• Title/Summary/Keyword: Leakage calculation

Search Result 152, Processing Time 0.031 seconds

One-step Monte Carlo global homogenization based on RMC code

  • Pan, Qingquan;Wang, Kan
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1209-1217
    • /
    • 2019
  • Due to the limitation of the computers, the conventional homogenization method is based on many assumptions and approximations, and some tough problems such as energy spectrum and boundary condition are faced. To deal with those problems, the Monte Carlo global homogenization is adopted. The Reactor Monte Carlo code RMC is used to study the global homogenization method, and the one-step global homogenization method is proposed. The superimposed mesh geometry is also used to divide the physical models, leading to better geometric flexibility. A set of multigroup homogenization cross sections is online generated for each mesh under the real neutron energy spectrum and boundary condition, the cross sections are adjusted by the superhomogenization method, and no leakage correction is required. During the process of superhomogenization, the author-developed reactor core program NLSP3 is used for global calculation, so the global flux distribution and equivalent homogenization cross sections could be solved simultaneously. Meanwhile, the calculated homogenization cross section could accurately reconstruct the non-homogenization flux distribution and could also be used for fine calculation. This one-step global homogenization method was tested by a PWR assembly and a small reactor model, and the results show the validity.

A Study on the Examination of Explosion Hazardous Area Applying Ventilation and Dilution (환기 및 희석을 적용한 폭발위험장소 검토에 관한 연구)

  • kim, Nam Suk;Lim, Jae Geun;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.27-31
    • /
    • 2018
  • Classification of explosion hazard areas is very important in terms of cost and safety in the workplace handling flammable materials. This is because the radius of the hazardous area determines whether or not the explosion-proof equipment is installed in the electrical machinery and apparatus. From November 6, 2017, KS C IEC-60079-10-1: 2015 will be issued and applied as a new standard. It is important to understand and apply the difference between the existing standard and the new standard. Leakage coefficients and compression factors were added to the leakage calculation formula, and the formula of evaporation pool leakage, application of leakage ball size, and shape of explosion hazard area were applied. The range of the safety factor K has also been changed. Also, in the radius of the hazardous area, the existing standard applies the number of ventilation to the virtual volume, but the revised standard is calculated by using the leakage characteristic value. In this study, we investigated the differences from existing standards in terms of ventilation and dilution and examined the effect on the radius of the hazard area. Comparisons and analyzes were carried out by applying revised standards to workplaces where existing explosion hazard locations were selected. The results showed that even if the ventilation and dilution were successful, the risk radius was not substantially affected.

A Study on the Reasonable Estimation of Consequence of Chemical Release (화학사고 피해영향 범위의 합리적 산정방안에 대한 연구)

  • Cho, Guysun;Lim, Juntaig;Han, Jeongwoo;Baek, Eunsung;Yu, Wonjong;Park, Kyoshik
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.20-28
    • /
    • 2020
  • In this study, the damage impact range in the case of a hydrofluoric acid leak accident was predicted using formula calculation, impact assessment simulations, and CFD simulations, and the results were compared and analyzed with the actual environmental impact report. Formula calculation was performed by using the leak source model and diffusion model. Impact assessment simulation was performed by KORA provided by the Korean Ministry of Environment, ALOHA by the United States Ministry of Environment, and PHAST, which is relatively widely used among commercialization programs, and the STAD-CMM+program for CFD simulation. Was utilized. Considering convenience, speed, acceptability, and economics from the user's perspective, ALOHA and KORA were the most appropriate methods for predicting the impact of hydrofluoric acid leakage. In addition, the results of this study will help to reduce unnecessary regulations in the process of government policy development and optimize the investment in the safety field of the company, effectively utilizing the limited resources of the government and the company.

Estimation of the Relative Risk of the Elderly with Different Evacuation Velocity in a Toxic Gas Leakage Accident (독성물질 누출 시 대피 속도 차이에 따른 고령자의 상대적 위험도 산정)

  • Lee, H.T.;Kwak, J.;Park, J.;Ryu, J.;Lee, J.;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.6
    • /
    • pp.13-21
    • /
    • 2019
  • Leakage accidents in businesses dealing with hazardous chemicals can have a great impact on the workers inside the workplace, as well as residents outside the workplace. In fact, there were cases where hazardous chemicals leaked from many businesses. As a result, the Chemicals Control Act(CCA) was enacted in 2015, the Ministry of Environment introduced an Off-site Risk Assessment(ORA). The purpose of the ORA is to secure safety from the installation of the design of the workplace facilities so that chemical accidents of hazardous chemical handling facilities do not cause human or physical damage outside the workplace. In general, the ORA qualitatively determines where a protected facility is within the scope of the accident scenario. However, elderly who belong to the sensitive group is more sensitive than the general group under the same chemical accident effect, and the extent of the damage is serious. According to data from the Korea National Statistic Office, the number of elderly people is expected to increase steadily. Therefore, a quantitative risk analysis considering the elderly is necessary as a result of a chemical accident. In this study, accident scenarios for 14 locations were set up to perform emergency evacuation due to toxic gas leakage of Cl2(Chlorine) and HF(Hydrogen Fluoride), and the effects of exposure were analyzed based on the evacuation velocity difference of age 20s and 60s. The ALOHA(Areal Locations of Hazardous Atmospheres) program was used to calculate the concentration for assessing the effects. The time of exposure to toxic gas was calculated based on the time it took for the evacuation to run from the start point to the desired point and a methodology was devised that could be applied to the risk calculation. As a result of the study, the relative risk of the elderly, the sensitive group, needs to be determined.

