• Title/Summary/Keyword: Leakage characteristics

Search Result 1,644, Processing Time 0.036 seconds

An Analysis of the Flow Characteristics in the Tip Clearance of Axial Flow Rotor (축류 회전차 팁 틈새에서의 유동특성 해석)

  • 정재구;이명호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.735-745
    • /
    • 2004
  • A linear cascade of NACA 65-1810 profiles are investigated for tip leakage flow characteristics. and calculation results are compared with experimental result. STAR-CD commercial code was used to solve the three dimensional incompressible Navier-Stokes equation that was adopted for steady flow and high Reynolds $\kappa$- $\varepsilon$turbulent model. Numerical calculation of a linear cascade is carried out to investigate effect of tip clearance on pitchwise variations of velocity Profiles. and static pressure distributions on the blade surface at spanwise positions. In case of evolution of tip vortex core location. tip vortex geometry and static pressure at the center of the tip vortex core compared with experimental results. Calculation results are agreed well with the experimental data, and validated. The static pressure losses by tip leakage flow at 2% tip clearance were more than those at 1% tip clearance.

Overmodulation Characteristics of Carrier Based MVPWM for Eliminating the Leakage Currents in Three-Level Inverter (3-레벨 인버터의 누설전류 제거를 위한 캐리어 기반 MVPWM의 과변조 특성)

  • Lee, Eun-Chul;Choi, Nam-Sup;Ahn, Kang-Soon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.509-516
    • /
    • 2015
  • The overmodulation characteristics of a carrier-based medium vector pulse width modulation (CBMVPWM) are examined in this study. CBMVPWM can completely eliminate leakage currents in a three-phase, three-level inverter using only the switching states with the same common mode voltage even in an overmodulation operation. The analytic equations for the magnitude of the output voltage and the switching frequency are derived for overmodulation operation, and the effect of dead time on the leakage current is demonstrated. This study presents the operating principle of CBMVPWM, basic overmodulation features, and simulations and experiments for operating verification.

Numerical Study of Leakage Flow Characteristics by Tip Clearance of Turbine Cascades (터빈익렬 말단간극에 따른 누설유동특성에 대한 수치해석적 연구)

  • Yang S. Y.;Myong H. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.102-108
    • /
    • 2002
  • Numerical analysis has been conducted in order to simulate the flow characteristics by tip clearance of turbine cascades. A 3-D Navier-Stokes CFD code based on body-fitted coordinate system, pressure-correction and finite volume method has been used along with a commercial CFD code. The present results have showed that the development and generation of leakage vortex, vortex within tip clearance, etc. are clearly simulated, consistent with the generally known tendency. The leakage vortex occurs mainly by a separation of leakage flow that arises due to a pressure difference between two surfaces of the blade at the tip.

  • PDF

A Study on Starting Current-Time Characteristics of a Small Squirrol Cage Induction Motor (소형농형3상유전전동기의 기동전류-시간에 관한 연구)

  • 노창주;김윤식
    • 전기의세계
    • /
    • v.27 no.5
    • /
    • pp.69-75
    • /
    • 1978
  • 3 phase induction motor applied in the method of connecting it directly across the line needs large current when it starts. At that time, leakage magnetic pathes of interior of the motor are severely saturated and leakage reactances are decreased because of saturation. Consequently, increased current and raised powerfactor yield increase of starting torque. The author, noticing those phenomena, derived experimentally the raion of decreasing leakage reactance from the fact that when voltage applied to motor is increased under locked condition the magnitude of current and phase angle are varied, and determined tha equations of starting current and starting torque, considering the decrease of leakage reactance by the large starting current. The author calculated the characteristics of Current-Time and Speed-Time with the determined equation at specific load conditions, and compared the values obtained from above calculations with those from circle diagram's method and the practically recorded values at same load conditions. Therefore, the authos got a confidience that the results of the derived theory coincide with the practically measured values more well than circle diagram's results and circle diagram's equation should be modified in order to analize the starting status of a induction motor.

