• Title/Summary/Keyword: Layered

Search Result 3,986, Processing Time 0.04 seconds

An Examination of an Efficient UI of Smartphone Home Screen Structure (스마트폰의 홈 화면구조에 따른 효율적 UI 방안 모색)

  • Choi, Jinhae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.437-446
    • /
    • 2017
  • Objective: This study aims to draw an efficient UI design by comparing the usability of App drawer and single-layered home screens, which are smartphone home screens. Background: Because smartphone home screen is frequently used including the installation, deletion, and editing of APPs, it should be designed with easily controllable information structure. There is a need to seek a user-friendly UI by comparing the usability of App drawer and single-layered home screens, of which methods to search Apps are different. There is also a need to examine an efficient UI and the factors to improve from the user perspective. Method: This study targeted 30 Android OS and iOS users to evaluate the App drawer and single-layered home screens, of which UI structures are different. Each participant was instructed to carry out an App searching task and App deleting task, and the execution time and the number of errors were measured. After the tasks were completed, they evaluated satisfaction through a questionnaire survey. Results: In the App searching task with low task level, there was no difference in execution level between the App drawer and single-layered home screens. However, the single-layered home screen showed higher efficiency and accuracy in the App deleting task with high task level. As for the group difference according to use experience, there was no difference in satisfaction among Android OS users, but iOS user satisfaction with single-layered home screen with which they were familiar was higher. Conclusion: As for home screen usability, the single-layered home screen UI structure can be advantageous, as task level is higher. Repulsion was higher, when users, who had used easier UI, used complex UI in comparison with user satisfaction, when users familiar with complex UI used easier UI. A UI indicating the current status with clear label marking through a task flow chart-based analysis, and a UI in which a user can immediately recognize by exposing hidden functions to the first depth were revealed as things to improve. Application: The results of this study are expected to be used as reference data in designing smartphone home screens. Especially, when iOS users use Android OS, the results are presumed to contribute to the reduction of predicted barriers.

A Concept of Multi-Layered Database for the Maintenance and Management of Bridges (교량의 유지관리를 위한 멀티레이어 데이터베이스 개념)

  • Kim, Bong-Geun;Yi, Jin-Hoon;Lee, Sang-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.393-404
    • /
    • 2007
  • A concept of multi-layered database is proposed for the integrated operation of bridge information in this study. The multi-layered database is a logically integrated database composed of standardized information layers. The standardized information layers represent the data sets that can be unified, and they are defined by standardized information models. Classification system of bridge component was used as a basis of the multi-layered database, and code system based on the classification system was employed as a key integrator to manipulate the distributed data located on the different information layers. In addition, data level indicating priorities of information layers was defined to support strategic planning of the multi-layered database construction. As a proof of concept, a prototype of multi-layered database for object-oriented 3-D shape information and structural calculation document was built. Data consistency check of the semantically same data in the two different information layer was demonstrated, It is expected that the proposed concept can assure the integrity and consistency of information in the bridge information management.

A performance analysis of layered LDPC decoder for mobile WiMAX system (모바일 WiMAX용 layered LDPC 복호기의 성능분석)

  • Kim, Eun-Suk;Kim, Hae-Ju;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.921-929
    • /
    • 2011
  • This paper describes an analysis of the decoding performance and decoding convergence speed of layered LDPC(low-density parity-check) decoder for mobile WiMAX system, and the optimal design conditions for hardware implementation are searched. A fixed-point model of LDPC decoder, which is based on the min-sum algorithm and layered decoding scheme, is implemented and simulated using Matlab model. Through fixed-point simulations for the block lengths of 576, 1440, 2304 bits and the code rates of 1/2, 2/3A, 2/3B, 3/4A, 3/4B, 5/6 specified in the IEEE 802.16e standard, the effect of internal bit-width, block length and code rate on the decoding performance are analyzed. Simulation results show that fixed-point bit-width larger than 8 bits with integer part of 5 bits should be used for acceptable decoding performance.

A Program Analysis Technique for Recovery of Layered Architecture and Conformance Checking (층위구조 아키텍처의 복구 및 일치성 검사를 위한 프로그램 분석 방법)

  • Park Chanjin;Hong Euyseok;Kang Yoohoon;Wu Chisu
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.8
    • /
    • pp.730-741
    • /
    • 2005
  • Layered Architecture is a kind of nodule decomposition techniques, which decomposes a program by generality This paper proposes a ]aver based method for recovering layered architecture from object-oriented program and checking conformance against architectural document. To specify the rules for layered style in object-oriented program, we define a partially ordered set on modules by module use relationship and module layer relationship by module override relationship. The meaning of module layer relationship is explained with an example from design patterns. Steps to recover layered architecture from program are described and a metamodel for the recovery is proposed. Architecture recovery is performed on source codes from open-source software project, and the implication of parts that do not conform to its architectural document is discussed. As a result of checking, it is pointed out that, although the parts are considered allowable exceptions of layered architecture, their modifications should be controlled carefully.

