• Title/Summary/Keyword: Lee-sigma

Search Result 963, Processing Time 0.03 seconds

The Analysis of Meterological Environment over Jeju Moseulpo Region for HALE UAV (장기체공무인기를 위한 제주도 모슬포 지역의 기상환경 분석)

  • Cho, Young-Jun;Ahn, Kwang-Deuk;Lee, Hee-Choon;Ha, Jong-Chul;Choi, Reno K.Y.;Cho, Chun-Ho;Kim, Su-Bo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.469-477
    • /
    • 2015
  • In this study, the characteristics of main wind direction, vertical temperature and wind speed profile near the Moseulpo airfield for HALE UAV(High Altitude Long Endurance Unmaned Aerial Vehicle) is investigated. The results are summarized as follows, main wind direction is governed by air mass according to season and local wind such as land-sea breeze. The directions of landing and take-off of HALE UAV will be selected as the south-east direction in June ~ August, north-west direction in October ~ March, and south-east direction at daytime in April ~ May, September. Annual variation of temperature at 100 hPa showed that temperature in summer season is lower than winter season. On the other hands, wind speed at 250 hPa in winter season is higher than summer season. The threshold values of temperature and wind speed for HALE UAV flight are $-75^{\circ}C$ and $90ms^{-1}$, which were determined by 5 % frequency value($1.96{\sigma}$), respectively.

Removal of Nitrosomethylamine at Extremely Low Concentration by Powdered Activated Carbon (분말활성탄을 이용한 극미량 농도 Nitrosomethylamine의 흡착 제거)

  • Lee, Sung-Bum;Yoon, Yeo-Min;Choi, Chang-Kyoo;Kim, Moon-Il
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.413-416
    • /
    • 2008
  • Recently, the results of vital tissue test showed that nitrosodimethylamine (NDMA) as a disinfection by-product (DBP), could be regarded as a carcinogen because a tumor was observed in organs. U.S.EPA indicated 0.7 ng/L as exposure concentration of NDMA based on a risk assessment target with a lifetime cancer risk of $10^{-6}$. Several recent studies have shown that UV oxidation could remove NDMA. However, UV oxidation is uneconomical and can reform NDMA after treating. In addition, the treatment mechanism of adsorption has not been founddue to the uncertainty of NDMA pathway. In addtion, NDMA has a radioisotope $^{14}C$-labeled which can be analyzed at low concentration of NDMA by Liquid Scintillation Counter (LSC). This study has investigated NDMA determination using LSC at an extremely low range from 1 to 100 ng/L and NDMA removal by powdered activated carbon (PAC) adsorption. For $^{14}C$-NDMA by LSC, the highest correlation over 99% between count number and NDMA concentrationwas obtained with possibility of $^{14}C$-NDMA concentration up to 1 ng/L. In the presence of PAC ranging from 50 to 10,000 mg/L, $^{14}C$-NDMA was removed from 18% to 97% for Sigma-Aldrich corporation (S-A co.) and from 9% to 93% by PAC for Daejung corporation (Dj co.). Hence it was found that the removal efficiency by PAC adsorption could vary depending on PAC types from different companies. For PAC adsorption capacity of $^{14}C$-NDMA using the Freundlich isotherm, $K_f$ and 1/n of PAC from S-A co. were $2.67\times10^{-3}$ ng/mg and 1.009, while those of PAC from Dj co. were $1.30\times10^{-3}$ ng/mg and 0.994, respectively. Thus, PAC from S-A co. showed twice higher adsorption capacity than Dj co.

  • PDF

Fabrication and dielectric properties of $LaAlO_3-BaZrO_3$ perovskites ($LaAlO_3-BaZrO_3$계 perovskites의 제조 및 유전특성)

