• Title/Summary/Keyword: Leakage current control system

Search Result 94, Processing Time 0.027 seconds

PreBAC: a novel Access Control scheme based Proxy Re-Encryption for cloud computing

  • Su, Mang;Wang, Liangchen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.5
    • /
    • pp.2754-2767
    • /
    • 2019
  • Cloud computing is widely used in information spreading and processing, which has provided a easy and quick way for users to access data and retrieve service. Generally, in order to prevent the leakage of the information, the data in cloud is transferred in the encrypted form. As one of the traditional security technologies, access control is an important part for cloud security. However, the current access control schemes are not suitable for cloud, thus, it is a vital problem to design an access control scheme which should take account of complex factors to satisfy the various requirements for cipher text protection. We present a novel access control scheme based on proxy re-encryption(PRE) technology (PreBAC) for cipher text. It will suitable for the protection of data confidently and information privacy. At first, We will give the motivations and related works, and then specify system model for our scheme. Secondly, the algorithms are given and security of our scheme is proved. Finally, the comparisons between other schemes are made to show the advantages of PreBAC.

A Study on Dynamic Characteristics of EFPCD for Electrical Fire Prevention (전기화재 예방을 위한 EFPCD동작 특성에 관한 연구)

  • 이상호;오홍석
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.8-11
    • /
    • 2002
  • Recently, the spark and the overheat due to in the failure of pressure contacts on connecting points and the momentary short circuit have been the major causes of electrical fire because these may cause the deposition and the graphite of insulating materials in electrical wiring system. Also, because in these cases the current is a surge one, the losses and faults of a communication, a home appliances, a computer and a measuring instrument may occur. Especially, in such cases, we are very difficult to detect the failure of pressure contacts on connecting points and the momentary short circuit. In this paper, we have developed an auxiliary control device, the electrical fire prevention control device(EFPCD), of an earth leakage breaker(ELB). And we can pre-vent the electrical fire caused by the spark and the overheat occurring in the failure of pressure contacts in connecting points and the momentary short circuit with the EFPCD.

Design of 5'' True Color FED Driving System (5'' True Color FED 구동시스템 설계)

  • Shin, Hong-Jae;Kwon, Oh-Kyong;Kwack, Kae-Dal
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.5
    • /
    • pp.70-78
    • /
    • 2001
  • We have developed a novel driving system of 5' true color FED using voltage controlled PWM method which has current control effect. The proposed method has the advantage of voltage controlled pulse width modulation method and current control method. Also, we propose a new circuit model of FED subpixel for circuit simulation of FED driving circuits, considering some parasitic effects, i.e., cross talk, line coupling effect and leakage current to the adjacent cathode lines. Output stage of the data driving circuit is optimized using the proposed circuit model. In video data processing, FED controller uses the parallel processing of R.G.B input data, so duty ratio is maximized and brightness of FED increases. With this results, no noise and high quality performance is achieved in display of 5' true color FED.

  • PDF

A Contact-less Power Supply for Photovoltaic Power Generation System (태양광 발전 시스템을 위한 무접점 전원장치)

  • Lee, Hyun-Kwan;Kong, Young-Su;Kim, Yoon-Ho;Lee, Gi-Sik;Kang, Sung-In;Chung, Bong-Geun;Kim, Eun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.216-223
    • /
    • 2006
  • The high efficiency full-bridge LLC resonant converter using a contact-less transformer Is proposed for the photovoltaic power generation system. For the series resonance with a series capacitor, the LLC resonant converter utilizes the leakage inductance and magnetizing inductance of a contact-less transformer Unlike the conventional series resonant converter operated to the continuous resonant current at above resonance frequency, the proposed converter operates to the discontinuous resonant current at the narrow frequency control range below resonance frequency. Due to the discontinuous mode resonant current, the proposed converter can be achieved the zero voltage switching (ZVS) in the primary switches and the zero current switching (ZCS) in the secondary rectification diodes without my auxiliary circuit. In this paper, the experimental results of the proposed full-bridge LLC resonant converter using a contact-less transformer are verified on the simulation based on the theoretical analysis and the 150W experimental prototype.

Preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations (765kV 신가평, 신태백 변전소 예방진단시스템)

  • Kweon, D.J.;Shim, E.B.;Jung, G.J.;Kim, B.J.;Kim, J.H.;Yoo, Y.P.;Eun, J.Y.;Shin, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1694-1697
    • /
    • 2002
  • KEPCO is planing to adopt a preventive diagnostic system to obtain the reliability of transformer and GIS in 765kV substation. KEPRI has developed the preventive diagnostic system for 765kV substation since 1997. We used various sensors and fault detecting devices such as a dissolved gas analyzer in oil, a ultrasonic detector and LA leakage current detector, etc., and carried out adaptation tests at the both a laboratory and a site. We developed a data acquisition system, a communication control unit and a server system as well. Furthermore, monitoring program and diagnostic expert system were also developed. This paper describes the preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations which will be operated from 2004.

