• Title/Summary/Keyword: Leakage signal

Search Result 342, Processing Time 0.023 seconds

A Reconfigurable Directional Coupler Using a Variable Impedance Mismatch Reflector for High Isolation

  • Lee, Han Lim;Park, Dong-Hoon;Lee, Moon-Que
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.206-209
    • /
    • 2016
  • This letter proposes a reconfigurable directional coupler that uses a variable impedance mismatch reflector to achieve high isolation characteristics in the antenna front end. The reconfigurable coupler consists of a directional coupler and a single-pole four-throw (SP4T) switch with different load impedances as a variable load mismatch reflector. Selection of the load impedance by the reflector allows cancellation of the reflected signal due to antenna load mismatch and the leakage from the input to isolation port of the directional coupler, resulting in high isolation characteristics. The performance of the proposed architecture in separating the received (Rx) signal from the transmitted (Tx) signal in the antenna front end was verified by implementing and testing the reconfigurable coupler at 917 MHz for UHF radio-frequency identification (RFID) applications. The proposed reconfigurable directional coupler showed an improvement in the isolation characteristics of more than 20 dB at the operation frequency band.

A Study on the Parameter Adaptive Current Controlled PWM Inverter for AC Drives. (교류전동기를 위한 Parameter Adaptive Control 방식의 PWM 인버터에 관한 연구)

  • 황영문;안진우
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.4
    • /
    • pp.259-266
    • /
    • 1987
  • In order to drive motor control system precisely, the motor is to be controlled by mmfs and current with sinusoidal waveforms. In this paper the Delta Modulation (DM) Technique is used for generating PWM pulse with sinusoidal waveform. However the motor currents yet contain odd harmonics due to leakage inductances, speed and exitation. To reduce harmonics, the parameter adaptive control method is introduced. That is, Req.C parameter of Delta Modulator is controlled adaptively by parameter adaptor. The adaptive signal is achieved by the difference between motor current and reference waveform, and this signal is converted to the voltage commend signal by adaptive mechanism. The test reslts show that this system is operated smoothly over a wide range of motor speed and motor current is controlled to be sinusoidal waveform adaptively.

  • PDF

Transmitter Beamforming and Artificial Noise with Delayed Feedback: Secrecy Rate and Power Allocation

  • Yang, Yunchuan;Wang, Wenbo;Zhao, Hui;Zhao, Long
    • Journal of Communications and Networks
    • /
    • v.14 no.4
    • /
    • pp.374-384
    • /
    • 2012
  • Utilizing artificial noise (AN) is a good means to guarantee security against eavesdropping in a multi-inputmulti-output system, where the AN is designed to lie in the null space of the legitimate receiver's channel direction information (CDI). However, imperfect CDI will lead to noise leakage at the legitimate receiver and cause significant loss in the achievable secrecy rate. In this paper, we consider a delayed feedback system, and investigate the impact of delayed CDI on security by using a transmit beamforming and AN scheme. By exploiting the Gauss-Markov fading spectrum to model the feedback delay, we derive a closed-form expression of the upper bound on the secrecy rate loss, where $N_t$ = 2. For a moderate number of antennas where $N_t$ > 2, two special cases, based on the first-order statistics of the noise leakage and large number theory, are explored to approximate the respective upper bounds. In addition, to maintain a constant signal-to-interferenceplus-noise ratio degradation, we analyze the corresponding delay constraint. Furthermore, based on the obtained closed-form expression of the lower bound on the achievable secrecy rate, we investigate an optimal power allocation strategy between the information signal and the AN. The analytical and numerical results obtained based on first-order statistics can be regarded as a good approximation of the capacity that can be achieved at the legitimate receiver with a certain number of antennas, $N_t$. In addition, for a given delay, we show that optimal power allocation is not sensitive to the number of antennas in a high signal-to-noise ratio regime. The simulation results further indicate that the achievable secrecy rate with optimal power allocation can be improved significantly as compared to that with fixed power allocation. In addition, as the delay increases, the ratio of power allocated to the AN should be decreased to reduce the secrecy rate degradation.

A Signal Subspace Interference Alignment Scheme with Sum Rate Maximization and Altruistic-Egoistic Bayesian Gaming

  • Peng, Shixin;Liu, Yingzhuang;Chen, Hua;Kong, Zhengmin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.6
    • /
    • pp.1926-1945
    • /
    • 2014
  • In this paper, we propose a distributed signal subspace interference alignment algorithm for single beam K-user ($3K{\geq}$) MIMO interference channel based on sum rate maximization and game theory. A framework of game theory is provided to study relationship between interference signal subspace and altruistic-egoistic bayesian game cost function. We demonstrate that the asymptotic interference alignment under proposed scheme can be realized through a numerical algorithm using local channel state information at transmitters and receivers. Simulation results show that the proposed scheme can achieve the total degrees of freedom that is equivalent to the Cadambe-Jafar interference alignment algorithms with perfect channel state information. Furthermore, proposed scheme can effectively minimize leakage interference in desired signal subspace at each receiver and obtain a moderate average sum rate performance compared with several existing interference alignment schemes.

Study on Analysis and Reconstruction of Leaked Signal from USB Keyboards (USB 키보드 누설신호 분석 및 복원에 관한 연구)

  • Choi, Hyo-Joon;Lee, Ho Seong;Sim, Kyuhong;Oh, Seungsub;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.11
    • /
    • pp.1004-1011
    • /
    • 2016
  • In this paper, we suggested the methodology of analyzing and reconstructing of measured electromagnetic emanations from the Micro Controller Unit(MCU) chip of Universal Serial Bus(USB) keyboard. By analyzing electromagnetic emanations, entered information is found at keystroke and furthermore, information security problems such as personal information leakage and eavesdropping can be arisen. USB keyboards make the radiated signal according to the signal transmission mechanism. Electromagnetic emanations were measured by log periodic antenna and wideband receiver and were analyzed by signal processing algorithm.

