• 제목/요약/키워드: Leakage Direction

검색결과 190건 처리시간 0.021초

격납건물 라이너 플레이트 감육 검사를 위한 전자기 초음파 트랜스듀서의 설계 및 성능 평가 (Design and Test of ElectroMagnetic Acoustic Transducer applicable to Wall-Thinning Inspection of Containment Liner Plates)

  • 한순우;조승현;강토;문성인
    • 한국압력기기공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.46-52
    • /
    • 2019
  • This work proposes a noncontact ultrasonic transducer for detecting wall-thinning of containment liner plates of nuclear power plants by measuring their thickness without physical contact. Because the containment liner plate is designed to prevent atmospheric leakage of radioactive substances under severe nuclear accident, its wall-thinning inspection is important for safety of nuclear power plants. Wall-thinning investigation of containment liner plates have been carried out by measuring their thickness with contact-type ultrasonic thickness gauge by inspectors and needs a lot of time and cost. As an alternative, an electromagnetic acoustic transducer measuring precisely thickness of containment liner plates without any physical contact or couplant was suggested in this research. A transducer generating and measuring shear ultrasonic waves in thickness direction was designed and wave field produced by the transducer was analyzed to verify the design. The working performance of the suggested transducer was tested with carbon steel plate specimens with various thicknesses. The test result shows that the proposed transducer can measure thickness of the specimens precisely without any couplant and implies that swift scanning of wall-thinning of containment liner plates will be possible with the proposed transducer.

LNG 화물창 2차 방벽의 기계적 성능에 아라미드 섬유가 미치는 영향에 대한 연구 (Effects of Aramid Fiber on the Mechanical Properties of Secondary Barrier for LNG Cargo Containment System)

  • 방승길;염동주;정연제;김희태;김정대;이제명
    • 대한조선학회논문집
    • /
    • 제58권4호
    • /
    • pp.206-213
    • /
    • 2021
  • Recently, although the size of the LNG Cargo Containment System (CCS) has been increasing, the secondary barrier is reported to remain unchanged, and the conventional Flexible Secondary Barrier (FSB) used in Mark-III type has been pointed out to be vulnerable to failure owing to thermal and cyclic loads. In this respect, a tensile test was carried out to verify the reinforcing effect of FSB using aramid fiber on weft compared to the conventional FSB. In order to consider the LNG leakage situation, a series of tensile tests were conducted from ambient to cryogenic temperature, and mechanical properties were evaluated for each fiber direction on account of anisotropy. Tensile behavior and fracture analyses were performed to confirm the mechanical properties of each material according to temperature. Tensile test results proved that replacing the aramid fiber instead of E-glass fiber used on weft is effective in enhancing the mechanical properties.

이동식수소스테이션 정량적 위험성평가에 관한 연구 (A Study on the Quantitative Risk Assessment of Mobile Hydrogen Refueling Station)

  • 김동환;이수민;조충희;강승규;허윤실
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.605-613
    • /
    • 2020
  • In July and October of this year, the government announced the 'Green new deal plan within the Korean new deal policy' and 'Strategies for proliferation of future vehicles and market preoccupation'. And, in response to changes in the global climate agreement, it has decided to expand green mobility such as electric vehicles and hydrogen electric vehicles with the aim of a "net-zero" society. Accordingly, the goal is to build 310 hydrogen refueling stations along with the supply of 60,000 hydrogen vehicles in 2022, and the hydrogen infrastructure is being expanded. however, it is difficult to secure hydrogen infrastructure due to expensive construction costs and difficulty the selection of a site. In Korea, it is possible to build a mobile hydrogen station according to the safety standards covering special case of the Ministry of Industry. Since the mobile hydrogen station can be charged while moving between authorized place, it has the advantage of being able to meet a large number of demands with only one hydrogen refueling station, so it is proposed as a model suitable for the early market of hydrogen infrastructure. This study demonstrates the establishment of a hydrogen refueling station by deriving a virtual accident scenario for leakage and catastrupture for each facility for the risk factors in a mobile hydrogen station, and performing a quantitative risk assessment through the derived scenario. Through the virtual accident scenario, direction of demonstration and implications for the construction of a mobile hydrogen refueling station were derived.

