• Title/Summary/Keyword: Layer of Protection Analysis

Search Result 115, Processing Time 0.02 seconds

Study on Security Framework using Security Quantitative Analysis for the Effective Multimedia Services to WLAN Mesh Network (무선랜 메쉬 네트워크에서의 효율적인 멀티미디어 서비스를 위한 보안 정량화 기반의 프레임워크 연구)

  • Shin, Myoung-Sub;Lim, Sun-Hee;Yi, Ok-Yeon;Lim, Jong-In
    • Journal of Broadcast Engineering
    • /
    • v.13 no.2
    • /
    • pp.261-273
    • /
    • 2008
  • Multimedia service whose use is rapidly increasing supports effective services to convert and transmit multimedia data based on network speed, noise circumstance, terminal computation, and type of contents for satisfying QoS. For supporting information protection of multimedia service, it offers middle level of singular security service or security mechanism which is based on policy of service provider, depending on present terminal computation and type of contents. It can support security mechanism for more effective multimedia service, if we study security of application layer and network layer for supporting multimedia service. In this paper, we propose Multimedia security framework reflected on quantitative analysis of the WLAN(Wireless Local Area Network) mesh network security using the utility function in the level of the sorority, violation and addictive compensation model.

Fire Resistant Performance of Anti-Spalling ECC Layers in High-Strength Concrete Structures (ECC로 피복된 고강도콘크리트의 폭렬저감 및 열적특성에 관한 실험적 연구)

  • Lee, Jae-Young;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.199-202
    • /
    • 2008
  • The purpose of this study is to obtain the fundamental fire resistance performance of engineered cementitious composites(ECC) under fire temperature in order to use the fire protection material in high-strength concrete structures. The present study conducted the experiment to simulate fire temperature by employing of ECC and investigated experimentally the explosion and cracks in heated surface of these ECC. In the experimental studies, 3 HSC specimens are being exposed to fire, in order to examine the influence of various parameters(such as depth of layer=20, 30, 40mm; construction method=lining type) on the fire performance of HSC structures. Employed temperature curve were ISO 834 criterion(3hr), which are severe in various criterion of fire temperature in building structures. The numerical regressive analysis and proposed equation to calculate ambient temperature distribution is carried out and verified against the experimental data. By the use of proposed equation, the HSC members subjected to fire loads were designed and discussed.

  • PDF

Improved flame retardant performance of cellulose fibers following fluorine gas treatment

  • Kim, Jong Gu;Lee, Young-Seak;In, Se Jin
    • Carbon letters
    • /
    • v.28
    • /
    • pp.66-71
    • /
    • 2018
  • To improve the flame retardant performance of cellulose fibers, fluorine functional groups were introduced under various controlled fluorination conditions. The properties of the fluorinated cellulose fibers were analyzed by X-ray photoelectron spectroscopy and a thermogravimetric analysis. The fluorine functional group content in the fluorinated cellulose fibers increased with an increase in the fluorination temperature. However, the fluorination reaction increased the char yield and decreased the rate of degradation of the cellulose fibers by introducing donors, enabling the formation of a thick and compact char layer. Therefore, the flame retardant properties of cellulose fibers were improved following the fluorination treatment.

Dynamic Fog-Cloud Task Allocation Strategy for Smart City Applications

  • Salim, Mikail Mohammed;Kang, Jungho;Park, Jong Hyuk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.128-130
    • /
    • 2021
  • Smart cities collect data from thousands of IoT-based sensor devices for intelligent application-based services. Centralized cloud servers support application tasks with higher computation resources but introduce network latency. Fog layer-based data centers bring data processing at the edge, but fewer available computation resources and poor task allocation strategy prevent real-time data analysis. In this paper, tasks generated from devices are distributed as high resource and low resource intensity tasks. The novelty of this research lies in deploying a virtual node assigned to each cluster of IoT sensor machines serving a joint application. The node allocates tasks based on the task intensity to either cloud-computing or fog computing resources. The proposed Task Allocation Strategy provides seamless allocation of jobs based on process requirements.

A Study on Noise in Waste Facilities (폐기물 소각시설 내부 소음에 관한 연구)

  • Seo, Byung-Suk;Park, Ro-Gook;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

Vegetation Structure of Pedicularis ishidoyana Koidz. & Ohwi in South Korea Natural Habitats (한국 내 애기송이풀 자생지역의 식생구조)

  • Byun, Jun Gi;Cheon, Kwang Il;Oh, Seung Hwan;Lee, You Mi;Jang, Jeong Won;Joo, Sung Hyun
    • Korean Journal of Plant Resources
    • /
    • v.26 no.2
    • /
    • pp.214-226
    • /
    • 2013
  • The habitats characteristics of Pedicularis ishidoyana were investigated to provide basic data for conservation and restoration. The altitude ranged from 107m to 494m, with inclinations of $5{\sim}20^{\circ}$. As a result of vegetation survey within natural populations, a total of 243 taxa were identified 18 quadrates in 6 natural habitats. The importance value of Pedicularis ishidoyana is 13.2% based on the coverage and frequency of the herb layer with in the populations. NMS analysis, environmental impact of Pedicularis ishidoyana a decisive impact on the habitat factors, the species composition of the woody layer, rather than the species composition of the herb layer can say is more dominant. Preservation of habitat conditions is important for stable maintenance the flora, and the surrounding area including habitats has to be desegnated a protection area for habitats preservation.

