• Title/Summary/Keyword: Leaks

Search Result 445, Processing Time 0.023 seconds

Research on Rapid Disaster Prevention Measures due to Leakage During Transport of Hydrochloric Acid Tank Lorry (염산 탱크로리 운송 중 누출에 따른 신속 방재방안 연구)

  • Byoung-chan Moon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.213-221
    • /
    • 2024
  • Purpose: The purpose is to find the optimal way to quickly block the leak in the event of a leak accident in a tank lorry transporting hydrochloric acid aqueous solution, a hazardous chemical, and to carry out effective disaster prevention work to minimize damage caused by the leak. Method: We organized the overall characteristics of hydrochloric acid and accidents that occurred during transportation by accident type and cause, and created a small tank that can be tested assuming a leak situation in a hydrochloric acid tanker, creating an environment similar to the leak situation, and leaking in various ways. I would like to experiment and organize blocking methods. Result: Through experiments, an effective leak blocking method was confirmed. We would like to summarize measures to quickly block a leak in the event of a leak and present the optimal disaster prevention plan that can be applied at the accident site. Conclusion: It has been confirmed that using a combination of adhesive tape and magnets is more effective in blocking leaks. Rapid response is possible by repeatedly training business emergency response teams and product transporters to appropriately select and respond to leak-blocking equipment. Additional research on various leak prevention methods is needed in the future.

A Study of Cesium Removal Using Prussian Blue-Alginate Beads (프러시안 블루-알지네이트 비드를 이용한 세슘 제거 연구)

  • So-on Park;Su-jung Min;Bum-kyoung Seo;Chang-hyun Roh;Sang-bum Hong
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.89-93
    • /
    • 2024
  • Accidents at nuclear facilities and nuclear power plants led to leaks of large amounts of radioactive substances. Of the various radioactive nuclides released, 137Cs are radioactive substances generated during the fission of uranium. Therefore, due to the high fission yield (6.09%), strong gamma rays, and a relatively long half-life (30 years), a rapid and efficient removal method and a study of adsorbents are needed. Accordingly, an adsorbent was prepared using Prussian blue (PB), a material that selectively adsorbs radioactive cesium. As a result of evaluating the adsorption performance with the prepared adsorbent, it was confirmed that 82% of the removal efficiency was obtained, and most of the cesium was rapidly adsorbed within 10 to 15 minutes. The purpose of this study was to adsorb cesium using the Prussian blue alginate bead and to compare the change in detection efficiency according to the amount of adsorbent added for quantitative evaluation. However, in this case, it is difficult to determine the detection efficiency using a standard source with the same conditions as the measurement sample, so the efficiency change of the HPGe detector according to the different heights of Prussian blue was calculated through MCNP simulation using certified standard materials (1 L, Marinelli beaker) for radioactivity measurement. It is expected to derive a relational equation that can calculate detection efficiency through an efficiency curve according to the volume of Prussian blue, quantitatively evaluate the activity at the same time as the adsorption of radioactive nuclides in actual contaminated water and use it in the field of nuclear facility operation and dismantling in the future.

Increased ERCP volume improves cholangiogram interpretation: a new performance measure for ERCP training?

  • Shyam Vedantam;Sunil Amin;Ben Maher;Saqib Ahmad;Shanil Kadir;Saad Khalid Niaz;Mark Wright;Nadeem Tehami
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.426-433
    • /
    • 2022
  • Background/Aims: Cholangiogram interpretation is not used as a key performance indicator (KPI) of endoscopic retrograde cholangiopancreatography (ERCP) training, and national societies recommend different minimum numbers per annum to maintain competence. This study aimed to determine the relationship between correct ERCP cholangiogram interpretation and experience. Methods: One hundred fifty ERCPists were surveyed to appropriately interpret ERCP cholangiographic findings. There were three groups of 50 participants each: "Trainees," "Consultants group 1" (performed >75 ERCPs per year), and "Consultants group 2" (performed >100 ERCPs per year). Results: Trainees was inferior to Consultants groups 1 and 2 in identifying all findings except choledocholithiasis outside the intrahepatic duct on the initial or completion/occlusion cholangiogram. Consultants group 1 was inferior to Consultants group 2 in identifying Strasberg type A bile leaks (odds ratio [OR], 0.86; 95% confidence interval [CI], 0.77-0.96), Strasberg type B (OR, 0.84; 95% CI, 0.74-0.95), and Bismuth type 2 hilar strictures (OR, 0.81; 95% CI, 0.69-0.95). Conclusions: This investigation supports the notion that cholangiogram interpretation improves with increased annual ERCP case volumes. Thus, a higher annual volume of procedures performed may improve the ability to correctly interpret particularly difficult findings. Cholangiogram interpretation, in addition to bile duct cannulation, could be considered as another KPI of ERCP training.

