• 제목/요약/키워드: Left to right ratio

검색결과 589건 처리시간 0.028초

초급성 허혈성 뇌졸중 환자에서 관류자기공명영상의 정량적 평가: 1.5 T와 3.0 T 기기 비교 (Quantitative Evaluation of Perfusion Magnetic Resonance Imaging in Hyper-acute Ischemic Stroke Patients: Comparison with 1.5 T and 3.0 T Units)

  • 구은회;문일봉;동경래
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.193-198
    • /
    • 2016
  • Perfusion magnetic resonance image of biological mechanism are independent of magnetic field strength in hyper acute ischemic stroke. 3.0 T magnetic field, however, does affect the SNRs (signal to noise ratio) and artifacts of PMRI (perfusion magnetic resonance image), which basically will influence the quantitative of PMRI. In this study, the effects of field strength on PMRI are analyzed. The effects of the diseases also are discussed. PMRI in WM(white matter), GM (gray matter), hyper acute ischemic stroke were companied with 1.5 T and 3.0 T on SNR. PMRI also was compared to the SI difference after setting ROI(region of interest) in left and right side of the brain. In conclusion, the SNRs and SI of the 3.0 T PMRI showed higher than those at 1.5 T. In summary, PMRI studies at 3.0 T is provided significantly improved perfusion evaluation when comparing with 1.5 T.

자궁경부암의 고선량율 강내치료 선량계획 분석 (Analysis of High Dose Rate Intracavitary Radiotherapy(HDR-ICR) Treatment Planning for Uterine Cervical Cancer)

  • 채규영
    • Radiation Oncology Journal
    • /
    • 제12권3호
    • /
    • pp.387-392
    • /
    • 1994
  • Purpose : This study was done to confirm the reference point variation according to variation in applicator configuration in each fractioation of HDR ICR. Materials and Methods : We analyzed the treatment planning of HDRICR for 33 uterine cervical cancer patients treated in department of therapeutic radiology from January 1992 to February 1992. Analysis was done with respect to three view points-Interfractionation A point variation, interfractionation bladder and rectum dose ratio variation, interfractionation treatment volume variation. Interfractionation A point variation was defined as difference between maximum and minimum distance from fixed rectal point to A point in each patient. Interfractionation bladder and rectum dose ratio variation was defined as difference between maximum and minimum dose ratio of bladder or rectum to A point dose in each patient, Interfractionation treatment volume variation was defined as difference between miximum and minimum treatment volume which absorbed over the described dose-that is, 350 cGy or 400 cGy-in each patient. Results The mean of distance from rectum to A point was 4.44cm, and the mean of interfractionation distance variation was 1.14 cm in right side,1.09 cm in left side. The mean of bladder and rectum dose ratio was $63.8\%$ and $63.1\%$ and the mean of interfractionation variation was $14.9\%$ and $15.8\%$ respectively. With fixed planning administration of same planning to all fractionations as in first fractionation planning-mean of bladder and rectum dose ratio was $64.9\%$ and $72.3\%$.and the mean of interfraction variation was $28.1\%$ and $48.1\%$ reapectively. The mean of treatment volume was $84.15cm^3$ and the interfractionation variation was $21.47cm^2$. Conclusion : From these data, it was confirmed that there should be adapted planning for every fractionation ,and that confirmation device installed in ICR room would reduce the interfractionation variation due to more stable applicator configuration.

  • PDF

BRISK 기반의 눈 영상을 이용한 사람 인식 (Person Recognition using Ocular Image based on BRISK)

  • 김민기
    • 한국멀티미디어학회논문지
    • /
    • 제19권5호
    • /
    • pp.881-889
    • /
    • 2016
  • Ocular region recently emerged as a new biometric trait for overcoming the limitations of iris recognition performance at the situation that cannot expect high user cooperation, because the acquisition of an ocular image does not require high user cooperation and close capture unlike an iris image. This study proposes a new method for ocular image recognition based on BRISK (binary robust invariant scalable keypoints). It uses the distance ratio of the two nearest neighbors to improve the accuracy of the detection of corresponding keypoint pairs, and it also uses geometric constraint for eliminating incorrect keypoint pairs. Experiments for evaluating the validity the proposed method were performed on MMU public database. The person recognition rate on left and right ocular image datasets showed 91.1% and 90.6% respectively. The performance represents about 5% higher accuracy than the SIFT-based method which has been widely used in a biometric field.