Conservation of the Lacquered Sheath Excavated from Soochon-ri, Gongju, Korea (공주 수촌리 출토 칠기 칼집의 보존)

  • Lee, Yonghee;Yeon, Jeongah;Park, Junghae;Kim, Soochul
    • Conservation Science in Museum
    • /
    • v.14
    • /
    • pp.1-5
    • /
    • 2013
  • This study was conducted to analysis and conserve a lacquered sheath excavated from Soochon-ri, Gongju, Korea. The lacquered sheath was collected together with iron relics. The lacquered sheath was damaged and lost the parts by the external pressure. Many parts were adhered with the rust. Firstly, the object was understanded to have the relation with the iron materials excavated together through the X-ray photographs. As the analysis of the lacquer layers, the report conducted to a study the method of production. After the analysis of relic, the conservation treatment was performed for the stability of original shape. And we made the protection frame for the storage and exhibition.

Experimental Study of The Corrosion Protection Performance of The Metal Spraying Process in accordance with ratio of Zn-Al (Zn-Al의 구성비율에 따른 금속용사 공법의 방식성능에 대한 실험적 연구)

  • Kim, Hae;Eom, Sung-Hyun;Jeong, Hyun-Gyu;Lee, Jeong-Bae;Kim, Seong-Soo;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.26 no.2
    • /
    • pp.56-65
    • /
    • 2017
  • This study is an experimental study on the corrosion protection performance according to the configuration ratio of the Zn and Al. A metal spraying was used as the arc metal spraying method, a specimen was produced by varying the proportion ratio and coating thickness of the Zn and Al. Experimental methods visually observed to corrosion of the specimen for 1, 3, 7, 15 days was conducted in accordance with the CASS salt spray test. This study has confirmed that the performance of the corrosion protection improved against the increase in the Al content. Further, it was confirmed that excellent perfomance is exhibited when the coating thickness is secured over $80{\mu}m$. In addition, the SEM analysis was performed to observe the cross-sectional shape of the metal spraying specimen after CASS testing. The analysis result showed that the deterioration of the metal spraying coating layer was reduced as the Al content increases.

Test of Fault Detection to Solar-Light Module Using UAV Based Thermal Infrared Camera (UAV 기반 열적외선 카메라를 이용한 태양광 모듈 고장진단 실험)

  • LEE, Geun-Sang;LEE, Jong-Jo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.106-117
    • /
    • 2016
  • Recently, solar power plants have spread widely as part of the transition to greater environmental protection and renewable energy. Therefore, regular solar plant inspection is necessary to efficiently manage solar-light modules. This study implemented a test that can detect solar-light module faults using an UAV based thermal infrared camera and GIS spatial analysis. First, images were taken using fixed UAV and an RGB camera, then orthomosaic images were created using Pix4D SW. We constructed solar-light module layers from the orthomosaic images and inputted the module layer code. Rubber covers were installed in the solar-light module to detect solar-light module faults. The mean temperature of each solar-light module can be calculated using the Zonalmean function based on temperature information from the UAV thermal camera and solar-light module layer. Finally, locations of solar-light modules of more than $37^{\circ}C$ and those with rubber covers can be extracted automatically using GIS spatial analysis and analyzed specifically using the solar-light module's identifying code.

Establishment of Integrated Design Bases Management System of APR1400 Using BIM based Algorithm (BIM기반 Algorithm을 활용한 APR1400 설계기준 통합관리 체계 구축)

  • Shin, Jaeseop;Choi, Jaepil
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.5
    • /
    • pp.52-60
    • /
    • 2019
  • The APR1400 is a 1400MWe nuclear power plant developed through national technology development project over a period about 10years. Approximately 65,000 design drawings are produced for APR1400 construction. In order to maintain consistency among numerous drawings, the highest level of design bases drawings (DBDs) are created according to design bases and this is used in the subsequent design. However, DBDs are produced and managed on a document basis and they are managed various field, it was difficult to accurately reflect the design bases information in the subsequent design. Therefore, this study recognizes limitations of the document based DBDs and develops a system that can accurately reflect the design bases information to subsequent design by adopting BIM based design bases integrated information system. Especially, by introducing DBIL(Design Bases Information Layer) concept, DBIL was created and analyzed based on five design bases(Physical protection, Fire protection, Internal missile protection, Internal flood protection, Radiation protection) applied to APR1400. In the final result DBIL set and Datasheet are integrated of room, design bases information, building data(wall, slab, door, window, penetrations). So it can be used for subsequent design automation and design verification. Furthermore, it is expected that APR1400 DBILs data can be used extensively in constructability and design economics analysis through comparison with next generation nuclear power plant.