• 제목/요약/키워드: Leaf motion

검색결과 28건 처리시간 0.027초

Automatic Multileaf Collimation Quality Assurance for IMRT using Electronic Portal Imaging

  • Jin, Ho-Sang;Jason W. Sohn;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.305-308
    • /
    • 2002
  • More complex radiotherapy techniques using multi leaf collimation(MLC) such as intensity-modulated radiation therapy(IMRT) has been increasing the significance of verification of leaf position and motion. Due to the reliability and robustness, quality assurance(QA) of MLC is usually performed with portal films. However, the advantage of ease of use and capability of providing digital data of electronic portal imaging devices(EPIDs) have attracted many attentions as alternatives of films for routine quality assurance in spite of the concerns about their clinical feasibility, efficacy, and the cost to benefit ratio. In our work, the method of routine QA of MLC using electronic portal imaging(EPI) was developed. The verification of availability of EPI images for routine QA was performed by comparison with those of the portal films which were simultaneously obtained when radiation was delivered and known prescription input to MLC controller. Specially designed test patterns of dynamic MLC were applied to image acquisition. Quantitative off-line analysis using edge detection algorithm enhanced the verification procedure in addition to on-line qualitative visual assessment. In conclusion, the EPI is available enough for routine QA with the accuracy of portal films.

  • PDF

연꽃식물 조직의 표피 특성과 연잎효과 (Epidermal Features of the Nelumbo nucifera Tissues and Lotus Effect)

  • 김인선
    • Applied Microscopy
    • /
    • 제42권2호
    • /
    • pp.95-103
    • /
    • 2012
  • 연잎효과는 연꽃의 잎에서 규명된 현상으로 표피세포에서 기원하는 미세구조에 의해 물방울이 잎 표면이나 내부조직에 침투하지 않고 경사면으로 흘러내리며 표면 위 먼지나 이물질을 함께 떨어지게 한다. 잎 표면을 항상 깨끗한 상태로 유지하는 자기정화 능력인 연잎효과에 대해서는 여러 영역에서 연구되고 다방면으로 응용되고 있으나 구조적인 측면에서 연잎을 생장단계별 또는 표피조직 부위별로 비교 조사한 연구는 거의 없는 실정이다. 이에 본 연구에서는 연잎과 줄기를 대상으로 생장단계별, 부위별 표피조직의 미세 표면구조를 연구하여 연잎효과 표면 특성을 조사하였다. 본 연구에서 조사된 연잎효과는 미세돌기와 왁스결정체가 발달한 잎의 상피조직에서만 나타나고, 왁스결정체만 발달한 하피 및 줄기의 표피조직에서는 확인되지 않았다. 이는 미세돌기의 발달이 연잎효과를 나타내는데 가장 중요한 요인이고, 왁스결정체가 돌기표면 위에 축적되면 연잎효과는 더 증가하는 것으로 밝혀졌다.

반월상 연골 전각의 깊은 수평 파열에서의 간단한 관절경 하부 연골편 절제술 - 수술술기 - (A Simple Arthroscopic Resection Technique for Inferior Leaf of the Deep Horizontal Tear in the Anterior Meniscal Horn - Technical Note -)

  • 이기병;이석범;장호근;문영완;강기훈;김계원
    • 대한관절경학회지
    • /
    • 제3권1호
    • /
    • pp.62-65
    • /
    • 1999
  • 반월상 연골의 수평 파열은 대개 외측의 관절막까지 이환될 경우가 많고, 여러 방향으로 찢어진 소견이 많으며, 상부와 하부의 두 연골편 중 안정성이 보존된 부위를 보존해야 되는 경우가 있으므로, 어떠한 모양의 파열보다도 치료가 기술적으로 어렵다고 보고되고 있다. 저자들은 이 같은 수술시 관절경칼을 이용하여 전각 연골 파열부의 외측에 위치한 연골 경을 인대에 약 5mm 정도의 절개를 가한 후, 절개 부위를 통하여 Retrograde punch를 수평 파열된 전각의 하부 연골편의 밑으로 밀어넣어 전각의 하부 연골편 내연부터 절제하여 외측 관절막 방향으로 필요한 만큼의 연골을 모두 절제하였다. 저자들은 내측 또는 외측 반월상 연골의 전각에 발생한 깊은 수평 파열에서, 기존의 관절경 수술 방법으로는 상부의 연골편을 남기면서 하부의 연골편을 적절히 절제하기 힘든 경우 간단히 사용될 수 있는 관절경 전각 하부 연골편 절제술을 고한하여 이를 보고하는 바이다.

