• Title/Summary/Keyword: Lead determination

Search Result 290, Processing Time 0.025 seconds

DETERMINATION OF CADMIUM, COPPER, LEAD, ZINC AND MERCURY IN SEA WATER BY ATOMIC ABSORPTION SPECTROPHOTOMETRY (해수중 카드뮴, 구리, 납, 아연 및 수은의 원자흡광정량법)

  • WON Jong Hun;PARK Chung Kil;YANG Han Serb
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.169-175
    • /
    • 1976
  • A solvent extraction-atomic absorption spectrophotometry for determination of trace amount of cadmium, copper, lead and zinc and a flameless atomic absorption spectrophotometry for mercury in sea water were studied. The optimum pH range for solvent extraction was pH 4-7. A better solvent extraction efficiency was obtained with MIBK solvent than nitrobenzene, benzene, isoamylalcohol, n-buthylacetate. DDTC was more advantageous than APDC as chelating agent. The metals, chelated with DDTC and concentrated into MIBK by solvent extraction with a volume of $1\iota$ of sea water for cadmium, copper and lead, and 200m1 for zinc, were determined simultaneously by atomic absorption spectrophotometry. For mercury determination, 500ml of sea water was digested with permanganate-sulfuric acid and mercury( II ) was reduced by stannous chloride and aerated the solution with air pump until the absorbance reached a constant value. The precisions, in standard deviation, of these methods were 0.058ppb for cadmium, 0.084 ppb for copper, 0.44ppb for lead, 2.49ppb for zinc and 0.08 ppb for mercury. The sensitivities, expressed in $ppb/1\%$ absorption, were 0.058 ppb cadmium, 0. 15 ppb copper, 0.6 ppb lead, 1.2 ppb zinc and 0.01 ppb mercury respectively. No significant adsorption on the wall of polyethylene sample bottle occurred during 30 days of storing by acidification to pH 1.5 with nitric acid except zinc. Poor reproducibility was found for zinc with this method.

  • PDF

Geoid Determination in South Korea from a Combination of Terrestrial and Airborne Gravity Anomaly Data

  • Jekeli, Christopher;Yang, Hyo Jin;Kwon, Jay Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_2
    • /
    • pp.567-576
    • /
    • 2013
  • The determination of the geoid in South Korea is a national imperative for the modernization of height datums, specifically the orthometric height and the dynamic height, that are used to monitor hydrological systems and environments with accuracy and easy revision, if necessary. The geometric heights above a reference ellipsoid, routinely obtained by GPS, lead immediately to vertical control with respect to the geoid for hydrological purposes if the geoid height above the ellipsoid is known accurately. The geoid height is determined from gravimetric data, traditionally ground data, but in recent times also from airborne data. This paper illustrates the basic concepts for combining these two types of data and gives a preliminary performance assessment of either set or their combination for the determination of the geoid in South Korea. It is shown that the most critical aspect of the combination is the gravitational effect of the topographic masses above the geoid, which, if not properly taken into account, introduces a significant bias of about 8 mgal in the gravity anomalies, and which can lead to geoid height bias errors of up to 10 cm. It is further confirmed and concluded that achieving better than 5 cm precision in geoid heights from gravimetry remains a challenge that can be surmounted only with the proper combination of terrestrial and airborne data, thus realizing higher data resolution over most of South Korea than currently available solely from the airborne data.

Determination of Atmospheric Lead in Suwon City (수원지역의 대기 중 Pb의 농도 결정)

  • Lee, Tae-Jung;Kim, Seoun-Cheon;Kim, Dong-Sool
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.535-542
    • /
    • 1995
  • Monitoring of lead concentration in the ambient alt was performed in Kyung Hee University-Suwon Campus over a period of 5 year from November 1989 to September 1994 using a cascade impactor having 9 size stages. Lead level was analyzed by x-ray fluorescence. The lead levels have been extensively examined to identify annual trends, seasonal variations, and size distribution of lead concentration. Even though consumption of leaded gasoline has been decreased, the levels have not significantly changed during the sampling period. Probably other sources like fossil fuel emission and refuse incinerator will be potential contributors. The seasonal variation showed that Pb concentration significantly increased in the winter season and decreased in the summer season. The size distributions of Pb were observed to be unimodal distribution of the 1.1~2.1 $mu extrm{m}$ sixte ranges in the winter and 0.65~1.1 ${\mu}{\textrm}{m}$ in the summer.

