• 제목/요약/키워드: Leakage volume

검색결과 218건 처리시간 0.021초

편심된 펌프 실의 누설 및 회전체동역학적 해석 (Rotordynamic and Leakage Analysis for Eccentric Annular Seal)

  • 하태웅
    • 한국유체기계학회 논문집
    • /
    • 제4권2호
    • /
    • pp.15-21
    • /
    • 2001
  • Basic equations and their solution procedure we derived for the analysis of an annular pump seal in which the rotor has a large static displacement from the centered position. The Bulk-flow is assumed for a control volume set in the seal clearance and the flow is assumed to be completely turbulent in axial and circumferential direction. Moody's wall-friction-factor formula is used for the calculation of wall shear stresses in the control volume. For the reaction force developed by the seal, linearized zeroth-order and first-order perturbation equations are developed for small motion about an eccentric position. Flow variables are expanded by using Fourier series for the solution procedure. Integration of the resultant first-order pressure distribution along and around the seal defines the 12 elements of rotordynamic coefficients of the eccentric annular pump seal. The results of leakage and rotordynamic coefficients aye presented and compared with the Marquette's experimental results and the San Andres' theoretical analysis.

  • PDF

엇갈린 래버린스 실의 누설량 및 동특성 해석 (Leakage and Rotordynamic Analysis for Staggered-Labyrinth Gas Seal)

  • 하태웅
    • Tribology and Lubricants
    • /
    • 제18권1호
    • /
    • pp.24-33
    • /
    • 2002
  • The basic equations are derived for the analysis of a staggered labyrinth gas seal which are generally used in high performance compressors and steam turbines. The Bulk-flow is assumed for a single cavity control volume and the flow is assumed to be completely turbulent in circumferential direction. Moody's wall-friction-factor formula is used for the calculation of wall shear stresses in the single cavity control volume. For the reaction force developed by the seal, linearized zeroth-order and first-order perturbation equations are developed for small motion about a centered position. Integration of the resultant first-order pressure distribution along and around the seal defines the rotordynamic coefficients of the staggered labyrinth gas seal. Theoretical results of leakage and rotordynamic characteristics for the staggered labyrinth gas seal are compared with those of the plain seal and see-through labyrinth seal.

폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성 (Temperature and Leakage Current Characteristics of Polymeric Surge Arrester with Housing)

  • 조한구;유대훈;이운용;김하나
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-280
    • /
    • 2007
  • In this paper, the ZnO surge arrester performance of power distribution class has been studied under different manufacturing conditions such as housing materials(polymeric, porcelain), interface sealants and one-body molding type. In the recent years, the polymeric ZnO surge arresters have been developed and put into operations based on their excellent characteristics. For polymeric surge arresters, the inner gas volume is extremely small, especially in solid insulation polymeric arresters there are not any gas volume inside arresters in the structure due to polymeric materials are filled into the internal gas volume. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters is investigated with moisture multi-aging test and ingress test. The evaluation techniques are used to inspect the sealing integrity of polymeric arresters, including leakage current, surface temperature, reference voltage and dissipation factor.

Low-dose radiation therapy for massive chylous leakage after subtotal gastrectomy

  • Kim, Sang-Won;Kim, Jung Hoon
    • Radiation Oncology Journal
    • /
    • 제35권4호
    • /
    • pp.380-384
    • /
    • 2017
  • Massive chylous leakage is a rare postoperative complication that can prolong hospital stay and cause secondary morbidities. Conservative management strategies are the treatment of choice; however, radiation therapy (RT) can be used as an alternative for cases that are refractory to conservative treatment. Herein, we report a 69-year-old female patient who suffered from massive chylous leakage after subtotal gastrectomy. Due to persistent massive chylous leakage, she was scheduled to undergo low-dose RT. Radiation was delivered with a daily dose of 1 Gy, using an anterior-posterior and posterior-anterior beam arrangement. The clinical target volume encompassed the entire lymph node area of the D2 dissection. RT was completed at the total dose of 8 Gy because the amount of chylous leakage declined rapidly. Percutaneous drainage tube was removed after 3 days of RT. The patient did not complain of any symptoms related to massive chylous leakage 2 years after the completion of RT.

선형 저밀도 폴리에틸렌과 에틸렌 비닐아세테이트의 혼합비에 따른 체적고유저항 특성 (The Volume Resistivity Properties due to Mixture ratio of Linear Low Density Polyethylene and Ethylene Vinyl Acetate)

  • 박정구;육영수;신현택;신종열;이충호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.552-555
    • /
    • 1999
  • In this paper, the volume resistivity properties due to mixture ration of linear low density polyethylene(LLDPE) and ethylene vinyl acetate(EVA) are studied. Electrodes is composed of upper electrode 37(mm $\Phi$), guardring electrode(inner 55(mm $\Phi$ ), and lower electrode 87(mm $\Phi$ In order to measure the leakage current, We used electrometer and stable oven with temperature controller. Measurement method is to measure the leakage current of next specimen after applying the voltage according to 'Step Apply Methods' for ten minutes. In order to measure the volume resistivity properties, the micro electrometer is used, the range of temperature and applying voltage are 25 to 100[$^{\circ}C$] to 100[V] respectively.

