• Title/Summary/Keyword: Leakage scenarios

Search Result 83, Processing Time 0.028 seconds

Power Analysis Attacks on Blinding Countermeasure against Horizontal CPA (수평적 상관관계 분석에 안전한 블라인딩 대응기법에 대한 전력 분석 공격)

  • Lee, Sangyub;Kim, Taewon;Kim, HeeSeok;Hong, Seokhie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.4
    • /
    • pp.727-738
    • /
    • 2015
  • Until recently, power analysis is one of the most popular research issues among various side channel analyses. Since Differential Power Analysis had been first proposed by Kocher et al., various practical power analyses correspond with software/hardware cryptographic devices have been proposed. In this paper, we analyze vulnerability of countermeasure against power analysis exploiting single power trace of public cryptographic algorithm. In ICICS 2010, Clavier et al. proposed Horizontal Correlation Analysis which can recover secret information from a single exponentiation trace and corresponding countermeasures. "Blind operands in LIM", one of their countermeasures, exploits additive blinding in order to prevent leakage of intermediate value related to secret information. However, this countermeasure has vulnerability of having power leakage that is dependant with the message known by an adversary. In this paper, we analyzed vulnerabilities by three attack scenarios and proved them by practical correlation power analysis experiments.

Emission regulation and the carbon leakage: the impact of the consumption based carbon accounting and the border adjustment measure (배출규제가 탄소누출에 미치는 영향 분석 및 전망: 소비 관점의 탄소회계와 국경조치의 영향을 중심으로)

  • Oh, Inha
    • Environmental and Resource Economics Review
    • /
    • v.21 no.4
    • /
    • pp.851-891
    • /
    • 2012
  • The objective of this study can be presented as follows: First, given the consumption-based carbon accounting method which has now been claimed, this study reviews the emissions within Korea and the resulting position change in international society. Second, when each nation makes efforts to reduce carbon emissions under the Copenhagen Accord, this study, using the Computable General Equilibrium (CGE) model, reviews the resulting carbon leakage and analyzes the effect from the various border adjustment measures. However, reflecting uncertainties in the negotiation processes, this study attempts to apply scenarios with regards to the reduction-mandatory nation group. In addition, this study tries to observe the impact on Korea through testing the various border adjustment measures, including the free allocation and embodied carbon tariffs.

  • PDF

A Study on Classification of Explosion Hazardous Area for Facilities using Lighter-than-Air Gases (공기보다 가벼운 가스 사용시설의 폭발위험장소 설정방안에 대한 연구)

  • Yim, Ji-Pyo;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • There have been controversies over whether explosion hazardous area(EHA) should be classified for facilities which use lighter-than-air gases such as city gas, hydrogen and ammonia. Two view points are confronting each other: an economic piont of view that these gases are lighter than air and disperse rapidly, hence do not form EHA upon release into the atmosphere, and a safety point of view that they are also inflammable gases, hence can form EHA although the extent is limited compared to heavy gases. But various standards such as KS, IEC, API, NFPA do not exclude light gases when classifying EHA and present examples of EHA for light gas facilities. This study calculates EHA using the hypothetical volume in the IEC code where the hole sizes required for the calculation were selected according to various nominal pipe sizes in such a way to conform to the EHA data in the API code and HSL. Then, 25 leakage scenarios were suggested for 5 different pipe sizes and 5 operating pressures that cover typical operating conditions of light gas facilities. The EHA for the minimum leakage scenario(25 mm pipe, 0.01MPa pressure) was found to correspond to a hypothetical volume larger than 0.1 $m^3$(medium-level ventilation). This confirms the validity of classifying EHA for facilities using lighter-than-air gases. Finally, a computer program called HACPL was developed for easy use by light gas facilities that classifies EHA according to operating pressures and pipe sizes.

