• Title/Summary/Keyword: Leakage Loss

Search Result 622, Processing Time 0.034 seconds

A Study on the Effects of Sodium Salicylate on the Spiral Ganglion Cells (살리실산 나트륨이 백서 와우의 나선신경절에 미치는 영향에 대한 연구)

  • Lee, Byung-Lan
    • Applied Microscopy
    • /
    • v.18 no.1
    • /
    • pp.92-102
    • /
    • 1988
  • The ototoxic effects of salicylate on the ultrastructure of spiral ganglion cells were examined. Sodium salicylate($50{\sim}60\/kg$ body weight, once a day for 7 days) were injected subcutaneously to $5{\sim}6$ week-old fifteen Sprague-Dawley rats. Animals were sacrificed 24 hours (group 1), 6 weeks (group 2) or 10 weeks (group 3) after the last injection. In group 1 animals, distention of membranous cisternae was found in the cytoplasm of ganglion cells, satellite cells and Schwann cells in which enlargement or multicystic cytosome formation of the mitochondria were shown. In group 2 animals, membranous cisternae became larger or fused to form larger vacuoles or cysts. Shrinkage of spiral ganglion cell cytoplasm and loosening of myelin sheath were seen. In group 3 animals, extensive swelling or loss of nerve fibers were shown along with the folding or partial loss of myelin sheath which caused leakage of ganglion cell cytoplasm. It was concluded that the ototoxicity of salicy-late caused the ultrastructral changes of the spiral ganglion cells which became more severe in group 2 and 3 animals. The possibility of retrograde degeneration following the sensory cell changes was suggested.

  • PDF

Proposal of the Development Direction on the Special Act on Underground Safety Management for Preparation of the Proactive Underground Safety Management System (선제적 지하안전관리체계 마련을 위한 지하안전관리에 관한 특별법의 발전방향 제시)

  • Han, Yushik
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.7
    • /
    • pp.17-27
    • /
    • 2018
  • Sinkholes have occurred in various places around the world and concerns about public safety have been raised in recent years. Particularly, a ground subsidence may occur due to a variety of conditions when developing underground spaces. Ground subsidence refers to the sinking of the Earth's surface caused by the loss of the soil constituting ground due to a certain artificial cause in the ground. Ground subsidence is induced by artificial causes such as the leakage of water supply/sewage pipes and groundwater disturbance, and it is different from a sinkhole, where the sinking of the Earth's surface is induced by the cavity formed due to the melting of limestone in the ground with limestone bedrock. In recent underground development in the urban areas of Korea, damages to surrounding buildings have frequently led to many difficulties with civil complaints and compensation issues, and the collapse of some buildings has resulted in the loss of lives and property. Accordingly, the central government has legislated the Special Act on Underground Safety Management, which will take effect from January 1, 2018. This law specifies an underground safety management system for securing underground safety, under which underground safety impact assessment is performed for projects involving underground excavation work that exceeds a certain size, and safety inspection is regularly performed for underground facilities and the surrounding ground. In this study, the contents of the special act on underground safety management are reviewed, and the direction of development of underground safety policy for preparing preemptive underground safety management preparation and response system is suggested.

High-Efficiency CMOS Power Amplifier using Low-Loss PCB Balun with Second Harmonic Impedance Matching (2차 고조파 정합 네트워크를 포함하는 저손실 PCB 발룬을 이용한 고효율 CMOS 전력증폭기)

  • Kim, Hyungyu;Lim, Wonseob;Kang, Hyunuk;Lee, Wooseok;Oh, Sungjae;Oh, Hansik;Yang, Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.104-110
    • /
    • 2019
  • In this paper, a complementary metal oxide semiconductor(CMOS) power amplifier(PA) integrated circuit operating in the 900 MHz band for long-term evolution(LTE) communication systems is presented. The output matching network based on a transformer was implemented on a printed circuit board for low loss. Simultaneously, to achieve high efficiency of the PA, the second harmonic impedances are controlled. The CMOS PA was fabricated using a $0.18{\mu}m$ CMOS process and measured using an LTE uplink signal with a bandwidth of 10 MHz and peak to average power ratio of 7.2 dB for verification. The implemented CMOS PA module exhibits a power gain of 24.4 dB, power-added efficiency of 34.2%, and an adjacent channel leakage ratio of -30.1 dBc at an average output power level of 24.3 dBm.

