• Title/Summary/Keyword: Leakage safety

Search Result 836, Processing Time 0.035 seconds

Technical Criterion of Safety Evaluation of Leakage Preventing Plates for Alleviating Space Shortage Between Chemical Storage Tank and Dike (화학물질 저장 탱크와 방류벽 사이의 공간 부족 개선을 위한 누출 방지판의 안정성 평가 기준)

  • Lee, Eunbyul;Kwak, Sollim;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.42-50
    • /
    • 2018
  • The Chemical Controls Act strictly regulates for the chemical companies to establish sufficient space between the liquid chemical tank and dike, but facilities already installed suffer from the space shortage between the tank and dike. Installing leakage preventing plates on the dike is considered as one of the economic solutions that can alleviate the space deficiency. However, there is no technical and reasonable criterion for the safety evaluation of the leakage preventing plate on the dike. In order to address this problem, we provide generalized and verified calculating equations that give maximum height and horizontal distance of leakage trajectories. Through the proposed equations, proper heights of the leakage preventing plates on the dike can be easily determined. In this study, new calculating methods are also developed to determine the impact force of the liquid to the leakage preventing plates. In addition, we performed the reactivity experiments between four corrosive liquid chemicals and two stainless steel materials that are candidate substances for the construction of the leakage preventing plate. The results of this study is expected to be applicable as a guideline in the design of safe dike and its leakage preventing plates.

Study of Hydrogen Bus Operational Safety Monitoring Method through Driving Data Analysis (주행 데이터 분석을 통한 수소버스 운행안전 모니터링 기법 연구)

  • Hyunmi Lee;Insik Lee;Yongju Yi;Jeong-Ah Jang;Siwoo Kim;Sojung Sim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.4
    • /
    • pp.58-64
    • /
    • 2023
  • The adoption of hydrogen-powered Elec is expanding globally. Hydrogen is recognized as a potentially hazardous energy source, and safety assessment is crucial for the development of plans to supply hydrogen-powered electric buses. Hydrogen gas leakage can have a significant impact during bus operations, and continuous hydrogen leakage in hydrogen-powered vehicles can result in fatal accidents. In this study, information about hydrogen leakage is collected through sensors installed within the vehicles and is measured when the sensor detects a leak. The study also proposes the use of Pseudo Fuel Leakage (PFL, %) as an additional indicator for evaluating and monitoring hydrogen safety and leakage.

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

Analysis of Characteristic for Electric Leakage Component at Stable Size (축사 규모별 누전성분 특성 분석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.54-58
    • /
    • 2012
  • This paper is purposed to analyze electric leakage component which can prevent electrical fires on breaker capacity expansion and power failure by operation of ELB(Earth leakage breaker) for stable sizes. In order to analysis for electric leakage component for stable sizes, this paper studied field state investigation which are at stable companies( 10 companies) in cheong-won location to deduce the problems of electric leakage component is analyzed. The field state experiment method is measured with electric leakage component which load part of ELB detected by electric loads(electrical fan, lighting, auto waterer, feeder and halogen lighting) and stable sizes. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in stable.

A Study on Characteristics of Hydrogen Leakage in Hydrogen Town Governor Room (수소타운 정압기실 내 수소 누출 특성 연구)

  • NAM, TAE-HO;KIM, DONG-HWAN;LEE, JUNG-WOON;LEE, SEUNG-KUK;LEE, YEON-JAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.685-692
    • /
    • 2016
  • Hydrogen will be a future eco-friendly energy source that can replace current fossil fuels However when hydrogen gas leaks and people inhale a lot of hydrogen gases, they can have fatal effects fell into comas. Therefore, we need to develop a safety technology and related guidelines for reducing risks of hydrogen leakage. In this regard, we carried out demonstration tests assuming a situation of hydrogen leakage. Before the experiments, we analyze the standards for governor facilities to check vent positions and sensor positions. Then, we select four types of ventilation structures and proceeds with the experiments of hydrogen leakage at 1 LPM and 1.5 LPM. Based on the experimental results, we propose the direction on optimization of vent positions and sensor positions in the hydrogen leakage situation.

Analysis of Resistive and Capacitive Leakage Current according to Wiring Type and Length at Cattle Barn (우사(牛舍)에서 전기배선의 종류와 길이에 따른 저항성 및 용량성 누전전류 분석)

  • Yoo, Sang-Ok;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.34-39
    • /
    • 2014
  • This paper is aimed to prevent danger of electrical fire at cattle barn to detect resistive and capacitive leakage current component for wiring type and length. In order to analysis for electric leakage component for cattle barn sizes and normal buildings, this paper was studied field state investigation which are at cattle barn companies(10 companies) in Cheong-won location and normal buildings at Nam-bu market in Jeon-ju location. Market to deduce the problems of electric leakage component is analyzed. The resistive and capacitive leakage current component for wiring type and length is analyzed at Beon-young cattle barn. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in cattle barn. It is acceptable for electrical equipment use in an cattle barn.

