• Title/Summary/Keyword: Lateral pressure

Search Result 917, Processing Time 0.026 seconds

Influences of the Defective Piezo-Elements of a Medical Ultrasonic Probe on Transient Acoustic Fields and B-Mode Images (의료용 초음파프로브의 압전소자 결함이 과도음장과 B-모드 영상에 미치는 영향)

  • Choi, Kwang-Yoon;Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Soon;Yang, Jeong-Hwa;Kang, Gwan-Suk;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.476-482
    • /
    • 2010
  • The ultrasonic transient fields and B-mode images of a point target which were simulated for a medical ultrasonic probe with a few defective piezo-elements were compared with those for a normal probe. The present study considered a 3.5 MHz linear array probe whose acoustic beam was formed by the 64 active elements of total 192 elements. The results showed that the maximum amplitude and -3 dB width of the acoustic fields by main-lobes decreased linearly as the defective element number increased from one to four. However, the depths of foci remained almost unchanged, and the pressure differences between main-lobes and side-lobes tended to decrease due to rise in pressures in side-lobes. Such changes in ultrasonic fields affected the B-mode images of point targets. So the artifacts were formed in the right and left side of the target, and the lateral spatial resolutions were decreased while the axial resolution was almost the same.

Dynamic Postural Control and Ankle Joint Laxity among Dancers and Non-dancers with Chronic Ankle Instability, and Healthy Dancers (만성 발목 불안정성을 가진 무용수와 비무용수, 건강한 무용수의 동적 자세 조절 및 발목 관절 이완성)

  • Eun Ji Hong;Jiho Kang;Hyung Gyu Jeon;Kyeongtak Song;Sae Yong Lee
    • Korean Journal of Applied Biomechanics
    • /
    • v.34 no.2
    • /
    • pp.93-103
    • /
    • 2024
  • Objective: The purpose of this study was to investigate whether dancers with chronic ankle instability (CAI) exhibit different characteristics in dynamic postural control ability and ankle joint laxity compared to dancers without CAI and non-dancers with CAI. Method: Twelve dancers with CAI, 14 dancers without CAI, and 12 non-dancers with CAI participated in the study. Dynamic balance was evaluated using the Star Excursion Balance Test (SEBT) and the single-leg hop balance. The laxity of the ankle joint was evaluated through the anterior drawer test and the talar tilt test. SEBT measured maximum reach distances in anterior, posteromedial, and posterolateral directions. Single-leg hop assessed center of pressure (COP) and time-to-boundary (TTB) outcomes. One-way ANOVA and Chi-square tests were performed to compare the outcome variables among the three groups. Results: Dancers with CAI demonstrated greater reach distance in the posterolateral direction compared to non-dancers with CAI during SEBT (p=.014). Secondly, dancers without CAI showed greater reach distance in the posterolateral (p<.001) and posteromedial (p=.001) directions during SEBT compared to non-dancers with CAI. Additionally, dancers without CAI exhibited better postural control with higher TTB AP mean of minima (p=.003) and TTB AP standard deviation of minima (p=.012) during single-leg hop compared to nondancers with CAI. Thirdly, dancers with CAI showed a lower positive rate during the anterior drawer test compared to non-dancers with CAI (p=.019). Conclusion: Dancers with CAI demonstrated better ankle function and reduced mechanical instability compared to non-dancers with CAI. Therefore, to elucidate the underlying mechanisms of lateral ankle sprain and CAI development exacerbation in dancers, additional factors that can affect ankle sprain, such as visual dependence during postural control and evaluation in dance movements, should be explored.

Relationship of Follow-through Movements to Target Accuracy in Compound Archers (컴파운드 양궁의 팔로우 스루 동작과 사격 정확도의 상관관계)

