• Title/Summary/Keyword: Layer-specific

Search Result 1,196, Processing Time 0.043 seconds

Expression and Reader Cognition of Japanese Comics Character (일본 만화 캐릭터의 표정과 독자 인지)

  • Yoon, Jang-Won
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.2
    • /
    • pp.246-254
    • /
    • 2007
  • As for comics and animation, the specific gravity came to become still larger in all the art fields together with the importance in various image media now which is useful and goes the time of the 21st century new media. Especially the demand of users to the vision culture which develops day by day, Sensitivity Engineering Department is trying to realize the necessity for a sensitivity design acutely together. The influence of the comics which have toxicity most also in Japanese culture in a geographical position like South Korea on it, and animation is the actual condition in the reason which has reached from youth universally to the layer for years, to be inquired systematic to a Korean comics language. This research was conducted as we thought sufficient study on various situations are required, and among them for the research of expressions of cartoons's characters, we've divided the expressions of characters that comes out in Japanese cartoons into categories of 'happiness, anger, sadness, pleasure' and 'fear, astonishment and dislike' and based on these categories, we've drawn out the minimum elements to express emotions in cartoon and prepared image-map by relating them with languages that express emotions of people and based on this, we've made a calculating tools on how our readers would recognize the expression languages. Samples of Japanese cartoons of which we've chosen for the purpose of drawing out the elements of expressions were limited to only published cartoons and we've made a foot steps for expression analysis of animation characters in the future.

Face Detection Using A Selectively Attentional Hough Transform and Neural Network (선택적 주의집중 Hough 변환과 신경망을 이용한 얼굴 검출)

  • Choi, Il;Seo, Jung-Ik;Chien, Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.4
    • /
    • pp.93-101
    • /
    • 2004
  • A face boundary can be approximated by an ellipse with five-dimensional parameters. This property allows an ellipse detection algorithm to be adapted to detecting faces. However, the construction of a huge five-dimensional parameter space for a Hough transform is quite unpractical. Accordingly, we Propose a selectively attentional Hough transform method for detecting faces from a symmetric contour in an image. The idea is based on the use of a constant aspect ratio for a face, gradient information, and scan-line-based orientation decomposition, thereby allowing a 5-dimensional problem to be decomposed into a two-dimensional one to compute a center with a specific orientation and an one-dimensional one to estimate a short axis. In addition, a two-point selection constraint using geometric and gradient information is also employed to increase the speed and cope with a cluttered background. After detecting candidate face regions using the proposed Hough transform, a multi-layer perceptron verifier is adopted to reject false positives. The proposed method was found to be relatively fast and promising.

A Study on the Utilization of Coal Fired Fly-ash as Microfine Grouting Materials (초미립자 지반주입재로서 플라이애쉬의 적용성에 관한 연구)

  • 천병식;김진춘
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.113-125
    • /
    • 1998
  • At the end of 1997 about 3 million tons of coal ash was produced as byproducts from the coal fired electrical power plants in Korea. Only about 27% of that byproducts was utilized as the admixtures of cement and concrete industry. But the large quantity of coal fired fly-ash has been used as the soil improvement materials in other countries. So the aim of this study is the estimation of the applicability of the coal fired fly-ash as microfine grouting materials by admixing the superfine particles which were separated from the coal fired fly-ash for the higher values. The 6 types of specimens were manufactured in the laboratory for the purpose of estimating the chemical and physical properties of cement and grouts. These specimens consisted of 2 specific surfaces of 6, 000 and 8, 000$cm^2$/g in Elaine method. And these specimens are devide into 3 ratios (30%, 50%, 70%) of fly-ash by weight. From the estimated properties of the coal fired fly-ash microflne cements and grouts, 50% fly-ash is the most suitable ratio for grouting materials. However, further study of durability is necessary for using fly-ash grouts practically at the field projects. The higher content of the unburned carbon of fly-ash increases the thinner layer of carbon on the surface of solution of grouts, and requires more quantity of surface active agent. As a results of this study, it is found that the microfine fly-ash is very useful as a good grouting material if 50% of fly-ash is added with the microfine portland cement. So, in the near future, if the coal fired fly-ash is able to be used as grouting material in Korea, the demand of fly-ash will increase rapidly.