A Study on the Institutional Improvement Directions of Industrial Security Programs: Focused upon Policies and Practices in the U.S. (산업보안의 제도적 발전방안 연구: 미국 사례를 중심으로)

  • Choi, Justin Jin-Hyuk
    • Korean Security Journal
    • /
    • no.22
    • /
    • pp.197-230
    • /
    • 2010
  • This study examined the institutional improvement directions of industrial security programs, particularly focusing upon policies and practices in the U.S., to enhance the effectiveness of industrial security programs in Korea. This study also aimed to investigate the significance of institutional and/or policy implementations in preventing economic espionage attempt. Data leakage and/or loss of trade secrets in corporations has been a scary proposition and a serious headache to both the CEOs and the CSOs(Chief Security Officers). Security professionals or practitioners have always had to deal with data leakage issues that arise from e-mail, instant messaging(IM), and other Internet communication channels. In addition, with the proliferation of wireless and mobile technology, it's now much easier than ever for loss by data breaches to occur, whether accidentally or maliciously or even by an economic espionage attempt. The researcher in this study used both a case study and a comparative research to analyze the different strategies and approaches between the U.S. and Korea in regard of implementing policies to mitigate damages by economic espionage attempts and prevent them from occurring. The researcher first examined the current policies and practices in the U.S. in terms of federal government's and agencies' approach and strategies on industrial security programs and their partnerships with private-commercial-sectors. The purpose of this paper is to explain and suggest selected findings, and a discussion of actions to be taken on implementing a proactive and tactical approach to enhance the effectiveness of industrial security programs to fight against information loss or data leaks. This study used case reviews, literatures, newspapers, articles, and Internet resources relating to the subject of this study for triangulation of data. The findings during this research are as follows. This research suggests that both the private and the governmental sector should closely cooperate in the filed of industrial security to strengthen its traditional prevention strategies and reduce opportunities of economic espionage as well. This study finally recognizes both the very importance of institutional development led by the Government in preventing economic espionage attempts and its effectiveness when properly united with effective industrial security programs.

  • PDF

Clinical Results Following Early Tailoring Thoracoplasty in Patients Undergoing Pulmonary Resection (폐의 부분절제수술를 시술받은 환자에서 조기 변형식 흉곽성형수술에 따른 임상결과)

  • Choi, Soon-Ho;Cha, Byung-Ki;Lee, Mi-Kyung;Park, Kwon-Jae;Lee, Sam-Youn;Choi, Jong-Bum
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.485-491
    • /
    • 2007
  • Background: Thoracoplasty has become a rarity in current clinical practice, although it has been widely employed for well over a century as a procedure for reducing the capacity of the thoracic cavity. Yet we have perform tailoring thoracoplasty following or concomitant with pulmonary resection in 20 patients. The aim of this study is to evaluate the early and late clinical results and also the significance of tailoring thoracoplasty. Material and Method: From March 1995 to June 2005, modified thoracoplasty following or concomitant with pulmonary resection was performed in 20 patients out of a total of 298 pulmonary resections for closing air leaks and for treating persistent pleural space following pulmonary resections, and to tailor the thoracic cavity to accept a diminished lung volume. Of the 20 patients, 14 patients had tailoring thoracoplasty performed concomitant with pulmonary resection, and the remaining 6 patients also had tailoring thoracoplasty performed following pulmonary resection. The subjects ages ranged from 24 to 77 (mean $59.1{\pm}6.4$) and a male preponderance was noted (17 : 3); the number of left and right surgeries was equal. The preoperative primary underlying diseases were lung cancer in 7 patients, pneumothorax with giant bullous change in 6 patients, bronchiectasis in 2 patients, previous pulmonary tuberculosis associated with aspergilloma in 2 patients, empyema with fibrothorax in 2 patients and multiple lung abscesses & destruction due to previous trauma in 1 patient. The operative methods were apicolysis and subperiosteal removal of the 2nd, 3rd and 4th ribs (the costochondral junction to the posterior portions of the ribs) with preservation of the first rib and compression of the anterior chest via cotton bags and elastic bandages. Result: The mean duration of the air leaks after thoracoplasty was $1.6{\pm}0.2$ days (range: $0{\sim}7$ days) and the mean duration of an indwelling chest tube was 7 days (range: $5{\sim}11$ days); the mean duration of hospitalization was $19.2{\pm}2.8$ days (range: $8{\sim}47$ days). The postoperative complications were wound infection (2) and pneumonia (2); reoperation was done due to bleeding (1) in one patient who underwent concomitant thoracoplasty and there was 1 case of wound infection (1) after postresection thoracoplasty. The mortality was 1 patient in the early phase and 4 patients in the late phase. Conclusion: We conclude that tailoring thoracoplasty may be performed to close anticipated persistent pleural spaces and to accommodate the diminished lung volume with acceptable cosmetic results when this procedure is combined with pulmonary resection in selected patients.