  • Junkyung Song;Kitae Kim
    • Korean Journal of Applied Biomechanics
    • /
    • v.34 no.1
    • /
    • pp.34-44
    • /
    • 2024
  • Objective: This study aimed to investigate how the movements occurring during the follow-through phase after releasing an arrow among elite compound archers, are associated with the arrow impact points on the target. Method: Nine elite archers performed consecutive compound archery shooting under conditions identical to actual competitions using their own bows and equipment. Motion capture system and force platform were utilized to record the changes in joint positions and center of pressure, respectively. Principal component analysis was employed to identify the patterns in which multidimensional joint positions and COP changes were organized with horizontal and vertical coordinates of arrow impact points. Subsequently, correlation analysis quantified the relationship between individual variables and the coordinates of arrow impacts on the target. Results: We found a common organizational pattern in which the two axes of the impact point coordinates were grouped into the first two principal components. The movements of the upper and lower limbs following release exhibited opposite patterns in the anterior-posterior axis, with significant correlations observed between the arrow impact points of the horizontal axis and the left shoulder, right elbow, left hip, and both knees. Additionally, the lateral movements induced by the reaction force upon arrow release showed significant associations with the vertical coordinates of the impact points. Particularly, the correlations between the movements of the left shoulder and elbow, as well as the bilateral hip and right knee, were consistently observed among all participants. Conclusion: These findings implied that the post-release movements could significantly influence the trajectory and impact points of the arrows in compound archery. We suggest that a consistent and controlled movement during the follow-through phase may be more beneficial for optimizing shooting accuracy and precision rather than minimizing movements.

A Behavior of Curve Section of Reinforced Retaining Wall by Model Test (모형실험을 통한 보강토 옹벽 곡선부 거동특성)

  • Ki, Jung Su;Rew, Woo Hyun;Kim, Sun Kon;Chun, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.249-257
    • /
    • 2012
  • The reinforced earth method is financially viable. Furthermore, it overcomes environmental limitations and is therefore employed in retaining walls, slopes, foundations, roads, embankments, and other structures. However, in some cases, reinforced retaining walls are not strong enough in the curved sections and can collapse. Such mishaps are believed to occur because of an unsatisfactory analysis of the curved sections of a reinforced retaining wall. Accordingly, with the aim of investigating the workability and structural safety of curved sections of various types, this study investigates the differences in the estimated horizontal displacements of curved sections of various types and subsequently uses this information to study and analyze preliminary data so that appropriate measures can be taken to resolve alignment issues. The results of an experiment reveal that when a load is applied to curved sections of both concave and convex types, the largest horizontal displacement occurs at the center of the section. In the concave form, the earth pressure force is directed inward, whereas in the convex form, this force is directed outward. As a result, the horizontal displacement in convex forms is larger than that in concave forms. Convex reinforced earth structures are subjected to earth pressures as well as lateral earth pressure, therefore horizontal displacements in convex curved sections is larger than that of concave curved sections.

The Effect of Foot Strengthening Exercise to Young of Hallux Valgus with Flexible Flatfoot (발 강화 운동이 유연성 편평발이 동반된 엄지발가락가쪽휨증을 가진 젊은 성인에게 미치는 효과)

  • Park, Jin-Hyun;Kim, Jin-Seop;Kim, Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5211-5217
    • /
    • 2012
  • This study was to evaluate the effects of foot strengthening exercise to improve hallux valgus in young of hallux valgus with flexible flatfoot. Subjects 28 people were randomly divided by the foot strength group(n=14) and control group(n=14). In a period of 8 weeks, they put on I.D.W. Experimental group took foot strengthening exercise for 20 minutes 3 times a week during 8 weeks. Foot structure and max pressure were evaluated by hallux angle, 1~2 metatarsal angle, navicular height, 1st phalange, 2~5phalange, 1st metatarsal, 2nd metatarsal, 3rd metatarsal, 4th metatarsal, 5th metatarsal, mid foot, medial hind foot, lateral hind foot. There were significantly increased by exercise group in outcomes of the structural and plantar foot pressure from hallux angle, 1~2 metatarsal angle, 1st phalange, 1st metatarsal, 2nd metatarsal, 3rd metatarsal, mid foot. The result suggest that foot strengthening exercise is feasible and suitable for individuals with hallux valgus with flexible flatfoot.

A Study on Evaluation of Field Applicability of Flexible Waterproofing Material with High Adhesion Using Reclaimed Natural Latex (천연 라텍스 재생고무를 활용한 고점착형 시트 방수재의 현장 적용성 평가 연구)

  • Oh, Sangkeun;Jo, Ilkyu;Kim, Jinsung;Kim, Dongbum;Lee, Jongyong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.25-32
    • /
    • 2013
  • This study has been conducted in order to propose Eco-friendly and High functional waterproofing technology available for structure by verifying application and performance of water proofing material(s) in purpose of making effective use of reclaimed rubber. As s result of 12 months evaluation, stable performance for water pressure and lateral pressure of $0.3N/mm^2$ were confirmed. Also, as the time elapsed, the amount of water absorption and adhesion performance showed only a slight difference(+0.05g, $-0.1Nmm^2$) as well, which in turn confirmed that waterproofing performance remains stable. Studies show that it is expected to expand recycling technology of natural rubber by applying reclaimed rubber on construction waterproofing field, and to hold a technical superiority by using eco-friendly material in construction waterproofing market throughout active application of these types of research.

  • PDF

Microclimatological Characteristics Observed from the Flux Tower in Gwangneung Forest Watershed (플럭스 타워에서 관측된 광릉 산림 소유역의 미기후학적 특징)

  • Choi Taejin;Lim Jong-Hwan;Chun Jung-Hwa;Lee Dongho;Kim Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.35-44
    • /
    • 2005
  • Microclimate of Gwangneung forest watershed is characterized by analyzing wind, radiation, profiles of air temperature and humidity, soil and bole temperature, precipitation and soil water content measured at and around the flux tower from April 2000 to September 2003. Mountain-valley wind was prevalent due to the topographic effect with dominant wind from east during daytime and relatively weak wind from west during nighttime. Air temperature reaches its peak in July-August whereas monthly-averaged incoming shortwave radiation shows its peak in May due to summer monsoon. Albedo ranges from 0.12 to 0.16 during the growing season. Monthly-averaged bole temperature is in phase with monthly- averaged air temperature which is consistently higher. Monthly-averaged soil temperature lags behind air temperature and becomes higher with leaf fall. With the emergence of leafage in April, maximum temperature level during midday shifts from the ground surface to the crown level of 15-20m in May. Profiles of water vapor pressure show a similar shift in May but the ground surface remains as the major source of water. Vapor pressure deficit is highest in spring and lowest in winter. Monthly averaged surface soil temperatures range from 0 to 20℃ with a maximum in August. Monthly averaged trunk temperatures of the dominant tree species range from -5.8 to 21.6℃ with their seasonal variation and the magnitudes similar to those of air temperature. Annual precipitation amount varies significantly from year to year, of which >60% is from July and August. Vertical profiles of soil moisture show different characteristics that may suggest an important role of lateral movement of soil water associated with rainfall events.

Change of Somatosensory Evoked Field Potential according to the Severity of Hydrocephalus in Kaolin-induced Hydrocephalus of Rats (수두증 흰쥐 모델에서 수두증 정도에 따른 체성 감각 유발 장전위의 변화)

  • Kim, Dong-Seok;Lee, Kwang-Soo;Park, Yong-Goo;Kim, Se-Hyuk;Choi, Joong-Uhn;Lee, Bae-Hwan;Ryou, Jae-Wook;Zhao, Chun-Zhi
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.5-14
    • /
    • 2000
  • Objective : Somatosensory evoked potential(SSEP) has been known to be a good method for evaluating brain stem function, but it is not sufficient to check the fine changes of cortical functions. A fine change of cortical function can be expressed with somatosensory evoked cortical field potential(SSEFP) rather than general SSEP. To confirm the usefulness of SSEFP for evaluating the cortical function, the authors simultaneously measured SSEFP and the intracranial pressure-volume index(PVI) in kaolin-induced hydrocephalic rats. Method : Hydrocephalus was induced with injection of 0.1ml kaolin-suspended solution into the cisterna magna in 60 Sprague-Dawley rats. The authors measured PVI and SSEFP 1 week after injection of kaolin-suspended solution. To evaluate the severity of induced hydrocephalus, we measured the transverse diameter of the lateral ventricle on the coronal slice of the rat brain 0.40mm posterior to the bregma. Result : The typical wave form of SSEFP in control rats showed a negative-positive complex wave at early latency. In SSEFP of normal rats, N0 is 10.0 msec, N1 15.3 msec, P1 31.2 msec and N1-P1 amplitude $15.4{\mu}V$. As hydrocephalus progressed, the peak latency of N1 and P1 were delayed. In mild hydrocephalus, negative peak waves were split. The N1-P1 amplitude was decreased only in severe hydrocephalus. The changes of the characteristics of SSEFP according to the severity of hydrocephalus were well correlated with the changes of PVI. Shunting normalized the characteristics of SSEFP in relation to ventricular sizes and PVI in hydrocephalic rats. Conclusion : SSEFP may be useful for evaluating the impairment of cortical function in hydrocephalus.

