• Title/Summary/Keyword: Leak current

Search Result 102, Processing Time 0.023 seconds

Modification of Current Leak Before Break Criteria for Nuclear Piping System (원자력 발전소 배관에 대한 파단전누설 개념 적용기준의 수정)

  • Yu, Yeong-Jun;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1862-1871
    • /
    • 1996
  • The puopose of this paper is sto modify the current LBB criteria. The validity of current LBB criteria and current standard LBB analysis mehtod are evaluated using linear elastic fracture mechanics and elastic-plastic fracture mechanics. The results of evaluation demonstrate that the current LBB driteria are very conservative and some level of margins already exist in the standard LBB analysis method. Thus, the margin on load .root. and margin on crack size 2 can be eliminated to extend LBB application for the samller diameter pipe.

Conceptual Design of High-Tc Superconducting Current leads for Superconducting Nuclear Fusion Magnets with respect to various HTS tapes (HTS 선재에 따른 초전도 핵융합 마그넷용 고온초전도 전류도입선의 개념설계)

  • Jang, J.Y.;Chang, K.S.;Kim, Y.J.;Choi, S.J.;Jo, H.C.;Chu, S.Y.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.32-36
    • /
    • 2010
  • Superconducting current leads are indispensible for reducing power loss when subjecting current into superconducting magnets. HTS(High-Tc superconducting) current leads are divided into two types; one is bulk type and the other is tape type. In this paper, conceptual design on the HTS current leads which adopts tape type for nuclear fusion magnets is carried out using magnetic field analysis and thermal analysis. When large current flows through superconducting current leads, strong self magnetic field is generated and applied to the superconducting tapes. This phenomenon leads to the critical current decrease of the superconducting tape. Therefore, we analyzed magnetic field distribution of current leads and found the proper arrangement with respect to the various HTS tapes. In addition to the magnetic field analysis, heat leak through the current leads was also calculated to know which HTS tape is superior than others in thermal aspect. Magnetical field analysis and calculation of heat leak are performed to design 2 kA class HTS current leads.

Experimental Study on Leak-induced Vibration in Water Pipelines Using Fiber Bragg Grating Sensors

  • Kim, Dae-Gil;Lee, Aram;Park, Si-Woong;Yeo, Chanil;Bae, Cheolho;Park, Hyoung-Jun
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.137-142
    • /
    • 2022
  • Leak detection is one of the most important challenges in condition monitoring of water pipelines. Fiber Bragg grating (FBG) sensors offer an attractive technique to detect leak signals. In this paper, leak measurements were conducted on a water distribution pilot plant with a length of 270 m and a diameter of 100 mm. FBG sensors were installed on the pipeline surface and used to detect leak vibration signals. The leak was demonstrated with 1-, 2-, 3-, and 4-mm diameter leak holes in four different pipe types. The frequency response of leak signals was analyzed by fast Fourier transform analysis in real time. In the experiment, the frequency range of leak signals was approximately 340-440 Hz. The frequency shifts of leak signals according to the pipe type and the size of the leak hole were demonstrated at a pressure of 1.8 bar and a flow rate of 25.51 m3/h. Results show that frequency shifts detected by FBG sensors can be used to detect leaks in pipelines.

"Leak Current" correction for critical current measurement of no-insulation HTS coil

  • Song, Jung-Bin;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.48-52
    • /
    • 2017
  • Discrepancy between a power supply current and an actual "spiral" coil current makes the conventional 4-probe measurement of a critical current ($I_c$) of a no-insulation (NI) high temperature superconductor (HTS) coil inaccurate and time-consuming. This paper presents a fast and accurate approach for $I_c$ measurement of NI HTS coils. With an NI HTS coil energized at a constant ramping rate, a complete analytic expression for the spiral coil current was obtained from a first-order partial differential equation that derived from an equivalent circuit model of the NI coil. From the analytic solution, both spiral coil current and radial leak current can be obtained simultaneously, which enables fast and accurate measurement of the NI coil $I_c$. To verify the proposed approach, an NI double-pancake (DP) coil, wound with GdBCO tapes of $6mm{\times}0.1mm$, was constructed and its $I_c$ was repeatedly measured with various ramping rates in a bath of liquid nitrogen at 77 K. The measured results agreed well with the calculated ones, which validates the proposed approach to measure $I_c$ of an NI HTS coil.

An Investigation of Hazard Distance in a Series of Hydrogen Jet Fire with the Hyram Tools (수소 누출 시 제트화재 피해 범위에 대한 분석)

  • KANG, BYOUNG WOO;LEE, TAECK HONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.166-173
    • /
    • 2017
  • For commercialization of hydrogen refuelling station (HRS), we need to reduce the clearance distance for jet fire in the real entities in the HRS. Thus, we revisited the current regulations of clearance distance for jet fire in the law. The law in korea has been set up by replica of japan, not by our own scientific basis. Recently, sandia lab developed Hydrogen Risk Assessment Model (HyRAM) tools and we simulated a series of circumstances such as 10 to 850 bar with several leak hole sizes. In 850 bar with 10 mm diameter hole leak cases, it shows $4,981kW/m^2$ at 12 m separation from leak source and $1,774kW/m^2$ at 17 m separation from leak source. In 850 bar with 1 mm diameter leak hole, it shows $0.102kW/m^2$ at 12 m separation and $0.044kW/m^2$ at 17 m separation. Current law may be acceptable with 1 mm hole size with 850 bar.

