• 제목/요약/키워드: Leakage Error

검색결과 167건 처리시간 0.027초

오리피스 유량계에서 게이지라인 누설에 의한 계량오차 (The Measurement Error owing to Leakage of Gaugeline in Orifice Flowmeter)

  • 이철구;하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.143-148
    • /
    • 2003
  • This study was experimentally performed in order to estimate the errors due to the leakage of transmitter gaugelines in the orifice flow meter for natural gas. It would be a serious problem in safety if a large quantity of leak was occurred at the tubes or fittings like valve. But in most cases the safety problems might be rarely happened because the gas leak detectors could be operated in advance and the various kinds of inspection would be also fulfilled periodically. If the leakage was occurred continuously with an undetectable amount at the gaugelines for measuring the pressure or the differential pressure(DP), the amount of leakage might be an error or an unaccounted flow(UAE). In addition if the measuring value of pressure or DP were affected by the leakage, it might also be a measurement error. The experiments were performed to estimate the amount of leakage and to check the DP changes if it exited. First, through the measurement of the air pressure changes in the airtight container connected to a transmitter with gaugelines as the time passed, the amount of leakage causing from the fittings of gaugelines was roughly estimated. As changing the leak position of the gaugeline, the leak was intentionally made to break out. The variance of DP was checked as controlling the extent of leakage and compared to no leak conditions. Consequently, under the normal maintenance conditions, the result represented that the amount of leakage causing from the gaugelines was insignificant and also the DP changes on leakage conditions were too small to cause the errors of measurements.

  • PDF

음향 인텐시티의 누설오차 개선에 관한 기초적 연구 (A Basic Study on the Improvement of Leakage Error of the Acoustic Intensity)

  • 정의봉;정호경;안세진;윤상돈
    • 한국음향학회지
    • /
    • 제22권5호
    • /
    • pp.345-350
    • /
    • 2003
  • 음향 인텐시티는 근접한 두 개의 마이크로폰으로부터 얻어지는 음압의 크로스스펙트럼으로부터 얻어진다. 크로스스펙트럼은 이산 푸리에 변환에 의해 얻어지는데 이는 기록시간과 신호의 주기가 일반적으로 일치하지 않기 때문에 누설오차의 발생을 피할 수 없다. 그러므로 기존의 FFT 해석기로부터 얻어지는 음향 인텐시티는 왜곡된 값을 보여준다. 본 논문에서는 단일주파수를 가지는 조화 신호에 누설오차가 발생한 경우 푸리에 변환된 데이터를 규정한다. 또한 왜곡된 데이터로부터 누설오차의 영향을 제거하는 방법을 제안한다. 제안한 방법의 타당성을 보이기 위해 몇 가지 수치해석 예를 보인다.

디지털 푸리에 변환에서 누설오차의 개선 (The Improvement of Leakage Error in Digital courier Transform)

  • 정의봉;안세진;장호엽;장진혁
    • 소음진동
    • /
    • 제11권3호
    • /
    • pp.455-460
    • /
    • 2001
  • An exact spectrum wish no leakage error could be obtained when the period of the signal coincides perfectly with the record length. However, the record length will be determined regardless of the period of signal. The Leakage error due to this problem will gibe a distorted spectrum. In the conventional research, the method was proposed to estimate the three parameters, frequency, amplitude and phase angle, from the spectrum data for anundamped sinusoidal signal. In this paper, some techniques are proposed to estimate frequency, amplitude and damping ratios from the frequency response functions for damped signals. The validation of the proposed techniques is verified by several numerical examples.

  • PDF

누설오차의 영향을 고려한 음향 인텐시티의 추정 (Sound Intensity Estimation with the Effect of Leakage Error from the Contaminated Data)

  • 안세진;정의봉;정호경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1189-1194
    • /
    • 2002
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent micrphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional r]n analyzer will show distorted value. In this paper the expression of the Fourier transformed data of a harmonic signal is formulated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

단일 주파수를 갖는 음향 인텐시티의 누설오차 개선 (Leakage Error Improvement of the Intensity with a single freqency)

  • 정의봉;안세진;정호경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1156-1161
    • /
    • 2001
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed date of a harmonic signal with a single frequency is formated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

영상을 이용한 누설탐지에서 카메라 진동 오차 보정 (Correction of Error due to Camera Vibrating During Detecting Steam Leakage by Using Image)

  • 최영철;전형섭;손기성;박종원
    • 한국소음진동공학회논문집
    • /
    • 제24권10호
    • /
    • pp.795-801
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

지역난방배관의 누수감지 신뢰성 향상에 관한 연구 (A Study on the Improvement of Water-Leakage Detection Reliability in Local Heating System)

  • 신춘식;안영주;변기식
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.66-72
    • /
    • 1999
  • Local heating transportation pipe has sensor and return lines to detect water-leakage. There are impulse and resistance comparison measurement types for a water-leakage detection. The impulse type shows large detection error within a measurement range. Since the resistance comparison type can find a comparative accurate single water-leakage point in the measurement range of heating pipe, it has been used to detect water-leakages these days. However if the multi water-leakages are happened in the measurement range of transportation pipe. the resistance comparison type shows a detection error point by the parallel resistance between a detection sensor line and ground. But the detection error will be minimized by the divided transportation pipe loops. In this research, it suggests the design of remote controlled detection system which can divide a large pipe loop and a possible single water-leakage measurement process in each divided loops.

  • PDF

고집적 DRAM 셀에 대한 소프트 에러율 (Soft Error Rate for High Density DRAM Cell)

  • 이경호;신형순
    • 대한전자공학회논문지SD
    • /
    • 제38권2호
    • /
    • pp.87-94
    • /
    • 2001
  • DRAM에서 셀 캐패시터의 누설 전류 영향을 고려하여 소프트 에러율을 예측하였다. DRAM의 동작 과정에서 누설 전류의 영향으로 셀 캐패시터는 전하량이 감소하고, 이에 따른 소프트 에러율을 DRAM의 각 동작 모드에 대하여 계산하였다. 누설 전류가 작을 경우에는 /bit mode가 소프트 에러에 취약했지만, 누설전류가 커질수록 memory 모드가 소프트 에러에 가장 취약함을 보였다. 실제 256M급 DRAM의 구조에 적용하여, 셀 캐패시턴스, bit line 캐패시턴스, sense amplifier의 입력 전압 감도들이 변화할 때 소프트 에러에 미치는 영향을 예측하였고, 이 결과들은 차세대 DARM 연구의 최적 셀 설계에 이용될 수 있다.

  • PDF

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

LCD의 Leakage 현상을 고려한 색재현 (Color Reproduction Based on Leakage Effect of LCD)

  • 허태욱;이상훈;한찬호;송규익
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(4)
    • /
    • pp.243-246
    • /
    • 2000
  • Recently, PC monitor users have been replacing cathode ray tubes (CRT) with liquid crystal displays (LCD). But the chromaticity of the primaries are dependent on RGB input signals. And the colorimetry of LCD changes with gray scale and has a poor peformance in color reproduction. In this paper we propose the enhanced algorithm of color reproduction considering color leakage error and black subpixel error in LCD. In order to test peformance of this algorithm we use the colors of Macbeth colorcheck. As a result of experiments, it was confirmed that the color difference of the LCD using the proposed algorithm was considerably reduced.

  • PDF