  • PDF

Wi-Fi를 이용한 WiSee의 동향 분석 (WiSee's trend analysis using Wi-Fi)

  • 한승아;손태현;김현호;이훈재
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.74-77
    • /
    • 2015
  • WiSee는 Wi-Fi(802.11n / ac)의 주파수를 이용하여 사용자의 제스처로 동작인식을 하는 기술이다. 현재 모션 인식방식은 전용 장치(리프모션, 키넥트)를 사용하고 있으며, 인식범위는 30cm~3.5m 이며, 인식범위가 좁고 인식률을 높이기 위해서는 제한적인 거리를 유지해야하는 불편함이 있다. 반면에 WiSee에서 사용하는 장비는 Wi-Fi가 사용가능한 장소라면 어디서든 동작인식을 할 수 있으며, 투과성도 기존인식방식에 비해 뛰어난 장점이 있다. 이에 본 논문에서는 WiSee의 동작과정과 최근동향을 살펴본다.

  • PDF

체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가 (The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT)

  • 김연래;정진범;이정우;신영주;강동진;정재용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.

고정밀 이송을 위한 볼스크류용 체결기구의 특성에 관한 연구 (Characteristics of floating couplings of ball screw for high precision feeding system)

  • 김인찬;박천홍;정윤교;이후상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.610-614
    • /
    • 1996
  • As the run out error and misalignment of ball screw connected directly to guide table largely affect the motion accuracy of guideway, floating coupling that releases the table from screw nut except feed and rotational direction is needed todecrease its influences. The purpose of this study is to propose a practical model floating coupling of ball serew for high precision feeding system. The straightness, dynanic characteristics and micro step response of hydrostatic guideway, mounted with three types of coupling fixed type, leaf spring type and hydrostatic type, are tested and compared. From the resuts of experiments, it is proved that a hydrostatic type floating coupling is superior to other couplings and is available to high precision feeding system with ball screw.

  • PDF

압전소자와 미소변위 기구를 이용한 회전장치 개발 (Development of a Rotating Device Using Piezoelectric and Micro Displacement System)

  • 강시홍;엄태봉
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.494-497
    • /
    • 2003
  • A rotating device driven by an Inchworm motor was designed and fabricated to be used as an angie standard system. 1. PZT was adopted as a driving source, while the movement of PZT was guided by the leaf spring employing the elastic transformation of metals. 2. The device could rotate in a 360-degree arc. continuously Performance test of the device showed about 0.02 sec. of the minimum revolution angle and 1/15 rpm of the maimum revolution speed. 3. To improve its performance requires further studies on realizing a shifting device with faster response time, on increasing the output current (capacity) of the power amplifier used to drive PZT, on the dynamic motion of clamping. and on determining the optimum clamping condition

  • PDF

재료의 기계적 물성측정 시험장치를 위한 이중서보 시스템에 관한 연구 (Study of Dual Servo System for Measurement System of Mechanical Property)

  • 최현석;송치우;한창수;이형욱;최태훈;이낙규;나경환
    • 반도체디스플레이기술학회지
    • /
    • 제2권2호
    • /
    • pp.31-37
    • /
    • 2003
  • This paper presents a measurement system of mechanical property using dual servo system. There are many kinds of method to measure material properties such as tensile test, indention and bending test. It is highly required to measure the properties of nano-sized material and structure. However, It is need more accurate measurement system, more stable and frequency response than conventional test. In this paper, we designed the dual servo system for a measuring instrument The dual servo system consisting of a coarse stage and a fine motion stage with VCM and PZT is proposed. Mechanical mechanism is designed with the leaf spring type of flexure hinge joint. Lead compensator is applied to this control system, and is designed by PQ method.

  • PDF

꽃꽂이 작업의 관절가동범위와 근육활성도 측정 및 상지기능 향상을 위한 적용사례 (Measuring Range of Motion and Muscle Activation of Flower Arrangement Tasks and Application for Improving Upper Limb Function)