농흉의 임상적 고찰: 59례 보 (Clinical evaluation of thoracic empyema: review of 59 cases)

  • 김현순
    • Journal of Chest Surgery
    • /
    • 제15권3호
    • /
    • pp.274-277
    • /
    • 1982
  • A Clinical analysis of 59 patients of thoracic empyema was done who were received surgical intervention at dept. of thoracic surgery of the C.A.F.G.H. in the period of 2.5 years from January 1979 to June 1982. Occurrence ratio of Left and Right side pleural cavity of empyema was 1: 1.4. The predisposing factors of empyema were pulmonary Tbc. [49%], Chest pain [25%], Cough [8%], in order. B.P.F. was associated with empyema in 5 cases. The pleural cavity empyema was treated with several surgical procedures and conservative measures. Among of the 59 cases, the 30 cases [50%] were treated with decortication, 12 cases [20%] with closed thoractomy drainage, 9 cases with frequent thoracenteses, 5 cases with partial decortication and thoracoplasty and 3 cases with open thoracostomy tube drainage. Among of the 59 cases thoracic empyema, the full recovery were in 32 cases [54%], partial recovery in 20 cases [34%], not improved in 3 cases [5%] and 3 cases were died. The mortality rate was 5% and the recovery rate was 89%.

  • PDF

Universal User Interface Design of ATM Touch Screen Based on the Reaction Time

  • Kim, Yong Hwan;Jeong, Byung Yong;Park, Myoung Hwan
    • 대한인간공학회지
    • /
    • 제35권5호
    • /
    • pp.403-411
    • /
    • 2016
  • Objective: This study is concerned with the user interface (UI) design of touch screen based on the reaction time of Automated Teller Machine (ATM) user. Background: Adopting the touch screen technology, the ATM service has recently established a new user interface different from the existing button-type interface. Method: Experiments were conducted by simulating ATM touch screen layouts, and layouts were focused on location of menu buttons (left and right, top and bottom), number of menu buttons (8 and 12 buttons). Results: The results show that there are significant differences in correction ratio and reaction time by user groups, types of menu location, and the number of buttons. Conclusion and Applications: The results of this study can be used to provide baseline information for the interface design of ATM touch screen and the age differences in reaction time.

Design Method of a Circularly-Polarized Antenna Using Fabry-Perot Cavity Structure

  • Ju, Jeong-Ho;Kim, Dong-Ho;Lee, Wang-Joo;Choi, Jae-Ick
    • ETRI Journal
    • /
    • 제33권2호
    • /
    • pp.163-168
    • /
    • 2011
  • A Fabry-Perot cavity (FPC) antenna producing both high-gain and circularly-polarized (CP) behavior is proposed. To increase antenna gain and obtain CP characteristics, a superstrate composed of square patches with a pair of truncated corners is placed above the linearly polarized patch antenna with an approximately half-wavelength distance from the ground plane at the operating frequency. The proposed antenna has the advantages of high gain, a simple design, and an excellent boresight axial ratio over the operating frequency bandwidth. Moreover, used in an FPC antenna, the proposed superstrate converts a linear polarization produced by a patch antenna into a circular polarization. In addition, the cavity antenna produces left-hand circular-polarization and right-hand circular-polarization when a patch antenna inside the cavity generates x-direction and y-direction polarization, respectively. The measured and simulated results verify the performance of the antenna.