Quality and Physiological Characteristics of Pinus densiflora Seeds Under Different Storage Periods and Temperatures (장기 저장과 저장 온도에 따른 소나무 종자 품질과 생리적 특성)

  • Gu, Da-Eun;Ku, Ja-Jung;Han, Sim-Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.3
    • /
    • pp.418-427
    • /
    • 2022
  • Our aim was to evaluate the quality of pine seeds after long-term storage and to analyze the correlation between germination and physiological characteristics. Therefore, we investigated the germination and physiological characteristics of seeds stored for different periods and storage temperatures. Pine seeds lost little viability and vigor after 12 years of storage at 4℃; it is even possible to prolong the storage period at -18℃. The deterioration process operating through long-term storage was characterized by a loss of seed vigor before a loss in seed viability. Electrical conductivity of the seed leachate was significantly higher in seeds that completely lost their viability, and was also found to be significantly correlated with the germination percentage, T50, mean germination time, and germination speed. Among the minerals leaked to the leachate, K had the highest concentration, followed by Na, Ca, Cu, Mg, and Fe, while Mn and Zn were not detected. Concentrations of K, Ca, Cu, Mg, and Fe in the leachate differed significantly by treatment, and in the cases of K, Ca, Cu, Na, and Mg, we observed large differences in the leachate between the seeds that were collected in 2003 and those collected in other years.. Germination percentage was significantly negatively correlated to the concentrations of Ca, Cu, K, Mg, and Na. The coefficient of uniformity of germination was significantly negatively correlated to Cu concentration. The other germination characteristics were not significantly correlated with the mineral concentration. Therefore, the mineral concentrations of pine seed leachate were not reliable indicators of seed deterioration when the differences in quality between seed lots were small. However, electrical conductivity could be an indicator of seed viability and vigor of pine seeds under long-term storage.

Clinical Outcomes of Corrective Surgical Treatment for Esophageal Cancer (식도암의 외과적 근치 절제술에 대한 임상적 고찰)

  • Ryu Se Min;Jo Won Min;Mok Young Jae;Kim Hyun Koo;Cho Yang Hyun;Sohn Young-sang;Kim Hark Jei;Choi Young Ho
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.157-163
    • /
    • 2005
  • Background: Clinical outcomes of esophageal cancer have not been satisfactory in spite of the development of surgical skills and protocols of adjuvant therapy. We analyzed the results of corrective surgical patients for esophageal cancer from January 1992 to July 2002. Material and Method: Among 129 patients with esophageal cancer, this study was performed in 68 patients who received corrective surgery. The ratio of sex was 59 : 9 (male : female) and mean age was $61.07\pm7.36$ years old. Chief complaints of this patients were dysphagia, epigastric pain and weight loss, etc. The locations of esophageal cancer were 4 in upper esophagus, 36 in middle, 20 in lower, 8 in esophagogastric junction. 60 patients had squamous cell cancer and 7 had adenocarcinoma, and 1 had malignant melanoma. Five patients had neoadjuvant chemotherapy. Result: The postoperative stage I, IIA, IIB, III, IV patients were 7, 25, 12, 17 and 7, respectively. The conduit for replacement of esophagus were stomach (62 patients) and colon (6 patients). The neck anastomosis was performed in 28 patients and intrathoracic anastomosis in 40 patients. The technique of anastomosis were hand sewing method (44 patients) and stapling method (24 patients). One of the early complications was anastomosis leakage (3 patients) which had only radiologic leakage that recovered spontaneously. The anastomosis technique had no correlation with postoperative leakage, which stapling method (2 patients) and hand sewing method (1 patient). There were 3 respiratory failures, 6 pneumonia, 1 fulminant hepatitis, 1 bleeding and 1 sepsis. The 2 early postoperative deaths were fulminant hepatitis and sepsis. Among 68 patients, 23 patients had postoperative adjuvant therapy and 55 paitents were followed up. The follow up period was $23.73\pm22.18$ months ($1\~76$ month). There were 5 patients in stage I, 21 in stage 2A, 9 in stage IIB, 15 in stage III and 5 in stage IV. The 1, 3, 5 year survival rates of the patients who could be followed up completely was $58.43\pm6.5\%,\;35.48\pm7.5\%\;and\;18.81\pm7.7\%$, respectively. Statistical analysis showed that long-term survival difference was associated with a stage, T stage, and N stage (p<0.05) but not associated with histology, sex, anastomosis location, tumor location, and pre and postoperative adjuvant therapy. Conclusion: The early diagnosis, aggressive operative resection, and adequate postoperative treatment may have contributed to the observed increase in survival for esophageal cancer patients.

