• 제목/요약/키워드: Leakage characteristics

검색결과 1,644건 처리시간 0.042초

단순상유도전동기의 등가회로와 도식적 특성산정법 및 정수결정에 의한 특성산정법 (The Equivalent Circuit, The Graphically Calculating Method Of The Characteristics, And The Calculating Method By Determination Of Equivalent Circuit Parameters In Single Phase Induction Motor)

  • 오긍렬
    • 전기의세계
    • /
    • 제22권1호
    • /
    • pp.42-51
    • /
    • 1973
  • The contriving equivalent circuit of single phase induction motor which does not separate the primary leakage reactance and the secondary leakage reactance by the revolving field theory, and the graphically calculating method of the characteristics with T-type circle diagram of three phase induction motor which does not suppose the primary leakage reactance can be drawn up only by the no load test, the lock test, and measuring the resistance of stator winding are suggested in this paper. The method which can calculate the parameters of the equivalent circuit and the characteristics with no load test, lock test and measuring resistance of stator windings is suggested in this paper. Considered the exciting current in lock test, we could calculate very accurate characteristics of the single phase induction motor.

  • PDF

방조제 누수지점 탐지를 위한 SP및 단극배열 전기비저항탐사의 적용 (Application of SP and Pole-pole Array Electrical Resistivity Surveys to the Seawater Leakage Problem of the Embankment)

  • 송성호;이규상;김진호;권병두
    • 자원환경지질
    • /
    • 제33권5호
    • /
    • pp.417-424
    • /
    • 2000
  • We applied SP monitoring and resistivity surveys using the pole-pole electrode array to seawater leakage problems in the Youngsan estuary dam and the Eoeun embankment to estimate and detect the zone of seawater leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. For this reason, SP monitoring and the pole-pole array resistivity surveys, which are relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity (EC) and temperature variations along the inner part of Youngsan estuary dam to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincided with tidal variations at each embankment. At the leakage zones in the Youngsan estuary dam and the Eoeun embankment, SP anomalies are in the range of -60~-85 mV and -20~-50 mV, respectively, and true resistivity values obtained by 2-D inversion are 3~15 ohm-m and below 0.3 ohm-m, respectively. Both SP monitoring and the pole-pole array resistivity method are found to be quite effective for investigation of seawater leakage zones in the embankment.

  • PDF

Excimer laser로 재결정화한 LDD구조의 poly-Si TFT 제작 (Fabrication of the LDD Structure poly-Si TFT with Excimer Laser Recrystallization Process)

  • 정준호;박용해
    • 전자공학회논문지A
    • /
    • 제32A권2호
    • /
    • pp.324-331
    • /
    • 1995
  • The leakage current characteristics of the low temperature processed LDD structure poly-Si TFT is analyzed. The excimer laser technology was applied to the recrystallization process of poly-Si film and the maximum processing temperature was retained under 600.deg.C. From the fabricated LDD space 0.3.mu.m to 3$\mu$m, the best on/off current ration could be obtained with the 1.3$\mu$m LDD space. And the threshold voltage did not increase more than 4V over 0.8$\mu$m LDD space. The characteristics of leakage current was compared to non-LDD structure TFT to analyze the mechanism of leakage current. Consequently, it could be concluded that the leakage current is strongly affected by the trap states as well as high electric field between gate and drain.

  • PDF

Numerical Study on Flow Characteristics at Blade Passage and Tip Clearance in a Linear Cascade of High Performance Turbine Blade

  • Myong, Hyon-Kook;Yang, Seung-Yong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권4호
    • /
    • pp.606-616
    • /
    • 2003
  • A numerical analysis has been conducted in order to simulate the characteristics of complex flow through linear cascades of high performance turbine blade with/without tip clearance by using a pressure-correction based, generalized 3D incompressible Wavier-Stokes CFD code. The development and generation of horseshoe vortex, passage vortex, leakage vortex, tip vortex within tip clearance, etc. are clearly identified through the present simulation which uses the RNG k-$\varepsilon$ turbulent model with wall function method and a second-order linear upwind scheme for convective terms. The present simulation results are consistent with the generally known tendency that occurs in the blade passage and tip clearance. A 3D model for secondary and leakage flows through turbine cascades with/without tip clearance is also suggested from the present simulation results, including the effects of tip clearance height.