Study of Multi-Step Current Lead (다단 전류도입선 해석)

  • Moon, J.S.;Seol, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.379-384
    • /
    • 2000
  • High-Tc superconducting current leads with multi-step and continually varied cross-sectional area are studied to reduce heat leak into cryostat and material use. Assuming conduction-cooled lead the cross-sectional area is reduced along the heat flow direction according to the increase of critical current density which increases with decreasing temperature. In this study, we also analyze the multi-step cross-sectional area High-Tc current leads. The multi-st데 current leads changes the cross-sectional area to have constant safety-factor at changed section. The heat leak into cryostat, total voume, safety-factor and the temperature profiles are compared to those of the constant safety-factor current leads. The developed methods are applied to the Bi-2223 superconductor sheathed with Ag-Au alloy.

  • PDF

A Study on Development of Internal Information Leak Symptom Detection Model by Using Internal Information Leak Scenario & Data Analytics (내부정보 유출 시나리오와 Data Analytics 기법을 활용한 내부정보 유출징후 탐지 모형 개발에 관한 연구)

  • Park, Hyun-Chul;Park, Jin-Sang;Kim, Jungduk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.5
    • /
    • pp.957-966
    • /
    • 2020
  • According to the recent statistics of the National Industrial Security Center, about 80% of the confidential leak are caused by former and current employees in the case of domestic confidential leak accidents. Most of the information leak incidents by these insiders are due to poor security management system and information leak detection technology. Blocking confidential leak of insiders is a very important issue in the corporate security sector, but many previous researches have focused on responding to intrusions by external threats rather than by insider threats. Therefore, in this research, we design an internal information leak scenario to effectively and efficiently detect various abnormalities occurring in the enterprise, analyze the key indicators of the leak symptoms derived from the scenarios by using data analytics and propose a model that accurately detects leak activities.

Location Estimation Method of Steam Leak in Pipelines Using Leakage Area Analysis (누설영역 분석을 이용한 배관 증기누설 위치 추정 방법)

  • Kim, Se-Oh;Jeon, Hyeong-Seop;Son, Ki-Sung;Park, Jong Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.384-390
    • /
    • 2016
  • It is important to have a pipeline leak-detection system that determines the presence of a leak and quickly identifies its location. Current leak detection methods use a acoustic emission sensors, microphone arrays, and camera images. Recently, many researchers have been focusing on using cameras for detecting leaks. The advantage of this method is that it can survey a wide area and monitor a pipeline over a long distance. However, conventional methods using camera monitoring are unable to target an exact leak location. In this paper, we propose a method of detecting leak locations using leak-detection results combined with multi-frame analysis. The proposed method is verified by experiment.

A Study on The Leak of Core Business Technologies Using Preventative Security Methods Such as Clustering (군집화를 이용한 기업 핵심기술 유출자 분류에 관한 연구)

  • Huh, Seung-Pyo;Lee, Dae-Sung;Kim, Kui-Nam
    • Convergence Security Journal
    • /
    • v.10 no.3
    • /
    • pp.23-28
    • /
    • 2010
  • Recently, the leak of domestic core technology of major business in Korea and the subsequent damage, has been increasing every year. Financial losses due to this leak are estimated to be about 220 trillion, which is equivalent to the gross budget of Korea Besides, the majority of the leaks are caused by former and current staff members, cooperated businesses, scientists and invesment companies. This shows that the source of the leaks are internal personnel. In this manner, we can infer that the management and plan of personnel security has not implemented sound practices to prevent technology leak by people. Therefore, this thesis suggests classifying methods of technology leak through clustering, one of the data mining methods about the information of internal personnel to prevent core technology leak from businesses.

Elastic Crack Opening Displacement of Slanted Circumferential Through-Wall Cracks in Thick-Walled Cylinder (원주방향 경사관통균열이 존재하는 두꺼운 배관의 탄성 균열열림변위)

  • Han, Tae-Song;Huh, Nam-Su;Shim, Do-Jun;Kim, Jin-Su;Lee, Jin-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.3
    • /
    • pp.13-22
    • /
    • 2012
  • According to recent research on leak-rate estimates to assess rupture probabilities of nuclear piping which contains a circumferential surface/through-wall cracks due to PWSCC, i.e., xLPR (Extremely Low Probability of Rupture) program, it has been revealed that the use of crack shape with an idealized circumferential through-wall crack during actual crack growth can lead to overestimate of the leak-rate. Thus, for accurate estimation of the leak-rate during crack growth, the more realistic crack shape that can simulate the crack shape transition from surface crack to through-wall crack should be used. In this context, in the present study, the elastic crack opening displacement of slanted circumferential through-wall crack in thick-walled cylinder was proposed based on 3-dimensional elastic finite element fracture mechanics analyses. To propose the elastic crack opening displacement of slanted circumferential through-wall crack in thick-walled cylinder, the geometric variables affecting crack opening displacement, i.e., thickness of cylinder, reference inner crack length and slant crack ratio were systematically varied. In terms of loading conditions, axial tension, global bending moment and internal pressure were considered. The present results can be applied to calculate the leak-rate considering more realistic crack shape transition from surface crack to idealized through-wall crack, and can be expected to enhance current leak-rate estimation scheme, for instance, in xLPR program etc.