• Title/Summary/Keyword: Lateral deviation

Search Result 248, Processing Time 0.026 seconds

An Electromyographic Study on the Edentulous Patients (E.M.G를 이용한 무치악에서의 저작근에 대한 연구)

  • 이승우
    • Journal of Oral Medicine and Pain
    • /
    • v.2 no.1
    • /
    • pp.8-16
    • /
    • 1974
  • The author performed electromyographic analysis on edentulous patients aging 52 to 77 who have upper and lower full dentures for 3 to 7 years of duration. And the graphs were recorded in physiologic rest position, incisal occlusion, molar occlusion, left lateral excursion, right lateral excursion and mandibular projection. The results obtained are as follows : 1. 80 per cent of the patients are in unilateral mastication. 2. The shorter history of edentulous mouth reveals the more electric potency. 3. Facial deviation owing to unilateral mastication is the cause of higher electric potency to the deviated site. 4. There were no difference in electric potency between mandibular projection and incisal occlusion.

  • PDF

Reliability Analysis on the Decision Method of Lateral Flow of Foundation Piles for Abutment (교대 기초말뚝의 측방유동 판정식에 관한 신뢰성 해석)

  • Ahn, Jong-Pil;Kim, Gyu-Deok;Kim, Il-Goo;Choi, Jin-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1090-1097
    • /
    • 2008
  • This study conducted the decision method of lateral flow in abutment structures founded on the soft soils and the reliability analysis on the foundation pile for abutment. On the basis of the results, this study proposed the reliability design model. Reliability analysis was conducted by applying second moment method, point estimation method, and expected total cost minimization to lateral movement index, lateral movement decision index, modified lateral movement decision index, and circular failure safety factor for the decision criteria of lateral flow. The reliability index by analysis method had a similar tendency each other. Point estimation method was found as a practical method in the aspect of convenience because it could conduct the analysis only by mean and standard deviation as well as the partial derivative on random variables was not necessary. Optimum reliability index and optimum safety according to increasing in failure factors and load ratio were analyzed and loads and resistance factors of the design criteria of optimum reliability were estimated. It presented rational design model which can consider construction level and stability and economical efficiency overall.

  • PDF

RELATIONSHIPS BETWEEN MANDIBULAR LATERAL DEVIATION AND MORPHOLOGY OF THE CRANIAL VAULIT (안면비대칭 환자에서 하악의 측방변위와 두개관형태 사이의 연관성)

  • Shin, Shang-Wook;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.594-606
    • /
    • 1996
  • This study was intended to perform the relationships between mandibualr lateral deviation in facial asymmetry patients and morphology of the cranial vault. In 30 patients(males 14, female 16) using submento-vertical cephalograms that were taken in the pre-operaticve state and posteroanterioir cephalograms that were taken in centric occlusion before, immediate and long term after surgery. 1. Mean mandibular deviation was about $-3.12^{\circ}$and mean of absolute measurement was about $2.50^{\circ}$on the submento-vertical cephalograms. 2. On the submento-vertical cephalograms, there was no significant difference between non-deviation and deviation side but it had tendency that deviation side was larger than non-deviation side on the frontal portion of cranium(Y10 to Y6) and deviation side was smaller than non-deviation on the temporal portion of cranium(Y5, Y-1 to Y-5). 3. Mean mandibular deviation was about $1.40^{\circ}$and mean of absolute measurement was about $3.95^{\circ}$on the posteroanterioir cephalograms. 4. There was statistical significance on the influence of surgical change(PT2A-PT1A) to the relapse(PTLA-PT2A)(p<0.05). The more increasing of the change, the more relapse on the posteroanterioir cephalograms. 5. There was no statistical significance on the influence of degree of mandibular deviation to morphology of the cranium on the submento-vertical cephalograms. But it had tendency that the more mandibular deviation, the larger the non-deviation side on the anterior cranium and deviation side on the posterior cranium(p>0.05). 6. There was statistical significance on the influence of the degree of mandibular deviation on the posteroanterioir cephalograms to the difference between non-deviation and deviation side. The more increasing of mandibular deviation, the larger the non-deviation side on the Y4 to Y-6(p<0.05). 7. There was no statistical significance on the influence of difference between non-deviation and deviation side to the relapse on the posteroanterioir cephalograms. But it had tendency that the more increasing of the differece between non-deviation and deviation side, the more increasing the relapse on temporal of cranium.

