Leakage Magnetic Field Suppression Using Dual-Transmitter Topology in EV Wireless Charging

  • Zhu, Guodong;Gao, Dawei;Lin, Shulin
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.625-636
    • /
    • 2019
  • This paper proposes an active leakage magnetic field (LMF) suppression scheme, which uses the dual-transmitter (DT) topology, for EV wireless charging systems (EVWCS). The two transmitter coils are coplanar, concentric and driven by separate inverters. The LMF components generated by the three coils cancel each other out to reduce the total field strength. This paper gives a detailed theoretical analysis on the operating principles of the proposed scheme. Finite element analysis is used to simulate the LMF distribution patterns. Experimental results show that when there is no coil misalignment, 97% of the LMF strength can be suppressed in a 1kW prototype. These results also show that the impact on efficiency is small. The trade-off between LMF suppression and efficiency is revealed, and a control strategy to balance these two objectives is presented.

건축물에너지효율등급 기밀시험이 등급에 미치는 영향분석 (Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds)

  • 김대원;정광섭;김영일;남아리새;주정경
    • 에너지공학
    • /
    • 제23권1호
    • /
    • pp.40-45
    • /
    • 2014
  • 주거시설에서 환기횟수 0.7회 적용은 실내공기질 향상과 거주자의 쾌적성을 높이고자 100세대 이상은 의무적으로 적용하고 있다. 건축물에너지효율등급에서는 환기횟수를 기준으로한 기밀시험을 실시 하여 그결과 값을 효율등급결과치에 반영함으로서 창호주변의 정밀시공을 유도하고 침기로 인해 손실되는 에너지절감을 꾀하고 있다. 건축물엔지효율등급 현장실사 결과 환기횟수가 0.6~0.71까지 나타났으며 그차이가 에너지 절감량에 크게 영향을 미치는 것으로 나타났다. 유럽의 패시브 하우스 기준이 0.6회 이하의 기밀을 요구하고 있고 우리나라도 2017년 패시브하우스, 2025년 제로하우스를 목표로 하고 있어 비주거 건물의 기밀진단의 의무확대와 고기밀 건물에 대한 연구와 시공방법이 시급한 실정이다.

인접 채널 누설이 에너지 검파 기반 스펙트럼 센싱에 미치는 영향 (Effects of Adjacent Channel Leakage on an Energy Detection Based Spectrum Sensing)

  • 임창헌;김형중;김창주
    • 한국전자파학회논문지
    • /
    • 제25권5호
    • /
    • pp.542-547
    • /
    • 2014
  • 1차 사용자(primary user)는 자신에게 할당된 대역을 사용하여 통신을 수행하는데, 이때 송신 신호의 전력은 대부분 해당 대역에 집중되어 있지만, 일부는 인접 대역으로 넘어간다. 이 때문에 인접 대역이 비어 있더라도 오경보율이 예상보다 크게 발생할 수가 있다. 이전 연구 중에 인접 대역 누설 현상이 스펙트럼 센싱에 미치는 영향을 분석한 것이 있지만, 이때 페이딩을 고려하지 않았다. 본 논문에서는 페이딩 채널 환경에서 인접 대역 누설이 에너지 기반 스펙트럼 센싱 성능에 미치는 영향을 검파 확률과 오경보 확률 측면에서 분석하고자 한다.

영상을 이용한 누설탐지에서 카메라 진동 오차 보정 (Correction of Error due to Camera Vibrating During Detecting Steam Leakage by Using Image)

  • 최영철;전형섭;손기성;박종원
    • 한국소음진동공학회논문집
    • /
    • 제24권10호
    • /
    • pp.795-801
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

열화정도에 따른 배전용 피뢰기의 열화특성 분석 (Analysis of degradation of distribution lightning arresters as degradation degree)

  • 장동욱;박동배;박영국;이용희;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.140-143
    • /
    • 2000
  • The primary function of ZnO lightning arrester is to protect transmission and distribution equipment from overvoltages and to absorb electrical energy resulting from lightning or switching surges and form temporary overvoltage. However, ZnO lightning arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage and ambient temperature. So, it is important to the leakage current measurement of ZnO lightning arrester. In addition, since the resistive leakage current caused by deterioration of ZnO lightning arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. The leakage current and third harmonic component are measured and used to investigate the degradation diagnosis of ZnO element of arrester. Also the SEM photography is used to investigate the change of crystal structure of ZnO element with degradation.

  • PDF

공동주택용 폐열회수형 환기장치의 성능에 관한 측정 연구 (A Study on the Performance of Heat Recovery Ventilators for Apartment Houses)

  • 장현재;홍석진
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.26-34
    • /
    • 2008
  • Heat recovery ventilator(HRV) is recommended to improve indoor air quarlity (IAQ) and energy conservation in apartment houses. Recently, in Korea, HRV is produced from many manufacturers. However, there have been not so many experiences to apply HRV in apartment houses and verification on the performance such as heat exchange efficiency, carry-over rate, internal leakage, etc. have not been carried out sufficiently. So in this study, fan performance, heat exchange efficiency, air leakage, internal exhaust leakage, external leakage and sound level of HRV were examined for selected HRV models under domestic and international standard. Results of performance test, there were need to improve latent heat exchange efficiency and sound level of HRV.