Investigation on Flashover Development Mechanism of Polymeric Insulators by Time Frequency Analysis

  • Muniraj, C.;Krishnamoorthi, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1503-1511
    • /
    • 2013
  • This paper deals with the analysis of leakage current characteristics of silicone rubber insulator in order to develop a new condition monitoring tool to identify the flashover of outdoor insulators. In this work, laboratory based pollution performance tests are carried out on silicone rubber insulator under ac voltage at different pollution levels and relative humidity conditions with sodium chloride (NaCl) as a contaminant. Min-Norm spectral analysis is adopted to calculate the higher order harmonics and Signal Noise Ratio (SNR). Choi-Williams Distribution (CWD) function is employed to understand the time frequency characteristics of the leakage current signal. Reported results on silicone rubber insulators show that the flashover development process of outdoor polymer insulators could be identified from the higher order harmonics and signal noise ratio values of leakage current signals.

GaAs MESFET의 온도변화에 다른 게이트 누설전류 특성 (Gate Leakage Current Characteristics of GaAs MESFETS′ with different Temperature)

  • 원창섭;김시한;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.50-53
    • /
    • 2001
  • In this study, gate leakage current mechanism has been analyzed for GaAs MESFET with different temperatures ranging from 27$^{\circ}C$ to 300$^{\circ}C$ . It is expected that the thermionic and field emission at the MS contact will dominate the current flow. Thermal cycle is applied to test the reliability of the device. From the results, it is proved that thermal stress gradually increases the gate leakage current at the same bias conditions and leads to the breakdown and failure mechanism which is critical in the field equipment. Finally the gate contact under the repeated thermal shock has been tested to check the quality of Schottky barrier and the current will be expressed in the analytical from to associate with the electrical characteristics of the device.

  • PDF

An Optical Configuration for Vertical Alignment Liquid Crystal cell with Wide Viewing Angle

  • Ji, Seung-Hoon;Lee, Gi-Dong
    • Journal of Information Display
    • /
    • 제9권2호
    • /
    • pp.22-27
    • /
    • 2008
  • We propose an optical configuration of a vertical alignment (VA) liquid crystal (LC) cell to eliminate the light leakage in the diagonal direction. VA LC cell has an excellent contrast ratio in the normal direction due to the no phase-retardation. However, change of the phase-retardation occurs in all directions, which causes the light leakage and deteriorates the characteristics of the dark state. We designed the LC cell structure composed of multiple combinations with two A-plates and two C-plates in order to achieve wide viewing property on the Poincare sphere. From calculations, we show that the proposed structure can improve the viewing angle characteristics by compensating for the light leakage in all directions.

Detection of Leakage Point via Frequency Analysis of a Pipeline Flow

  • Kim, Sanghyun;Wansuk Yoo;Injoon Kang
    • Journal of Mechanical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.232-238
    • /
    • 2001
  • Fast Fourier Transformation is employed to convert the head variation of a pipeline in the time domain to the amplitude of the frequency domain. Applying method of characteristics to a pipeline provides a significant frequency range for a surge introduced from the valve modulation. Inverse Fast Fourier Transformation and a Finite Impulse Response Filter can be used to remove any possible noise existing from the significant frequency range of an unsteady condition. A filtered signal shows higher potential for the inverse calculation of leakage detection than the noise-added signal does. The respective performances of Inverse Fast Fourier Transformation and a Finite Impulse Response Filter are compared in terms of leakage detection capability. Characteristics of the frequency range for multiple leakages were investigated to validate the effectiveness of the noise control method in the frequency domain.

  • PDF

고압 다단 펌프 시일의 누설 및 동특성에 관한 연구 (Leakage and Dynamic Characteristics of High Pressure Multi-Stage Pump Seals)

  • 곽현덕;이용복;김창호;이봉주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.744-749
    • /
    • 2001
  • As related to rotordynamics, dynamic characteristics of the wear ring seal in high pressure multi-stage pump is calculated in the cases of labyrinth, damper and helically grooved types. The. results show that the labyrinth seal type has superior performance in the view point of leakage. However, in terms of rotordynamics view point, the damper seal type gains acceptable separate margin in critical speed range, while it has slightly inferior leakage performance compared to labyrinth seal type.

  • PDF

외부환경 변화에 따른 배전용 피뢰기의 전기적 특성 (Electrical properties of 18kV ZnO surge arrester according to the variation of surrounding conditions)

  • 이복희;이승주;이수봉;김동성;신희경
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 2008
  • This paper describes the electrical characteristics of the ZnO surge arrester according to the variation of surrounding conditions. To investigate the characteristics of degraded ZnO surge arrester, 8/20 [${\mu$s], 2.5 [kA] impulse currents were applied to the ZnO surge arrester to be test. To present the effect of the surrounding con야tions, the leakage currents of ZnO surge arrester were measured to the surrounding temperature and wet conditions. As a result, the increase of ambient temperature causes the increase of resistive leakage current of ZnO surge arrester. Also, in the wet test, the outside leakage current through the ZnO surge arrester housing is much larger than the intrinsic leakage current.

  • PDF