Effect of Several Treatments on Chilling Injury of Paprika Fruits during Low Temperature Storage (몇 가지 처리가 파프리카 과실의 저온장해에 미치는 영향)

  • Choi, In-Lee;Lee, Yong Beom;Kim, Il Seop;Baek, Jun Pill;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.427-431
    • /
    • 2013
  • Paprika fruits should be stored and distributed at above $7^{\circ}C$ to prevent chilling injury but the small amount of paprika that transports with other horticultural products in refrigerated container by ship usually stored less than $5^{\circ}C$ for other products. In this case, paprika fruits cannot help exposing chilling temperature, so that the paprika must be lost marketable value during a long period of transfer. This study was conducted to compare the alleviated effects of high $CO_2$ treatment (passive MAP), heat (hot water dipping), and UVc treatment on chilling injury of paprika fruits due to low temperature storage, and also to decide if these treatments can be used for transporting under $5^{\circ}C$. After each treatment the paprika were put in the low temperature storage ($4^{\circ}C$) for 20 days and afterwards change the in room temperature ($20^{\circ}C$) for 5 days. The fresh weight loss of all the treatments except the high $CO_2$ treatment showed around 7~12% after 25 days of storage and the ethylene concentration showed periodical increases and decreases as around 3 ${\mu}l/l$. The $CO_2$ concentration was rapidly increased 33% carbon dioxide in high $CO_2$ treatment during room temperature storage after cold storage for 20 days. The firmness which is key quality characteristics during storage and is decreasing caused by chilling injury was not significantly different among all treatments. However, the firmness of stored paprika was maintained highest in the treated with hot water dipping. Therefore, HWD and UVc treatment that showed 60% of electrolyte leakage in the $4^{\circ}C$ control (chilling injury control) and similar level with the $7^{\circ}C$ control (non-chilling injury control) would be effective to alleviate chilling injury in the stored paprika.

Characteristics of the ( Pb, La ) $TiO_3$ Thin Films with Pb/La Compositions (Pb/La 조성에 따른 ( Pb, La ) $TiO_3$ 박막의 특성 변화)

  • Kang, Seong-Jun;Joung, Yang-Hee;Yoon, Yung-Sup
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.29-37
    • /
    • 1999
  • In this study, we have prepared PLT thin films having various La concentrations by using sol-gel method and studied on the effect of La concentration on the electrical properties of PLT thin films. As the La concentration increases from 5mol% to 28mol%, the dielectric constant at 10kHz increases from 428 to 761, while the loss tangent decreases from 0.063 to 0.024. Also, the leakage current density at 150kV/cm has a tendency to decrease from 6.96${\mu}A/cm^2$ to 0.79${\mu}A/cm^2$. In the result of hysteresis loops of PLT thin films, the remanent polariation and the coercive field decrease from 9.55${\mu}C/cm^2$ to 1.10${\mu}C/cm^2$ and from 46.4kV/cm to 13.7kV/cm, respectively. With the result of the fatigue test on the PLT thin films, we have found that the fatigue properties are improved remarkably as the La concentration increases from 5 mol% to 28mol%. In particular, the PLT28) has paraelectric phase and its charge storage clensity and leakage current density at 5V are 134fC/${\mu}cm^2$ and 1.01${\mu}A/cm^2$, respectively. The remanent polarization and coercive field of the PLT(10) film are 6.96${\mu}C/cm^2$ and 40.2kV/cm, respectively. After applying of $10^9$ square pulses with ${\pm}5V$, the remanent polarilzation of the PLT(10) film decreases about 20% from the initial state. In the results, we conclude that the 10mol% and the 28mol% La doped PLT thin films are very suitable for the capacitor dielectrics of new generation of DRAM and NVFRAM respecitively.

  • PDF

A Study on the Reliability Analysis and Risk Assessment of Liquefied Natural Gas Supply Utilities (천연가스 공급설비에 대한 기기신뢰도 분석 및 위험성 평가)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.8-20
    • /
    • 2003
  • Natural gas has been supplied through underground pipelines and valve stations as a new city gas in Seoul. In contrast to its handiness the natural gas has very substantial hazards due to fires and explosions occurring from careless treatments or malfunctions of the transporting system. The main objectives of this study are to identify major hazards and to perform risk assessments after assessing reliabilities of the composing units in dealing with typical pipeline networks. there-fore two method, fault tree analysis ;1nd event tree analysis, are used here. Random valve stations are selected and considered its situation in location. The value of small leakage, large rupture, and no supply of liquefied natural gas is estimated as that of top event. By this calculation the values of small leakage are 3.29 in I)C valve station, 1.41 in DS valve station, those of large rup-lure are $1.90Times10_{-2}$ in DC valve station, $2.32$\times$10^{-2}$ in DS valve station, and those of no supply of LNG to civil gas company are $2.33$\times$10 ^{-2}$ , $2.89$\times$10^{-2}$ in each valve station. And through minimal cut set we can find the parts that is important and should be more important in overall system. In DC valve station one line must be added between basic event 26,27 because the potential hazard of these parts is the highest value. If it is added the failure rate of no supply of LNG is reduced to one fourth. In DS valve station the failure rate of basic event 4 is 92eye of no supply of LNG. Therefore if the portion of this part is reduced (one line added) the total failure rate can be decreased to one tenth. This analytical study on the risk assessment is very useful to prepare emergency actions or procedures in case of gas accidents around underground pipeline networks and to establish a resolute gas safety management system for loss prevention in Seoul metropolitan area.

