$ at stress vs $70.9{\pm}8.0%$ at rest, p<0.05). Correlation coefficients between the methods for EDV, ESV and EF were comparatively high (0.95, 0.93, 0.71 at stress test and 0.95, 0.90, 0.69 at rest test, respectively). However, Bland-Altman plots showed a large range of the limit value of agreement for EDV, ESV and EF between both methods ($-30ml{\sim}10ml,\;-12ml{\sim}8ml,\;-14%{\sim}11%$ at stress test and $-32ml{\sim}5ml,\;-13ml{\sim}13ml,\;-18%{\sim}12%$ at rest test). Conclusion: We found the normal ranges of EDV, ESV and EF for patients with a low likelihood of CAD in both methods. We expect these values will be a good reference to interpret gated myocardial perfusion SPECT. Although good correlation was observed between both methods, they should not be used interchangeably. Therefore, when both programs are used at the same site, it will be important to apply normal limits specific to each method.

Efficacy of Mitral Valve Surgery in Moderate Ischemic Mitral Regurgitation (MR) (중등도의 허혈성 승모판막 폐쇄부전증 환자에서 승모판막 수술의 유용성)

  • Jung Sung Ho;Lee Jae Won;Choi Jun Young
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.357-365
    • /
    • 2005
  • Background: Patients with mitral regurgitation (MR) in the setting of coronary artery disease have a dismal long-term prognosis whether treated medically or surgically. Moreover, the optimal management of moderate ischemic MR at the time of coronary artery bypass grafting (CABG) remains the subjects of controversy. Thus, the present retrospective study was undertaken to determine whether mitral valve surgery for moderate ischemic MR at the time of CABG would be preferable to CABG alone in terms of clinical outcome. Material and Method: Between January 1997 and December 2003, 34 patients with moderate (Gr 3/4) ischemic MR underwent CABG alone (Group I, n=23) or CABG plus mitral valve surgery (Group II, n=11). Operative mortality, long-term survival and echocardiographic parameters were used to evaluate the efficacy of mitral valve surgery in patients with moderate ischemic MR. The mean follow-up durations of each group were $69.3\pm4.3$ months and $53.1\pm4.9$ months respectively. Result: There was no hospital mortality in both groups. There was one case of late mortality in Group I. The mean number of bypass graft was similar ($3.8\pm1.2\;vs\;3.7\pm1.3$ respectively). Cardiopulmonary bypass time was longer in group II (p=0.014). In group II, all of the patients received mitral annuloplasty using ring. On immediate postoperative echo-cardiogram, mitral regurgitation was reduced more in group II (p=0.002). Echocardiogram performed at last follow-up state showed no difference except the grade of MR between the two groups. Actuarial survival of both groups at 5 years was similar ($95.5\%\;vs\;100\%$, p=0.48). Conclusion: This study shows that in selected patients with moderate ischemic MR, CABG without mitral valve surgery might be sufficient. However, patients with low EF and NYHA functional class pre-operatively had tendency of significant residual MR, so mitral valve surgery should be necessary in these patients, and moreover, MR severity and left ventricle volume decreased more in mitral valve surgery group. Therefore, more large-scale studies are necessary to determine these effects on the ventricular function and long-term survival.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF