• Title/Summary/Keyword: Lateral velocity

Search Result 458, Processing Time 0.027 seconds

Modeling 2D residence time distributions of pollutants in natural rivers using RAMS+ (RAMS+를 이용한 하천에서 오염물질의 2차원 체류시간 분포 모델링)

  • Kim, Jun Song;Seo, Il Won;Shin, Jaehyun;Jung, Sung Hyun;Yun, Se Hun
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.7
    • /
    • pp.495-507
    • /
    • 2021
  • With the recent industrial development, accidental pollution in riverine environments has frequently occurred. It is thus necessary to simulate pollutant transport and dispersion using water quality models for predicting pollutant residence times. In this study, we conducted a field experiment in a meandering reach of the Sum River, South Korea, to validate the field applicability and prediction accuracy of RAMS+ (River Analysis and Modeling System+), which is a two-dimensional (2D) stream flow/water quality analysis program. As a result of the simulation, the flow analysis model HDM-2Di and the water quality analysis model CTM-2D-TX accurately simulated the 2D flow characteristics, and transport and mixing behaviors of the pollutant tracer, respectively. In particular, CTM-2D-TX adequately reproduced the elongation of the pollutant cloud, caused by the storage effect associated with local low-velocity zones. Furthermore, the transport model effectively simulated the secondary flow-driven lateral mixing at the meander bend via 2D dispersion coefficients. We calculated the residence time for the critical concentration, and it was elucidated that the calculated residence times are spatially heterogeneous, even in the channel-width direction. The findings of this study suggest that the 2D water quality model could be the accidental pollution analysis tool more efficient and accurate than one-dimensional models, which cannot produce the 2D information such as the 2D residence time distribution.

The Effects of Forest Healing Anti-aging Program on Physical Health of the Elderly: A Pilot Study (산림치유 항노화 프로그램이 노인의 신체적 건강에 미치는 효과: 예비연구)

  • Baek, Ji-Eun;Shin, Ho-jin;Kim, Sung-Hyeon;Kim, Jae Yeon;Park, Sujin;Sung, Si-Yoon;Cho, Hwi-young;Hahm, Suk-Chan;Lee, Min-Goo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.2
    • /
    • pp.81-90
    • /
    • 2021
  • PURPOSE: Aging causes a decrease in muscle mass and a change in posture, which reduces motor function and makes it difficult to perform daily activities independently. As these factors are closely related to the deterioration of the quality of life, it is very important to prevent and manage negative changes in the musculoskeletal system. Forest healing is a nature therapy course that maintains and promotes health using various environmental factors in a forest. The purpose of this study was to identify the effects of the forest healing anti-aging programs on the physical health of the elderly. METHODS: Ten elderly people participated in this study, as part of a forest healing anti-aging program for two days. Functional fitness, muscle strength, gait function, and balance were evaluated before and after the program. RESULTS: The number of arm curls, chair stands, and steps in a 2-min walk significantly increased (p < .05). 8-feet up & go time was significantly decreased (p < .05). Biceps brachii, quadriceps femoris, and calf muscle strength were significantly increased (p < .05). Gait velocity and cadence were significantly increased (p < .05). Step length, stride length, step time, swing time, stance time, and cycle time were significantly decreased (p < .05). Reaching distance in the lateral directions was significantly increased (p < .05). CONCLUSION: The forest healing anti-aging program improves the physical health of the elderly.

Effects of Dynamic Tubing Gait Training on Postural Alignment, Gait, and Quality of Life in Chronic Patients with Parkinson's Disease : Case Study (동적탄력튜빙 보행훈련 프로그램이 만성 파킨슨병 환자의 자세정렬과 보행능력과 삶의 질에 미치는 영향 : 사례연구)

  • Lee, Dong-Ryul
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.363-377
    • /
    • 2021
  • The present study investigated the effects of dynamic tubing gait training(I and II) on the postural alignment, gait, and quality of life in chronic patients with Parkinson's disease. This study is based on the case study that recruited a total of 3 patients with chronic Parkinson's disease (Hoehn and Yahr Stage of 1 to 3 each one person). Dynamic tubing gait training (I and II) applied to chronic patients with Parkinson's disease for 25 sessions, 30 minutes a day, 5 days a week, over 5 weeks period. To investigate the effects of this study, evaluating using the postural alignment test, muscle activity tests, gait analysis, and quality of life scale for patient with Parkinson's disease. After the intervention of Dynamic tubing gait training (I and II), Trunk flexion was decreased. Also, during walking from initial contact (IC) to mid stance (Mst), muscle activity of Quadriceps, Hamstring, and Tibialis Anterior (TA) was increased and muscle activity of Gastrocnemius was decreased. The muscle activation of Erector Spinae (ES T12, L3) was increased in the H&Y I and III stages and decreased in the H&Y II stage. Length of gait line, single support line, ant/post position and lateral symmetry of center of pressure (COP) parameters improved. The spatio-temporal gait parameters including of step length, stride length, and velocity was increased, and cadence decreased. Further the quality of life of patients with Parkinson's disease was improved. Based on these findings, Dynamic tubing gait training (I and II) could be applied as a new approach to improve posture, gait, quality of life in chronic patients with Parkinson's disease for more than 5 years, whose drug resistance is halved.

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

Comparison of Weighted Needle Pinprick Sensory Thresholds and Sensory Nerve Conduction Studies in Diabetic Patients (당뇨병 환자에서의 가중침자 감각역치와 감각신경 전도검사와의 비교)

  • Ryoo, Jae-Kwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.1
    • /
    • pp.929-941
    • /
    • 1996
  • This study was conducted to determine the association between weighted needle pinprick sensory threshold(PPT) and sensory nerve conduction studies. The subjects were 53 healthy controls, 31 diabetic patients without peripheral neuropathic symptoms(DM) and 36 diabetic patients with peripheral neuropathic symptoms(DN). PPT was measured on the index and little fingers, bilaterally, as well as under the lateral malleolus, bilaterally. In electrophysiologic assessment the left and right median, ulnar and sural nerves were studied. Mean PPT in DN, DM and controls was high in turn on each sites tested. Age controlled PPT was significantly different among three groups on right little finger(p<0.05) and left malleolus(p<0.05), but on other sites, not statistically significantly different between DN and DM. The results were as follows: Sensory nerve conduction velocity and amplitude on each nerve tested were statistically significantly different among three groups(p<0.05). Correlation of PPT with sensory nerve conduction velocity and amplitude were statistically significant on each site and ranged from -0.4203(left malleolus) to -0.5649(right index finger) and from -0.3897(left index finger) to -0.6200(right index finger), respectively. When electrophysiological study is not feasible, measurement of PPT may be helpful for the assessment of peripheral sensory neurological function.

  • PDF

Comparison of Weighted Needle Pinprick Sensory Thresholds and Sensory Nerve Conduction Studies in Diabetic Patients (당뇨병(糖尿病) 환자(患者)에서의 가중침자(加重針刺) 감각역치와 감각신경(感覺神經) 전도검사(傳導檢査)와의 비교(比較))

  • Yoo, Jae-Kwan;Kim, Seong-Ah;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.899-910
    • /
    • 1995
  • This study was conducted to determine the correlation between weighted needle pinprick sensory threshold(PPT) and sensory nerve conduction tests. The subjects were 53 healthy controls, 31 diabetic patients without peripheral neuropathic symptoms(DM) and 36 diabetic patients with peripheral neuropathic symptoms(DN). PPT was measured on the index and little fingers, bilaterally, as well as under the lateral malleolus, bilaterally. In electrophysiologic assessment the left and right median, ulnar and sural nerves were studied. Each mean PPTs was high in order of controls, DM and DN. Age adjusted PPT was significantly different among three groups on right little finger(p<0.05) and left malleolus(p<0.05), but not significantly different between DN and DM on other sites. Each sensory nerve conduction velocity and amplitude was statistically significantly different among three groups(p<0.05). Correlations of PPT with sensory nerve conduction velocity and amplitude were statistically significant on each site and ranged from -0.4203(left malleolus) to -0.5649(right index finger) and from -0.3897(left index finger) to -0.6200(right index finger), respectively. When electrophysiological study is not feasible, measurement of PPT may be helpful for the assessment of peripheral sensory neurological function.

  • PDF

4-Dimensional dose evaluation using deformable image registration in respiratory gated radiotherapy for lung cancer (폐암의 호흡동조방사선치료 시 변형영상정합을 이용한 4차원 선량평가)

  • Um, Ki Cheon;Yoo, Soon Mi;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.83-95
    • /
    • 2018
  • Purpose : After planning the Respiratory Gated Radiotherapy for Lung cancer, the movement and volume change of sparing normal structures nearby target are not often considered during dose evaluation. This study carried out 4-D dose evaluation which reflects the movement of normal structures at certain phase of Respiratory Gated Radiotherapy, by using Deformable Image Registration that is well used for Adaptive Radiotherapy. Moreover, the study discussed the need of analysis and established some recommendations, regarding the normal structures's movement and volume change due to Patient's breathing pattern during evaluation of treatment plans. Materials and methods : The subjects were taken from 10 lung cancer patients who received Respiratory Gated Radiotherapy. Using Eclipse(Ver 13.6 Varian, USA), the structures seen in the top phase of CT image was equally set via Propagation or Segmentation Wizard menu, and the structure's movement and volume were analyzed by Center-to Center method. Also, image from each phase and the dose distribution were deformed into top phase CT image, for 4-dimensional dose evaluation, via VELOCITY Program. Also, Using $QUASAR^{TM}$ Phantom(Modus Medical Devices) and $GAFCHROMIC^{TM}$ EBT3 Film(Ashland, USA), verification carried out 4-D dose distribution for 4-D gamma pass rate. Result : The movement of the Inspiration and expiration phase was the most significant in axial direction of right lung, as $0.989{\pm}0.34cm$, and was the least significant in lateral direction of spinal cord, as -0.001 cm. The volume of right lung showed the greatest rate of change as 33.5 %. The maximal and minimal difference in PTV Conformity Index and Homogeneity Index between 3-dimensional dose evaluation and 4-dimensional dose evaluation, was 0.076, 0.021 and 0.011, 0.0 respectfully. The difference of 0.0045~2.76 % was determined in normal structures, using 4-D dose evaluation. 4-D gamma pass rate of every patients passed reference of 95 % gamma pass rate. Conclusion : PTV Conformity Index was more significant in all patients using 4-D dose evaluation, but no significant difference was observed between two dose evaluations for Homogeneity Index. 4-D dose distribution was shown more homogeneous dose compared to 3D dose distribution, by considering the movement from breathing which helps to fill out the PTV margin area. There was difference of 0.004~2.76 % in 4D evaluation of normal structure, and there was significant difference between two evaluation methods in all normal structures, except spinal cord. This study shows that normal structures could be underestimated by 3-D dose evaluation. Therefore, 4-D dose evaluation with Deformable Image Registration will be considered when the dose change is expected in normal structures due to patient's breathing pattern. 4-D dose evaluation with Deformable Image Registration is considered to be a more realistic dose evaluation method by reflecting the movement of normal structures from patient's breathing pattern.

  • PDF

Egg Development and Morphological Change of Larvae and Juveniles, Characteristics of Spawning Sites of the Korean Endemic Species, Coreoleuciscus splendidus (Cypriniformes: Gobioninae) in the Jo-jong Stream, Korea (조종천에 서식하는 한국고유종 쉬리 Coreoleuciscus splendidus (Cypriniformes: Gobioninae)의 난발생, 자치어 형태 발달 및 자연산란장 연구)

  • Song, Ha-Yoon;Kim, Seung-Yong;Kim, Kyeong-Mu;Kwak, Young-Ho;Jeon, Hyoung-Joo
    • Korean Journal of Ichthyology
    • /
    • v.32 no.3
    • /
    • pp.166-181
    • /
    • 2020
  • The egg development, early life history and spawning site characters of Korean endemic fish, Coreoleuciscus splendidus (Gobioninae), were investigated at the part of Jo-jong stream in Korea from May 2020. The fertilized eggs were 2.05~2.23 mm (mean, 2.13 mm) in diameter and had no oil globules. The embryo began to hatching about 98 hrs after fertilization under water temperature of 20±1℃. The newly-hatched larvae were 5.03~5.68 mm (mean, 5.31 mm) in total length (TL), and their mouth and anus were not opened. 4 days after hatching, Several rod-like cupulae were observed on the head and lateral side of the body at 6.95~7.89 mm (mean, 7.51 mm). 7 days after hatching, the post-larva stage were 8.39~9.29 mm (mean, 8.78 mm) in total length, and their york were completely absorbed. The cupulae were completely distinguished. They entered the juvenile stage when all fin-rays were formed at 29 days after hatching, and their TL were 14.16~17.04 mm (mean, 14.99 mm). Squamation was initiated on the caudal body at approximately 18.21~23.74 mm (mean, 30.28 mm), 38 days after hatching, and completed at 26.82~33.33 mm (mean, 19.42 mm), 73 days after hatching, the external characteristics from of juveniles were same to adults. The spawning site was characterized by bottom structure of pebble (64~16 mm) and gravel (16~2 mm), environmental conditions of the spawning sites were 6~18 cm in water depth, 0.43~0.73 m/sec in bottom water velocity. In spawning sites, an egg mass or separated eggs were located a small gap of under the pebble and gravel.