아크릴로니트릴 누출에 따른 독성, 복사열 및 외부영향에 의한 아파트의 성능위주설계 방안 (Performance Based Design Plan for Apartment that Reflects External Effects from Toxicity and Radiant Heat Due to Acrylonitrile Leakage)

  • 오승주;한상훈;공하성
    • 대한안전경영과학회지
    • /
    • 제26권2호
    • /
    • pp.65-77
    • /
    • 2024
  • This study aims to present a performance based design for apartments through evacuation safety assessment and damage impact assessment due to acrylonitrile leakage. In the evacuation safety evaluation, ASET was analyzed as 25 min or more and 60 min or less when the ventilation rate was once per hour, and RSET was 22.6 min. Evacuation safety is satisfied when the number of ventilation per hour is less than 1, so it is necessary to design the number of ventilation to be 1 or less. In the damage impact assessment, the 0% structural collapse rate due to overpressure was measured to be between 71m and 90m, and the 0% fatality rate due to radiant heat was measured to be between 136m and 353m. Therefore, maintain a safe distance of 353m or more.

중소기업 기술보호지원제도에 대한 이용자와 정책담당자의 인식차이 분석 (Perception differences between users and policy-makers on technology protection support system for small and medium-sized businesses)

  • 박상훈;조남욱
    • 디지털산업정보학회논문지
    • /
    • 제13권1호
    • /
    • pp.37-48
    • /
    • 2017
  • As the risk of technical leakage is increasing, technology protection support systems for small and medium-sized businesses have gained attention. This paper analyzed the perception gap of the user and policy-maker regarding technology protection support systems. First, to identify key elements of technology protection support systems and construct measurement factors, interviews with experts are conducted. Then, surveys are conducted to analyze the perception differences between the users and policy-makers. Factor analysis and ANOVA have been utilized to analyze survey results. The result shows that the perception gaps exist in the following areas: management system, cost reduction, copyright protection, customer satisfaction, leakage prevention, and awareness. To enhance the effectiveness of technology protection support systems, this paper suggests technology protection support systems should be customized in terms of the company's size and type of busines.

해안매립지에서의 추적자시험 및 수위변화특성 연구

  • 이진용;황대규;이명재;최예권;김정우;이강근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.221-224
    • /
    • 2002
  • To demonstrate prevention of the leachate leakage out of the landfill with creating inward hydraulic gradient, a tracer test and continuous waterlevel monitoring at the Inside and outside of the barrier wall of a costal landfill were peformed. When the tracers were injected into the well outside of the vertical wall system with high water level, then they were detected at the well inside of the system with low water level. Furthermore the lowered water level at the inside of the landfill than that at the outside prevented leachate leakage out of the landfill. This study reports results of the tracer test and waterlevel monitoring.

  • PDF

점착.팽창성 유연형 도막방수재를 이용한 콘크리트 구조물의 누수방지 기술에 관한 연구 (A Study on Technology for Leakage Prevention of Concrete Construction by Flexible Type Waterproofing with Adhesive and Swelling Properties)

  • 최성민;김종복;장혁수;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.768-773
    • /
    • 1999
  • This study of concrete movement confronting a scope inspects the problems about the waterproofing method and leakage/repairment at present and research the mechanism with the variety of applying examples introducing adhesion and inflation using the flexible type of waterproofing and repairement and the subsititution method developed with polymer resign composite. The polymer resign transmited into adhesion or inflation materials under wet environment absorbs adjoining moisture, wraps impurities of concrete surface, get the waterproofing layer and concrete surface adhere toughly, reorganize the impaired waterproofing layer and get over the detachment of it from concrete surface.

