• Title/Summary/Keyword: Leak sites

Search Result 34, Processing Time 0.029 seconds

Identification and Distribution of Leak Sites of Half Mask Respirators (반면형 방진마스크의 누출부위 분포조사)

  • Hur, Ji Yeun;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.180-188
    • /
    • 1994
  • This study was designed to investigate qualitatively whether respirators now being used in workplaces tit workers iflfaces well or not. Leak sites were determined after exposing the subjects to fluorescent aerosol and were analyzed by gender, brand and manufacturing nation. The results were as follows ; 1. Among those leak sites which were classified into four areas(nose, cheek, lip and chin), test aerosol was mostly deposited on the nose and the cheek areas. 2. The mean number of leak sites observed from the female subjects were 2.3 while the number were 2.2 from the male subjects. The most frequently observed leak site was nose and followed by chin, lip and cheek in descending order of frequency. 3. Among different brands of respirators, different leak sites were observed. Test subjects wearing the Sand N brands were more heavily exposed than those of wearing the D and M brands. 4. No significant difference of the number of leak sites were found between Korean-made and American-made masks. However, the most frequent leak site observed for the Korean-made ones was the nose area while it was the chin area for the American-made ones. 5. Analyses of 97 leak sites by shape showed that 27(27.8%) were point types, 54(55.7%) diffuse types and 16(16.5%) streamline types. 6. Test subjects indicated that the facepieces of Korean-made respirators were harder and smaller in size than those of American-made one. The most comfortable respirator selected was the respirator by the N Co. and the most uncomfortable one was the respirator by the D Co. This study suggests that many half-mask respirators now being used in the workplaces may not fit to workers well. Therefore, when selecting respirators, employers are advised to test respirators if they fit to workers well. And manufacturers are recommended to produce effective and comfortable respirators tested qualitatively and quantitatively not only in the laboratory but also in the field.

  • PDF

Leak Detection of Waterworks Pipeline Using Acoustic Emission and Correlation Method (음향방출 및 상관법을 이용한 상수도배관 누수탐지 연구)

  • Yoon, Dong-Jin;Jeong, Jung-Chae;Lee, Young-Sup
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.84-89
    • /
    • 2003
  • Water leak is one of topics with great concern in Korea and many other countries, because of decreasing water supplies and the deterioration of old pipeworks. Correlation techniques have been widely used in leak detection of water pipes, which allow to locate a leak point based on the correlation of leak noise at two sites along water pipes. In this study, both the cross-correlation method and the conventional arrival time difference method are applied in order to analyze and to locate a leak point of a water pipe. In experiment, a 150 m of whole length waterwork pipeline system was constructed in a ground, and several types of leak noise were installed on the pipeline in order to control leak condition. Both the cross-correlation technique and the arrival time difference method showed favorable results at leak detection with the experimental pipeline system.

  • PDF

Development of Gas Leak Detecting System Based on Quantum Technology (양자기술기반 가스 누출 감지 시스템 개발)

  • Kwon, Oh Sung;Park, Min Young;Ban, Changwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.57-62
    • /
    • 2021
  • Gas is an energy source widely used in general households and industrial sites, and is also a process material widely used in petrochemical and semiconductor processes. However, while it is easy to use, it can cause large-scale human damage due to leakage, explosion, and human inhalation. Therefore, a gas facility safety management solution that can be safely used at home and industrial sites is essential. In particular, the need to develop advanced gas safety solutions is emerging as gas facilities are aging. In this paper, a technology was developed to measure the presence and concentration of gas leaks from a distance by irradiating photons, the minimum energy unit that can no longer be divided into gas facilities, and analyzing the number of reflected photons. This overcomes technical limitations such as short detection distance and inability to detect fine leaks, which are the limitations of conventional electric/chemical gas sensors or infrared-based gas leak detectors.