  • Lee, So-Hee;Kim, Shin;Shin, Hyun-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.325-325
    • /
    • 2007
  • The perovskites in the $LaAlO_3-BaZrO_3$ system (i.e., $(1-x)LaAlO_3-xBaZrO_3$ were fabricated by a solid state reaction and their dielectric properties were investigated. For the compositions of x=0.1~0.9, the mixture of $LaAlO_3$ with a rhombohedral structure and $BaZrO_3$ with a cubic was observed when the sintering was conducted at $1500^{\circ}C$, indicating that the solubility of constituent elements was very low and a narrow solid solution region might exist. The large difference of ionic radii between $La^{3+}$ ion (0.136nm, C.N.=12) and $Ba^{2+}$ ion (0.161nm) or $Al^{3+}$ ion (0.0535nm, C.N.=6) and $Zr^{4+}$ ion (0.072nm) might hinder the mutual substitution. Within the compositions of x=0~0.7, the dielectric constant of the mixture increased with the amount of $BaZrO_3$, i.e., x value, which was in good agreement with the logarithmic mixing rule (In $_{r,i}={\Sigma}v_iln\;_{r,i}$). The increase in $BaZrO_3$ doping decreased $Q{\times}f$ value significantly due to the low $Q{\times}f$ value of $BaZrO_3$ itself, a poor microstructure of the mixture with an increased grain boundary area per volume, and defects in the cation and oxygen sub-lattices which were respectively caused by the evaporation of barium during the sintering process and the substitution of Ba on La-site or Al on Zr-site.

  • PDF

Analysis of Simple Creep Stress Calculation Methods for Creep Life Assessment (크리프 수명 평가를 위한 간략 크리프 응력 산출 방법론 분석)

  • Seo, Jun Min;Lee, Han Sang;Kim, Yun Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.703-709
    • /
    • 2017
  • Creep analysis takes much more time than elastic or elastic-plastic analysis. In this study, we conducted elastic and elastic-plastic analysis and compared the results with creep analysis results. In the elastic analysis, we used primary stress, which can be classified by the $M{\alpha}-tangent$ method and stress intensities recommended in the ASME code. In the elastic-plastic analysis, we calculated the parameters recommended in the R5 code. For the FE models, a bending load, uniaxial load, and biaxial load were applied to the cross shaped welded plate, and a bending load and internal pressure were applied to the elbow pipe. To investigate the element size sensitivity, we conducted FE analysis for various element sizes for the cases where bending load was applied to the cross shaped welded plate. There was no significant difference between the creep stress and the alternative methods; however, in the $M{\alpha}-tangent$ method, the results were affected by the element size.

Disaster risk prediction under the condition of future climate change (미래 기후변화에 따른 재해위험도 예측)

  • Lee, Jeong-Ju;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.125-125
    • /
    • 2011
  • 본 연구에서는 기후변화에 의한 자연재해 취약성을 정량적으로 분석하기 위하여 기상인자와 재해발생으로 인한 피해액의 상관관계를 이용하였다. 재해로 인한 피해액은 1994년부터 2008년까지 15년간 전국 시군별로 피해액을 집계한 자료를 이용하였으며, 우리나라 58개 강우관측소의 일강수량 자료를 이용하여 재해에 영향을 줄 수 있는 네 가지 인자를 추출하였고, 연도별 태풍 발생 횟수도 하나의 기상인자로 고려하였다. 피해액의 규모는 가뭄, 화재, 태풍 및 해일 등 재해발생 유형에 따라서도 영향을 받겠지만, 기후변화 시나리오에 의해 예측할 수 있는 대표적인 미래 추정값은 강수량과 온도 등이며, 결국 재해발생 유형별 시나리오에 의한 재해규모 예측이 아닌 기후변화 시나리오에 의한 미래 재해발생 규모 모형을 구축하기 위해서는 관련 인자로서 강수량으로부터 추출한 인자들을 고려할 수밖에 없을 것이다. 일강수량으로부터 추출한 네 가지 영향인자들은 80mm이상 일강수량 발생일수, 80mm이상 일강수량의 합, 80mm이상 강우의 발생 간격이 30일 이하인 횟수 및 연최대강수량이다. 우선 광역시와 도별로 전국 58개 관측소를 분류하고, 해당 관측소들로부터 추출된 인자들의 평균값을 이용하여 연구를 진행하였다. 미래 강수량 자료는 국립기상연구소의 A2시나리오를 통계학적 Downscaling을 통해 재생산한 자료를 이용하였다. 예측모형은 Bayesian 모형을 기반으로 DEXP(double exponential distribution) 확률분포를 이용하였다. 재해피해액 를 아래와 같이 비정상성 모형으로 구성하였으며, 위치매개 변수의 확률분포를 네 가지 기상인자에 의한 회귀식으로 구성하였다. Y damage costs) = dexp(${\mu}(t),\tau(t)$) $p({\mu}(t))\sim(abs({\alpha}+{\alpha}_1X_1+{\alpha}_2X_2+{\alpha}_3X_3+{\alpha}_4X_4,\;\sigma_{\alpha}^2)$ $p(\tau){\sim}G(k,s)$.