육방정 질화붕소 나노입자의 결정성에 미치는 불화칼슘 첨가의 영향 (Effect of CaF2 Addition on the Crystallinity of Hexagonal Boron Nitride Nanoparticles)

  • 정재용;김양도;김영국
    • 대한금속재료학회지
    • /
    • 제56권12호
    • /
    • pp.915-920
    • /
    • 2018
  • With the development of modern microelectronics technologies, the power density of electronic devices is rapidly increasing, due to the miniaturization or integration of device elements which operate at high frequency, high power conditions. Resulting thermal problems are known to cause power leakage, device failure and deteriorated performance. To relieve heat accumulation at the interface between chips and heat sinks, thermal interface materials (TIMs) must provide efficient heat transport in the through-plane direction. We report on the enhanced thermal conduction of $Al_2O_3-based$ polymer composites, fabricated by the surface wetting and texturing of thermally conductive hexagonal boron nitride(h-BN) nanoplatelets with large anisotropy in morphology and physical properties. The thermally conductive polymer composites were prepared with hybrid fillers of $Al_2O_3$ macro beads and surface modified h-BN nanoplatelets. Hexagonal boron nitride (h-BN) has high thermal conductivity and is one of the most suitable materials for thermally conductive polymer composites, which protect electronic devices by efficient heat dissipation. In this study, we synthesized hexagonal boron nitride nanoparticles by the pyrolysis of cost effective precursors, boric acid and melamine. Through pyrolysis at $900^{\circ}C$ and subsequent annealing at $1500^{\circ}C$, hexagonal boron nitride nanoparticles with diameters of ca. 50nm were synthesized. We demonstrate that the addition of a small amount of calcium fluoride ($CaF_2$) during the preparation of the melamine borate adduct significantly enhanced the crystallinity of the h-BN and assisted the growth of nanoplatelets up to 100nm in diameters. The addition of a small amount of h-BN enhanced the thermal conductivity of the $Al_2O_3-based$ polymer composites, from 1.45W/mK to 2.33 W/mK.

유비쿼터스 컴퓨팅 환경내 개인정보보호 프레임워크 적용 방안 (Privacy Framework in Ubiquitous Computing Environments)

  • 홍승필;이철수
    • 정보보호학회논문지
    • /
    • 제16권3호
    • /
    • pp.157-164
    • /
    • 2006
  • 정보사회에서는 사회 구성원 개개인의 욕구를 충족시키는데 정보가 핵심적 역할을 하고 있다. 특히 유비쿼터스 컴퓨팅 환경에서는 개인 활동이 증가함에 따라 개인정보의 노출이 심해지고 개인정보 불법 취득도 점차 많아지고 있다. 이에 본 논문에서는 안전하고 효과적인 개인정보 관리체계와 기술적 구현이 용이하도록 개인정보 프레임워크를 제시하고, 시스템 개발자나 개인정보를 다루는 사업자 측면에서 개인정보 시스템을 설계하고 구현하기에 용이하도록 5단계의 구체적인 방법론을 제시하였다. 특히 제시된 방법론이 실 환경에 효과적으로 활용될 수 있도록 체계적인 개인정보 보호 시스템 개발 방안을 시스템 아키텍처 측면에서 소개함으로써, 본 논문의 활용 방안을 제시하였다. 본 논문에서 제시된 개인정보보호 프레임워크와 방법론은 실제 유비쿼터스 내 점점 중요시 되어가고 있는 개인정보 보호 측면에서의 방향성 제시 및 실제 엔지니어나 개발자 측면에서 이론위주의 설명보다는 실제 활용이 가능한 새로운 접근방안을 제시 할 수 있다고 사료된다.

