• Title/Summary/Keyword: Leakage energy

검색결과 722건 처리시간 0.036초

Modeling and Analysis of Leakage Currents in PWM-VSI-Fed PMSM Drives for Air-Conditioners with High Accuracy and within a Wide Frequency Range

  • Sun, Kai;Lu, Yangjun;Xing, Yan;Huang, Lipei
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.970-981
    • /
    • 2016
  • Leakage currents occur in pulse-width-modulated voltage source inverter (PWM-VSI)-fed permanent magnet synchronous motor (PMSM) drives for air-conditioners, which seriously affect system safety and operation performance. High accuracy modeling and prediction of leakage currents are key issues for the design and implementation of air-conditioning products. In this study, the generation mechanism of leakage currents is discussed. A systematic modeling approach of leakage currents is proposed, including the modeling of leakage current sources and leakage current paths. By using the proposed approach, the complete model of leakage currents in PWM-VSI-fed PMSM drives for air-conditioners has been developed based on the extraction of all parameters. A comparison between the simulated leakage currents based on the developed model and measured leakage currents in the outdoor unit of an air-conditioning product is conducted. The comparison verifies the effectiveness of the proposed modeling approach, and the developed model exhibits high accuracy within a wide frequency range.

Multi-measuring기법을 이용한 원전 제어밸브의 누설진단 (Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring)

  • 김성영;김영범;김봉호;이상국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

가스 파이프라인용 30인치 볼 밸브의 누설량 평가 (Assessment of Gas Leakage for a 30-inch Ball Valve used for a Gas Pipeline)

  • 김철규;이상문;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제27권2호
    • /
    • pp.230-235
    • /
    • 2016
  • The purpose of this study is to evaluate the gas leakage for a 30-inch ball valve. The ball valve was designed and manufactured for a natural gas transportation through a long-distance pipeline mainly installed in the permafrost region. The gas leakage assessment is based on the pressure testing criteria of international standards. Pressure conditions of the gas leakage test was employed 70 bar, 100 bar, and 110 bar. The amount of the gas leakage at each pressure condition was small and had a value under the pressure testing criteria, ISO 5208. Gas leakage with respect to the test pressure was predicted by the polynomial curve fitting using the experimental results. It is found that the gas leakage rate according to the pressure is proportion to a second order curve.

Applications of MEMS-MOSFET Hybrid Switches to Power Management Circuits for Energy Harvesting Systems

  • Song, Sang-Hun;Kang, Sungmuk;Park, Kyungjin;Shin, Seunghwan;Kim, Hoseong
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.954-959
    • /
    • 2012
  • A hybrid switch that uses a microelectromechanical system (MEMS) switch as a gate driver of a MOSFET is applied to an energy harvesting system. The power management circuit adopting the hybrid switch provides ultralow leakage, self-referencing, and high current handling capability. Measurements show that solar energy harvester circuit utilizing the MEMS-MOSFET hybrid switch accumulates energy and charges a battery or drive a resistive load without any constant power supply and reference voltage. The leakage current during energy accumulation is less than 10 pA. The power management circuit adopting the proposed hybrid switch is believed to be an ideal solution to self-powered wireless sensor nodes in smart grid systems.

수소타운 정압기실 내 수소 누출 특성 연구 (A Study on Characteristics of Hydrogen Leakage in Hydrogen Town Governor Room)

  • 남태호;김동환;이정운;이승국;이연재
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.685-692
    • /
    • 2016
  • Hydrogen will be a future eco-friendly energy source that can replace current fossil fuels However when hydrogen gas leaks and people inhale a lot of hydrogen gases, they can have fatal effects fell into comas. Therefore, we need to develop a safety technology and related guidelines for reducing risks of hydrogen leakage. In this regard, we carried out demonstration tests assuming a situation of hydrogen leakage. Before the experiments, we analyze the standards for governor facilities to check vent positions and sensor positions. Then, we select four types of ventilation structures and proceeds with the experiments of hydrogen leakage at 1 LPM and 1.5 LPM. Based on the experimental results, we propose the direction on optimization of vent positions and sensor positions in the hydrogen leakage situation.