  • PDF

A Study on the Hazardousness and the TLV in Working Environments of Benzine (벤진의 유해 위험성과 작업환경 노출기준 연구)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jung-Hee;Shin, Jea-Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.233-244
    • /
    • 2006
  • Of many volatile organic detergents for metals, benzine(CAS No. 8030-30-6), of which the toxicity has not yet been proven, has been used as an alternative of the halide compounds in the consideration of toxic effects, global warming and the destruction of ozone layer. In order to evaluate the effects of the benzine on human body by investigating the subchronic inhalation toxicity, to obtain the basic data for establishing the criteria of exposure in working environments and to classify the hazardousness in compliance with the Industrial Safety and Health Act by evaluating the hazardousness, repeated inhalation exposure test was carried with SD rats. The rats were grouped by 10 females and males each. The repetitive inhalation exposures were carried out at 4 levels of concentration of 0 ppm, 60 ppm, 300 ppm, and 1,500 ppm, for 6 hours a day, 5 days a week, for 13 weeks. The results are described hereunder. 1. No death of the animals of the exposed and controlled groups in the test period. Not any specific clinical symptoms, change in feed intake quantity, abnormality in eye test, or change in activity were observed. 2. In the 300 ppm and 1,500 ppm groups, weight reduction in the female groups and weight increase of liver and kidney in the male groups compared with control group were observed with statistical significance(p<0.05). 3. In the blood test, the HCT increased in the male 300 ppm group and the number of hematocyte increased, MCV and MCH decreased in the male 1,500 ppm group. In the female 1,500 ppm group, the HB decreased and the distribution width of the hematocyte particle size increased. In the blood biochemistry test, the TP in the male 1,500 ppm group and the LDH in the female 1,500 ppm group were increased with statistical significance(p<0.05). 4. Under the test conditions of the present study with SD rats, the NOEL was evaluated to be from 60 ppm to 300 ppm for both male and female groups. By extrapolation, the NOEL for human who work 8 hours a day was evaluated to be from 128 ppm to 640 ppm 5. Since the NOEL evaluated in this study do not exceed 60ppm(0.184 mg/L) the test material does not belong to the classification of the hazardous substance "NOEL${\leq}$0.5mg/L/6hr/90day(rat), for continuous inhalation of 6hours a day for 90 days" nor to the basic hazardous chemical substance class 1(0.2 mg/L/6hr/90day(rat) defined by the GHS which is a criteria of classification and identification of chemical compounds. However, considering the boiling point($30-204^{\circ}C$), flashing point($-40^{\circ}C$), vapor pressure(40 mmHg), and the inflammable range(1.0 - 6.0 %), sufficient care should be taken for handling in the safety aspects including fire or explosion.

Effect of Sampling and Analytical Methods on the Fibrous Materials from the Ground Water (시료 채취 조건 및 검사방법에 따른 지하수내 섬유상 물질 검출 양상에 관한 연구)

  • Kim, Ji-Yong;Kim, Jung Ran;Cheong, Hae-Kwan;Lim, Hyun-Sul;Paik, Nam-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.209-222
    • /
    • 1997
  • Authors surveyed the ground water near the waste disposed from a fiberglass production factory to confirm the presence of glassfiber in the water and to determine the effect of sampling conditions and storage on the recovery of fibrous materials in the ground water. Sample was collected at every 4 hours for 48 hours consecutively. After finishing the 48 hours sample, water sampling was done from each tap after repeated turning on and off the water for 30 seconds at each time. Sample was collected in the two 1.5 liter polyethylene bottle after vigorously shaking the bottle with the same water several times with the flowing tap water. At each paired sample, one bottle was stored stand still at room temperature, and the other sample was filtered immediately after sampling. Water was filtered on the Mixed Cellulose Ester filter with negative pressure. Each sample was divided into upper and lower layer. The other bottle was stored at room temperature standstill for 7 days and filtered in the same fashion as the other pair of sample did. Each MCE filter was divided into 4 pieces and one piece was treated with acetone to make it transparent. Each prepared sample was observed by two researchers under the light and polarizing microscopy, scanning electron microscopy and energy dispersive X-ra microanalysis. Fibers were classified by the morphology and polarizing pattern under the polarizing microscope, and count was done. 1. There was a significant fluctuation in number of the fibers, but there was no specific demonstrable pattern. 2. Non-polarizing fibers frequently disappeared after 7 days's storage. But cluster of fibers were found at the wall of the same container by scratching technique. 3. Polarizing fibers were usually found in between the filter and the manicure pasted area. Possible explanations for this phenomenon will be that either these fibers are very light or have electronic polarity. Hence, these fibers are not able to be attached on the surface of slide glass. 4. Under the scanning electron microscopic examination, the fibers which are not refractive under the light microscopy were identified as glassfiber. Other fibers which is refractive under the polarizing microscopy were identified as magnesium silicate fibers. It is strongly suggested that development of standardized method of sample collection and measurement of fibrous material in the water is needed.