Traumatic cerebrospinal fluid leakage following septorhinoplasty

  • Youssef, Ahmed;Ahmed, Shahzad;Ibrahim, Ahmed Aly;Daniel, Mulvihill;Abdelfattah, Hisham M.;Morsi, Haitham
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.379-383
    • /
    • 2018
  • Septoplasty/septorhinoplasty is a common ear, nose and throat procedure offered for those patients with deviated septum who are suffering from nasal obstruction and functional or cosmetic problems. Although it is a basic and simple procedure, it could lead to catastrophic complications including major skull base injuries which result in cerebrospinal fluid (CSF) leaks. We describe two different cases of traumatic CSF leaks following septoplasty/septorhinoplasty at two different sites. The first patient suffered a CSF leak following septoplasty and presented to Alexandria University Hospital. The leak was still active at presentation and identified as coming from a defect in the roof of the sphenoid sinus and was repaired surgically. The second patient presented 4 days after her cosmetic septorhinoplasty with a CSF leak and significant pneumocephalus. She was managed conservatively. Understanding the anatomical variations of the paranasal sinuses and implementing proper surgical techniques are crucial in preventing intracranial complications when performing either septoplasty or septorhinoplasty. A good quality computed tomography of the nose and paranasal sinuses is a valuable investigation to avoid major complications especially CSF leaks following either procedure.

Industrial Technology Leak Detection System on the Dark Web (다크웹 환경에서 산업기술 유출 탐지 시스템)

  • Young Jae, Kong;Hang Bae, Chang
    • Smart Media Journal
    • /
    • v.11 no.10
    • /
    • pp.46-53
    • /
    • 2022
  • Today, due to the 4th industrial revolution and extensive R&D funding, domestic companies have begun to possess world-class industrial technologies and have grown into important assets. The national government has designated it as a "national core technology" in order to protect companies' critical industrial technologies. Particularly, technology leaks in the shipbuilding, display, and semiconductor industries can result in a significant loss of competitiveness not only at the company level but also at the national level. Every year, there are more insider leaks, ransomware attacks, and attempts to steal industrial technology through industrial spy. The stolen industrial technology is then traded covertly on the dark web. In this paper, we propose a system for detecting industrial technology leaks in the dark web environment. The proposed model first builds a database through dark web crawling using information collected from the OSINT environment. Afterwards, keywords for industrial technology leakage are extracted using the KeyBERT model, and signs of industrial technology leakage in the dark web environment are proposed as quantitative figures. Finally, based on the identified industrial technology leakage sites in the dark web environment, the possibility of secondary leakage is detected through the PageRank algorithm. The proposed method accepted for the collection of 27,317 unique dark web domains and the extraction of 15,028 nuclear energy-related keywords from 100 nuclear power patents. 12 dark web sites identified as a result of detecting secondary leaks based on the highest nuclear leak dark web sites.

Outcomes and predictors of response to endotherapy in pancreatic ductal disruptions with refractory internal and high-output external fistulae

  • Sridhar Sundaram;Biswa Ranjan Patra;Dhaval Choksi;Suprabhat Giri;Aditya Kale;Nitin Ramani;Abhijeet Karad;Akash Shukla
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.26 no.4
    • /
    • pp.347-354
    • /
    • 2022
  • Backgrounds/Aims: Endoscopic retrograde cholangiopancreatography (ERCP) remains the primary treatment for a subset of patients with pancreatic fistulae. The objective of this study was reporting outcomes of ERCP and predictors of resolution in patients with pancreatic fistulae refractory to conservative therapy. Methods: Retrospective review of patients who underwent ERCP and pancreatic stent placement for pancreatic fistula not responding to medical therapy was performed. Clinical features, laboratory parameters, radiological features and pancreatogram findings were noted. Clinical resolution of fistula was the primary outcome measure. Results: Sixty-eight patients underwent ERCP for high-output pancreatic fistula (Mean age 34.1 years, 91.1% males, 35/68 chronic pancreatitis, 52.9% alcohol etiology). Internal fistulae (pancreatic ascites, pleural effusion, or pericardial effusion) were seen in 55 (80.9%) patients and external fistula in 13 (19.1%) patients. Technical success for ERCP was 92.6% (63/68). Leak was seen in 98.4% (62/63). The most common leak site was body (69.8%). Multiple leak sites were seen in 23.1%. Pancreatic stricture was found in 36.5%. In 44 (69.4%) patients, stent was placed beyond the site of the leak. Resolution at six weeks was achieved in 76.4% (52/68). On univariate and multivariate analyses, placement of stent beyond site of leak was significantly associated with resolution of high-output fistulae (3/41 [7.3%] vs. 5/19 [26.3%], p = 0.03; odds ratio: 6.5, 95% confidence interval: 1.211-34.94). Conclusions: In our experience, ERCP was successful in 76% of patients with pancreatic fistulae refractory to conservative therapy. Stent placement beyond the site of leak was associated with higher resolution of fistulae.