  • PDF

Electrocardiographic Findings of a Community People by Computerized Device for Analysis (일부지역 주민의 자동판독 심전도기에 의한 이상소견 연구)

  • Koo, E-Sun;Kim, Jae-Young;Kim, Hae-Joon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.2 s.61
    • /
    • pp.183-198
    • /
    • 1998
  • In order to determine the prevalence rate and find out the sexual difference of abnormal electrocardiographic findings manifested by computerized EKG, which is equipped with auto-analyzing function, a total of 2,083 electrocardiograms that were taken from population over 20 years-old from October 1996 to February 1997 were studied according to their age, gender and blood pressure. 1. Using the electrocardiography with auto-analyzing function, 33 kinds of abnormal findings were manifested. The prevalence rate of abnormal findings was 52.8% in male and 43.7% in female. Among them, the most common finding was sinus brady-cardia found in 17.6% of male and 15.4% of female. Left ventricular hypertrophy by voltage criteria, minimal voltage of left ventricular hypertrophy, left axis deviation and atrial fibrillation were more common in male than in female statistically. Both of nospecific T wave and ST segment abnormality were more common in female than in male statistically. 2. Thirty-three kinds of abnormal findings were manifested. They revealed one abnormal finding alone or combined with some other ones making 128 kinds of abnormal finding. The most common abnormal finiding that manifested alone was right axis deviation (100%), then myocardial ischemia (95.7%) the next. The most common abnormal finding that complexed with other abnormal findings were left anterior fascicular block(percentage of single manifestation, 26.2%) and nonspecific T wave abnormality(percentage of single manifestation; 32.9%). Also, combination of sinus bradycardia and minimal voltage of left ventricular hypertrophy, and combination of sinus bradycardia and left ventricular hypertrophy were included in 25th sequences of abnormal findings. 3. The prevalence rate of abnormal electrocardiographic findings were higher in older group, hypertensive group, and the group of higher systolic or diastolic pressure in both sexes. 4. Abnormal findings that commonly manifested with sinus bradycardia were voltage criteria or minimal voltage of left ventricular hypertrophy(38.6%): sinus arrhythmia(10.5%): nonspecific T wave or ST segment abnormality(18.4%) and first degree AV block(7.2%) in descending order. 5. The most common site which manifested myocardial ischemia was posterior and inferior wall with equal percentage of 23.4%. And then anterior wall(19.1%), and antero-lateral wall and septum with equal percentage of 10.6% was noted in descending order.

  • PDF

Analysis of the Structural Safety of a Wind-Protecting Wall Using ANSYS/CFX (ANSYS와 CFX를 이용한 방풍벽의 구조 안전성 분석)

  • Yum Sung-Hyun;Kim Chul-Soo;Choi Young-Don
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.138-148
    • /
    • 2006
  • This study was carried out to evaluate the structural safety fur both the attached wind-protecting wall in greenhouse and the detached one installed outside. Regarding the attached wind-protecting wall in greenhouse, the analysis was conducted by doing a fluid-structure coupled field analysis using both CFX-5.7 and ANSYS 8.1 and also under the design condition of an instantaneous maximum wind velocity of $30.9m{\cdot}s^{-1}$. Three kinds of the width ranged from 30 to 90cm were considered in this study. With regard to the detached wind-protecting wall, the structural saffty was analyzed under the pressure difference of 1,117 Pa which corresponded to a wind velocity of $50m{\cdot}s^{-1}$ and the analytical results were also compared with theoretical ones. The result showed that there was little difference in the distribution of velocity overall and total pressure on the lateral side according to the width of the attached wind-protecting wall, but greenhouse with wind-protecting widths of 30 to 60cm has been reinforced to the extent of about 11% when compared with the case of being without the wall. The result also showed that the detached wind-protecting wall with a main-column interval of 3m was not stable so that it was necessary for the detached wind-protecting wall to be adequately reinforced to secure structural stability. Finally, there was great difference between analytical results and theoretical studies. The difference meant that there was some possibility of including errors when a theoretical study was done in three dimensional structure.