• Title/Summary/Keyword: Leakage Rates

Search Result 213, Processing Time 0.025 seconds

Measurement from Moving Vehicle Health Screening Outside of The Leakage Dose (이동건강검진차량에서 외부의 누설선량 측정)

  • Han, Beom-Hee;Han, Sang-Hyun;Mo, Eun-Hee;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.192-198
    • /
    • 2015
  • Checked out by the moving vehicle health checks for patients, practitioners, and the increase in radiation dose outside the vehicle, but an investigation into the leakage of radiation can still be negligible. In this study, through experimental results were as follows: Dose that occurs most often where the leak in the right door $1.14{\pm}1.75mR/h$, X-ray generator in terms of proximity to the top $0.65{\pm}1.25mR/h$, X-ray generator and away to the bottom in terms $0.91{\pm}1.25mR/h$, the adjacent rear detector in the upper part $96.98{\pm}158.88mR/h$ dose of the leak appeared in various locations. By measuring position from the rear of the adjacent detector $67.48{\pm}97.03mR/h$ dose had the highest leakage into. Generating device for diagnosis of radiation safety regulations regarding the maximum leakage dose per week, but all met back when it is displayed in the leakage dose Hourly rates do not ignore the leakage radiation dose were measured. Therefore, a mobile health screening in a vehicle outside of the leakage radiation dose to the liver and move on we are not interested twelve barrier leakage radiation dose of defense has a chance to re-evaluate the standards required, and move the vehicle health check using the X-ray increases as the dose per hour, depending on the criteria for choosing the appropriate measures that will require effort.

DC Accelerated Aging Characteristics of Praseodymium-Based ZnO Varistors Doped with $Dy_2O_3$ ($Dy_2O_3$가 첨가된 프라세오디뮴계 ZnO 바리스터의 DC 가속열화특성)

  • Ryu, Jung-Sun;Jung, Young-Chul;Kim, Hyang-Suk;Nahm, Choon-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.78-80
    • /
    • 2001
  • DC accelerating aging characteristics of praseodymium-based ZnO varistors doped with $Dy_2O_3$ were investigated with sintering time. The varistor sintered for 1h exhibited the highest nonlinearity, with a nonlinear exponent of 66.61 and a leakage current of $1.16{\mu}A$, whereas they did not exhibit relatively high stability. The varistor sintered for 2h having nonlinear exponent of 54.81 and leakage current of $2.52{\mu}A$ showed very excellent stability, which the variation rates of varistor voltage, nonlinear exponent, and leakage current are -1.19%, -4.00%, and +75.79% for 2h, under DC accelerated aging stress, such as ($0.85\;V_{1mA}/115^{\circ}C$/24h)+($0.90\;V_{1mA}/120^{\circ}C$/24h)+($0.95\;V_{1mA}/125^{\circ}C$/24h)+($0.95\;V_{1mA}/150^{\circ}C$/24h).

  • PDF

Test Results of the Mechanical Face Seal for a Turbopump

  • Kwak, Hyun-D.;Jeon, Seong-Min;Kim, Jin-Han
    • KSTLE International Journal
    • /
    • v.8 no.1
    • /
    • pp.11-15
    • /
    • 2007
  • The mechanical face seal has been tested in Korea Aerospace Research Institute (KARl) for turbopump applications. In the turbopump under current development, the mechanical face seal is installed between fuel pump and turbine to prevent a mixture of fuel and combustion gas. Generally the mechanical face seal in turbopump is exposed to severe environment because of great rotational speed, high temperature of combustion gas and high level of pressure difference. Thus a series of tests were performed to guarantee the reliability of mechanical face seal by means of simulating the practical operating conditions. The tests were conducted up to 20,000 rpm with pressure difference of 800 kPa and temperature of 620 K In addition several carbon materials for mechanical face seal were conducted to the tests to compare the life time. During the tests, the performance against leakage was monitored and the carbon wear was also measured to estimate the life of a mechanical face seal The results show that the leakage flow rates of mechanical face seal is ignorable compared to an overall flow rate of fuel pump. The carbon material which has the finest wear resistance was found during the tests. Lastly no critical failure of mechanical face seal was found during the tests and the reliability of mechanical face seal for turbopump was successfully proved.

Electrical Properties of SiOCH Thin Films by Annealing (SiOCH 박막의 열처리에 따른 전기적인 특성)

  • Kim, Min-Seok;Hwang, Chang-Su;Kim, Hong-Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.12
    • /
    • pp.1090-1095
    • /
    • 2008
  • The SiOCH films that low dielectric interlayer dielectric materials were deposited on p-type Si(100) substrates through the dissociation of BTMSM precursors with oxygen gas by using PECVD method. BTMSM precursor was introduced with the flow rates from 42 sccm to 60 sccm by 2 sccm step in the constant flow rate of 60 sccm $O_2$. SiOCH thin films were annealed at $450^{\circ}C$ for 30 minutes. The electrical property of SiOCH thin films was studied by MIS, Al/SiOCH/p-Si(100), structure. Annealed samples showed even greater reductions of the maximum capacitance and the dielectric constant of the SiOCH samples, owing to reductions of surface charge density. we confirmed this result with derivative of C-V characteristic, leakage current density. The maximum capacitance and leakage current density were respectively decreased about 4 pF, 60% after annealing. The average of low-k value is approximatly 2.07 after annealing.