  • PDF

Determination of Atmospheric Lead in Suwon City (수원지역의 대기 중 Pb의 농도 결정)

  • Lee, Tae-Jung;Kim, Seoun-Cheon;Kim, Dong-Sool
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.149-149
    • /
    • 1995
  • Monitoring of lead concentration in the ambient alt was performed in Kyung Hee University-Suwon Campus over a period of 5 year from November 1989 to September 1994 using a cascade impactor having 9 size stages. Lead level was analyzed by x-ray fluorescence. The lead levels have been extensively examined to identify annual trends, seasonal variations, and size distribution of lead concentration. Even though consumption of leaded gasoline has been decreased, the levels have not significantly changed during the sampling period. Probably other sources like fossil fuel emission and refuse incinerator will be potential contributors. The seasonal variation showed that Pb concentration significantly increased in the winter season and decreased in the summer season. The size distributions of Pb were observed to be unimodal distribution of the 1.1∼2.1 $mu extrm{m}$ sixte ranges in the winter and 0.65∼1.1 ㎛ in the summer.

Analytic study on lead and cadmium in glass materials (유리소재의 Pb 및 Cd 분석에 관한 연구)

  • Choi, Zel-Ho;Ko, Jae-Kwon
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.41-48
    • /
    • 2007
  • The determination method for the trace lead and cadmium in glass materials was developed by ICP-AES. The lead- and cadmium-DDTC chelates were formed by adding Na-DDTC (sodium diethyldithiocarbamate) as a chelating agent and extracted into MIBK (methyl-isobutyl ketone). Direct measuring of the trace lead and cadmium in glass was not possible because of the interferences of matrix elements as Na, Si, Mg and Ca of glasses unless solvent extraction of lead and cadmium was applied. This procedure was confirmed to be valid quantitative method of Pb and Cd analysis in glass did not influence of sample matrix, by applying it procedure to artifact sample and NIST SRM 1412.

Spectrophotometric Determination of Platinum (IV) with 2-Oximino-1-indanone (2-Oximino-1-indanone을 이용한 Pt(IV) ion의 정량에 관한 연구)

  • 김정균;유미경;원미숙;심윤보;고영심
    • YAKHAK HOEJI
    • /
    • v.28 no.2
    • /
    • pp.61-67
    • /
    • 1984
  • A method is described for the spectrophotometric determination of platinum (IV) with 2-oximino-1-indanone based on solvent extraction of Pt:2-oximino-1-indanone complex. The 2-oximino-1-indanone reacted with Pt(IV) to form a dark-orange complex which shows a characterisic maximum absorption at 342nm. The optimum PH for the platinum extraction lies between 5.4~8.0. Beer's law obeys up to 0.98-16.3ppm of platinum (IV) and the molar absorption coefficient is $1.06{\times}10^{-4}L.mol^{-1}.cm^{-1}$. The relative standard deviation of the method was $\times2.1%$. The composition of the complex is estimated to be Pt : In= 1 : 1, by the mole ratio method and ion exchange resin experiment. The optimum condition for the determination of platinum has been studied in detail. The 2-oximin-1-indanone is found to be a selectivereagent for the determination of platinum, since the synthesixed 2-oximino-1-indanone did not react with other metals such as cobalt, cadmium, copper, manganese nickel, iron, lead and zinc, to form the complex. In this studies, we have also clarified Sindhwani and Singh's spectrophotometric determination data of various metals with acenaphthenequinone monooxime (Talanta 20,248, 1973), whose results were not correct.