Efficacious Pleurodesis with OK-432 Plus Autoblood or OK-432 Against the Pneumothorax with Persistent Air Leak (지속성 기흉에서 OK-432와 자가혈액을 이용한 흉막 유착술의 효과)

  • Kim, Hyoung Soo;Choi, Goang Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.1
    • /
    • pp.72-75
    • /
    • 2006
  • Background : This report reviews our experience with persistent air leaks in the peumothorax that were not considered candidates for surgical treatment in order to evaluate the efficacy and risks of the OK-432 plus autoblood or OK-432 pleurodesis. Material & Methods : From March 2004 to July 2005, 8 consecutive patients who had an air leak in the pneumothorax over 5 days and had been treated with OK-432 plus autoblood or OK-432 pleurodesis. The patients were not considered candidates for surgical treatments because the chest CT findings revealed severe chronic lung disease with multiple bullae and/or bullous changes. A prolonged air leak with/without dead space was treated with either OK-432 plus autoblood or OK-432 pleurodesis. The efficacy and side effects of OK-432 pleurodesis were assessed by determining the duration of the air leak, the number of pleurodesis, the patients' symptoms, measurements of the white blood cell count and the c-reactive protein level. Results : All of eight patients were male and the mean age was $72.4{\pm}8.5$. The mean number of pleurodesis was $1.9{\pm}1.1$ and the mean duration of the air leak was $4.6{\pm}4.6days$ after pleurodesis. Side effects after pleurodesis were encountered in 7 patients, which included a chilling sensation in 7 cases, chest pain in 5 cases, headache in 3 cases, local heat sensation in 2 cases, and fever in 1 case. Leukocytosis was observed in 6 patients, and the mean of WBC count and CRP were $14500{\pm}2100$ and $21.9{\pm}11.4mg/dL$, respectively. Conclusion : Either OK-432 plus autoblood or OK-432 pleurodesis has acceptable side effects, and can be considered a treatment option for persistent air leaks in the pneumothorax that are not candidates for surgical treatment.

International Linkage of CO2 Emissions from Fossil Fuels as Embodied in Foreign Trade and Effects of Economic Policy Measure (국제무역에 함유된 지구온난화 가스 배출의 국제연관구조와 경제적 유인정책의 효과)

  • Chung, Hyun-Sik
    • Environmental and Resource Economics Review
    • /
    • v.13 no.4
    • /
    • pp.621-655
    • /
    • 2004
  • Emission Trading (ET) among Annex I countries as expounded in Kyoto mechanism can be an effective mean to control Greenhouse Gases(GHGs), particularly $CO_2$ emissions from fossil fuels. For the international ET to be an effective tool to reduce the global emissions, however, it presupposes that there are no carbon leakage, i.e. Annex I emitters will purchase emission permits if emitting above caps, rather than importing emission-intensive goods from non-Annex I countries thus inducing the foreigners to emit instead. The extent to which a country leaks carbon through trade can be revealed by its bilateral balance of current accounts and related Balance of Emissions Embodied in Trade (BEET) supplemented by Emission Terms of Trade (ETT). Earlier studies on BEET and ETT relied on few selected countries in a partial equilibrium context, Korea being treated as insignificant though she is not a minor emitter. This paper is an attempt to examine BEET in the global CGE framework and to compare its structural difference across countries, with a special emphasis on South Korea.

  • PDF

A Review on the Performance Criteria of Equipment Required for Asbestos Removal (석면 해체.제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰)

  • Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.212-221
    • /
    • 2013
  • Objectives: Asbestos fibers are accumulated in negative pressure unit (NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from$500m^3/h$ to over $3000m^3/h$. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered (-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer's measuring range should cover less than ${\pm}125$ Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

Dynamic Response of Plate Structure Subject to the Characteristics of Explosion Load Profiles - Part B: Analysis for the Effect of Explosion Loading Time According to the Natural Period for Target Structures - (폭발하중 이력 특성에 따른 판 구조물의 동적응답 평가 - Part B: 고유주기에 따른 폭발하중 지속시간의 영향 분석 -)

  • Kang, Ki-Yeob;Choi, Kwang-Ho;Ryu, YongHee;Choi, JaeWoong;Lee, Jae-Myung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.197-205
    • /
    • 2015
  • Offshore structures for the gas production are exposed to the risk of gas leaks, and gas explosions can result in fatal damages to the primary structures as well as secondary structures. To minimize the damage from the critical accidents, the study of the dynamic response of structural members subjected to blast loads must be conducted. Furthermore, structural dynamic analysis has to be performed considering relationships between the natural frequency of structural members and time duration of the explosion loading because the explosion pressure tends to increase and dissipate within an extremely short time. In this paper, the numerical model based on time history data were proposed considering the negative phase pressure in which considerable negative phase pressures were observed in CFD analyses of gas explosions. The undamped single degree of freedom(SDOF) model was used to characterize the dynamic response under the blast loading. A blast wall of FPSO topside was considered as an essential structure in which the wall prevents explosion pressures from the process area to utility and working areas. From linear/nonlinear transient analyses using LS-DYNA, it was observed that dynamic responses of structures were influenced by significantly the negative time duration.