  • PDF

Low-Power Motion Estimator Architecture for Deep Sub-Micron Multimedia SoC (Deep Submicron 공정의 멀티미디어 SoC를 위한 저전력 움직임 추정기 아키텍쳐)

  • 연규성;전치훈;황태진;이성수;위재경
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.95-104
    • /
    • 2004
  • This paper propose a motion estimator architecture to reduce the power consumption of the most-power-consuming motion estimation method when designing multimedia SoC with deep submicron technologies below 0.13${\mu}{\textrm}{m}$. The proposed architecture considers both dynamic and static power consumption so that it is suitable for large leakage process technologies, while conventional architectures consider only dynamic power consumption. Consequently, it is suitable for mobile information terminals such as mobile videophone where efficient power management is essential. It exploits full search method for simple hardware implementation. It also exploits early break-off method to reduce dynamic power consumption. To reduce static power consumption, megablock shutdown method considering power line noise is also employed. To evaluate the proposed architecture when applied multimedia SoC, system-level control flow and low-power control algorithm are developed and the power consumption was calculated based on thor From the simulation results, power consumption was reduced to about 60%. Considering the line width reduction and increased leakage current due to heat dissipation in chip core, the proposed architecture shows steady power reduction while it goes worse in conventional architectures.

Electrical Properties of Zinc Oxide Varistor with $\alpha-Zn_7Sb_2O_{12}$ ($\alpha-Zn_7Sb_2O_{12}$ 첨가에 의한 Zinc Oxide 바리스터의 전기적 특성)

  • 김경남;한상목
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.11
    • /
    • pp.1396-1400
    • /
    • 1994
  • Electrical properties in the ZnO-Bi2O3-CoO-Zn7Sb2O12 system were investigated with Zn7Sb2O12 content (0.1~2 mol%). The increase of the Zn7Sb2O12 content inhibited the grain growth of ZnO, which showed a narrow grain size distribution of ZnO. The breakdown voltage (Vb) increased markedly with 1 mol% Zn7Sb2O12 addition due to the grain growth control behaviour of the Zn7Sb2O12 . The nonlinear I-V characteristic was significantly influenced by the Zn7Sb2O12 content (or Bi2O3/Zn7Sb2O12 ratio). Addition of 0.5 mol% Zn7Sb2O12 showed the highest nonlinear coefficient ($\alpha$) of 43. The leakage current in prebreakdown region was decreased with increasing Zn7Sb2O12 content.

  • PDF

Carbonization Behavior due to Surface Tracking (연면 트래킹에 의한 탄화 거동)

  • Jung, Yeon-Ha;Jang, Tae-Jun;Shong, Kil-Mok;Roh, Young-Su;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.28-33
    • /
    • 2007
  • In this paper, we are studied on the direction and formation of carbonized conductive path according to surface leakage current between electrodes. The characteristics of the tracking as surface is broken down between exposed live parts. Using the HSIS(high speed imaging system. 100,000[fps], redlake ltd., USA), it took photographs by arc growth mechanism occurred in on/off surge, ground fault and discharge between electrodes. Then the results was analyzed. Hereafter, it expected effects that application of energy utility technology through the arc control.

Single Pulse-Width-Modulation Strategy for Dual-Active Bridge Converters

  • Byen, Byeng-Joo;Jeong, Byong-Hwan;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.137-146
    • /
    • 2018
  • This paper describes a single pulse-width modulation control strategy using the Single Pulse-Width Modulation (SPWM) method with a soft-switching technique for a wide range of output voltages from a bidirectional Dual-Active Bridge (DAB) converter. This method selects two typical inductor current waveforms for soft-switching, and proposes a rule that makes it possible to achieve soft-switching without any compensation algorithm from the waveforms. In addition, both the step-up and step-down conditions are analyzed. This paper verifies that the leakage inductance is independent from the rule, which makes it easier to apply in DAB converters. An integrated algorithm, which includes step-up and step-down techniques, is proposed. The results of experiments conducted on a 50-kW prototype are presented. The system efficiency is experimentally verified to be from 85.6% to 97.5% over the entire range.

Development of Arc Fault Interruption Control Circuit of Fault Voltage Sensing Type (사고전압 감지형 아크차단 제어회로 개발)

  • Kwak, Dong-Kurl;Byun, Jae-Ki;Lee, Bong-Seob
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.1-5
    • /
    • 2013
  • This paper studies on an arc fault interruption control circuit (AFICC) of fault voltage sensing type. The proposed voltage sensing type AFICC (VST_AFICC) is an electrical fire prevention apparatus that operates the existing circuit breaker with sensing the instantaneous voltage drop of line voltage when occurs electrical faults. The existing Earth Leakage Circuit Breaker (ELB), Molded_case Circuit Breaker (MCCB), and Residual Current Protective Devices (RCDs) used in low voltage distributing system don't have protective capability from electric arc faults to be a major factor of electrical fire. In this paper to improve such problems, a new VST_AFICC using the distortion of voltage waveform when occurs electrical faults is proposed to prevent electrical fire. There is characteristic that the control method of proposed apparatus is different from previous current sensing type. The proposed AFICC has merit that is manufactured by small size and light weight. The practicality of a new VST_AFICC is also verified through various operation analysis.