Development Plan of Accident Scenario Modeling Based on Seasonal Weather Conditions - Focus on Chlorine Leakage Accident - (계절별 기상조건에 따른 사고시나리오 모델링 발전방안 - 염소 누출사고를 중심으로 -)

  • Kim, Hyun-Sub;Jeon, Byeong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.733-738
    • /
    • 2017
  • In this study, we selected chlorine, a typical toxic material used in many workplaces, as the leakage material, and through the analysis of alternative scenarios based on the meteorological conditions in the summer frequently encountered in accidents, we suggest ways to improve the (method of analysis/accident scenario modeling). The analysis of 296 chemical accidents from January 2014 to December 2016 found that the highest rate of occurrence was in summer, accounting for 35.81% of the total. According to the risk assessment, the influence range and number of inhabitants in the influence area were 712.4 m and 20,090 under the annual mean weather conditions and 796.2 m and 27,143 people under the summer mean weather conditions, respectively. This result implies that, under certain conditions, the range of impacts in the current alternative scenario is incomplete. Therefore, risk assessment systems need to be improved in order to take into consideration the characteristics of each chemical substance.

Optimization of Data Placement using Principal Component Analysis based Pareto-optimal method for Multi-Cloud Storage Environment

  • Latha, V.L. Padma;Reddy, N. Sudhakar;Babu, A. Suresh
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.12
    • /
    • pp.248-256
    • /
    • 2021
  • Now that we're in the big data era, data has taken on a new significance as the storage capacity has exploded from trillion bytes to petabytes at breakneck pace. As the use of cloud computing expands and becomes more commonly accepted, several businesses and institutions are opting to store their requests and data there. Cloud storage's concept of a nearly infinite storage resource pool makes data storage and access scalable and readily available. The majority of them, on the other hand, favour a single cloud because of the simplicity and inexpensive storage costs it offers in the near run. Cloud-based data storage, on the other hand, has concerns such as vendor lock-in, privacy leakage and unavailability. With geographically dispersed cloud storage providers, multicloud storage can alleviate these dangers. One of the key challenges in this storage system is to arrange user data in a cost-effective and high-availability manner. A multicloud storage architecture is given in this study. Next, a multi-objective optimization problem is defined to minimise total costs and maximise data availability at the same time, which can be solved using a technique based on the non-dominated sorting genetic algorithm II (NSGA-II) and obtain a set of non-dominated solutions known as the Pareto-optimal set.. When consumers can't pick from the Pareto-optimal set directly, a method based on Principal Component Analysis (PCA) is presented to find the best answer. To sum it all up, thorough tests based on a variety of real-world cloud storage scenarios have proven that the proposed method performs as expected.

Endoscopic Intervention for Anastomotic Leakage After Gastrectomy

  • Ji Yoon Kim;Hyunsoo Chung
    • Journal of Gastric Cancer
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2024
  • Anastomotic leaks and fistulas are significant complications of gastric surgery that potentially lead to increased postoperative morbidity and mortality. Surgical intervention is reserved for cases with severe symptoms or hemodynamic instability; however, surgery carries a higher risk of complications. With advancements in endoscopic treatment options, endoscopic approaches have emerged as the primary choice for managing these complications. Endoscopic clipping is a traditional method comprising 2 main categories: through-the-scope clips and over-the-scope clips. Through-the-scope clips are user friendly and adaptable to various clinical scenarios, whereas over-the-scope clips can close larger defects. Another promising approach is endoscopic stent insertion, which has shown a high success rate for leak closure, although vigilant monitoring is required to monitor stent migration. Infection control is essential in post-surgical leakage cases, and endoscopic internal drainage provides a relatively safe and noninvasive means to manage fluids, contributing to infection control and wound healing promotion. Endoscopic suturing offers full-thickness wound closure, but requires additional training and endoscopic versatility. As a promising tool, endoscopic vacuum therapy potentially surpasses stent therapy by draining inflammatory materials and closing defects. Furthermore, the use of tissue sealants, such as fibrin glue and cyanoacrylate, has been reported to be effective in selected situations. The choice of endoscopic device should be tailored to individual cases and specific patient conditions, with careful consideration of the nature of the defect. Further extensive studies involving larger patient populations are required to provide more robust evidence on the efficacy of endoscopic approach in managing post-gastric anastomotic leaks.