Thermohydrodynamic Lubrication Analysis of High Speed Journal Bearing Considering Variable Density and Specific Heat: Part II - Shaft Misalignment Effect (변화하는 밀도와 비열을 고려한 고속 저어널 베어링의 열유체 윤활해석 II-축 경사도 영향)

  • Chun, Sang-Myung;Jang, Si-Youl
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.305-310
    • /
    • 2001
  • Within some degree of journal misalignment, maximum pressure, maximum temperature, bearing load, friction and side leakage in high-speed journal bearing operation are examined under the condition of variable density and specific heat. The results are compared with the calculation results under the conditions of constant density and specific heat, and variable density and constant specific heat. It is found that the effects of variable density and specific heat on shaft misalignment are significant in determining the load capacity of a journal bearing operating at high speed.

  • PDF

Thermohydrodynamic Lubrication Analysis of High Speed Journal Bearing Considering Variable Density and Specific Heat: Part I - Shaft Speed Effect (변화하는 밀도와 비열을 고려한 고속 저어널 베어링의 열유체 윤활해석 I-축 속고영향)

  • Chun, Sang-Myung;Jang, Si-Youl
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.287-292
    • /
    • 2001
  • Under the condition of variable density and specific heat, maximum pressure, maximum temperature, bearing load, friction and side leakage in high-speed journal bearing operation are examined. The results are compared with the calculation results under the conditions of constant density and specific heat, and variable density and constant specific heat. It is found that the condition of variable density and specific heat play important roles in determining friction and load of journal bearing at high speed operation.

  • PDF

$F_N$-Based Nodal Transport Method in X-Y Geometry

  • Hong, Ser-Gi;Cho, Nam-Zin
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.39-44
    • /
    • 1996
  • A nodal transport method based on the F$_{N}$ method is developed for the transport calculation in x- y geometry and tested for benchmark problems. Using transverse integration, the two-dimensional transport equation is converted to one-dimensional equations for x, y-directions and the one-dimensional equations are integrated over azimuthal angle. With proper approximations for the transverse leakage, the one-dimensional equations are discretized by using the F$_{N}$ method without truncation error. At present, isotropic approximation of the transverse with a quadratic or flat shape in spatial variable is tested.ted.

  • PDF

Calculation of Leakage Inductance in a small size Transformer Winding (소형 변압기 권선의 누설인덕턴스 계산)

  • Chung, Hyun-Koo;Woo, Sung-Hyun;Kim, Young-Bae;Tang, Hyeong-Taek;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.632_633
    • /
    • 2009
  • 변압기의 설계에서 누설인덕턴스는 설계파라미터의 중요한 요소 중에 하나이다. 변압기 권선의 누설자속은 전압강하, 자속의 손실 및 변압기의 효율적 설계 면에서 중요하다. 본 논문은 동심원 권선의 누설임피던스의 계산을 1)수치적인 계산과 2)저장에너지를 이용한 계산 및 3)FEM해석(FLUX2D)을 통하여 누설인덕턴스를 계산하여 각각의 결과를 비교하였다. 누설인덕턴스의 계산 예로 단상 2kVA/220V의 변압기를 모델로 계산 및 해석을 수행하였다.[1][2]

  • PDF

Effect of Lobe Shape Variations on the Performance of Roots-type Supercharger (Roots형 과급기 로브 형상 변화가 성능에 미치는 영향)

  • 김윤제;정찰기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.101-110
    • /
    • 2000
  • A Computer program is developed for creation of a new lobe shaper for Roots-type supercharger. Numerical analyses are preformed for the flowfields in the pocket volumes formed by various lobe shapes. The governing equations for the two-dimensional, turbulent, operational processes in the housing are discretized by the control volume approach that insures the conservative characteristics to be satisfied in the calculation domain, and they are solved by a modified SIMPLE algorithm. Numerical results show that the effects of secondary flow on the leakage flow rate with the Cassini(B) lobe shape is smaller than that of Cassini(A) rotor. But the pocket volume of Cassine(B) lobe is larger than the other lobe shapes.

  • PDF

Internal Flow Characteristic Analysis and Deformation of Foil Considering Slip between Foils (Foil사이의 미끄러짐을 고려한 Foil Bearing변형 및 내부유동특성해석)

  • Lee, S.H.;Won, C.S.;Hur, N.;Jeon, S.B.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.482-487
    • /
    • 2001
  • Leaf type foil bearings have been used successfully in many aerospace applications such as air cycle machines, turbocompressors and turboexpander. These applications are characterized by light loads, constant speeds and low to moderate temperatures. But, as system on start-up or shutdown, sliding contact between the shaft and foil surfaces cause wear. So, in present study, to understand pressure-flow characteristics and deformation of foil bearing, flow/structure interaction analysis was used. and using this method, 2D and 3D calculation was peformed for shape of foil bearing to know circumferential direction flow and leakage flow characteristics of axial direction.

  • PDF