상수관망 에너지 모의를 위한 정량화 분석기법 개발 (Development of a quantification method for modelling the energy budget of water distribution system)

  • 최두용;김상현;김경필
    • 한국수자원학회논문집
    • /
    • 제55권spc1호
    • /
    • pp.1223-1234
    • /
    • 2022
  • 기후변화에 대처하기 위한 온실가스 저감 노력은 상하수도 분야에서도 활발하게 진행되어 왔으며, 특히, 상수도 생산 및 공급과정에서 많은 에너지를 소비하는 상수관망의 에너지를 절감하기 위한 많은 기술개발이 이루어져왔다. 상수관망의 에너지 절감은 지형의 기복으로 발생되는 구조적 손실의 저감과 누수 및 마찰손실로 인한 운영 상 손실의 효율화를 통해 성취될 수 있음에도 실제 상수관망의 에너지 수지를 분석하는 단계에서 이들 인자들 상호간의 복합적 작용으로 인해 해석적인 접근뿐 아니라 수치모형을 이용한 모의에서도 한계를 노출하여 왔다. 본 연구에서는 지형의 기복, 누수 및 마찰손실의 유무에 따라 변화하는 유량, 압력수두 및 에너지를 5가지의 상수관망 상태(가설적 상태, 이상적 상태, 누수가 포함된 이상적 상태, 누수가 배제된 실제 상태, 실제 상태)에 대하여 수리 물리적 방정식을 도출하고, 이를 단순한 형태의 상수관망에 적용함으로서 에너지의 정량적 분석 및 분류, 각종 에너지 수지 구성요소별 분석과 이를 이용한 상수도 시스템의 에너지 진단이 가능하도록 하였다.

액체수소용 초저온 고압 피스톤 펌프의 기밀성 향상에 관한 기초연구 (A Study on Air-tightness of High Pressure Liquid Hydrogen Pumping System at the Low Temperature)

  • 이종구;이종민;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제24권4호
    • /
    • pp.302-310
    • /
    • 2013
  • As an initial step to develop a liquid hydrogen pump of piston type operated under cryogenic and high pressure, leakage and piston head shape for the piston pump were discussed with temperature and pressure. As the results, the leakage depended on correlation among density, viscosity, clearance area by the low temperature. In order to reduce the leakage, it was found that the air-tightness can be improved by minimizing contact surface between piston and cylinder, and also increasing pressure in-cylinder can reduce piston clearance. Among the proposed piston shapes, D type piston shape had the most air-tightness. D type piston had smaller contact surface than other piston shape and easier expansion of cup shape by pressure. The leakage of D type piston shape was found about 7%, compared with A type piston shape. But it was required that analyze about vapor lock by friction and wear resistance.

Design of a Novel Integrated L-C-T for PSFB ZVS Converters

  • Tian, Jiashen;Gao, Junxia;Zhang, Yiming
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.905-913
    • /
    • 2017
  • To enhance the zero-voltage switching (ZVS) range and power density of the phase-shift full-bridge (PSFB) ZVS converters used in geophysical exploration, an additional resonant inductor is used as a leakage inductance and a blocking capacitor which is equivalent to interlayer capacitance is integrated into a novel integrated inductor-capacitor-transformer (L-C-T). The leakage inductance and equivalent interlayer capacitance of the novel integrated L-C-T are difficult to determine by conventional methods. To address this issue, this paper presents accurate and efficient methods to compute the leakage inductance and equivalent interlayer capacitance. Moreover, the accuracy of this methodology, which is based on electromagnetic energy and Lebedev's method, is verified by an experimental analysis and a finite element analysis (FEA). Taking the problems of the novel integrated L-C-T into consideration, the losses of the integrated L-C-T are analyzed and the temperature rise of the integrated L-C-T is determined by FEA. Finally, a PSFB ZVS converter prototype with the novel integrated L-C-T is designed and tested.

Calculation of Leakage Inductance of Integrated Magnetic Transformer with Separated Secondary Winding Used in ZVS PSFB Converter

  • Tian, Jiashen;Zhang, Yiming;Ren, Xiguo;Wang, Xuhong;Tao, Haijun
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.644-651
    • /
    • 2016
  • A novel zero voltage switching (ZVS) phase shift full bridge (PSFB) converter used in geophysical exploration is proposed in this paper. To extend the ZVS ranges and increase power density of the converter, external inductor acting as leakage inductance is applied and integrated into the integrated magnetic (IM) transformer with separated secondary winding. Moreover, the loss of ZVS PSFB converter is also decreased. Besides, the analysis and accurate prediction methodology of the leakage inductance of the IM transformer are proposed, which are based on magnetic energy and Lebedev. Finally, to verify the accuracy of analysis and methodology, the experimental and finite element analysis (FEA) results of IM transformer and 40 kW converter prototypes are given.