• 제목/요약/키워드: Leakage Defects

검색결과 178건 처리시간 0.022초

옥외전기시설물에 사용되는 600V CV케이블 정전용량의 영향 (Effect of the Capacitance for 600V CV Cable Applying Outdoor Electricity Facilities)

  • 이현구;하태현;배정효;김대경;김석원;이지인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.323-325
    • /
    • 2002
  • Because of the progress of civilization, outdoor electricity facilities as a street light, signal light and standing signboard etc. have being increased rapidly. Therefore the application of underground distributing wires is largely expended. In this paper, capacitance for the kinds of 600V CV cable is measured and leakage current for underground cable is calculated. The measurement of capacitance is done which there are defects of cable sheath or not Calculated leakage current is applied to choose the circuit breaker and the like.

  • PDF

경추부 경막외 혈액 봉합술로 치료한 자발성 두개내 저압 -증례 보고- (A Case Report of Spontaneous Intracranial Hypotension Treated with Cervical Epidural Blood Patch -A case report-)

  • 정성원;도현우;이정구
    • The Korean Journal of Pain
    • /
    • 제12권1호
    • /
    • pp.157-161
    • /
    • 1999
  • We report a patient with spontaneous intracranial hypotension. In addition to the cardinal feature of a postural headache and a low CSF pressure, the patient also had subdural hematoma demonstrated by brain MRI. Radionuclide cisternography revealed a CSF leakage in the intracranium. CSF leakage from spinal meningeal defects may be the most common cause of this syndrome. The headache is a consequence of the low CSF pressure producing displacement of pain-sensitive structures. Methods of treatment are identical to those for post-dural puncture headaches. We experienced a patient with spontaneous intracranial hypotension developed in the intracranium who was successfully managed with a cervical blood patch.

  • PDF

Characterization of Surface Damage and Contamination of Si Using Cylindrial Magnetron Reactive Ion Etching

  • Young, Yeom-Geun
    • 한국재료학회지
    • /
    • 제3권5호
    • /
    • pp.482-496
    • /
    • 1993
  • Radiation damage and contamination of silicons etched in the $CF_4+H_2$ and $CHF_3$ magnetron discharges have been characterized using Schottky diode characteristics, TEM, AES, and SIMS as a function of applied magnetic field strength. It turned out that, as the magnetic field strength increased, the radiation damage measured by cross sectional TEM and by leakage current of Schottky diodes decreased colse to that of wet dtched samples especially for $CF_4$ plasma etched samples, For $CF_4+H_2$and $CHF_3$ etched samples, hydrogen from the plasmas introduced extended defects to the silicon and this caused increased leakage current to the samples etched at low magnetic field strength conditions by hydrogen passivation. The thickness of polymer with the increasing magnetic field strength and showed the minimum polymer residue thickness near the 100Gauss where the silicon etch rate was maximum. Also, other contaminants such as target material were found to be minimum on the etched silicon surface near the highest etch rate condition.

  • PDF

누설자속법을 이용한 박강판의 결함탐상 (Inspection of Non-metallic Inclusions in Thin Steel Sheets Using Magnetic Flux Leakage Method)

  • 임종수;손대락
    • 한국자기학회지
    • /
    • 제10권6호
    • /
    • pp.302-309
    • /
    • 2000
  • 박강판의 내부에 존재하는 개재물성 결함을 검사하기 위해 누설자속법을 이용하여 탐상하는 시스템을 개발하였다. 연자성 코어의 보자력을 이용한 차등형 플럭스게이트 자력계를 제작하였다. FEM 소프트웨어를 이용하여 전자석을 설계하였으며, 3축 이동이 가능한 누설자속탐상장치를 제작하여 냉연강판을 검사한 결과 개재물성 결함을 검사학 수 있음을 알았다. 누설자속값을 디지털화하여 2차원 이미지로 처리한 결과 냉연강판에 존재하는 개재물성 결함 이외의 결함을 일부 구분할 수 있음을 알았다.

  • PDF

Virtual reality application on MFL gas pipeline inspection system

  • 김재준
    • 한국산업정보학회논문지
    • /
    • 제15권4호
    • /
    • pp.47-52
    • /
    • 2010
  • This paper describes a visualization technique that animates geometrical defect data that are extracted using a magnetic flux leakage (MFL) operating system on nondestructive evaluation (NDE). Since data are collected from different locations and often not regular, the data must be converted to the standard format that is used within the pipeline in visualization procedures. In order to navigate inside of the pipeline, 3D virtual objects are generated and are able to explore the pipeline continuously. The major objectives of this paper are to characterize, generate general shape of defects, and enable computer interaction in virtual environment. Pipeline navigation system (PNS) has introduced the framework for interactive visual applications based upon the principles of modeling 3D objects. PNS presents some preliminary efforts to enable the user to interact human and computer with each other.