Effect of Zr/Ti Concentration in the PLZT(10/y/z) Thin Films From the Aspect of NVFRAM Application (비휘발성 메모리소자로의 응용의 관점에서 PLZT(10/y/z) 박막에서의 Zr/Ti 농도변화 효과)

  • Kim, Seong-Jin;Gang, Seong-Jun;Yun, Yeong-Seop
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.5
    • /
    • pp.313-322
    • /
    • 2001
  • The effects of Zr/Ti concentration ratio in PLZT (10/y/z) thin films prepared by sol-gel method are investigated for the NVFRAM application. Rosette and pyrochlore phase are observed in PLZT (10/40/60) thin film and the (100) orientation, the grain size, and the surface roughness of PLZT thin films increase due to the increase of Ti amount in Zr/Ti concentration ratio. As Ti amount of Zr/Ti concentration ratio increases, the dielectric constants at 10KHz decrease from 600 to 400, while the loss tangents increase from 0.028 to 0.053 and the leakage current densities at 170 kY/cm decrease from 1.64$\times$10$^{-6}$ to 1.26$\times$10$^{-7}$ A/$\textrm{cm}^2$. In the results of hysteresis loops measured at $\pm$ 170 ㎸/cm, the remanent polarization and the coercive field increase from 6.62 to 12.86 $\mu$C/$\textrm{cm}^2$ and from 32.15 to 56.45 ㎸/cm, respectively, according to the change from 40/60 to 0/100 in Zr/Ti concentration ratio. Fatigue and retention properties also improve much as the Zr/Ti concentration ratio change from 40/60 to 0/100. After applying 10$^{9}$ square pulses with $\pm$5V, the remanent polarization of the PLZT (10/40/60) thin film decreases 50% from the initial state while that of the PLZT (10/0/100) thin film decreases 30%. In the results of retention measurements of 10$^{5}$ s, the remanent polarization of the PLZT (10/0/100) thin film decreases only 11% from the initial state, while that of the PLZT (10/40/60) thin film decreases 40%.

  • PDF

AN EXPERIMENTAL STUDY ON THE VASCULAR CHANGES OF RAT MOLAR PERIODONTAL LIGAMENT FOLLOWING ORTHODONTIC TOOTH MOVEMENT USING VASCULAR CORROSION CASTING METHOD (백서구치의 실험적 치아이동시 치근막 혈관변화에 관한 혈관주형법을 이용한 연구)

  • Lim, Yong-Kyu;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.24 no.1 s.44
    • /
    • pp.37-62
    • /
    • 1994
  • This study was undertaken to investigate the three dimensional vascular changes of periodontal ligament following orthodontic tooth movement. Experimental tooth movement was carried out in 96 Sprague-Dawley rats with the weight of 250g. They were divided into four experimental groups (each 24 rats). The left maxillary first molar was moved mesially with 25g force in group I, and with 75g force in group II. Each three animals were sacrificed after 1, 6, 12, 24 hours, and 3, 7, 14, 21 days. In group III, 25g mesial force was applied for 3 days, and in group IV, 75g mesial force was applied for 3 days. Then the appliances were removed, and each three animals were sacrificed after 1, 6, 12, 24 hours, and 3, 7, 14, 21 days from removal of appliance. The contralateral molars were used for control group. Casting media was injected via left ventricle and polymerized in warm water. After corrosion of surrounding soft tissue, three dimensional vascular changes were examined using scanning electron microscopy. The findings of this study were as follows: 1. Pressure side of group I and II showed degenerative vascular changes such as vascular compression, reduction of vasculature, leakage of casting media. But, regenerative changes were dominant after 7 days of tooth movement. Although the degenerative vascular changes were more severe in group II, which was exposed to heavy force, the timing of these changes was not different between two groups. 2. Periodontal vasculature was reestablished by the growth of new capillaries and their differentiation and union from the remaining periodontal vessels and vessels of alveolar bone marrow. Although vascular regeneration was more rapid in group I, which was exposed to light force, the vasculature was not fully normalized in both groups even after 21 days. 3. There was no remarkable changes in tension side of group I and II, but looping of capillary, new capillary growth, dilation of vessels, redirection of vessels in the direction of tensile force were occurred. 4. In pressure side of group III and IV, in which appliance was removed after 3 days of orthodontic force, bone resorption was continued even after removal of appliance. Regeneration of vasculature was initiated after 1-6 hours, and it was more rapid in group III than group IV. In both groups, the vasculature was not fully normalized even after 21 days. 5. After removal of appliance, tension side of group III and IV showed vascular compression and loss of vasculature.

  • PDF