안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가 (Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit)

  • 곽용국;홍순기;하민용;박장필;유숙현;조웅
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.87-95
    • /
    • 2015
  • 목 적 : 안와 주변 방사선 치료 시 수정체 피폭선량감소를 위하여 사용된 2차 차폐 block의 유용성을 알아보고자 한다. 대상 및 방법 : Human phantom(Alderson Rando Phantom, The Phantom Laboratory, USA)을 사용하여 CT(Somatom Definition AS, Siemens, Germany) 모의촬영 후 전산화치료계획시스템(Pinnacle, PHILIPS, USA)을 통해 실제 치료와 유사한 IMRT치료계획을 실시하였다. 2차 차폐를 위하여 두께 3mm 지름 25 mm의 납판과 3 mm tungsten eye-shield block(Extra small size, Radiation Products Design, Inc, USA)를 사용하였으며, TPS(Treatment Planning System) 상의 lens dose와 모의치료 상의 lens dose를 OSLD로 측정 비교하였다. 또한, 5 cm 두께의 acrylic phantom에 동일한 조건의 2차 차폐물인 3 mm 납판과 tungsten eye-shield block을 사용하여 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$)를 조사 및 측정하였으며, 조사야 밖의 누설선 및 투과방사선 영향을 제한시키고자 8 cm 납블럭(O.S.B: Outside Scatter Block)을 적용하여 위와 동일한 실험을 시행하였다. 조사야로부터 1 cm 이격하여 phantom 끝 옆면에 OSLD(Optically Stimulated Luminescence Dosimeter)를 부착하였고, eyelid의 두께에 해당하는 bolus 3 mm를 적용하였다. 결 과 : human phantom을 이용하여 IMRT 치료계획 상의 Lens dose와 실 측정치는 각각 315.9, 216.7 cGy가 측정되었고, 3 mm 납판과 tungsten eye-shield block으로 2차 차폐 후 각각 234.3, 224.1 cGy가 측정되었다. acrylic phantom을 이용한 실험 결과는 no block, 3 mm 납판, tungsten eye-shield block을 사용했을 때 5.24, 5.42, 5.39 cGy가 측정되었으며, 조사야 밖에 O.S.B를 적용하여 no block, 3 mm 납판, tungsten eye-shield block을 실험한 결과 각각 1.79, 2.00, 2.02 cGy가 측정되었다. 결 론 : 광자선 조사 시 critical organ을 보호하기 위하여 2차 차폐를 적용할 시에는 field 외부일지라도 헤드 누설방사선 및 collimator & MLC 투과방사선이 존재하므로 치료부위와 beam 방향에 따라 금속과 같은 높은 원자번호의 차폐물질이 critical organ근처에 있다면 선량 증가의 원인이 될 수 있다는 사실을 알 수 있었다. 따라서 피폭선량 감소를 위한 2차 차폐의 시도는 분명 의미가 있었으나 미 검증된 시도는 오히려 역효과를 가져올 수 있다는 사실을 인지하여 QA를 통해 목적에 부합하는 결과가 나오는지를 사전에 알아보아야 할 것이다.

  • PDF

인지된 위험의 유형이 소비자 신뢰 및 온라인 구매의도에 미치는 영향 (The Impact of Perceived Risks Upon Consumer Trust and Purchase Intentions)

