Event Log Validity Analysis for Detecting Threats by Insiders in Control System

  • Kim, Jongmin;Kang, Jiwon;Lee, DongHwi
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.1
    • /
    • pp.16-21
    • /
    • 2020
  • Owing to the convergence of the communication network with the control system and public network, security threats, such as information leakage and falsification, have become possible through various routes. If we examine closely at the security type of the current control system, the operation of the security system focuses on the threats made from outside to inside, so the study on the detection system of the security threats conducted by insiders is inadequate. Thus, this study, based on "Spotting the Adversary with Windows Event Log Monitoring," published by the National Security Agency, found that event logs can be utilized for the detection and maneuver of threats conducted by insiders, by analyzing the validity of detecting insider threats to the control system with the list of important event logs.

A Study on Conversion Security Control System for Industrial Security (산업보안을 위한 융합보안관제시스템에 관한 연구)

  • Ha, Ok-Hyun
    • Convergence Security Journal
    • /
    • v.9 no.4
    • /
    • pp.1-6
    • /
    • 2009
  • Current paradigm of industrial security is changing into the effective operation and management from simple establishment of security equipments. If the physical security system(entry control system, video security system, etc.) and the IT integrated security control system are conversed, it makes us possible to prevent, disrupt and track afterwards the insider's information leakage through the risk and security management of enterprise. That is, Without the additional expansion of the existing physical security and IT security manpower, the establishment of systematic conversion security management process in a short time is possible and can be expected the effective operation of professional organization system at all times. Now it is needed to build up integrated security management system as an individual technique including the security event collection and integrated management, the post connected tracking management in the case of security accident, the pattern definition and real time observation of information leakage and security violation, the rapid judgement and response/measure to the attempt of information leakage and security violation, the establishment of security policy by stages and systematically and conversion security.

  • PDF

A Study on the Corrosion Control and Protection of 154kV Underground Pipe-type Oil Filled (POF) Cable (154kV 지중 POF 케이블의 부식방지(腐蝕防止)에 관한 연구(硏究))

  • Lee, D.I.;Kim, J.B.;Jeong, D.W.;Kim, D.K.;Lee, J.B.;Jeong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.161-165
    • /
    • 1990
  • KEPCO has experienced eight oil leakage failures due to POF cable corrosion in the 154KV underground POF cable transmission line since the line was operated in 1976. Experimentally, We have verified that the cause of the failure is electrolytic corrosion of the cable owing to subway leakage current. For the countermeasure, We adopted the total Cathodic Protection System by the use of Victim Anode, Forced Drainage Method and Impressed Current Method with polarization cell.

  • PDF

A Study on Direct Current Measurement Using Magneto-Optical LMF Method (자기장학 누설자속법을 응용한 직류전류계측법에 관한 연구)

  • Lee, Jin-Yi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.566-572
    • /
    • 2004
  • It is necessary to measure the direct current with a non-contact methodology for the liquid or gas phase, as welt as the conducting metals. This paper described a theoretical consideration and experimental verification for a non-contact quantitative direct current measurement system using the Faraday effect and magnetic flux leakage. The leakage of magnetic flux occurs around a gap when a ferromagnetic core including the discontinuous gap is magnetized. Two large anisotropic domains in a magneto-optical film are occurred by the vertical component of leaked magnetic flux and the domain walls are paralleled to the center of the gap. Here, the symmetrical arrangement of domains are deflected when a vertical magnetic field is applied to the magneto-optical film. The domain wall of the magneto-optical film are relocated when a measuring current passes through the ferromagnetic core. Therefore, a direct current passing through the core can be determined quantitatively by the measurement of moving distance of the domain wall.

Design & characteristics of impulse current test system for station class(up to class 5) (송변전급(up to class 5) Impulse current test system의 설계 및 특성)

  • Kim, Seok-Sou;Choi, Ike-Sun;Kang, Young-Sik;Park, Byung-Rak;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1146-1149
    • /
    • 2004
  • A new developed impulse current test system(100kV, 250kJ)is presented, which can carry out all impulse current and performance tests on surge arrester sections with rated voltage up to 12kV according to IEC 60099-4(2001). The maximum achievable peak value is 200kA for the impulse current $4/10{\mu}s$ and 60kA for the $30/80{\mu}s$ and $8/20{\mu}s$. The long duration current impulse is realized from class 1 to class 5. The digital transient recorder(4 channels 60MS/S 10bit) is used for measuring AC voltage, impulse current, reference voltage and leakage current. The complex control, measuring, evaluation and data storage system is controlled by one industrial PC system.