  • PDF

Characteristics of leakage currents flowing through ZnO varistor exposed to surge currents (서지전류가 입사된 ZnO 바리스터에 흐르는 누설전류의 특성)

  • Lee, Bok-Hee;Li, Feng;Lee, Su-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.338-341
    • /
    • 2006
  • This paper presents the leakage current characteristics of ZnO varistors exposed to the $8/20{\mu}s$ lightning impulse currents as functions of the number of injection and amplitude of impulse currents. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of $5[kA_p]$ was used. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents were measured under 60 Hz AC voltages. The trend curves of resistive leakage current of ZnO varistors were analytically calculated.

  • PDF

Characteristics of Leakage Current by Polishing Pressures in CMP of BLT films Capacitor for applying FeRAM (FeRAM 적용을 위한 BLT 캐패시터 제조시 CMP 공정 압력 변화에 따른 누설전류 특성)

  • Jung, Pan-Gum;Kim, Nam-Hoon;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.137-137
    • /
    • 2006
  • 본 연구에서는 FeRAM 적용을 위한 BLT 캐패시터 제조시 CMP 공정압력 변화에 따른 Leakage Current의 특성에 대해서 연구하였다. 6-inch Pt/Ti/Si 웨이퍼를 사용하였으며, 기판 위에 졸-겔(Sol-Gel)법으로 모든 BLT를 스핀코팅을 이용하여 증착시켰다. 증착된 BLT는 $200^{\circ}C$에서 기본 열처리 후 다시 $700^{\circ}C$에서 후속 열처리 하였다. 이러한 과정을 두번 반복하였며, FeRAM 적용을 위한 BLT 캐패시터 제조시 CMP 공정 중 압력 변화를 달리하여 BLT 캐패시터를 제조한 후 Leakage Current를 측정하였다. 결과적으로 CMP 공정 시 압력의 증가에 따라 Leakage Current값이 증가하였다. CMP 공정시 압력과 박막 표면의 스크레치로 증가로 인해 Leakage Current의 증가하였다고 판단된다.

  • PDF

Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators (열화된 고분자애자의 카올린 오손에따른 표면방전특성)

  • Park, Jae-Jun;Ga, Pyung-Hyun;Seo, Ui-Won;Jung, Myeong-Yeon;Song, Il-Kwen;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

Correlation between Capacitance and Structure-optical Properties of Semiconductor with Zero Leakage Current (누설전류 Zero인 반도체 물질의 구조적 광학적 특성과 전도성과의 상관성)

  • Yun, Tae Hwan;Oh, Teresa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.27-31
    • /
    • 2015
  • It was the electrical properties of ZnS treated by the annealing in a vaccum and an atmosphere conditions to reseached the leakage current effect of semiconductor devices. Most samples were shown the non-linear with unipolar properties, but the ZnS annealed at $100^{\circ}C$ in a vaccum was only observed no leakage current in a range of -20 V< voltage < 15 V. The crystallinity of ZnS with no leakage current was improved and optical property was also improved. Because the ambipolar characteristics and low leakage currents originated from the extension effect of a depletion width by electron-hole combination in the depletion layer.

A Study on the Characteristics of Volumetric Efficiency of an Axial Piston Pump considering Piston Tilting

  • Park, In-Kyu;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • v.10 no.1_2
    • /
    • pp.37-42
    • /
    • 2009
  • This paper presents the characteristics of volumetric efficiency of an axial type piston pump considering the piston tilting. A numerical analysis is carried out in order to obtain the pressure distribution considering the fluid inertia at the notch of the valve plate. The cylinder pressure variation and the discharge flow rate are measured experimentally according to the operating conditions such as supply pressure, rotational speed, and viscosity of the working fluid by using the cam type test apparatus. Leakage is also measured considering piston tilting. The characteristics of the volumetric efficiency are analyzed with respect to various operating conditions and leakage is also analyzed according to the piston tilting angle. Results are applicable to improve the design of an axial type piston pump.

Characteristics analysis of field aged distribution surge arresters (경년에 따른 배전용 피뢰기의 열화특성)

  • Cho, Seong-Soo;Kim, Ju-Yong;Kim, Chan-Young;Song, Il-Keun;Park, Jung-Shin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2323-2325
    • /
    • 1999
  • This paper presents characteristics of the aged and new 18kV surge arresters. In order to investigate aging characteristics, we measured total leakage current and resistive leakage current using specially made leakage current measurement system and also investigated $tan{\delta}$ of the arresters and microstructure of the elements. Through the investigation we found that all of the arresters does not aged for 2 years field operation.

  • PDF