수소충전소의 안전성 평가 연구 (A Study on Safety Assessment of Hydrogen Station)

  • 표돈영;김양화;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.499-504
    • /
    • 2019
  • Due to the rapid spread and low minimum ignition energy of hydrogen, rupture is highly likely to cause fire, explosion and major accidents. The self-ignition of high-pressure hydrogen is highly likely to ignite immediately when it leaks from an open space, resulting in jet fire. Results of the diffusion and leakage simulation show that jet effect occurs from the leakage source to a certain distance. And at the end of location, the vapor cloud explosion can be occurred due to the formation of hydrogen vapor clouds by built-up. In the result, it is important that depending on the time of ignition, a jet fire or a vapor cloud explosion may occur. Therefore, it is necessary to take into account jet effect by location of leakage source and establish a damage minimizing plan for the possible jet fire or vapor cloud explosion. And it is required to any kind of measurements such as an interlock system to prevent hydrogen leakage or minimize the amount of leakage when detecting leakage of gas.

Novel Dual DC-DC Flyback Converter with Leakage-Energy Recycling

  • Yang, Lung-Sheng
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1007-1014
    • /
    • 2018
  • A novel dual DC-DC flyback converter with leakage-energy recycling is presented in this paper. Only an active switch is used for this converter. A pulse-width-modulation strategy is adopeted to control this switch. Two transformers are employed for the proposed converter. During the switch ON-period, the primary windings of the two transformers store energies. At the switch OFF-period, the energies stored in the primary windings of the two transformers are released to the output via the secondary windings of the two transformers. Meanwhile, the leakage energies of the two transformers can be recycled. The operating principles and steady-state analyses of the proposed converter are described in detail. A prototype circuit of the proposed converter is implemented for verifying the performances.

충청지역 단독주택의 기밀성능 실측 연구 (A Study on the Measurement of Airtightness Performance of Detached Houses in Chung-cheong area)

  • 윤종호;박재완;이광성;백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.65-71
    • /
    • 2008
  • The purpose of this study is to investigate an airtightness of typical Korean detached houses with field measurements. Air leakage testings by means of blower door test in accordance with ASTM E79-8 were measured in 22 detached dwellings in Daejeon and Geumsan. The results showed that detached dwellings have an average airtightness with ACH50/20 (air chang per hour at a pressure difference of 50 Pa between inside outside) of 0.82 $hr^{-1}$ which is a higher range than for typical apartments and leakage class G by normalized leakage area of ASHRAE.

Analysis of leakage factors affecting ECV performance in variable compressor

  • Mahmud, Md. Iqbal;Cho, Haeng Muk
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.183-188
    • /
    • 2014
  • Solenoid operated electromagnetic control valve (ECV) using in an external variable displacement swash plate type compressor is widely used for air conditioning control system because of its low energy consumption and high efficient characteristics. ECV controls the entire vehicle air conditioning system by means of a pulse width modulation (PWM) system that supplied from an external controller. Different pressure ports located within ECV has important functions to control the air/refrigerant flow through its internal passages. The flow paths are preciously maintained with acceptable ranges of leakage (gap) between the parts inside it which is followed by effective design and critical dimensioning of its internal features. Therefore, it saves energy losses from the solenoid operation as well as ensures the balance of forces within it. The research paper highlights analysis of the leakages (at different pressure ports) and dimensioning tolerance factors that affects the ECV performance.

Banked Memory System에서 효율적일 전력관리를 위한 KVM의 힙 메모리 관리체계 설계 (A Design of KVM Heap Memory Management for Effective Power Management in Banked Memory System)

  • 최인범;강희성;정명조;이철훈
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2005년도 한국컴퓨터종합학술대회 논문집 Vol.32 No.1 (A)
    • /
    • pp.868-870
    • /
    • 2005
  • 최근에는 자원이 제한적인 시스템을 위한 embedded JVM 환경에서 자바 응용 프로그램을 수행할 때 embedded JVM 의 성능에 따른 performance 뿐만 아니라 에너지 소비를 줄이는 일이 크게 대두되고 있다. 메모리에서 사용되는 에너지는 메모리에 접근할 때마다 소비되는 dynamic energy와 메모리에 파워가 들어와 있을 때 항상 소비되는 leakage energy 로 구분할 수 있다. embedded 환경을 고려하지 않았던 이전에는 leakage energy 가 중요한 부분으로 인식되지 않았지만, 현재는 dynamic energy 못지 않게 중요한 부분으로 인식되고 있다. 본 논문에서는 Banked Memory System을 사용하는 임베디드 JVM의 환경하에서 leakage energy를 효과적으로 줄일 수 있는 KVM의 힙 메모리 관리체계를 설계하였다.

  • PDF