월성1호기 계속운전 관련 결함연료위치탐지계통 배관의 열화관리평가 (Assessment on Aging Management of Delayed Neutron Monitoring System Tubing for Continued Operation of Wolsong Unit 1)

  • 송명호;김홍기;이영호
    • 한국압력기기공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.14-20
    • /
    • 2011
  • The end of design lifetime for Wolsong unit 1 will be reached on 20th November in 2012. So the license renewal documents for the continuous operation of Wolsong unit 1 is under reviewing now. Major components of primary system such as pressure tubes, feeder pipes including delayed neutron monitoring system tubing are being replaced and many components of secondary system are also being repaired. In this paper, the assessment on the wear degradation of delayed neutron monitoring system tubing(on the other hand, DN tube was called) was performed for the ageing management of the same component. The wear defects of this component was one of causes that resulted in heavy water leakage accidents. Therefore design specifications of Wolsong uint 1 and heavy water leakage accidents of pressurized heavy water reactors were reviewed and causes of wear defect for DN tubes were analyzed. Wear propagation equations based on the heavy water leakage history were made and the proper repairing time was possible to be expected if the continued operation was considered. Finally design change items of DN tubes that were conducted for the long term operation of Wolsong unit 1 are introduced.

Investigating the fatigue failure characteristics of A283 Grade C steel using magnetic flux detection

  • Arifin, A.;Jusoh, W.Z.W.;Abdullah, S.;Jamaluddin, N.;Ariffin, A.K.
    • Steel and Composite Structures
    • /
    • 제19권3호
    • /
    • pp.601-614
    • /
    • 2015
  • The Metal Magnetic Memory (MMM) method is a non-destructive testing method based on an analysis of the self-magnetic leakage field distribution on the surface of a component. It is used for determining the stress concentration zones or any irregularities on the surface or inside the components fabricated from ferrous-based materials. Thus, this paper presents the MMM signal behaviour due to the application of fatigue loading. A series of MMM data measurements were performed to obtain the magnetic leakage signal characteristics at the elastic, pre-crack and crack propagation regions that might be caused by residual stresses when cyclic loadings were applied onto the A283 Grade C steel specimens. It was found that the MMM method was able to detect the defects that occurred in the specimens. In addition, a justification of the Self Magnetic Flux Leakage patterns is discussed for demonstrating the effectiveness of this method in assessing the A283 Grade C steel under cyclic loadings.

Implementation of High Magnetization System for Performance Enhancement of Magnetic Flux Leakage Tool

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Kim, Dong-Ku;Park, Dae-Jin;Rho, Yong-Woo;Seo, Kang;Park, Gwan-Soo;Choi, Doo-Hyun;Song, Sung-Jin
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.199-203
    • /
    • 2010
  • This paper discusses the effectiveness of high magnetization saturation in ILI (In-Line Inspection) using an MFL (Magnetic Flux Leakage) tool, and introduces a practical method for improving the magnetization level together with the piggability. Thin steel plates, replacing the conventional wire brushes were used as conductors to transfer the magnetic flux to the pipe wall. The newly designed MFL tool was compared with the conventional version by means of FEM (Finite Element Method) analysis and full-scale experiments. In the results, the newly developed magnetization system obtained a stronger MFL signal amplitude, specially 2.7 times stronger, than that obtained by the conventional magnetization system for the same defect dimensions.

Computer Aided Identification of Inter-Layer Faults in Gas Insulated Capacitively Graded Bushing during Switching

  • Rao, M.Mohana;Dharani, P.;Rao, T. Prasad
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.28-34
    • /
    • 2009
  • In a Gas Insulated Substation (GIS), Very Fast Transients (VFTs) are generated mainly due to switching operations. These transients may cause internal faults, i.e., layer-to-layer faults in a capacitively graded bushing as it is one of the most important terminal equipment for GIS. The healthiness of the bushing is generally verified by measuring its leakage current. However, the change in current magnitude/pattern is only marginal for different types of fault conditions. Leakage current monitoring (LCM) systems generate large amounts of data and computer aided interpretation of defects may be of great assistance when analyzing this data. In view of the above, ANN techniques have been used in this study for identification of these minor faults. A single layer perceptron network, a two layer feed-forward back propagation network and cascade correlation (CC) network models are used to identify interlayer faults in the bushing. The effectiveness of the CC network over perceptron and back propagation networks in identification of a fault has been analysed as part of the paper.

Reliability and Degradation Mechanism of White GaN-Based Light-Emitting Diodes

  • 김현수;정은진
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.22.2-22.2
    • /
    • 2011
  • Reliability and degradation mechanism of conventional phosphor-converted white GaN-based light-emitting diodes (LEDs) were investigated. Under electro-thermal stress condition, the optical output degraded rapidly at the initial stress time accompanied by the change of chromatic properties. This could be attributed to the optical degradation of packaged materials, in particular, the browning of encapsulants and the darkening of reflective packages. At longer stress times, the optical output gradually decreased according to the degree of the reverse leakage currents, namely, the generation ofnonradiative recombination defects. This indicates that the optical degradation of white LEDs are dominated by the darkening of packaged materials and the generation of defects depending on the injection current and ambient temperatures. Using analyses of electroluminescence spectra, optical microscopy, electrical, optical, and thermal properties, optical degradations of white LEDs are discussed.

  • PDF