Three-dimensional morphometric study on the retromolar pad

  • Min-Sang Cha;Dae-Gon Kim;Yoon-Hyuk Huh;Lee-Ra Cho;Chan-Jin Park
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.302-314
    • /
    • 2023
  • PURPOSE. The aim of this study was to classify the shapes of retromolar pads and assess their morphometric differences using a 3D model. MATERIALS AND METHODS. Two hundred fully edentulous or Kennedy Class I partially edentulous patients (400 retromolar pads) were enrolled. Scan data of the definitive mandibular casts produced through functional impressions were obtained using a 3D laser scanner. Seven parameters (transverse diameter, longitudinal diameter, transverse-contour length, longitudinal-contour length, longitudinal/transverse diameter ratio, longitudinal/transverse-contour length ratio, and angle of the retromolar pad line to the residual alveolar ridge line) were measured using image analysis software. Subsequently, the pads were classified according to the shape. Statistical analyses were performed using 95% confidence intervals. RESULTS. Classifying the retromolar pads into three shapes led to high intra-examiner reliability (Cronbach's alpha = 0.933). The pear shape was the most common (56.5%), followed by oval/round (27.7%) and triangular (15.8%) shapes. There were no significant differences between the left and right sides according to the shape and no significant differences in any parameter according to age. The transverse diameter and longitudinal/transverse diameter ratio differed between sexes (P < .05). The triangular shape had a significantly different transverse diameter, transverse-contour length, longitudinal/transverse diameter ratio, and longitudinal/transverse-contour length ratio compared with the pear and oval/round shapes (P < .05). CONCLUSION. From a clinical reliability standpoint, classifying retromolar pads into three shapes (oval/round, pear-shaped, and triangular) is effective. The differences in the sizes among the shapes were attributed to the transverse measurement values.

치아회분(齒牙灰粉)과 도재(陶材) 복합(複合) 매식체(埋植體)에 관(關)한 광학현미경(光學顯微鏡) 급(及) 주사전자현미경적(走査電子顯微鏡的) 연구(硏究) (A Light and Scanning Electron Microscopic Study on the Implant of Tooth Ash-Porcelain Mixture)

  • 조영학
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.33-50
    • /
    • 1984
  • The purpose of this study was to investigate whether the ashed tooth powder is utilized as an alternative material of the implant to recovery the bony defect. For this purpose its biocompatibility was evaluated comparing to the synthetic calcium phosphate compounds, such as Syntograft and Calcitite, as well as the vacuum firing porcelain (Ceramco Inc.) which is anticipated to use as a matrix to aid sintering. Bony defects to exposure the bone marrow, $3{\times}5$ mm in size, were created in the right and left tibias of fifteen rabbits, and then the ashed tooth powder at $950^{\circ}C$, the porcelain powder, Syhtograft and Calcitite were inserted in the defects of twelve rabbits of the experimental group and the blood clot only was filled in the defects of three rabbits of the control group. The experimental and control rabbits were sacrificed at 1st, 2nd 3rd week after implantation and the histologic examination was performed. The ashed tooth powder in order to make the needed form of the implant was molded using the cylindrical mold 1 cm high, 1 cm in diameter under the pressure of $1000kg/cm^2$ and the ashed tooth powder was sintered at $1100^{\circ}C$ for 1 hour and the mixture of the porcelain powder and the ashed tooth powder at the weight ratio of 7:3, 6:4, 5:5, 4:6 were molded in the same manner and were sintered at $925^{\circ}C$. From this sintered material, square shaped implants were prepared in the dimension of $2{\times}4{\times}6mm$. The prepared implants were surgically placed in the subperiosteum of lateral surfaces of the right and left mandibular bodies. The dogs were sacrificed at 4 weeks, and then the specimens were examined using the light and scanning electron microscopes. The results of this study were obtained as follows: 1. Any inflammatory response was not noted after implanting of the ashed tooth powder, Syntograft, Calcitite and the porcelain powder during the whole experimental period after implantation. 2. Induction of the new bone formation was significantly shown in the ashed tooth powder, Syntograft and Calcitite. 3. The more the porcelain powder was contained in the implants, the more the porosity was and the bigger the pore size was under the scanning electron microscope. And there was ingrowing of the fibrous connective and the osteoid tissue. 4. The osteoid tissues were found to be directly fused to the implant of the ashed tooth powder, and the mixture implant of the porcelain powder and the ashed tooth powder at the weight ratio of 4:6 under the light and scanning electron microscopes.