  • PDF

The Implementation of Current Compensation Controller in Driving Voltage type Converter considering the Unbalance of Reactor at the Source Side (전원측 리액터 불평형을 고려한 전압형 컨버터의 전류 보상 제어기 구현)

  • Chun Ji-Yong;Cho Yu-Hwan;Lee Geun-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.413-420
    • /
    • 2004
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining method of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. In order to solve the problem which the unbalanced system control is used to leakage transformer not equaled reactance by each phase in rectifier system. The proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

Development of Remote Control and Monitoring System for HID Street-lamp Based on Low Cost Zigbee Communication Network (저 가격형 Zigbee 통신 네트워크 기반 HID 가로등의 원격 제어 및 감시 시스템 개발)

  • Chung, Wan-Sup;Kim, Yang-Bae;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.69-73
    • /
    • 2014
  • In this paper, remote control and surveillance monitoring system of HID street-lamp using low-cost type of Zigbee communication module was developed. A plurality of capacitors with different capacity are attached to magnetic ballast for HID lamps. Changes in the amount of illumination can be adjusted by the changes in capacity so that the electric energy can be reduced. In Zigbee communication module, a ATmega128L microprocessor is used and in main CPU, ARM9 Core is used to construct a low-cost smart system. In surveillance monitoring systems, the system was configured to remote monitoring of presence of error in the lamp abnormalities, the status of leakage current and abnormalities of ballasts and capacitors and the validity of the proposed empirical experiment was confirmed.

Development of ELCB with Built-in Algorithm for DC Leakage Current Detection (DC 누설 전류 검출 알고리즘을 내장한 누전 차단기 개발)

  • Joo, Nam-Kyu;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.2
    • /
    • pp.165-169
    • /
    • 2014
  • Digital load is increasing suddenly for various reasons, such as easy control and management. Accordingly, a consumption pattern of load is becoming DC. However, the power supply is supplied by AC power. The load power supply substantially needs DC power. AC power has to be converted to DC power. Renewable energy sources like solar, wind, fuel cells are DC power generation, but the transfer needs to through by AC power, thus DC power has to be converted to AC power. Resultantly, a multi-stage conversion loss is constantly increasing. The power distribution system of DC-based is required for effective use of these energy sources. This requires a DC load, as well as is necessary to develop DC ELCB which are able to detect DC leakage current for implementing protection. In this study, it realize detection algorithm about DC leakage current to verify the performance of the sensor and apply it to the ELCB which is based on DC. Therefore, it is expected to protect operating of DC power distribution system.

$H_\infty$ Control Apprach to a Magnetic Levitation System with Two Poles on $j_\omega$-Axis

  • Qi, Run-De;Tsuji, Teruo;Oguro, Ryuichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.339-344
    • /
    • 1993
  • An H$_{\infty}$ control system design for a magnetic levitation system is presented. In the control system design, we consider the influence of both disturbances and uncertainties in the model. The main disturbances stem from the position sensors.The uncertainties are divided into electromagnetic and mechanical ones: the former are due to the gain change in the current amplifier, the influence of leakage flux and modelling error in the magnetic circuit and the latter are due to the changes of the mass and the moments of inertia of the vehicle. Therefore, the designed controller is indispensable to guarantee the robustness of this system for both stability and performance. The controller design is based on the standard H$_{\infty}$ optimal control problem. As the novel features in this paper :(1) there are two poles on j.omega.-axis in the control model;(2) an integrator is included in the controller so that equivalently there are three poles on j.omega.-axis in the model. Finally, several experiments and simulations are carried out to verify the high performance and robustness of the designed control system.m.

  • PDF

LCL Resonant Compensation of Movable ICPT Systems with a Multi-load

  • Hua, Jie;Wang, Hui-Zhen;Zhao, Yao;Zou, Ai-Long
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1654-1663
    • /
    • 2015
  • Compared to LC resonance, LCL resonance has distinct advantages such as a large resonant capability, low voltage and current stresses of the power device, constant voltage or current output characteristics, and fault-tolerance capability. Thus, LCL resonant compensation is employed for a movable Inductive Contactless Power Transfer (ICPT) system with a multi-load in this paper, which achieves constant current output characteristics. Peculiarly, the primary side adopts a much larger compensation inductor than the primary leakage inductor to lower the reactive power, reduce the input current ripple, generate a large current in the primary side, and realize soft-switching. Furthermore, this paper proposes an approximate resonant point for large inductor-ratio LCL resonant compensation through fundamental wave analysis. In addition, the PWM control strategy is used for this system to achieve constant current output characteristics. Finally, an experimental platform is built, whose secondary E-Type coils can ride and move on a primary rail. Simulations and experiments are conducted to verify the effectiveness and accuracy of both the theory and the design method.