• Title/Summary/Keyword: Leakage accident

Search Result 270, Processing Time 0.02 seconds

Code Analysis of Effect of PHTS Pump Sealing Leakage during Station Blackout at PHWR Plants (중수로 원전 교류전원 완전상실 사고 시 일차측 열수송 펌프 밀봉 누설 영향에 대한 코드 분석)

  • YU, Seon Oh;CHO, Min Ki;LEE, Kyung Won;BAEK, Kyung Lok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.11-21
    • /
    • 2020
  • This study aims to develop and advance the evaluation technology for assessing PHWR safety. For this purpose, the complete loss of AC power or station blackout (SBO) was selected as a target accident scenario and the analysis model to evaluate the plant responses was envisioned into the MARS-KS input model. The model includes the main features of the primary heat transport system with a simplified model for the horizontal fuel channels, the secondary heat transport system including the shell side of steam generators, feedwater and main steam line, and moderator system. A steady state condition was achieved successfully by running the present model to check out the stable convergence of the key parameters. Subsequently, through the SBO transient analyses two cases with and without the coolant leakage via the PHTS pumps were simulated and the behaviors of the major parameters were compared. The sensitivity analysis on the amount of the coolant leakage by varying its flow area was also performed to investigate the effect on the system responses. It is expected that the results of the present study will contribute to upgrading the evaluation technology of the detailed thermal hydraulic analysis on the SBO transient of the operating PHWRs.

Signal processing method based on energy ratio for detecting leakage of SG using EVFM

  • Xu, Wei;Xu, Ke-Jun;Yan, Xiao-Xue;Yu, Xin-Long;Wu, Jian-Ping;Xiong, Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1677-1688
    • /
    • 2020
  • In the sodium-cooled fast reactor, the steam generator is a heat exchange device between sodium and water, which may cause leakage, resulting in a sodium-water reaction accident, which in turn affects the safe operation of the entire nuclear reactor. To this end, the electromagnetic vortex flowmeter is used to detect leakage of the steam generator and its signal processing method is studied in this paper. The hydraulic experiment was carried out by using water instead of liquid sodium, and the sensor output signal of the electromagnetic vortex flowmeter under different gas injection volumes was collected. The bubble noise signal is reflected by the base line of the sensor output signal. According to the relationship between the proportion of the bubble noise signal in the sensor output signal and the gas injection volume, a signal processing method based on the energy ratio calculation is proposed to detect whether the water contains bubbles. The gas injection experiment of liquid sodium was conducted to verify the effectiveness of the signal processing method in the detection of bubbles in sodium, and the minimum detectable leak rate of water in the steam generator was detected to be 0.2 g/s.

Case Analysis of the Harmful Chemical Substances' Spill (유해화학물질 유출의 사례 분석)

  • You, Jisun;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.90-98
    • /
    • 2014
  • Lately accidents of harmful chemical substance in korea were repeatedly replaying. We studied problems and preparation plan in 2008 years~2014 years through analysis cases of harmful chemical substance. Leakage of chemical substance's accident situation shows that leakage in the workplace is the most 10 cases, accounting for 58.6% is the largest proportion in 2009. Leakage according to explosion accounting for 50% (5 cases) in 2004, 25% (4 cases) in 2007 and 33.3% (4 cases) in 2011 has very irregular change. Therefore, A major cause of accidents is lack of safety management. Harmful chemical substance showed various aspects, high residual substance and non-visible characteristic so response and recovery was easy. And the second damage to move a distance causes environment pollution. So a mutual-assistance system and integrated system of related organization have to build and expert of chemical incident response and therapist of chemical substance response have to establish to do efficient and rapid response.

A Study on Conversion Security Control System for Industrial Security (산업보안을 위한 융합보안관제시스템에 관한 연구)

  • Ha, Ok-Hyun
    • Convergence Security Journal
    • /
    • v.9 no.4
    • /
    • pp.1-6
    • /
    • 2009
  • Current paradigm of industrial security is changing into the effective operation and management from simple establishment of security equipments. If the physical security system(entry control system, video security system, etc.) and the IT integrated security control system are conversed, it makes us possible to prevent, disrupt and track afterwards the insider's information leakage through the risk and security management of enterprise. That is, Without the additional expansion of the existing physical security and IT security manpower, the establishment of systematic conversion security management process in a short time is possible and can be expected the effective operation of professional organization system at all times. Now it is needed to build up integrated security management system as an individual technique including the security event collection and integrated management, the post connected tracking management in the case of security accident, the pattern definition and real time observation of information leakage and security violation, the rapid judgement and response/measure to the attempt of information leakage and security violation, the establishment of security policy by stages and systematically and conversion security.

  • PDF

The Impact Analysis of the Leakage Scenario in the Tank of Hydrogen Fuel Cell Vessel (수소연료전지선박의 탱크 내 누출시나리오에 따른 영향분석)

  • Sang-Jin Lim ․;Yoon-Ho Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2023
  • As an alternative to environmental pollution generated from fossil fuels currently in use, research is being actively conducted to use hydrogen that does not cause air pollution. As fire and explosion accidents caused by hydrogen leakage have occurred until recently, research on safety is needed to commercialize hydrogen on ships, which are special environments. In this study, a seasonal alternative scenario for each season and the worst scenario were assumed in the event of a leakage accident while a hydrogen fuel cell propulsion ship equipped with a hydrogen storage tank was navigating at JangSaengPo port in Ulsan. In order to consider environmental variables, the damage impact range was derived through ALOHA and probit analysis based on the annual average weather data for 2021 by the Korea Meteorological Administration and on geographic information data from the National Statistical Office. Radiation showed a wider damage range than that of Overpressure and Flame in both the alternative and worst-case scenarios, and as a result of probit analysis, a fatality rate of 99% was confirmed in all areas.