Heating & Cooling Energy Performance Analysis of an Office Building according to SHGC level of the Double & Triple Glazing with Low-e Coating (이중 및 삼중 로이창호의 일사획득에 따른 사무소건물의 냉난방에너지 성능분석)

  • Kim, Hyo-Joong;Park, Ja-Son;Shin, U-Cheul;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.90-95
    • /
    • 2008
  • An SHGC(Solar Heat Gain Coefficient) is a determinant of total flux of solar radiation coming indoor and a critical factor in evaluating heating and cooling load. U-value represents heat loss while SHGC denominates heat gain. Recently, windows with high solar gain, mid solar gain or low solar gain are being produced with the development of Low-E coating technology. This study evaluated changes in energy consumption for heating and cooling according to changes in SHGC when using double-layered Low-E glass and triple layered Low-E glass in relation to double layered clear glass as base glass. An Office was chosen for the evaluation. For deriving optical properties of each window, WINDOW 5 by LBNL, an U.S. based company. and the results were analyzed to evaluate performance of heat and cooling energy on anannual basis using ESP-r, an energy interpretation program. Compared to the energy consumption of the double layered clear glass, the double layered Low-E glass with high solar gain consumed $69.5kWh/m^2,yr$, 9% more than the double layered clear glass in cooling energy. The one with mid solar gain consumed $63.1kWh/m^2,yr$, 1% less than the base glass while the one with low solar gain consumed $57.6kWh/m^2,yr$, 10% less than the base glass. When it comes to tripled layered glass, the ones with high solar showed 2% of increase respectively while the one with mid solar gain and low solar gain resulted 5% and 11% in decrease in energy consumption due to low acquisition of solar radiation. With respect to cooling energy. it was found that the lower the SHGC. the less energy consumption becomes.

  • PDF

Hydrothermal Synthesis and Exfoliation of Mg/Al Layered Double Hydroxide with Tailored Aspect Ratio (수열 합성 및 박리에 의한 Mg/Al 층상 이중 수산화물의 종횡비 제어)

  • Hwang, Sung-Hwan;Kim, Donghyun;Kim, Yewon;Jung, Hyunsung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.12
    • /
    • pp.822-827
    • /
    • 2017
  • Mg/Al layered double hydroxide with two-dimensional (2D) nanostructures was synthesized by a hydrothermal technique. The morphology and aspect ratio of $Mg_4Al_2(OH)_{14}3H_2O$ were controlled by the concentration and kinds of the hydrolysis agent, and temperature. The aspect ratio of $Mg_4Al_2(OH)_{14}3H_2O$ layered double hydroxides with the 2D hexagonal crystal structure was tailored from about 12.6 to about 45.7. The intercalated $CO{_3}^{2-}$ anions of the synthesized 2D $Mg_4Al_2(OH)_{14}3H_2O$ layered double hydroxides were exchanged to $NO_3{^-}$ anions. The bulk 2D $Mg_4Al_2(OH)_{14}3H_2O$ layered double hydroxides with the increased space between two layers due to the anion exchange were exfoliated in a formamide solution. The aspect ratio of the exfoliated 2D $Mg_4Al_2(OH)_{14}3H_2O$ layered double hydroxides increased to 570.3.

Comparison of Mechanical Properties of Zirconia Copping by multi-layered zirconia blocks and Design locations (다층 지르코니아 블록 종류와 설계위치에 따른 지르코니아 코핑의 기계적 특성 비교)

  • Kang, Jae-Min;Kim, Won-Young;Chung, In-Sung;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.167-175
    • /
    • 2019
  • Purpose: This study was investigated the effect of multi-layer zirconia block type and design location on the mechanical properties of zirconia copings. Methods: Three kinds of multi-layered zirconia blocks (Snow princess multi layered block, Multi cherry, Dental zirconia pre-shaded blank) were used to identify the effects of the kinds of multi-layered zirconia blocks, design locations on mechanical characteristics of zirconia copings. 150 Zirconia copings were fabricated and fracture strength, hardness and microstructure were compared and evaluated. Results: Dental zirconia pre-shaded blank(2,256.9N) had the highest fracture strength of zirconia copings on all the design locations, and it was followed by Snow princess multi layered block(2,107.5N) and Multi cherry(917.0N). Snow princess multi layered block(1,949.7Hv) had the highest hardness of zirconia copings on all the design locations, and it was followed by Dental zirconia pre-shaded blank(1,671.7Hv) and Multi cherry(1,383.7Hv). The cervical layer had the highest fracture strength and hardness of zirconia copings in all the blocks, and it was followed by the cervical+gradation layer, the enamel layer, the enamel+gradation layer, and the gradation layer. Conclusion: It was found that the fracture strength and hardness were different according to the kinds of multilayer zirconia block and design location, and it was confirmed that it is lower than the fracture strength of white zirconia.