  • PDF

발전용 발전기 여자설비의 오일 오염방지 (Prevention of Oil Contamination in the Excitation System of a Power Plant Generator)

  • 최재규;유호선;문승재
    • 플랜트 저널
    • /
    • 제7권2호
    • /
    • pp.30-38
    • /
    • 2011
  • The purpose of this paper is to review the understanding of pollution causes in the excitation system and how to solve the problem. The cause of the problem was in-leakage of bearing lubricant oil through the gap between rotor and outer in the air deflector, which was triggered by a negative pressure with respect to the operation of a collector ring fan in the collector house. In order to prevent exciting current transmission equipment pollutant, the reduction of the negative gage pressure of the inside of collector house is required. The protection in-leakage of bearing lubricant oil through the gap between rotor and outer of the air deflector are necessary. The reduction of the inside diameter of air deflector and the expansion of inlet filter of collector house are inevitable.

  • PDF

지온탐사에 의한 저수지 제방의 누수 조사 (Delineation of water seepage in a reservoir embankment from ground temperature measurements)

  • 박삼규
    • 자원환경지질
    • /
    • 제32권2호
    • /
    • pp.169-175
    • /
    • 1999
  • The water leakage of reservoir embankment usually occurs through water vein, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disater prevention and embankment protection. This paper presents survey results of one-meter-depth ground temperature and multi-point temperature logging in an embankment in Japan to delineate water veins and permeable formations. Four water veins have been predicted in the embankment by comparing measured one-meter-depth ground temperatures with the background ones which have no effect of water vein. The multi-point temperature logging was carried out in the borehole drilled at one of the predicted water veins. Depth and thickness of the permeable formation in the borehole can be determined from temperature restoration ratios with elapsed time. From these results we can find that the water leakage of reservoir embankment mainly occurs in sandy soil formation in the embankment.

  • PDF

국방 정보시스템 환경에서 정보유출 방지를 위한 보안성이 강화된 문서 DRM 설계에 관한 연구 (A Study on An Architecture of the Security improved Document DRM for preventing Information Leakage in Military Information System Environment)

  • 엄정호
    • 디지털산업정보학회논문지
    • /
    • 제7권1호
    • /
    • pp.41-49
    • /
    • 2011
  • We designed a security improved document DRM for protecting document based military information which is transmitted in the military information system environment. The user should be could not access document which not related to his/her role and duty, and must view the only document appropriate for his/her role and security level according to the security level of document. We improved the security of document DRM by adding to the access control module in DRM server. Our system allows operation mode authorizations for the document, considering the user's role & security level and the security level of document. And it prevents indiscriminate access to the document and damage the confidentiality and integrity of information.

덕트누기시험기용 풍량측정 오리피스의 최적위치 선정에 관한 연구 (A Study on the Optimal Orifice Location for Air flow Measurement in an Air Duct Leakage Tester)

  • 이승철
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.186-191
    • /
    • 2006
  • In this study, five experiments were carried out, with an orifice located downstream of a fan in case I where upstream duct length is 6 D, and that in the downstream is 4 D and different downstream distance to the fan in the rest, so as to determine the optimal location of the orifice and reduce the duct length of airflow measurement device. The resulting flow rate-pressure drop correlations were found to satisfy the limitation of SMACNA standard, which specified an error of $\pm7.5\%$ based on the real flow rate. Also, the best one of five. cases was achieved with the orifice located midway of the orifice duct four times its diameter long.

접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구 (A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults)

  • 최정규;곽동걸;이승철;이봉섭;박영직
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.

  • PDF

FinTech를 위한 다자간 컴퓨팅 암호기술 (Secure Multi-Party Computation of Technology FinTech)

  • 박찬길;최영화;이철희
    • 디지털산업정보학회논문지
    • /
    • 제15권1호
    • /
    • pp.61-66
    • /
    • 2019
  • FinTech has expanded to the extent that not only businesses but almost everyone can feel the impact. The spread of the scope of use has introduced a variety of new financial services that are changing the way we live. In these environments, it is important to develop reliable security measures to protect against cyber attacks. The number of mobile financial transactions in the financial sector is also increasing, making security vulnerable. In this study, we studied security through mutual authentication method that can safely handle financial security and focused on FinTech's security processing through multi-party mutual authentication method that strongly prevents leakage of information even in the event of continuous and sophisticated attacks.