  • 홍일유;김우성;임병하
    • Asia pacific journal of information systems
    • /
    • 제21권4호
    • /
    • pp.1-25
    • /
    • 2011
  • Internet-based commerce has undergone an explosive growth over the past decade as consumers today find it more economical as well as more convenient to shop online. Nevertheless, the shift in the common mode of shopping from offline to online commerce has caused consumers to have worries over such issues as private information leakage, online fraud, discrepancy in product quality and grade, unsuccessful delivery, and so forth, Numerous studies have been undertaken to examine the role of perceived risk as a chief barrier to online purchases and to understand the theoretical relationships among perceived risk, trust and purchase intentions, However, most studies focus on empirically investigating the effects of trust on perceived risk, with little attention devoted to the effects of perceived risk on trust, While the influence trust has on perceived risk is worth studying, the influence in the opposite direction is equally important, enabling insights into the potential of perceived risk as a prohibitor of trust, According to Pavlou (2003), the primary source of the perceived risk is either the technological uncertainty of the Internet environment or the behavioral uncertainty of the transaction partner. Due to such types of uncertainty, an increase in the worries over the perceived risk may negatively affect trust, For example, if a consumer who sends sensitive transaction data over Internet is concerned that his or her private information may leak out because of the lack of security, trust may decrease (Olivero and Lunt, 2004), By the same token, if the consumer feels that the online merchant has the potential to profit by behaving in an opportunistic manner taking advantage of the remote, impersonal nature of online commerce, then it is unlikely that the merchant will be trusted, That is, the more the probable danger is likely to occur, the less trust and the greater need to control the transaction (Olivero and Lunt, 2004), In summary, a review of the related studies indicates that while some researchers looked at the influence of overall perceived risk on trust level, not much attention has been given to the effects of different types of perceived risk, In this context the present research aims at addressing the need to study how trust is affected by different types of perceived risk, We classified perceived risk into six different types based on the literature, and empirically analyzed the impact of each type of perceived risk upon consumer trust in an online merchant and further its impact upon purchase intentions. To meet our research objectives, we developed a conceptual model depicting the nomological structure of the relationships among our research variables, and also formulated a total of seven hypotheses. The model and hypotheses were tested using an empirical analysis based on a questionnaire survey of 206 college students. The reliability was evaluated via Cronbach's alphas, the minimum of which was found to be 0.73, and therefore the questionnaire items are all deemed reliable. In addition, the results of confirmatory factor analysis (CFA) designed to check the validity of the measurement model indicate that the convergent, discriminate, and nomological validities of the model are all acceptable. The structural equation modeling analysis to test the hypotheses yielded the following results. Of the first six hypotheses (H1-1 through H1-6) designed to examine the relationships between each risk type and trust, three hypotheses including H1-1 (performance risk ${\rightarrow}$ trust), H1-2 (psychological risk ${\rightarrow}$ trust) and H1-5 (online payment risk ${\rightarrow}$ trust) were supported with path coefficients of -0.30, -0.27 and -0.16 respectively. Finally, H2 (trust ${\rightarrow}$ purchase intentions) was supported with relatively high path coefficients of 0.73. Results of the empirical study offer the following findings and implications. First. it was found that it was performance risk, psychological risk and online payment risk that have a statistically significant influence upon consumer trust in an online merchant. It implies that a consumer may find an online merchant untrustworthy if either the product quality or the product grade does not match his or her expectations. For that reason, online merchants including digital storefronts and e-marketplaces are suggested to pursue a strategy focusing on identifying the target customers and offering products that they feel best meet performance and psychological needs of those customers. Thus, they should do their best to make it widely known that their products are of as good quality and grade as those purchased from offline department stores. In addition, it may be inferred that today's online consumers remain concerned about the security of the online commerce environment due to the repeated occurrences of hacking or private information leakage. Online merchants should take steps to remove potential vulnerabilities and provide online notices to emphasize that their website is secure. Second, consumer's overall trust was found to have a statistically significant influence on purchase intentions. This finding, which is consistent with the results of numerous prior studies, suggests that increased sales will become a reality only with enhanced consumer trust.

국내외 특허 데이터 분석을 통한 금융보안 분야 주요 기술 동향 분석연구 (Research on major technology trends in the field of financial security through Korea and foreign patent data analysis)

  • 채호근;이주연
    • 디지털융복합연구
    • /
    • 제18권6호
    • /
    • pp.53-63
    • /
    • 2020
  • 인터넷과 스마트 디바이스, IoT와 같은 정보통신매체의 급격한 보급으로 전자금융거래 또한 활발히 증가하고 있지만 이에 따른 파생적 부산물로써 각종 개인정보 유출, 해킹과 같은 금융보안의 위협 또한 증가하고 있다. 따라서 이에 대비한 금융보안의 중요성은 높아지고 있지만 국내의 경우 아직 Active-X를 사용하고 있는 등 금융보안 분야의 선진국에 비해서는 상대적으로 금융보안 기술력이 미흡한 실정이다. 이에 본 연구에서는 국내·외 금융보안 관련 특허데이터를 토대로 IPC 분류 빈도분석, 키워드 빈도분석, 키워드 네트워크 분석으로 주요기술 동향을 비교하여 국내의 금융보안 분야의 주요 발전 방향성을 제시하고자 한다. 결론적으로는 최근 국내외 동향은 스마트 디바이스 기반 전자금융서비스 개발에 따른 관련 기술 개발에 초점이 맞춰진 것으로 판단된다. 이에 향후 상용화 단계의 기술로 선행적인 측면의 연구를 반영하는 논문 데이터 분석을 통해 금융보안 연구동향과 기술동향 분석 결과를 매핑함으로써 금융보안의 기술개발을 위한 기반데이터로 활용될 수 있고자 한다.