Development of Control Method for Improving Energy Efficiency of Unmanned Underwater Gliders (무인 수중글라이더의 에너지 효율 개선을 위한 제어방법 개발)

  • La, Seung-kyu;Ko, Sung-hyup;Ji, Dae-hyeong;Chon, Seung-jae;Jeong, Seong-hoon;Choi, Hyeung-sik;Kim, Joon-young
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.2
    • /
    • pp.105-112
    • /
    • 2022
  • In this paper, unmanned underwater glider was designed for high-depth operation and adopted a bladder-type buoyancy controller for improving battery efficiency, and the motion controller controls the pitch angle by moving the internal mass battery. To improve the energy efficiency of the unmanned underwater glider, a layered PID controller that performs control by section was designed. Simulation program including 6-DOF motion equations and hydrodynamics coefficients of an unmanned underwater glider is constructed using Matlab/Simulink program. Control methods such as PID controller, sliding mode controller and layered PID controller were applied to the simulator to compare the dynamics performance and energy efficiency. As a result, the layered PID controller showed improved control performance compared to other controllers and improved energy efficiency of approximately 7.2% compared to PID controller.

Fabrication of PLGA/Dextran Double-Layered Microspheres by Oil-in-Water Solvent Evaporation Method (O/W 용매 증발법을 이용한 PLGA와 덱스트란의 이중층 미립구 제조)

  • Ko Jong Tae;Lee Jae-Ho;Lee Chang-Rae;Shin Hyung Sik;Yuk Soon Hong;Kim Moon Suk;Khang Gilson;Rhee John M.;Lee Hai Bang
    • Polymer(Korea)
    • /
    • v.29 no.6
    • /
    • pp.543-548
    • /
    • 2005
  • Double-layered spheres play an important role in controlling drug delivery for pharmaceutical application, because of the low initial burst compared with single-layered spheres and targetable delivery to specific organ. But it has drawback in loading drug and controlling size. In this study, we developed double-layered spheres using relatively simple oil-in-water (O/W) solvent evaporation method witw/without ultrasonication and investigated the size variation of the double-layered microspheres on the contents of poly(lactide- co-glycolide) (PLGA). Double - layered spheres were char-acterized by scanning elecron microscope (SEM), camscope, and confocal fluorescence laser microscope (CFLM). Double-layered spheres showed smooth surfaces and obvious difference between core and corona by SEM observation and camscope. We observed the fluorescent core in the double-walled spheres composed of FlTC-dextran and PLGA using CFLM. It was found that the core of the microsphere was dextran and the corona of the fabricate microsphere was PLGA. Also, the more PLGA concentration, the more the size of the fabricating double-layered sphere observed.

The Study on the Spherulitic Rhyolites in the northern part of Juwang Mt., Cheongsong (청송 주왕산 북부 일대의 구과상 유문암에 대한 연구)

  • 오창환;김성원;황상구;손창환;김창숙;김형식
    • The Journal of the Petrological Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.103-118
    • /
    • 2004
  • In Cheongsong area, very rare spherulitic rhyolites both in Korea and foreign countries occur as dykes showing various types. The spherulites in them represent an undercooling caused by very fast cooling of the dykes in a shallow depth near to the surface and the variety of types were resulted from the difference of relative cooling rate. Cheongsong spherulitic rhyolites can be classified into five types; radiated simple spherulite, layered simple spherulite, layered multiple spherulite, radiated-layered multiple spherulite, radiating layered multiple spherulite. Radiated simple and radiating layered multiple spherulites formed by diffusion current caused by undercooling related to very fast cooling. On the other hand, layered multiple spherulites formed by relatively slow diffusion as a Liesegang ring during relatively slow cooling. If the cooling rate is between the two cases, layered simple spherulites formed. This interpretation indicates that Chrysanthemum, Dandelion, Dahlia and Sunflower types which are included in radiated simple or radiating layered multiple spherulites formed in the dykes with the fastest cooling rate in Cheongsong area while Peony, Rose and Innominate types classified as layered multiple spherulite formed in the dykes with the relatively slowest cooling rate. At the cooling rate between them, Apricot type spherulite formed. The K-Ar age-dating for Cheongsong spherulitic rhyolites indicate them to be formed between 48 and 50 Ma. The Cheongsong rhyolites are very valuable for research and preservation because of their rarity, beauty and diversity.