• Title/Summary/Keyword: Leakage energy

Search Result 722, Processing Time 0.029 seconds

Joint Transceiver Design for SWIPT in MIMO Interference Channel (MIMO 간섭채널에서 정보와 전력의 동시 전송 (SWIPT)을 위한 송수신기 설계)

  • Seo, Bangwon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.5
    • /
    • pp.55-62
    • /
    • 2019
  • In this paper, we consider K-user multiple-input multiple-output (MIMO) interference channel and present a transceiver design for simultaneous wireless information and power transfer (SWIPT) systems. In addition, we consider a SWIPT system where an information decoding receiver and an energy harvesting receiver are co-located at the same receiver. In the proposed scheme, signal-to-leakage plus noise ratio (SLNR) is used as a cost function and a transceiver is designed to satisfy the threshold of the harvested energy. More specifically, transmitter precoding vector, receiver filter vector, and power spitting factor are simultaneously designed to maximize SLNR with a constraint on the harvested energy. Through computer simulation, we compare the signal-to-interference plus noise ratio (SINR) performance of the proposed and conventional schemes. When a special condition among the number of transmit antennas, receive antennas, and users is satisfied, the proposed scheme showed better SINR performance than the conventional scheme at low signal-to-noise ratio (SNR) range. Also, when the condition is not satisfied, the proposed scheme showed better performance than the conventional scheme at all SNR range.

Damage Index Evaluation Based on Dissipated Energy of SCH 40 3-Inch Carbon Steel Pipe Elbows Under Cyclic Loading (주기적 하중을 받는 SCH 40 3-Inch 탄소강관엘보의 소산에너지 기반의 손상지수 평가)

  • Kim, Sung-Wan;Yun, Da-Woon;Jeon, Bub-Gyu;Kim, Seong-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.112-119
    • /
    • 2021
  • The failure mode of piping systems due to seismic loads is the low-cycle fatigue failure with ratcheting, and it was found that the element in which nonlinear behavior is concentrated and damage occurs is the elbow. In this study, to quantitatively express the failure criteria for a pipe elbow of SCH40 3-inch carbon steel under low-cycle fatigue, the limit state was defined as leakage, and the in-plane cyclic loading test was conducted. For the carbon steel pipe elbow, which is the vulnerable part to seismic load of piping systems, the damage index was represented using the moment-deformation angle relationship, and it was compared and analyzed with the damage index calculated using the force-displacement relationship. An attempt was made to quantitatively express the limit state of the carbon steel pipe elbow involving leakage using the damage index, which was based on the dissipated energy caused by repeated external forces.

Study on the Establishment of the Act on the Prevention and Protection of Technology Leakage ('기술유출방지 및 보호지원에 관한 법률'제정에 관한 연구)

  • Noh, Jae-Chul;Ko, Zoon-ki
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.487-497
    • /
    • 2017
  • South Korea needs reorganization of dispute resolution system due to the frequent occurrence of a case that trade secret or technique are leaked. First, the distributed various laws are established and enforced by enacting and enforcing individual laws. Therefore, the redundancy problems, the collision of individual laws, the decline in diversity, integrity, and connectivity are issues. An independent legal system is needed by Act on the Prevention and Protection of Technology Leakage. Thereby, The support system of technological protection that is sprayed in government departments such as the Small and Medium Business Administration, the Ministry of Trade, Industry and Energy, the Patent Office, the Fair Trade Commission, the Trade Committee, the National Police Agency, and the Spy Agency integrates and unifies institutionally, and it is necessary to advance a policy with functional division. Second, the Patent Tribunal, the Invention Promotion Act, the Industrial Property Right Dispute Mediation Committee by the patent law, the Industrial Technical Dispute Mediation Committee on the Industrial Technology Outflow Prevention and Protection Law and the Medium and Small Firm Dispute Mediation and Arbitration Committee on Small Business Technology Protection Support Law are installed. However, since it established the integrated law on the Act on the Prevention and Protection of Technology Leakage, it is desirable to set the merged operation of establishment on the Technical Dispute Mediation Committee under the Small and Medium Business Administration or the Ministry of Trade, Industry and Energy.

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

Risk analysis of flammable range according to hydrogen vehicle leakage scenario in road tunnel (도로터널 내 수소차 누출시나리오에 따른 가연영역에 대한 위험성분석 연구)

  • Lee, Hu-Yeong;Ryu, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.305-316
    • /
    • 2022
  • Hydrogen energy is emerging as an alternative to the depletion of fossil fuels and environmental problems, and the use of hydrogen vehicles is increasing in the automobile industry as well. However, since hydrogen has a wide flammability limit of 4 to 75%, there is a high concern about safety in case of a hydrogen car accident. In particular, in semi-enclosed spaces such as tunnels and underground parking lots, a fire or explosion accompanied by hydrogen leakage is highly likely to cause a major accident. Therefore, it is necessary to review hydrogen safety through analysis of flammability areas caused by hydrogen leakage. Therefore, in this study, the effect of the air velocity in the tunnel on the flammability area was investigated by analyzing the hydrogen concentration according to the hydrogen leakage conditions of hydrogen vehicles and the air velocity in the tunnel in a road tunnel with standard section. Hydrogen leakage conditions were set as one tank leaking and three tanks leaking through the TPRD at the same time and a condition in which a large crack occurred and leaked. And the air velocity in the tunnel were considered 0, 1, 2.5, and 4.0 m/s. As a result of the analysis of the flammability area, it is shown that when the air velocity of 1 m/s or more exists, it is reduced by up to 25% compared to the case of air velocity of 0 m/s. But there is little effect of reducing the flammability area according to the increase of the wind speed. In particular, when a large crack occurs and completely leaks in about 2.5 seconds, the flammability area slightly increases as the air velocity increases. It was found that in the case of downward ejection, hydrogen gas remains under the vehicle for a considerably long time.