Mobile Sensor Velocity Optimization for Chemical Detection and Response in Chemical Plant Fence Monitoring (사업장의 경계면에서 화학물질 감지 및 대응을 위한 이동식 센서 배치 최적화)

  • Park, Myeongnam;Kim, Hyunseung;Cho, Jaehoon;Lulu, Addis;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.2
    • /
    • pp.41-49
    • /
    • 2017
  • Recently, as the number of facilities using chemicals is increasing, the amount of handling is rapidly increasing. However, chemical spills are occurring steadily, and if large quantities of chemicals are leaked in time, they are likely to cause major damage. These industrial complexes use information obtained from a number of sensors to detect and monitor leaking areas, and are used in industrial fields by applying existing fixed sensors to robots and drones. Therefore, it is necessary to propose a sensor placement method at the interface for rapid detection and response based on various leaking scenarios reflecting leaking conditions and environmental conditions of the chemical handling process. In this study, COMSOL was used to analyze the actual accident scenarios by applying the medium parameter to the case of chemical leaks. Based on the accident scenarios, the objective function is selected so that the velocity of each robot is calculated by attaching importance to each item of sensor detection probability, sensing time and sensing scenario number. We also confirmed the feasibility of this method of reliability analysis for unexpected leak accidents. Based on the above results, it is expected that it will be helpful to trace back the leakage source based on the concentration data of the portable sensor to be applied later.

A 23.52µW / 0.7V Multi-stage Flip-flop Architecture Steered by a LECTOR-based Gated Clock

  • Bhattacharjee, Pritam;Majumder, Alak;Nath, Bipasha
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.3
    • /
    • pp.220-227
    • /
    • 2017
  • Technology development is leading to the invention of more sophisticated electronics appliances that require long battery life. Therefore, saving power is a major concern in current-day scenarios. A notable source of power dissipation in sequential structures of integrated circuits is due to the continuous switching of high-frequency clock signals, which do not carry any information, and hence, their switching is eliminated by a method called clock gating. In this paper, we have incorporated a recent clock-gating style named Leakage Control Transistor (LECTOR)-based clock gating to drive a multi-stage sequential architectures, and we focus on its performance under three different process corners (fast-fast, slow-slow, typical-typical) through Monte Carlo simulation at 18 GHz clock with 90 nm technology. This gating is found to be one of the best gated approaches for multi-stage architectures in terms of total power consumption.

Validity Review on Classification of Explosion Hazardous Area using Hypothetic Volume (가상체적을 이용한 폭발위험장소 구분의 타당성 검토)

  • Yim, Ji-Pyo;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.68-75
    • /
    • 2014
  • It is very important to classify explosion hazardous area (EHA) suitably and to use proper explosion-proof electric installations for facilities using flammable gases and liquids. In the past, various examples in the Notification of Ministry of Employment and Labor were referred to in classifying EHA. But, at present, many companies use the hypothetical volume in Korean Standards (KS). This study reviews the validity of EHA classification based on the hypothetical volume by comparing the calculated radii of EHA with those obtained by a consequence analysis program called PHAST and a mathematical approach in British Standards (BS). The radii of EHA by the hypothetical volume were found to be slightly larger than those by the other two methods. This was attributed to rather conservative uses of a safety factor(k) and a correction factor(f) for availability of ventilation in calculating the hypothetical volume. Since the differences are not so conspicuous, however, it is concluded that the hypothetical volume in KS is a valid means for the classification of EHA. This study also presents a table of the radii of EHA for easy reference by small-scale companies using city gas, C3-LPG and flammable liquid(toluene), respectively. The table consists of 25 leakage scenarios corresponding to combinations of 5 pipe(nozzle) sizes and 5 operating conditions for each flammable gas and liquid.

CFD Approach on Gas Explosion for SIL in Gas Fuelled Ship

  • Kim, Ki-Pyoung;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.2
    • /
    • pp.195-200
    • /
    • 2015
  • It is envisaged that the effect of increasingly stricter air emissions legislation implemented through IMO Annex VI and other local air quality controls, together with favorable financial conditions for the use of natural gas instead of liquid fuel oil as a bunker fuel, will see an increasing number of DF engine and single gas fuel engine applications to LNG carriers and other vessel types. As part of provision for the current international movements in the shipping industry to reduce GHG emission in air, new design concepts using natural gas as an alternative fuel source for propulsion of large commercial vessels, have been developed by shipyards and research institutes. In this study, an explosion analysis for a gas supply machinery room of LNG-fuelled container ship is presented. The gas fuel concept is employed for the high pressure ME-GI where a leakage in the natural gas double supply pipe to the engines is the subject of the present analysis. The consequences of a leak are simulated with computational fluid dynamics (CFD) tools to predict typical leak scenarios, gas cloud sizes and possible explosion pressures. In addition, capacity of the structure which is subject to explosion loads has been assessed.