  • PDF

Uncooled Metallic Thin-film Thermopile Infrared Detector (비냉각 금속 박막형 열전퇴 적외선 검지기)

  • Oh, Kwang-Sik;Cho, Hyun-Duk;Kim, Jin-Sup;Lee, Yong-Hyun;Lee, Jong-Hyun;Lee, Jung-Hee;Park, Se-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.2
    • /
    • pp.5-12
    • /
    • 2000
  • Uncooled metallic thin-film thermopile infrared detectors have been fabricated, and the figures of merit for the detectors were examined. The hot junctions of a thermopile were prepared on a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$-membrane which acts as a thermal isolation layer, the cold junctions on the membrane supported with the silicon rim which functions as a heat sink, and Au-black was used as an infrared absorber. Infrared absorbance of Au-black, which strongly depends on the chamber pressure during Au-evaporation and its mass per area, was found to be about 90 % in the wavelength range from 3${\mu}{\textrm}{m}$ to 14${\mu}{\textrm}{m}$. Voltage responsivity, noise equivalent power, and specific detectivity of Bi-Sb thermopile infrared detector at 5 Hz-chopping frequency were about 10.5V/W, 2.3 nW/Hz$^{1/2}$, 및 $1.9\times10^{7}$ cm.Hz$^{1/2}$/w at room temperature in air, respectively.

  • PDF

Analysis for the Effect of EMI Shield Layers' Height on Circuit Function (EMI 차폐막의 높이가 회로의 기능에 미치는 영향 분석)

  • Kim, Hyeon-Woo;Woo, Jin-Ha;Jang, Se-Hyun;Chang, Tae-Soon;Lee, Won-Hui;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.57-63
    • /
    • 2019
  • S-parameters were used to analyze the effect of the circuit according to the height of the EMI shield layers. Among the S-parameters, S11, S21, S22, and S31 were used as factors for determining the effect on the circuit function. Simulations were performed using shields made of Graphite and Ferrite, and the frequencies were run from 100 MHz to 1 GHz. As the height of the shield was increased, the value of S21 was getting closer to 0 dB. In addition, the SE value was confirmed to improve the shielding performance according to the thickness of the insulating layer only in a specific frequency band. Based on 800um with thickest silicon dioxide thickness, the FG structure averaged -1 dB in narrow frequency bands between 100 MHz and 300 MHz, showing better efficiency than GF with an average of -2 dB. Although GF structures do not show high efficiency, they exhibit average performance of -3 dB in frequency bands between 100 MHz and 1 GHz rather than FG structures that sway over a wide range. In other words, FG and GF structures have trade-off structures. Therefore, it should be noted that the appropriate structure is selected for use.

Surface Chemical Aspects of Coagulation, Deposition, and Filtration Processes: Variation of Electrokinetic Potential at Metal Oxide-Water and Organic-Water Interfaces in the $Na^+$ and $Ca^{2+}$ Ion Solutions

  • Kim, Sung-Jae
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.3
    • /
    • pp.173-183
    • /
    • 2000
  • This study measured the zeta potential of both latex colloidal particles with carboxylate surface groups and glass beads (collectors) with silanol surface group employing various solution with different chemical characteristics. The results have been compared with the surface chemistry theory. The zeta potential of the particle and collector increased with increasing pH up to 5.0 regardless of the solution chemistry. For a monovalent electrolyte solution(sodium chloride solution) the zeta potential steadily increased until the pH reached 9.5. In contrast, little change in zeta potential was made between 5.0 and 9.5 for a divalent electrolyte solution (sodium chloride solution) the zeta potential steadily increased until the pH reached 9.5. In contrast, little change in zeta potential was made between 5.0 and 9.5 for a divalent electrolyte solution (calcium chloride solution). In other words, the more the pH decreases, the larger the effect of neutral salts, such as NaCl and CaCl$_2$, have on the ζ-potential values. In this study, the PZPC(point of zero proton condition) of the particle and collector occurred below a pH of 3.1, H(sup)+ and OH(sup)- acted as a PDI (potential determining ion), and Na(sup)+ acted as an IDI(indifferent ion). The magnitude of the negative ζ-potential values of the particle and collector monotonically increased as the concentrations of Na(sup)+ or Ca(sup)2+([Na(sup)+] or [Ca(sup)2+]) decreased (the values of pNa or pCa increased). In the case of latex particles, the ζ-potential should aproach zero (isoelectric point; IEP) asymptotically as the pNa approaches zero, while in the case of calcium chloride electrolyte, ζ-potential reversal may be expected to occur around 3.16$\times$10(sup)-2MCaCl$_2$(pCa=1.5). pH, valance and ionic strength can be used in various ways to improve the water treatment efficiency by modifying the charge characteristics of the particle and collector. Predictive capability is far less certain when EDL(electrical double layer) repulsive forces exist between the particle and collector.