백서구치의 실험적 치아이동시 치근막 혈관변화에 관한 혈관주형법을 이용한 연구 (AN EXPERIMENTAL STUDY ON THE VASCULAR CHANGES OF RAT MOLAR PERIODONTAL LIGAMENT FOLLOWING ORTHODONTIC TOOTH MOVEMENT USING VASCULAR CORROSION CASTING METHOD)

  • 임용규;양원식
    • 대한치과교정학회지
    • /
    • 제24권1호
    • /
    • pp.37-62
    • /
    • 1994
  • This study was undertaken to investigate the three dimensional vascular changes of periodontal ligament following orthodontic tooth movement. Experimental tooth movement was carried out in 96 Sprague-Dawley rats with the weight of 250g. They were divided into four experimental groups (each 24 rats). The left maxillary first molar was moved mesially with 25g force in group I, and with 75g force in group II. Each three animals were sacrificed after 1, 6, 12, 24 hours, and 3, 7, 14, 21 days. In group III, 25g mesial force was applied for 3 days, and in group IV, 75g mesial force was applied for 3 days. Then the appliances were removed, and each three animals were sacrificed after 1, 6, 12, 24 hours, and 3, 7, 14, 21 days from removal of appliance. The contralateral molars were used for control group. Casting media was injected via left ventricle and polymerized in warm water. After corrosion of surrounding soft tissue, three dimensional vascular changes were examined using scanning electron microscopy. The findings of this study were as follows: 1. Pressure side of group I and II showed degenerative vascular changes such as vascular compression, reduction of vasculature, leakage of casting media. But, regenerative changes were dominant after 7 days of tooth movement. Although the degenerative vascular changes were more severe in group II, which was exposed to heavy force, the timing of these changes was not different between two groups. 2. Periodontal vasculature was reestablished by the growth of new capillaries and their differentiation and union from the remaining periodontal vessels and vessels of alveolar bone marrow. Although vascular regeneration was more rapid in group I, which was exposed to light force, the vasculature was not fully normalized in both groups even after 21 days. 3. There was no remarkable changes in tension side of group I and II, but looping of capillary, new capillary growth, dilation of vessels, redirection of vessels in the direction of tensile force were occurred. 4. In pressure side of group III and IV, in which appliance was removed after 3 days of orthodontic force, bone resorption was continued even after removal of appliance. Regeneration of vasculature was initiated after 1-6 hours, and it was more rapid in group III than group IV. In both groups, the vasculature was not fully normalized even after 21 days. 5. After removal of appliance, tension side of group III and IV showed vascular compression and loss of vasculature.

  • PDF

방향성 결합기 입사도파로의 최적 접근각도의 광모드 과잉쏠림 현장의 조절 (Investigation of Optimal input Angle for Directional Coupler and Field-profile Overshooting)

  • 이현식;오범환;최철현;노현식;이승걸;박세근;이일항
    • 한국광학회지
    • /
    • 제17권1호
    • /
    • pp.89-93
    • /
    • 2006
  • 방향성 결합기의 소멸비 특성 개선을 위해 입사도파로의 접근각도를 조절하는 방안의 가능성과 오차한계를 살펴보았다. 입사도파로의 접근각도가 크면 단순한 모드분석 이론의 틀에 오차를 유발하게 되지만 적절하게 조절하면 오차를 극소화하면서도 입사되는 광모드의 결합계수를 미세 조절함으로써 소멸비를 개선하는 효과가 있었다. 급격한 접근각도의 설정 시에는 비록 그 각도가 작아서 유출모드(leak mode)에 의한 손실이 있기 전이더라도 광모드의 과잉쏠림(field-profile overshooting)에 의해 각종 특성의 열화가 생기기 시작하는 것을 발견하고 그 영향을 분석하였다. 진행 광모드의 변화는 BPM(Beam Propagation Method)으로 전산 모사하였으며, 직선형 및 곡선형의 두 가지 입사도파로 구조에 대해 특성변화를 비교하여 소멸비 특성을 최적화하는 조건을 얻어내었다.