  • PDF

Analysis of High Temperature Deformation Stability and Properties of Duplex Stainless Steels According to Annealing Temperature (듀플렉스 스테인레스 소재의 고온 변형 안정성 및 어닐링 온도에 따른 특성 분석)

  • Kwon, Gi Hyoun;Na, Young-Sang;Yoo, Wee-Do;Lee, Jong-Hoon;Park, Yong-Ho
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.7
    • /
    • pp.495-502
    • /
    • 2012
  • The aim of this study was to analyze high temperature deformation stability and properties of duplex stainless steels(DSS) according to annealing temperature. In order to analyze high temperature deformation stability, a number of compression tests were carried out with a stain rate of $10^{-2}s^{-1}{\sim}10s^{-1}$ up to a compression ratio of 50% in a temperature range of $950^{\circ}C-1300^{\circ}C$. The analysis of high temperature deformation stability of DSS was performed based on the Ziegler model. In order to analyze the high temperature properties of DSS, annealing treatments were conducted by isothermal holding for 1 hr at $950^{\circ}C$ to $1300^{\circ}C$ with $50^{\circ}C$ intervals followed by water cooling. The hardness and tensile tests were performed on specimens with different volume fractions of constituent phases, such as austenite, ferrite and sigma. The hardness and tensile strength of 2507 according to the annealing temperature are better than those of 2205. The strain rate sensitivity and Ziegler parameter are higher in 2205 than in 2507 as a whole, which implies that 2205 is better than 2507 in terms of forgeability at high temperature.

Iodine Sorption Complexes of Partially Cobalt(II) Exchanged Zeolite A. Two Crystal Structures of $Co_{3.5}Na_5Si_{12}Al_{12}O_{48}\cdot2.5I_2\;and\;Co_{3.5}Na_5Si_{12}Al_{12}O_{48}\cdot5.0I_2$

  • Kim, Yang;Lee, Suk-Hee;Seff, Karl
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.5
    • /
    • pp.426-430
    • /
    • 1989
  • Two crystal structures of iodine sorption complexes of dehydrated partially Co(Ⅱ )-exchanged zeolite A, $Co_{3.5}Na_5-A{\cdot}xI_2$, x = 2.5 and 5.0, have been determined by single crystal X-ray diffraction techniques. Both structures were solved and refined in cubic space group, Pm3m at $21(1)^{\circ}C$. The structures of $Co_{3.5}Na_5-A{\cdot}2.5I_2$(a = 12.173(1) ${\AA}$) and $Co_{3.5}Na_5-A{\cdot}5.0I_2$(a = 12.130(1) ${\AA}$) were refined to the final error indices, $R_1$ = 0.081 and $R_2$ = 0.077 with 261 reflections and $R_1$ = 0.103 and $R_2$ = 0.112 with 225 reflections, respectively, for which I>3${\sigma}$(I). In both structures, 3.5 $Co^{2+}$ ions and 4.5 $Na^+$ ions per unit cell lie at two crystallographically different 6-ring positions. 0.5 $Na^+$ ion lines in an 8-oxygen ring plane. Dehydrated $Co_{3.5}Na_5$-A sorbs 2.5 iodine molecules per unit cell at $70^{\circ}C$ (vapor pressure of $I_2$ is ca. 8.3 torr) within 30 minutes and 5 iodine molecules per unit cell at $80^{\circ}C$ (vapor pressure of $I_2$ is ca. 14.3 torr) within 24 hours. Each iodine molecule makes a close approach, along its axis to framework oxygen atom with I-I-O = $175^{\circ}$.