  • 이손선;박신애;권오윤;송종은;손기철
    • 원예과학기술지
    • /
    • 제30권4호
    • /
    • pp.449-462
    • /
    • 2012
  • 본 연구는 신체재활을 위해 다양한 꽃꽂이 작업들을 이용하기 위해서 꽃꽂이 작업 시 주로 사용되는 작업들을 분류하고, 각 작업 수행 시 사용되는 상지의 관절가동범위와 근육 활성도를 측정하였다. 또한 꽃꽂이 작업 시 상지의 관절 가동범위와 근육활성도 측정결과를 근거로 뇌졸중 환자의 상지기능 향상을 위한 꽃꽂이 프로그램을 개발하여, 실제 임상현장에서 적용하여 그 효과를 조사하였다. 상지 움직임을 정량적으로 분석하기 위해 주요한 꽃꽂이 작업을 분류한 다음, 작업 분석을 토대로 8가지 꽃꽂이 기본 작업(자르기 1, 굵은 줄기; 자르기 2, 가는 줄기; 꽂기 1, 긴 줄기; 꽂기 2, 짧은 줄기; 말기; 관엽 이용; 휘기 1, 굵은 줄기; 휘기 2, 가는 줄기; 감기, 절화용 와이어 이용)을 재분류하였다. 강원도 소재 대학의 8명의 남학생(평균 연령 $24.1{\pm}2.5$세)들이 8가지 꽃꽂이 작업을 수행하는 동안 삼차원 실시간 동작 분석 시스템과 근 전도 측정기를 이용하여 상지의 관절가동범위와 각 근육부위별 활성도를 각각 측정하였다. 이 측정결과를 토대로 상지기능 향상을 위한 꽃꽃이 프로그램을 개발하여, 서울시 소재 재활병원에 입원한 뇌졸중 환자들을 대상으로 실시하였다. 참여대상자들의 의사에 따라 4명은 원예치료군에 나머지 4명은 작업치료군에 배정되었다. 원예치료는 1일 2회(총 33회기)로 실시되었으며, 프로그램 전과 후에 뇌졸중 환자들의 상지기능 평가를 위해서 관절가동범위와 장악력 및 전반적인 상지기능평가가 수행되었다. 꽃꽂이 작업 수행 시 어깨관절은 자르기 1 작업에서 관절가동범위의 변화가 가장 큰 것으로 나타났고, 팔꿈치 관절은 감기 작업에서, 손목부위 관절은 휘기 1 작업에서 가장 큰 관절가동 범위를 나타냈다(P < 0.001). 수행된 꽃꽂이 작업에 따라 상지 근육의 부위별 근육 활성도는 다양한 변화를 보였으며, 한 가지 작업에 대해 여러 부위의 근육들이 동시에 사용되었다(P < 0.001). 또한 같은 방법으로 수행하는 작업일지라도 재료의 굵기나 길이에 따라 관절가동범위와 근수축의 차이가 나타났다(P < 0.001). 뇌졸중 환자의 상지기능 향상을 위해 실시된 꽃꽂이 작업을 이용한 원예치료 프로그램은 뇌졸중 환자들의 상지(어깨, 팔꿈치, 손목관절)의 가동범위와 장악력 및 전반적인 상지 기능에 긍정적인 영향을 미치는 것으로 나타났다. 따라서 본 연구는 꽃꽂이의 주요 작업을 이용하여 특정 신체부위의 기능향상이 필요한 대상자의 재활치료를 위한 프로그램 개발에 유용한 기초자료를 제시하였다. 추가적으로 실제 재활환자의 상태에 따라 효율적인 맞춤형 원예치료 프로그램을 개발하여 그 효과를 규명하는 연구가 필요할 것이다.

Biomimetically Engineered Polymeric Surfaces for Micro-scale Tribology

  • Singh R. Arvind;Kim Hong-Joon;Kong Ho-Sung;Yoon Eui-Sung
    • KSTLE International Journal
    • /
    • 제7권1호
    • /
    • pp.14-17
    • /
    • 2006
  • In this paper, we report on the replication of surface topography of natural leaf of Lotus onto thin polymeric films using a capillarity-directed soft lithographic technique. PDMS molds were used to replicate the surface. The replication was carried out on poly(methyl methacrylate) (PMMA) film coated on silicon wafer. The patterns so obtained were investigated for their friction properties at micro-scale using a ball-on-flat type micro-tribo tester, under reciprocating motion. Soda lime balls (1 mm diameter) were used as counterface sliders. Friction tests were conducted at a constant applied normal load of $3000{\mu}N$ and speed of 1mm/s. All experiments were conducted at ambient temperature ($24{\pm}1^{\circ}C$) and relative humidity ($45{\pm}5%$). Results showed that the patterned samples exhibited superior tribological properties when compared to the silicon wafer and non patterned sample (PMMA thin film). The reduced real area of contact projected by the surfaces was the main reason for their enhanced friction property.