• Title/Summary/Keyword: Leakage reduction

Search Result 479, Processing Time 0.023 seconds

Leakage Analysis of Angled-Labyrinth-Packing-Ring Seal for Steam Turbine Using CFD (CFD를 사용한 스팀터빈용 각이 진 패킹 링 실의 누설량 예측)

  • Ha, Tae-Woong;Kang, Jung-Hyun
    • Tribology and Lubricants
    • /
    • v.25 no.5
    • /
    • pp.298-304
    • /
    • 2009
  • An angled labyrinth seal is used for the diaphragm-packing-ring seal design of steam turbine due to its leakage reduction characteristic. CFD analysis using FLUENT has been performed to predict leakage and determine an optimum slanted angle which yields the best leakage reduction. Results show that the optimum value of slanted angle is $-30^{\circ}$ independent of number of labyrinth teeth, inlet pressure, and tooth height to pitch ratio. 3D CFD analysis has been performed for predicting leakage of the angled labyrinth seal. Comparing with the result of 2D CFD analysis, 3D CFD analysis shows 1.4% smaller.

Search Method for Optimal Valve Setting and Location to Reduce Leakage in Water Distribution Networks (배수관망시스템 누수저감을 위한 최적 밸브제어 및 위치탐색 모델 개발)

  • Choi, Jong Sub;Kala, Vairavamoorthy;Ahn, Hyo Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.149-157
    • /
    • 2008
  • The reduction of leakage is a major issue of the South Korea water industry. The inclusion of pressure dependent leakage terms in network analysis allows the application of optimization techniques to identify the most effective means of reducing water leakage in distribution networks. This paper proposes a method to find optimal setting and location of control valve for reducing leakage efficiently. The proposed search method differs from previous methods for addressing optimal valve location problem and improves the GA simulation time with guaranteeing for getting the global optimal solution. The strength of this method has been demonstrated by means of case studies. This allows the procedure of optimization to be more robust and computational efficient.

Leakage Characteristic of Angled-Circumferential-Groove-Pump Seal with CFD Analysis (각이 진 평행 홈 펌프 실의 누설량 특성 해석)

  • Choi, Bok-Sung;Ha, Tae-Woong
    • Tribology and Lubricants
    • /
    • v.25 no.2
    • /
    • pp.96-101
    • /
    • 2009
  • In order to improve leakage characteristic, angled-circumferential-groove pump seal is suggested. CFD analysis using FLUENT has been performed to predict leakage and determine an optimum slanted-groove angle $\alpha$ which yields the best leakage reduction. The optimum value of $\alpha$ ranges from $45^{\circ}$ to $60^{\circ}$ and depends on the pressure difference of seal and number of grooves for the same groove geometry. The maximum leakage reduction ratio increases as increasing the pressure difference of angled-circumferential-groove pump seal with the optimum value of $\alpha$.

Leakage Analysis and Design Modification of the Combination-Type-Staggered-Labyrinth Seal (누설량 저감을 위한 래버린스 실의 설계개선 및 해석)

  • Ha, Tae-Woong
    • Tribology and Lubricants
    • /
    • v.23 no.2
    • /
    • pp.43-48
    • /
    • 2007
  • Leakage reduction through annular type labyrinth seals of steam turbine is necessary for enhancing their efficiency. In this study, modified geometry of the original combination-type-staggered-labyrinth seal has been suggested and numerical analysis for leakage prediction has been carried out for the modified-combination-type-staggered-labyrinth seal both based on bulk-flow model and using the CFD code FLUENT. The theoretical analysis based on bulk-flow model yields leakage reduction of the modified combination type staggered labyrinth seal by about 11%. Comparing with the result of Bulk-flow model analysis, the leakage result of CFD analysis shows reasonable agreement within 9.8% error.

A Study on Setting Methods of Economic Level of Leakage in Water Pipe Networks (상수도 관망에서의 경제적인 누수관리목표 산정 방안 연구)

  • Hwang, Jinsoo;Choi, Taeho;Lee, Doojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.237-248
    • /
    • 2017
  • The estimation method of economical leakage management target utilized upon planning business for improvement of revenue water ratio in South Korea is presented and applicability of methods developed in this study is assessed through application on site. With a consideration of revenue water ratio in application target area, estimation method of long-term economical leakage management target is applied. Three leakage reduction methods such as replacement of residual aged pipe, leakage investigation and restoration and water pressure management are applied with a consideration of characteristics of site. Due to difficulty of obtaining data, analysis of cost/benefit by leakage reduction methods is performed by applying method of leakages estimation equation among statistical methods. As a result of application, revenue water ratio corresponding to long-term economical leakage management target is 91.6 %.

Sub-1.2-V 1-Gb Mobile DRAM with Ultra-low Leakage Current (극저 누설전류를 가지는 1.2V 모바일 DRAM)

  • Park, Sang-Kyun;Seo, Dong-Il;Jun, Young-Hyun;Kong, Bai-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.433-434
    • /
    • 2007
  • This paper describes a low-voltage dynamic random-access memory (DRAM) focusing on subthreshold leakage reduction during self-refresh (sleep) mode. By sharing a power switch, multiple iterative circuits such as row and column decoders have a significantly reduced subthreshold leakage current. To reduce the leakage current of complex logic gates, dual channel length scheme and input vector control method are used. Because all node voltages during the standby mode are deterministic, zigzag super-cutoff CMOS is used, allowing to Preserve internal data. MTCMOS technique Is also used in the circuits having no need to preserve internal data. Sub-1.2-V 1-Gb mobile DDR DRAM employing all these low-power techniques was designed in a 60 nm CMOS technology and achieved over 77% reduction of overall leakage current during the self-refresh mode.