Development of Intelligent Pig for Detecting Corrosion on Pipeline Using MFL Technology (MFL 기술을 이용한 천연가스 배관 부식 검사용 인텔리전트 피그 개발)

  • Cho, S.H.;Kim, Y.K.;Park, D.J.;Yoo, H.R.;Koo, S.J.;Park, S.S.;Kim, D.K.;Rho, Y.W.
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.235-240
    • /
    • 2001
  • This paper introduces developed prototype intelligent pig which detects corrosion on pipeline by using Magnetic Flux Leakage technology. The 8 inch developed MFL(Magnetic Flux Leakage) pig is composed of 5 yokes which magnetize pipeline wall and 45 Hall sensors which detect MFL signal. The designed MFL modules are analyzed by using magnetic circuit method in order to confirm whether pipeline wall is fully saturated. A variety of artificial defects are manufactured on 8 inch diameter steel pipeline in order to acquire MFL signals. So leakage flux of the axial, radial and circumferential component was acquired as defects. The results of this paper show that design technique for 8 inch MFL pig can be applied to large diameter MFL pig and 0.5mm defect depth can be detected.

  • PDF

Implementation of High Magnetization System for Performance Enhancement of Magnetic Flux Leakage Tool

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Kim, Dong-Ku;Park, Dae-Jin;Rho, Yong-Woo;Seo, Kang;Park, Gwan-Soo;Choi, Doo-Hyun;Song, Sung-Jin
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.199-203
    • /
    • 2010
  • This paper discusses the effectiveness of high magnetization saturation in ILI (In-Line Inspection) using an MFL (Magnetic Flux Leakage) tool, and introduces a practical method for improving the magnetization level together with the piggability. Thin steel plates, replacing the conventional wire brushes were used as conductors to transfer the magnetic flux to the pipe wall. The newly designed MFL tool was compared with the conventional version by means of FEM (Finite Element Method) analysis and full-scale experiments. In the results, the newly developed magnetization system obtained a stronger MFL signal amplitude, specially 2.7 times stronger, than that obtained by the conventional magnetization system for the same defect dimensions.

Development of Lightning Arrester Degradation Monitoring System Using ZCT (ZCT틀 이용한 피뢰기 열화 감시 시스템 개발)

  • Park, J.N.;Lee, Y.H.;Jang, S.H.;Kim, P.S.;Shin, Y.S.;Kim, Y.G.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1626-1628
    • /
    • 2003
  • The lightning arrester is a very important overvoltage protection device in the electric power system. Therefore, the inspection of lightning arrester whether it keeps its performance or not properly has close related to verifying the safety confidence of the electric power system. But the development of the deterioration measuring method and on-line detecting system, is necessary to monitor the deterioration of the lightening arrestor. In this paper, we developed the lightning arrester degradation monitoring system. This system detected leakage current of lightning arrester by using the ZCT, and analyze the third harmonics ingredient of leakage current using DFT method in the Data Acquisition Unit(DAU). The analyzed current signal is transmit to the Human-Machine Interface(HMI), and HMI alarmed when accident are occurred and informed with the amplitude of leakage current to the operator.

  • PDF

A Study of Stator Fault Detection for the Induction Motor Using Axial Magnetic Leakage Flux (축방향 누설자속 측정에 의한 유도전동기의 고정자 결함검출에 관한 연구)

  • Shin, Dae-Cheul;Kim, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.131-137
    • /
    • 2005
  • The purpose of this paper is to evaluate the axial magnetic flux measurement could be used as a tool of the condition monitoring system for the induction motor and to develope the diagnostic algerian for the electric motors. The magnetic leakage flux signal is captured by the flux coil located at the end of motor without the disturbance of the operation. And the signal is analyzed both time and frequency bases to detect the failure of the motor. Specific signature can be described in time and frequency domain for each faults of the motor. The spectrum of the signal was found more useful for the monitoring purpose. The supply voltage imbalance and tin to turn failure of the stator winding could be detected by analysing the specific sidebands of the axial flux and sideband of the rotor bar pass frequency with the high resolution spectrum. The goal of this study verity that the axial flux measurement for the induction motor is a powerful tool for the diagnostic method and develope the algorithm to detect the fault.

A Study on a Improvement of the Speech Quality by Spectrum Analysis with Variable Window in CELP Vocoder (가변 윈도우 스펙트럼 분석을 이용한 CELP 부호화기의 음질 향상에 관한 연구)

  • 나덕수;민소연;배명진
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.106-109
    • /
    • 2000
  • There have been proposed two types of low bit rate vocoder upto now : One is MBE type using the spectrum modeling and another is CELP type using the hybrid coding method. CELP type vocoder has mainly studied between them. Specially, much of intensity is concentrated in CELP vocoder due to the emergence of Internet Phone and PCS in a domestic. In order to improve the speech quality in CELP vocoder, in this paper, we proposed a new spectrum analysis algorithm with variable window, In CELP vocoder, the spectrum of the synthesised speech signal is distorted because the fixed size windows is used for spectrum analysis. So we have measured the spectral leakage and in order to minimize the spectral leakage have adjusted the window size. Applying this method G.723.1 ACELP, we can get SD(Spectral Distortion) reduction 0.084(dB), residual energy reduction 6.3% and MOS(Mean Opinion Score) improvement 0.1.

  • PDF