Enhanced Stabilization of Carcasses by Retrofitting Burial Sites to Bioreactor (매몰지 생물반응조 개조를 통한 사체의 안정화 촉진)

  • Kim, Geonha;Jeon, Haeseong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.679-684
    • /
    • 2014
  • Many burial sites were constructed to suppress the spread of foot and mouth disease during outbreak. Defected burial sites were removed when leachate leak is presumed and carcasses were moved to the circular storage tanks. However, carcasses were not decomposed possibly due to low water content, low microbial activities, and poor mixing. In this research, storage tank containing carcasses in it was modified to bioreactor to accelerate stabilization. Liquids with nutrients were added and circulated to maintain the optimum water content while extraneous microorganisms were augmented. Settlement was used as the primary index for assessing stabilization rate, and the consolidation theory was utilized to estimate the expected final settlement. 30% of carcasses is expected to be decomposed and removed from the storage tank for five years of bioreactor operation.

Characteristics of AE Signals from Fatigue Crack Propagation and Penetration of a Surface Crack in 6061 Aluminum Plate

  • Ahn, Seok-Hwan;Nam, Ki-Woo
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.4 no.1
    • /
    • pp.44-50
    • /
    • 2001
  • Existing surface defects in structural members often act as sites of fatigue crack initiation, and if undetected, these cracks may grow through the thickness of the member, leading to catastrophic failure of the structure. Thus, in-service monitoring of fatigue cracks through reliable and effective nondestructive techniques is an important ingredient in the leak-before-break (LBB) design and safe operation of defects critical structures. An advanced, waveform-based, acoustic emission (AE) technique has been used in this paper to study the characteristics of the signals emanating from the initiation, growth and through-the -thickness penetration of surface fatigue crack in a 6061 aluminum plate. The goal of this experimental study is to determine whether the evolution of the fatigue crocks could be identified from the properties of the waveforms produced during the tests. The AE waveform signals detected at different stages of crack growth was found to have different temporal and spectral characteristics. The data analysis technique presented here can be applied to real-time monitoring of the initiation and propagation of fatigue cracks in structural components.

  • PDF

Design and Implementation of Gas Leakage Alarm IoT System for Safety Helmet (안전모 장착용 가스 누출 경보 IoT 시스템 설계 및 구현)

  • Ju, Yong-Min;Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1411-1416
    • /
    • 2018
  • Currently, most of the industrial areas like chemistry, manufacturing, shipbuilding, and steel, perform the work related to gas, and the staffs who are in charge of this work have a risk of suffocation without cognizing incidents like gas leak. For example, when the nitrogen gas leaked in 2015 at Paju, two people were killed and four people were injured. In 2018 at Pohang, four workers were suffocated to death from nitrogen gas. In order to solve this problem, this study realized the system in which workers could immediately cognize the gas leak and also deliver the situation to the staff in charge of safety at the same time, by installing the IoT device composed of gas sensor and communication module on the safety helmet that should be worn by field workers. This study is expected to be able to reduce the casualties caused by gas leak in industrial sites.

Incidence and Risk Factors for Surgical Glove Perforation (수술용 장갑의 천공률에 대한 연구)

  • Yoo, Seon Ju;Lim, Young Shin;Kim, Myung Suk
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.63-71
    • /
    • 2010
  • Purpose: This study was conducted to evaluate the incidence and risk factors for surgical glove perforation during operation. Methods: During the month of december 2008, a total of 1,400 pairs of surgical gloves used in major operations was collected in a tertiary hospital. All gloves were examined immediately after operation using the standardized water-leak method to detect any perforation. Incidence of the glove perforation was counted according to the type of operation, operation time, the number of involved personnel, perforation sites, and the manufacturing companies. Results: Out of 2,800 gloves examined, 312 perforations were detected comprising 11.1% of samples. In terms of the type of operation, the perforation incidence varied from 5% to 20%, and the perforation rates in CS (20%) and NS (18%) (p<.001) were significantly higher than those in other departments. The 1st assistant or scrub nurse got glove perforation more frequently than the 2nd assistant or operator (p<.001). Longer operation time was associated with higher incidence of perforation evidently (p<.001). In terms of the sites, the thumb and index finger were more frequently perforated than other sites (4.1% and 3.4% respectively) without any differences between left and right side. Conclusion: Risk factors for glove perforation including the department of operation, operation time, participating personnel, and location of perforation should be taken into account to improve surgical safety.