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • v.22 no.6
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

Prediction of a Leakage in a Liquid Hydrogen Pump Using a Finite Element Method (유한요소 해석을 이용한 액화수소 펌프 누설량 예측)

  • HYUNSE KIM;YOUNG-BOG HAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.3
    • /
    • pp.292-296
    • /
    • 2023
  • Until recently, ships, automobiles, and drones using hydrogen energy are being actively researched. In addition, stations and facilities for hydrogen supply are being developed widely. Among them, a hydrogen pump is necessary for compressing it and transfer to other stations. The liquid hydrogen pump is operated at very high pressure up to 90 MPa. In our research, a reciprocating plunger pump is studied. Especially, a leakage in a liquid hydrogen pump is predicted using a finite element method. As a result, it was found that leak mass flow rates changed from 0.09 to 2.20 kg/h, when the gaps were given from 2 to 6 ㎛. Thus pump efficiencies were calculated from 99.9 to 97.9%, when the gaps changed from 2 to 6 ㎛. These results are useful for the design of the liquid hydrogen pump.

DC Accelerated Aging Characteristics of ZPCCL-Based Varistor Ceramics (ZPCCL계 바리스터 세라믹스의 DC 가속열화특성)

  • Kim, Hyang-Suk;Nahm, Choon-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.629-633
    • /
    • 2002
  • The degradation behaviour of ZPCCL-based varistor ceramics composed of 97.5 mol%ZnO-0.5 mol% $Pr_6O_{11}-1.0$ mol% $Cr_2O_3-0.5$ mol% $La_2O_3$ was investigated under various DC accelerated aging streses. The varistor ceramics sintered for 1 h exhibited excellent nonlinearity, in which the nonlinear exponent is 81.6 and the leakage current is $0.2{\mu}A$. It was found that this varistor ceramics possess high stability, in which the variation rates of varistor voltage, nonlinear exponent, and leakage current are -1.14%, -3.7%, and 85.0%, respectively, against DC accelerated aging stress. On the contrary, the varistor ceramics sintered for 2 h also exhibited high nonlinearity and stability, but they were bad characteristics, compared with the varistor ceramics sintered for 1 h.

  • PDF

Effect of Sintering Time on Surge Stress Characteristics of ZPCCY-Based Varistors (ZPCCY계 바리스터의 써지 스트레스 특성에 소결시간의 영향)

  • Park, Jong-Ah;Kim, Myung-Jun;Yoo, Dae-Hoon;Nahm, Choon-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.408-411
    • /
    • 2004
  • The electrical stability against surge stress of ZPCCY-based varistors were investigated at different sintering times. Sintering time decreased the varistor voltage and nonlinear exponent from 279.6 to 179.1 and from 52.5 to 24.9, respectively. On the contrary, the leakage current and dielectric dissipation factor increased from 1.2 to 9.8 ${\mu}A$ and from 0.0461 to 0.0651 with increase of sintering time. For all varistors, the variation rates of V-I characteristic parameters against surge stress were affected in order of varistor voltage$\rightarrow$nonlnear exponent$\rightarrow$leakage current. On the whole, the electrical stability against surge stress increased with increasing sintering time. Conclusively, it is assumed that the varistor sintered for 2 h exhibited comparatively good characteristics, in view of overall characteristics.

  • PDF

Numerical Study of The Nozzle-Rotor Axial Gap Effect on the Supersonic Turbine Performance (충동형 초음속 터빈의 노즐-로터 축간극에 따른 성능변화 연구)

  • Jeong, Soo-In;Kim, Kui-Soon;Jeong, Eun-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.160-163
    • /
    • 2010
  • We performed three-dimensional CFD analysis to investigate the effect of the nozzle-rotor axial gap of a partial admission supersonic turbine on the stage performance and the flow field. The computations are conducted for five axial gaps using flow analysis program, $FLUENT^{TM}$. The results show that the axial gap between nozzle and rotor give the effect on the mass flow rates of tip leakage and the flow angle at the rotor outlet.

  • PDF

Electrical and Dielectric Properties, and Accelerated Aging Characteristics of Lanthania Doped Zinc Oxide Varistors

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.4
    • /
    • pp.189-195
    • /
    • 2006
  • The microstructure, electrical and dielectric properties, and stability against DC accelerated aging stress of the varistors, which are composed of quaternary system $ZnO-Pr_6O_{11}CoO-Cr_2O_3-based$ ceramics, were investigated for different $La_2O_3$ contents. The increase of $La_2O_3$ content led to more densified ceramics, whereas abruptly decreased the nonlinear properties by incorporating beyond 1.0mol%. The highest nonlinearity was obtained from 0.5mol% $La_2O_3$, with the nonlinear coefficient of 81.6 and the leakage current of $0.1{\mu}A$. The varistors doped with 0.5mol% $La_2O_3$ exhibited high stability, in which the variation rates of breakdown voltage, nonlinear coefficient, leakage current, dielectric constant, and dissipation factor were -1.1%, -3.7%, +100%, +1.4%, and +8.2%, respectively, for stressing state of $0.95V_{1mA}/150^{\circ}C/24h$.