  • PDF

동북대학 치학부속병원 악구강기능치료부에 있어서 구순구개열 환자의 임상통계 -1987년부터 2002년까지- (A 17- Year Clinicostatistical Analysis of Cleft Lip and/or Palate Patients in Clinics for Maxillo-Oral Disorders, Tohoku University Dental Hospital)

  • 문철현;행지성자
    • 대한구순구개열학회지
    • /
    • 제7권1호
    • /
    • pp.35-46
    • /
    • 2004
  • The frequency of abnormality at birth is average 1-1.5%, and of these, cleft lip & palate is known to be the most frequent congenital abnormality, Cleft is considered to be due to multi-factorial heredity correlated with genetic and environmental factors, Cleft patients require the collaborative treatment with several medical departments, Clinics for Maxillo-Oral Disorders of Tohoku University Dental Hospital performs the total managements related to such as occlusion and language for the patients with congenital maxilla-facial abnormality, This study examined the patients with cleft lip and/or palate who came to the Clinics for Maxilla-Oral Disorders of Tohoku University Dental Hospital for the past 17 years from Jan. 1987 to Dec, 2002, and had the results as follows, 1. Annual mean number of patients The annual mean number of the patients for 17 years from Jan, 1987 to Dec, 2002 was 91 patients, ranging from 63 minimum to 116 maximum, 2, Gender and types of cleft There were 747(51%) males and 709(49%) females, with a male to female ratio 1,05:1. CLP was the most frequent cleft type as shown in 616 patients, and other patients manifested different complaints such as CL, CP, SMCP and MC in order. 3. The laterality in cleft type The lip cleft was frequently expressed orderly on left, right and both sides of CL patients while orderly being shown on left, both and right sides of CLP patients. Accordingly, lip cleft was most commonly found on the left side. 4. Address at first visit Of 1,456 subjects, 850(58.4%) patients were residing in Miyagi Prefecture, where this hospital is located. 5. Age at first visit 615(42.2%) patients came to the hospital at their age younger than 1 year old, comprising 282(19.4%) patients age younger than 2 months old and 333(22.9%) patients age between 2 month old and 1 year old. 6. Mother's age at birth For the mother's age at birth, 526(39.9%) patients were at the age of 25 to 30 years old, and 17(1.3%) patients were over 40 years old. 7. Birth weight 34.3%(443 patients) had a birth weight of 2500-3000gm and 56.0%(724 patients) had a 3000-4000gm. It was also found that 7.9%(102 patients) had a birth weight of less than 2500gm. 8. Familial expression The frequency of familial expression was 6.5%(94 patients).

  • PDF

Echocardiographic evaluation of heart failure in dogs with myxomatous mitral valve disease: a retrospective study

  • Han, Donghyun;Lee, Dong-Guk;Jung, Dong-In
    • Journal of Biomedical and Translational Research
    • /
    • 제19권4호
    • /
    • pp.79-85
    • /
    • 2018
  • Echocardiography is one of the most useful diagnostic techniques for differentiating heart disease as well as mitral valve lesion. Forty client-owned small breed dogs (weight, 2.3-13.2 kg) aged between 8-17 years with myxomatous mitral valve degeneration (MMVD) were included in the present study. The diagnosis of MMVD in dogs was made based on the clinical signs, chest radiography data, and echocardiographic findings. Echocardiographic examinations were conducted in accordance with recommended standards for dogs. M-mode, Doppler, and 2D echocardiography were performed in left and right lateral recumbency. 2D echocardiography was used to measure LA and Ao diameter from 2D short axis at the level of the aortic valve. In the comparison of conventional echocardiography indices in dogs with different stages of heart failure with MMVD, significant differences were observed in E/A ratio (p=0.005), EDV (p<0.001), EDVI (p<0.001), E-peak velocity (p= 0.001), ESV (p=0.028), ESVI (p=0.004), LA (p<0.001), LA/Ao Ratio (p<0.001), LVIDd (p<0.001), LVIDd/Ao Ratio (p<0.001), LVIDs (p=0.036), LVIDs/Ao Ratio (p=0.002), and MR Velocity (p=0.026). In addition, distinct correlations were found in EDV (r=0.712), LA/Ao ration (r=0.830), LVIDd (r=0.724), and LVIDd/Ao ratio (r=0.759). This study found that known conventional echocardiographic indices, including EDV, LA/Ao ratio, LVIDd dimension, and LVIDd/Ao ratio correlated with the severity of MMVD in point of significant differences and distinct correlations.