Alternative Design of 3MW Offshore PM Synchronous Generator (해상용 3 MW 영구자석형 동기발전기의 대안설계)

  • Kim, Dong-Eon;Lee, Hong-Gi;Han, Hong-Sik;Jung, Yung-Gyu;Suh, Hyung-Suck;Chung, Chin-Wha;Lim, Min-Soo;Kwak, Seung-Keun;Oh, Man-Soo;Choi, June-Hyuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.274-277
    • /
    • 2008
  • Pohang Wind Energy Research Center (PoWER-C) is developing a 3 MW Radial Flux Permanent Magnet (RFPM) Synchronous Generator for offshore Wind Energy Converter (WEC). The blade rotor rpm is 15.7 and the gear ratio is set to be 92.93. The nominal generator rpm at the rated load is about 1459. Baseline design with surface mounted PM magnets are completed. However, there is some concern about the excessive eddy current heating in the magnets. To alleviate this problem, another design with embedded magnet is going on. With embedded magnets, the generator length should be increased to compensate the increased flux leakage. But the field fluctuation in the magnets due to the slots are greatly reduced. This means less eddy currents and lower magnet operating temperature. In this report, engineering efforts for embedded rotor is presented.

  • PDF

Activation Energy Asymptotics Revisited (II) - Diffusion-Flame Structure in the Premixed-Flame Regime (활성화에너지점근법의 재고찰 (II) - 예혼합화염영역에서 확산화염구조)

  • Kim, Jong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.4
    • /
    • pp.35-46
    • /
    • 2004
  • Activation energy asymptotics (AEA) for Linan#s premixed-flame regime is revisited in this paper. First, the detailed AEA procedure for the premixed-flame regime is demonstrated, so that the practitioners of AEA could easily apply the method to their own problems. In addition, the controversies surrounding the premixed-flame regime, namely the closure controversy and fast-time instability paradox, are explained. Finally, the limitation of AEA, mainly arising from the wrong prediction of fuel leakage through the reaction zone, is examined and the Zel#dovich-Linan kinetics is introduced as an alternative to meet the needs of modern combustion analysis, where the detailed chemical structure of flame is demanded.

  • PDF

Fracture and Protection Technologies against Impulse of Power Arresters (전력용 피뢰기의 임펄스에 의한 파손과 대척 기술)

  • 한세원;조한구;김석수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.190-193
    • /
    • 2001
  • ZnO varistors have been widely used to protect power system and electronic system against overvoltages based on their excellent nonlinearity. In order to increase their protection capability, the fracture and protection technologies of arresters have to study according to their applications, namely ImA DC voltage, leakage currents, impulse residual voltages, withstanding capability to impulse surge, and energy absorption capability. ZnO varistors which have nonlinear current-voltage characteristic name a number of failure mechanism when ZnO elements absorb surge energies. Failure mode by thermal stress and Pin hole are among the most common failure mechanism at the high current surge current. In this study, the fracture mechaism of power arresters are introduced and protection technologies are researched. In particular the effect of thermal stress by surge currents to ZnO elements and methods against arc surge energy through withstand structure design of arrester are discussed.

  • PDF

PCM Main Memory for Low Power Embedded System (저전력 내장형 시스템을 위한 PCM 메인 메모리)

  • Lee, Jung-Hoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.10 no.6
    • /
    • pp.391-397
    • /
    • 2015
  • Nonvolatile memories in memory hierarchy have been investigated to reduce its energy consumption because nonvolatile memories consume zero leakage power in memory cells. One of the difficulties is, however, that the endurance of most nonvolatile memory technologies is much shorter than the conventional SRAM and DRAM technology. This has limited its usage to only the low levels of a memory hierarchy, e.g., disks, that is far from the CPU. In this paper, we study the use of a new type of nonvolatile memories - the Phase Change Memory (PCM) with a DRAM buffer system as the main memory. Our design reduced the total energy of a DRAM main memory of the same capacity by 80%. These results indicate that it is feasible to use PCM technology in place of DRAM in the main memory for better energy efficiency.

Characteristics of Lubrication between Slipper and Swashplate in Swashplate Type Hydraulic Piston Pump (사판식 유압 피스톤 펌프의 슬리퍼와 사판 간의 윤활 특성)

  • Cho, Ihnsung
    • Tribology and Lubricants
    • /
    • v.29 no.3
    • /
    • pp.186-191
    • /
    • 2013
  • Hydraulic systems are used to transform mechanical energy into fluid energy and vice versa. They are widely applied in various industries; e.g., they are used in automobiles, public works, rockets, machine tools, heavy construction equipment, and airplanes. Hydraulic pumps are used to transform the energy in these systems. In this study, with the basic operation principles as a starting point, I attempted to clarify how the shape of a slipper affects the lubrication characteristics under practical conditions. A swashplate with a tilt angle of zero and capable of rotating motion was used, along with other devices. A slipper was located at 45 mm eccentricity from the center of the swashplate. The results of this experiment indicated that the shape of the bottom surface of a slipper affects the load capacity, leakage flow, and lubrication characteristics and that the slipper is one of the most important parts for improving the pump efficiency.