A Study on the Accident Consequences of High Pressure Pipelines by Applying Reduction Factors (감소인자 적용에 따른 고압가스배관의 사고피해영향에 관한 연구)

  • Lee, Dong Hyuck;Jung, Sang Yong;Ko, Sang Wook;Kim, Min Seop;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.1-6
    • /
    • 2012
  • It becomes a more and more common practice to build facilities bigger and more integrated in an effort to optimize the process within limited resources and spaces. As the capacity of facilities increases, so does the flow rate and pressure. This in turn leads to a high consequence of accident. Not only are these facilities vulnerable to leakage because of their high pressure, but also subsequent fire and explosion can be threatening. For these reasons, there is an urgent need to come up with solutions to assess and minimize the damage from an accident. The Quantitative Risk Assessment(QRA) is one of the most efficient ways to solve problems on pressurized pipelines. The QRA can be re-enforced by applying reduction factors. In this study various types of accidents in a pressurized pipeline were evaluated. The damage from accidents were computed, then. Finally the reduction factors were very effective to decrease consequences of high pressure pipeline accidents.

A Study on the Standard for Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치기준에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • In the last five years, 36 people died and 79 were wounded because of carbon monoxide poisoning accident. A CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread mechanism of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. A CO gas leaked form exhaust tube in a building was the highest concentrated near the ceiling. CO alarm sets installation test confirmed that the alarm sets near the ceiling operated first, and the bottom and middle sets operated after $30{\sim}40$ minutes. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

Analysis of Impact Zone of Quantitative Risk Assessment based on Accident Scenarios by Meteorological Factors (기상요소별 사고 시나리오에 따른 정량적 위험성평가 피해영향범위 분석)

  • Kim, Hyun Sub;Jeon, Byeong Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.685-688
    • /
    • 2017
  • Using ALOHA and PHAST Program, it was modeled assuming the leakage accident scenarios of chlorine which is designated as accident preparation chemical in chemical control act. End-point distances corresponding to ERPG-2 concentrations were calculated while varying annual mean temperature, wind speed, humidity, and atmospheric stability. The calculated endpoint distance values were compared and the correlation with each meteorological factor was analyzed. And we also investigated strengths and weaknesses of ALOHA and PHAST. The results show that ALOHA has little or no correlation with annual average temperature, humidity and it has a large correlation with wind speed and atmospheric stability. In the case of PHAST, the end-point distances were correlated with all the meteorological factors such as average annual temperature, wind speed, humidity, and atmospheric stability, Among them, the effect of atmospheric stability were the largest.

A Study on Improvement of Damage Impact Range Assessment for Field-Based Response Against Chemical Terrorism and Accidents (현장 중심의 화학테러·사고 대응을 위한 피해 영향 범위 평가 개선 방안 연구)

  • Lee, Deok-Jae;Song, Chang Geun
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.127-136
    • /
    • 2020
  • Chemical terrorism and accidents using chemicals are continuously occurring and attempted in and out of the country. In Korea, the National Institute of Chemical Safety affiliated with Ministry of Environment employs the CARIS(Ver. 2018) to assess the damage impact range for field-based response against chemical terrorism and accidents. However, the current version of CARIS can not consider the effects of closed space such as indoor and underground, so it is difficult to provide accurate evaluation results for damage impact range required for field response, on top of the limited information available. The limitations and directions for improvement were studied by comparing and reviewing the evaluation results of the damage impact range obtained by driving CARIS (Ver. 2018) and the domestic and foreign literature. Proposed improvements also included the direction of information provided to residents, including the need to build modeling for special points, such as underground, indoor, etc., and on-site response personnel. It is expected that through the continuous supplementation and correction of CARIS, chemical terrorism and accident response capability system will be advanced further.

A Study on Accident Frequency by Installing Safety Devices in the LPG Heating and Drying Furnace (LPG 가열로 및 건조로의 안전장치 설치에 따른 사고빈도에 관한 연구)

  • Song, Dong-Woo;Kim, Ki-Sung;Kim, Choong-Hee;Lee, Seong-Gueong;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.49-54
    • /
    • 2015
  • The purpose of this study is to assess the risk of depending on the presence or absence of safety device of domestic heating and drying furnaces, by derivation and analysis of accident frequency of safety devices through FTA (Fault Tree Analysis). Installation standards are lacking in Korean for the safety device of LPG heating and drying furnace, which have a risk of explosion due to structure to trap the leaked gas. Four different safety devices were selected on the basis of NFPA and national standards for combustors of other equipment. Effects of frequency reduction in accidents were analyzed before and after installing the safety devices respectively. As a result, a minimal leakage safety device was presented for preventing damages from gas leak of domestic LPG heating and drying furnace.