Investigation of the Occurrence of Industrial Accidents and Accidental Deaths by Chemical Leakage and Skin Contact (화학물질의 누출과 피부접촉에 의한 재해자 및 사고사망자 발생현황 조사)

  • Lee, Kwon Seob;Choi, Hyun Sung;Lee, Ha Young;Shin, Kyung Min;Choi, Heung Koo;Lee, In Seop
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.39-49
    • /
    • 2020
  • Objectives: We investigated the status of accidents and deaths caused by chemical leakage and skin contact in Korea. The purpose of this study was to produce and provide technical reference data for the efficient management of accidents and the rational management of accidental chemicals. Methods: Accidents and deaths caused by chemical leakage and skin contact in industry were investigated. Based on 68 accident reports related to chemical leakage and skin contact, the causes of accidental deaths were analyzed. In addition, we investigated the chemical substances and articles that caused these accidents and deaths. Based on the results of the investigation, the causes of accidents caused by chemical leakage and skin contact were identified and practical management measures for the chemicals were suggested. Results and Conclusions: In 2018, 372 people suffered from chemical leaks and skin contact, up by 123 (about 49.4%) from the previous year. The number of accident deaths was 14, an increase of five (about 55.6%) from the previous year. In the last three years (2016-2018), 91 chemical substances and article groups were involved in accidents caused by chemical leakage and skin contact. There were 16 chemical substance and article groups involved in accidental deaths. There were ten cases of accidents involving two or more casualties due to chemical leakage and skin contact, and 23 deaths occurred. Most of these accidental deaths were caused by subcontractor workers outsourcing risks. Therefore, there is an apparent need to strengthen the responsibility for safety and health among subcontractors.

DC Leakage Current Properties Analysis of the LED Lamps of Road and Landscape Lighting (LED 가로등 및 경관조명의 직류 누전 특성 분석)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.885-891
    • /
    • 2011
  • In this paper, we studied dc leakage current properties analysis of LED lamps of road and landscape lighting when leakage current appeared in dc power line. Generally, converter of LED lighting is divides to insulated type and non-insulated type according to components. When electric leakage happened in AC power line, earth leakage breaker(ELB) senses leakage current and interrupts electric circuit. In dc power source, We need experimental verification about dc electric leakage for electricity safety. In normal wiring conditions and in the water, in case of using insulated type of converter, dc leakage current did not occur. However, in case of using non-insulated type of converter, dc leakage current occurred and passed through into the ground. We found that there is a hazard of electric shock by dc leakage current. We expect that the results of these studies would be helpful for electrical safety of LED lamps for road and landscape lighting.

Development and Performance Test of Online Electrical Safety Monitoring System Applying an Algorithm to Measure Resistive Leakage Currents using Phase Differences (위상차를 이용한 저항성 누설전류 측정 알고리즘을 적용한 온라인 전기안전 감시시스템의 개발 및 성능시험)

  • Yoo, Jeong Hyun;Kim, Hie Sik;Jeong, Yong Wook
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.27-32
    • /
    • 2018
  • Nowadays, to prevent electrical accidents in Korea, inspectors directly performed checking general electrical facilities as a cycle from every one to three years. It is difficult to presuppose an omen because intact conditions of electrical equipments are not kept at the time of inspection. In this paper, in order to ensure effectiveness of an online basis electric inspection, we developed an electrical safety IoT system using LoRa communication technology to enable monitoring mainly electrical safety components such as overcurrent, overvoltage, resistive leakage current, and power. Then we proposed a method for verifying performances of the prosed electrical safety IoT system. Resistive leakage currents are calculated by using difference of phase between voltages and currents. We verified that average errors are 0.97%, which reference goal is ${\pm}5%$ for a device, through reliability test according to conditions. Results of this research can be used as basic study materials to develop technologies for measuring three phase leakage current and for implementing public electrical safety. platform.

A Study on the Characteristics of Electric Shock in Water due to the Leakage of Submerged Electric Facility (침수된 전기설비의 누전으로 인한 수중에서의 감전특성에 관한 연구)

  • 김두현;강동규
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.61-65
    • /
    • 2002
  • A study on the characteristics of electric shock in fresh water due to the leakage of submerged electric facility is conducted by using a reduced scale model at a scale of 1:10 in laboratory. Electric potential as a function of distance from leakage source, type of the leakage source, magnitude of the source voltage, submerged depth and diameter of a copper rod electrode is measured. On the basis of safety standard, separation for guarantee of safety is determined by the measured potential. Also supposing that body resistance is 500[$\Omega$], the human reaction was estimated by calculating body current for some shock duration. Thus, in this paper, the hazard of the electric shock is assessed by introducing representative safety factors, body voltage and body current due to leakage source.