  • PDF

오리피스에서 기체의 표준유량을 이용한 산소와 헬륨의 누설량 측정에 관한 연구 (Study on Leakage Measurements of Oxygen and Helium Using Standard Gas Flow Rates in a Orifice Flow)

  • 이중엽;한상엽;허환일
    • 한국항공우주학회지
    • /
    • 제43권12호
    • /
    • pp.1108-1115
    • /
    • 2015
  • 본 연구에서는 마우스피스 방법을 이용하여 산소의 질량유량 측정과 헬륨의 체적유량 측정에 대한 관계식을 정리하였다. 마우스피스 방법은 상사된 실험식을 이용함으로써 시험비용을 절감할 수 있다. 마우스피스 방법에서는 기체헬륨을 측정하여 용이하게 액체산소의 누설량을 측정할 수 있다. 시제품의 누설량 측정에서 상온과 극저온 상태의 헬륨과 산소간의 누설량 관계를 이해하기 위해 실험을 수행하여 비교하였다. 헬륨의 누설 체적유량[$A.m{\ell}/s$]은 액체상태의 산소 누설의 질량유량[g/s]에 대비하여 174배였다. 실험식과 비교된 계산식은 미국 국립기술표준원의 자료를 이용하여 증명하였다.

단삼(丹蔘)이 뇌조직출혈 흰쥐의 혈액뇌관문 손상에 미치는 영향 (Effects of Salviae Miltiorrhizae Radix on Blood-Brain Barrier Impairment of ICH-Induced Rats)

  • 박창훈;김연섭
    • 대한본초학회지
    • /
    • 제29권1호
    • /
    • pp.19-26
    • /
    • 2014
  • Objectives : This study was performed in order to evaluate the effects of Salviae Miltiorrhizae Radix (SMR) water extract against the cerebral hemorrhage and the blood-brain barrier (BBB) impairment in the intracerebral hemorrhage (ICH). Method : ICH was induced by the stereotaxic intrastriatal injection of bacterial collagenase type IV in Sprague-Dawley rats. SMR was orally given three times every 20 hours during 3 days after the ICH induction. Hematoma volume, water content of brain tissue and volume of evans blue leakage were examined. Myeloperoxidase (MPO) positive neutrophils and tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) were observed with immunofluorescence labeling and confocal microscope. Results : SMR significantly reduced the hematoma volume of the ICH-induced rat brain. SMR significantly reduced the water content of brain tissue of the ICH-induced rat brain. SMR reduced the percentage of the evans blue leakage around the hematoma on the caudate putamen compared to the ICH group, especially on the cerebral cortex. SMR significantly reduced the volume of the evans blue leakage level in the peri-hematoma regions of the ICH-induced rat brain. SMR significantly reduced MPO positive neutrophils in the peri-hematoma regions of the ICH-induced rat brain. SMR reduced the TNF-${\alpha}$ expression in peri-hematoma regions of the ICH-induced rat brain. TNF-${\alpha}$ immuno-labeled cells were coincided with MPO immuno-labeled neutrophils in peri-hematoma regions of the ICH-induced rat brain. Conclusion : These results suggest that SMR plays a protective role against the blood-brain barrier impairment in the ICH through suppression of inflammation in the rat brain tissues.

Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

  • Lee, Jong Kyeom;Kim, Tae Yun;Kim, Hyun Su;Chai, Jang-Bom;Lee, Jin Woo
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1280-1290
    • /
    • 2016
  • This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

누설 인덕턴스를 포함한 DAB 컨버터용 고주파 변압기의 머신러닝 활용한 최적 설계 (Machine-Learning Based Optimal Design of A Large-leakage High-frequency Transformer for DAB Converters)

  • 노은총;김길동;이승환
    • 전력전자학회논문지
    • /
    • 제27권6호
    • /
    • pp.507-514
    • /
    • 2022
  • This study proposes an optimal design process for a high-frequency transformer that has a large leakage inductance for dual-active-bridge converters. Notably, conventional design processes have large errors in designing leakage transformers because mathematically modeling the leakage inductance of such transformers is difficult. In this work, the geometric parameters of a shell-type transformer are identified, and finite element analysis(FEA) simulation is performed to determine the magnetization inductance, leakage inductance, and copper loss of various shapes of shell-type transformers. Regression models for magnetization and leakage inductances and copper loss are established using the simulation results and the machine learning technique. In addition, to improve the regression models' performance, the regression models are tuned by adding featured parameters that consider the physical characteristics of the transformer. With the regression models, optimal high-frequency transformer designs and the Pareto front (in terms of volume and loss) are determined using NSGA-II. In the Pareto front, a desirable optimal design is selected and verified by FEA simulation and experimentation. The simulated and measured leakage inductances of the selected design match well, and this result shows the validity of the proposed design process.

터널 내 수소연료 자동차의 수소 누설로 인한 수소 확산에 대한 수치해석 연구 (THE NUMERICAL SIMULATION OF HYDROGEN DIFFUSION FOR THE HYDROGEN LEAKAGE IN TUNNEL)

  • 안혁진;정재혁;허남건;이문규;용기중
    • 한국전산유체공학회지
    • /
    • 제15권2호
    • /
    • pp.47-54
    • /
    • 2010
  • In the present study, a numerical simulation for the diffusion of hydrogen leakage of FCV(Fuel Cell Vehicle) in a tunnel was performed to aid the assessment of risk in case of leakage accident. The temporal and spatial distributions of the hydrogen concentration around FCV are predicted from the present numerical analyses. Flammable region of 4-74% and explosive region of 18-59% hydrogen by volume was identified from the present results. Factors influencing the diffusion of the hydrogen jet were examined to evaluate the effectiveness of tunnel ventilation system for relieving the accumulation of the leaked hydrogen gas. The distribution of the concentration of the leaked hydrogen for various cases can be used as a database in various applications for the hydrogen safety.