  • PDF

Leakage Current Reduction by a New Combination of PWM Method and Modified connection for 3-level Inverter Photovoltaic PCS (3상 3레벨 태양광 PCS에서 누설전류 저감 기법)

  • Seng, Chhaya;Jo, Jongmin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.346-347
    • /
    • 2020
  • This paper presents the two combination methods for leakage current reduction in photovoltaic system PCS. The leakage current in the photovoltaic system generated from the parasitic capacitance existing between the photovoltaic system and ground relevance to common mode voltage caused by PWM switching. Firstly, Leakage current reduced by a PWM method using two carriers with 180-degree phase different. Secondly, the leakage current is more reduced by connecting LCL filter to the mid-point of DC link. This combining method is revealed in PSIM simulation with 1 uF parasitic capacitance.

  • PDF

Estimation of background minimum night flows by metering water use in water distribution areas (야간사용량 측정을 통한 배급수구역 배경야간최소유량 산정)

  • Lee, Doo-Jin;Kim, Do-Hwan;Kim, Ju-Hwan;Kim, Kyoung-Pil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.495-508
    • /
    • 2010
  • The aim of this study is to develop a quantified water loss Index to evaluate and manage leakage scientifically for the reduction of non-revenue water in water distribution systems. For the purpose, unavoidable background leakage suggested from UK water industry and IWA, and allowable water leakage in accord with the concept of allowable water loss are proposed by analyzing the inflow into two study water districts and the short-term water use of each customer in the districts. The study distribution areas are selected among the metered districts with good maintenance of leakage after improvement activities in Nonsan, medium sized city in Korea. Estimation models of allowable leakage are developed by metering and analyzing the minimum night flow at residential and commercial areas in the city. In the results of the investigation, it is estimated that background night flow in residential area was larger than that of commercial area where the types of business shows small water use characteristics. Meanwhile, night flow and background water loss on internal plumbing systems show great differences for each district which is influenced much by the water use characteristics and facilities scale. Based on metering water use data in various districts, leakage management criteria can be established under the consideration of domestic conditions in Korea by analyzing separated real water use and background leakage and it is possible to apply into presentation of optimal leakage level and reasonable time for working activities for leakage reduction.

Effects of Carrier Leakage on Photoluminescence Properties of GaN-based Light-emitting Diodes at Room Temperature

  • Kim, Jongseok;Kim, Seungtaek;Kim, HyungTae;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.164-171
    • /
    • 2019
  • Photoluminescence (PL) properties of GaN-based light-emitting diodes (LEDs) were analyzed to study the effects of carrier leakage on the luminescence properties at room temperature. The electrical leakage and PL properties were compared for LEDs showing leakages at forward bias and an LED with an intentional leakage path formed by connecting a parallel resistance of various values. The leakages at the forward bias, which could be observed from the current-voltage characteristics, resulted in an increase in the excitation laser power density for the maximum PL efficiency (ratio of PL intensity to excitation power) as well as a reduction in the PL intensity. The effect of carrier leakages on PL properties was similar to the change in PL properties owing to a reduction of the photovoltage by a reverse current since the direction of the carrier movement under photoexcitation is identical to that of the reverse current. Valid relations between PL properties and electrical properties were observed as the PL properties deteriorated with an increase in the carrier leakage. The results imply that the PL properties of LED chips can be an indicator of the electrical properties of LEDs.

Electrical Leakage Levels Estimated from Luminescence and Photovoltaic Properties under Photoexcitation for GaN-based Light-emitting Diodes

  • Kim, Jongseok;Kim, HyungTae;Kim, Seungtaek;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.516-521
    • /
    • 2019
  • The electrical leakage levels of GaN-based light-emitting diodes (LEDs) containing leakage paths are estimated using photoluminescence (PL) and photovoltaic properties under photoexcitation conditions. The PL intensity and open-circuit voltage (VOC) decrease because of carrier leakages depending on photoexcitation conditions when compared with reference values for typical LED chips without leakage paths. Changes of photovoltage-photocurrent characteristics and PL intensity due to carrier leakage are employed to assess the leakage current levels of LEDs with leakage paths. The current corresponding to the reduced VOC of an LED with leakage from the photovoltaic curve of a reference LED without leakage is matched with the leakage current calculated using the PL intensity reduction ratio and short-circuit current of the LED with leakage. The current needed to increase the voltage for an LED with a leakage under photoexcitation from VOC of the LED up to VOC of a reference LED without a leakage is identical to the additional current needed for optical turn-on of the LED with a leakage. The leakage current level estimated using the PL and photovoltaic properties under photoexcitation is consistent with the leakage level measured from the voltage-current characteristic obtained under current injection conditions.