Numerical Analysis for the Effect of Flow Skirt Geometry on the Flow Distribution in the Scaledown APR+ (유동 덮개 형상이 축소 APR+ 내부 유동분포에 미치는 영향에 대한 수치해석)

  • Lee, Gong Hee;Bang, Young Seok;Woo, Sweng Woong;Kim, Do Hyeong;Kang, Min Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.269-278
    • /
    • 2013
  • In this study, in order to examine the applicability of computational fluid dynamics with the porous model to the analysis of APR+ (Advanced Power Reactor Plus) internal flow, simulation was conducted with the commercial multi-purpose computational fluid dynamics software, ANSYS CFX V.14. In addition, among the various reactor internals, the effect of flow skirt geometry on reactor internal flow was investigated. It was concluded that the porous model for some reactor internal structures could adequately predict the hydraulic characteristics inside the reactor in a qualitative manner. If sufficient computation resource is available, the predicted core inlet flow distribution is expected to be more accurate, by considering the real geometry of the internal structures, especially located in the upstream of the core inlet. Finally, depending on the shape of the flow skirt, the flow distribution was somewhat different locally. The standard deviation of the mass flow rate (${\sigma}$) for the original shape of flow skirt was smaller, than that for the modified shape of flow skirt. This means that the original shape of the flow skirt may give a more uniform distribution of mass flow rate at the core inlet plane, which may be more desirable for the core cooling.

Effects of post weld heat treatment conditions on localized corrosion resistance of super duplex stainless steel tube used for thermal power plant applications (화력발전용 슈퍼 듀플렉스 스테인리스 강 조관재의 용접 후 열처리 조건이 국부부식 저항성에 미치는 영향)

  • Lee, Jun Ho;Park, Jin sung;Cho, Dong Min;Hong, Seung Gab;Kim, Sung Jin
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.5
    • /
    • pp.248-259
    • /
    • 2021
  • This study examined the influence of post weld heat treatment (PWHT) conditions on corrosion behaviors of laser-welded super duplex stainless steel tube. Due to the high cooling rate of laser welding, the phase fraction of ferrite and austenite in the weld metal became unbalanced significantly. In addition, the Cr2N particles were precipitated adjacent to the fusion line, which can be susceptible to the localized corrosion. On the other hand, the phase fraction in the weld metal was restored at a ratio of 5:5 when exposed to temperatures above 1060 ℃ during the post weld heat treatment. Nevertheless, the high beltline speed during the PWHT, leading to the insufficient cooling rate, caused a precipitation of σ phase at the interface between ferrite/austenite in both weld metal and base metal. This resulted in the severe corrosion damages and significant decrease in critical pitting temperature (CPT), which was even lower than that measured in as-welded condition. Moreover, the fraction of σ phase in the center region of post weld heat treated steel tube was obtained to be higher than in the surface region. These results suggest that the PWHT conditions for the steel tube should be optimized to ensure the high corrosion resistance by excluding the precipitation of σ phase even in center region.

Comparison of Recovery Rate and Fatty Acid Composition of Dried Sea Cucumbers Apostichopus japonicus Dried by Hybrid Heat Pump Decompression and by Hot Air (2종류의 건조기로 제조한 돌기해삼(Apostichopus japonicus)의 복원율과 지방산조성 비교)

  • Jeong, U-Cheol;Jin, Feng;Anisuzzaman, Md;Choi, Byeong-Dae;Jung, Hyun-Chol;Lee, Sang-Ro;Kang, Seok-Joong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.3
    • /
    • pp.232-240
    • /
    • 2019
  • Approximately 80% of the world's sea cucumbers Apostichopus japonicas are processed into dried sea cucumbers. The hot air-drying method is currently used in industry, but it has many problems, such as a short drying time, severe browning, high nutrition loss, and low recovery. In this study, the moisture absorption rate, dry recovery rate, and lipid nutrient composition of sea cucumber dried by heat pump decompression and with a hybrid dryer were investigated. The moisture absorption rates for hybrid-dried sea cucumbers at 24, 48, 72, 96, and 120 h were 241.3%, 427.7%, 652.0%, 721.0%, and 742.2%, respectively. The moisture absorption rates for hot air-dried sea cucumbers were 155.8%, 240.0%, 390.3%, 655.5%, and 667.4%, respectively. Thus, moisture absorption was faster and greater with hybrid drying than with hot air drying. The dry recovery rate at 24 h was greater for hybrid-dried sea cucumber (70.7%) than for hot air-dried sea cucumber (59.8%). Saturated fatty acid contents of the hybrid- and hot air-dried sea cucumbers were 30.0% and 37.5%, respectively. Moreover, greater ${\Sigma}n-3$ polyunsaturated fatty acid content was found in hybrid-dried sea cucumber (15.8%) than in hot air-dried sea cucumber (11.7%).