  • PDF

The Analysis and Design of Advanced Neurofuzzy Polynomial Networks (고급 뉴로퍼지 다항식 네트워크의 해석과 설계)

  • Park, Byeong-Jun;O, Seong-Gwon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.39 no.3
    • /
    • pp.18-31
    • /
    • 2002
  • In this study, we introduce a concept of advanced neurofuzzy polynomial networks(ANFPN), a hybrid modeling architecture combining neurofuzzy networks(NFN) and polynomial neural networks(PNN). These networks are highly nonlinear rule-based models. The development of the ANFPN dwells on the technologies of Computational Intelligence(Cl), namely fuzzy sets, neural networks and genetic algorithms. NFN contributes to the formation of the premise part of the rule-based structure of the ANFPN. The consequence part of the ANFPN is designed using PNN. At the premise part of the ANFPN, NFN uses both the simplified fuzzy inference and error back-propagation learning rule. The parameters of the membership functions, learning rates and momentum coefficients are adjusted with the use of genetic optimization. As the consequence structure of ANFPN, PNN is a flexible network architecture whose structure(topology) is developed through learning. In particular, the number of layers and nodes of the PNN are not fixed in advance but is generated in a dynamic way. In this study, we introduce two kinds of ANFPN architectures, namely the basic and the modified one. Here the basic and the modified architecture depend on the number of input variables and the order of polynomial in each layer of PNN structure. Owing to the specific features of two combined architectures, it is possible to consider the nonlinear characteristics of process system and to obtain the better output performance with superb predictive ability. The availability and feasibility of the ANFPN are discussed and illustrated with the aid of two representative numerical examples. The results show that the proposed ANFPN can produce the model with higher accuracy and predictive ability than any other method presented previously.

A Study on the Velocity, the Grain Size and the Bed Depth of the Rapid Filter (급속여과지(急速濾過池)의 여과속도(濾過速度)와 여재구성(濾材構成)의 연구(硏究) -여과저항(濾過抵抗)을 중심(中心)으로-)

  • Kang, Yong Tai
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.1-7
    • /
    • 1983
  • In spite of extensive knowledge of the surface chemistry and the transport mechanism in filtration systems, there is still insufficient understanding of the physical characteristics of suspensions and the system components. Because of this, no filtration mechanisms are mathematically generalized to the full extent. The purpose of this paper is to propose experimental equations for the filtration process. using the tracer study in filter layer. Some of results are as follows. (1) The Volume of the specific deposit (${\sigma}$) in filtration was directly measurable using the tracer study without interrupting the filtration. (2) It was also confirmed that the head loss in filtration was greatly in fluenced by the micro-air babbles. (3) The correction coefficient(f) was introduced into the Kozeny-Carman equation in order to apply it for the clogging filter media. The coefficient(f) was experimentally obtained. The total head loss of the filter media is given by next equation. $${\frac{h}{h_0}}={\frac{1}{L}}{\int}^{z=L}_{z=0}f({\sigma})g({\varepsilon}_0,{\sigma})dz$$ $$f=aexp(-b{\sigma})$$ The above equation was applicable without regard to the variation of the suspension concentration, the filter medium diameter, the filter depth, the filtration velocity, and the amount of aluminum in all continuous filtration experiments. (4) The total head loss was graphically generalized assuming mathematical filtration models I II (see fig. 7,8) (5) The total head loss was obtained from the filtration model in the field filtration conditions. (see fig. 9,10)

  • PDF