  • PDF

Determination of blood lead concentration by the atomic absorption spectrometry with graphite furnace-Comparison of blood lead concentration between occupationally exposed workers and control group (흑연로 장치가 부착된 원자흡광분석기를 이용한 혈중 납 농도 측정-직업적으로 납에 폭로된 근로자들과 비폭로 대조군간의 혈중 납 농도 비교)

  • Yang, Jeong Sun;Kang, Seong Kyu;Choi, Byung Sun;Park, In Jeong;Park, Dong Wook;Oh, Se Min;Jeong, Ho Keun
    • Analytical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.363-368
    • /
    • 1993
  • Blood lead concentrations of occupationally exposed workers were measured by the atomic absorption spectrometry with graphite furnace. The concentrations of the unexposed group were also checked and compaired with those of the exposed one. The correlation of smoking habit and work duration with the blood lead concentration was also surveyed.

  • PDF

Lead-Selective Poly(vinyl chloride) Membrane Electrode Based on 1-Phenyl-2-(2-quinolyl)-1,2-dioxo-2-(4-bromo) phenylhydrazone

  • Zare, Hamid Reza;Ardakani, Mahammad Mazloum;Nasirizadeh, Navid;Safari, Javad
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.51-56
    • /
    • 2005
  • A PVC membrane electrode for lead ion based on 1-phenyl-2-(2-quinolyl)-1,2-dioxo-2-(4-bromo) phenylhydrazone (PQDBP) as ionophore was demonstrated. The optimum composition of the membrane was 30 wt% poly(vinyl chloride), 60 wt% dibutyl phthalate as a plasticizer, 4 wt% ionophore and 6 wt% sodium tetraphenylborate as additive. The electrode exhibits a Nernstian response (28.7 mV decade$^{-1}$) for Pb$^{2+}$ over a wide concentration range (1.0 ${\times}$ 10$^{-1}$ to 1 ${\times}$ 10$^{-6}$ M) with a detection limit of 6.0 ${\times}$ 10$^{-7}$ M. This sensor has a short response time and can be used for at least 2 months without any divergence in potentials. The proposed electrode could be used in a pH range of 3.0-6.0 and revealed good selectivities for Pb$^{+2}$ over a wide variety of other metal ions. It was successfully applied as an indicator electrode for the potentiometric titration of lead ion with potassium chromate and for the direct determination of lead in mine.

A Study on the Characteristics of the Precision Blanking of Lead Frame (II): Determination of Optimal Process Condition (리드 프레임 타발공정의 전단특성에 관한 연구(II) - 최적 전단 조건의 선정)

  • 서의권;임상헌;심현보
    • Transactions of Materials Processing
    • /
    • v.11 no.2
    • /
    • pp.132-137
    • /
    • 2002
  • Using the Taguchi method, optimum process condition of lead frame blanking has been determined in the point of view of shape of blanked profile. As the main process parameters, clearance, strip holding pressure and bridge width are selected. According to the orthogonal array table, three levels of experiment have been carried out for each factor. The optimal blanking condition is analyzed with the SN ratio. It has been verified that the optimal Process condition can be determined with a combination of basic blanking experiment and experiment design method. Both the effect of each factor and gain can be judged in the quantitative manner from the analysis of SN ratio.

Spectrophotometric Determination of Trace Lead(II) After Extraction of Lead-Thiosulfate Complex into Aliquat336-CHCl$_3$ and Replacement by Cu (납-티오황산 착물생성과 구리치환에 의한 미량 납(II)의 비색분석에 관한 연구)

  • Lee, Seok-Ki;Joung, Chang-Ung
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.3
    • /
    • pp.1-5
    • /
    • 1998
  • A spectrophotometric method was developed for the acidic solution stripped after an extraction of 0.5 to 2.5 ppm of Lead(II) from 50 mL of $Na_2S_2O_3$ solution into chloroform as the ion-pairs formed between their thiosulfate complexes and alkylamine, Aliquat336. Pb(II) in the stripped solution forms an complex with DDTC in pH 7.3 buffer solution, and was developed in yellow by copper replacement. The ydlow-colored solution have the maximum absorbance at 435 nm in the measurement of absorbance by UV-Visible spectrophotometer. The interference ions such as Fe(III), Hg (II), Al(III), Co, Cu, Ni, Zn, Ca, Sn, have great effects on the extraction, but they were overcomed by the usage of adequate masking agents before an extraction. At last, a good result was obtained in applying this method to synthetic water.

  • PDF