  • PDF

Radiologic Evaluation of Proper Pedicle Screw Placement after Pedicle Screw Fixation in Degenerative Lumbar Disc Disease

  • Ju, Sun-Min;Kim, Young-Soo;Kim, Sung-Bum;Ko, Yong;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.265-268
    • /
    • 2005
  • Objective : With the increasing popularity of pedicle screw fixation devices for several indications, the safety and reliability of screw insertion in the small pedicle has become a major issue. Many studies have investigated the accuracy of screw placement after pedicle screw fixation using various method. The reported displacement rates have been very different. The purpose of the study is to investigate the proper placement of pedicle screw insertion in the lumbar spine on 26 consecutive patients. Methods : Between September and December 2003, 26 consecutive patients [16women and 10men] were analyzed after transpedicular screw fixation of the lumbar and lumbosacral spine. After pedicle screw fixation in this study, 2-mm slices of CT scan were performed in all patients to detect caudal and cranial deviation of screw and medial and lateral deviation. Pedcile screw placement related complication was evaluated clinically. Results : A total of 144 inserted pedicle were analyzed in 26patients, and 58pedicle screws [40.3%] were detected to be improper placement. There were 14level [9.0%] of caudal or cranial deviation and 44level [30.6%] of medial or lateral deviation to the pedicle. Extra-pedicle placement was found on 4levels [2.7%] with only lease of neurologic injury. Conclusion : Proper screw placement, though complication rate is low, is important not only for clinical symptom but also for biomechanics. Further study for screw placement related biomechanical changes is needed.

Complications of the Nasal Bone Fractures according to the Stranc Classification (Stranc 분류법에 따른 비골골절 정복술 후 합병증)

  • Lee, Jun-Ho;Park, Won-Yong;Nam, Hyun-Jae;Kim, Yong-Ha
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.62-66
    • /
    • 2008
  • Purpose: Although nasal fractures are often discussed as minor injuries but the incidence of post-traumatic nasal deformity remains high. For decrease the incidence of post-traumatic nasal deformity which require the guideline to optimize the management of acute nasal bone fracture. The aim of this study is analysis of post-traumatic nasal deformity according to Stranc classification. Method: We reviewed 310 patients with nasal bone fracture treated at our hospital from January of 2005 to December of 2006. Result: Post-traumatic complication were divided septal deviation, nasal bone deformity, temporary hyposmia and synechia. Nasal bone deformity include nasal bone deviation, hump, flat nose and minimal nasal bone irregularity. The incidence of total complication rate was 36.4%. The most common complication was nasal deformity(22.9%) followed by septal deviation(19.7%). The most common complication was septal deviation(20%) in frontal impact. The most common complication was nasal deformity(19.5%) in lateral impact. In frontal impact, the incidence of complication rate was plane II(68.8%) followed by plane I(29.9%) and plane III(16.7%). In lateral impact, the incidence of complication rate was plane II (78.8%) followed by plane III(61.5%) and plane I(42.7%). Conclusion: This result can be used to improve longterm results and to reduce the incidence of post-traumatic nasal deformity by predict complication of nasal bone fracture according to Stranc classification.

Driving Performance Evaluation Using Foot Operated Steering System in the Virtual Driving Simulator (가상 운전 시뮬레이터를 이용한 족동 조향 시스템의 운전 성능 평가)

  • Song, Jeongheon;Kim, Yongchul
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.197-204
    • /
    • 2017
  • The aim of this study was to evaluate driving performance of normal subjects for controlling the steering wheel by using foot operated steering devices in the driving simulator. Many people with complete bilateral loss or loss of use of upper limbs but with normal lower limbs are frequently left without use and/ or control of their hands, arms, or the upper extremities of their bodies. As a result, persons disabled in this manner have problems in operation an automobile because they cannot grasp and manipulate a conventional steering wheel. Therefore, if foot operated steering devices are used for controlling the vehicle on in people with disabilities, the disabled people could improve their community mobility by driving a car safely. Ten normal subjects were involved in this research to evaluate steering performance by using three types of steering devices(conventional steering wheel, pedal type foot steering, circular type foot steering) in driving simulator. STISim Drive 3 program was used for testing the driving performance in two road scenarios: straight road and curved road at low and high speed of vehicle (40 km/h and 80 km/h). This study used two-way ANOVA to compare the influences of two factors(type of foot steering device and road scenario) in the three dependent variables of steering performance(standard deviation of lateral position, the lateral position of vehicle and the number of line crossing). The average values of the three dependent variables(standard deviation of lateral position, lateral position and the number of line crossing) of driving performance were significantly smaller for conventional steering wheel or pedal type foot steering than circular type foot steering.

Influence of Four Types of Steering Assistive Devices on Driving Performance: Comparison of Normal and Disabled People with and without Driver's License (4가지 선회보조 장치가 운전 성능에 미치는 영향: 장애 유무와 운전면허 유무에 따른 비교)

  • Song, Jeongheon;Kim, Yongchul
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.32-42
    • /
    • 2017
  • The aim of this study was to evaluate driving performance of Healthy and disabled groups (with or without driver's license) to control steering wheel by using steering assistive devices in the driving simulator. The persons with partial loss of use of all four limbs have problems in operation of the motor vehicle because of functional loss to operate steering wheel. Therefore, if steering assistive devices for grasping the steering wheel are used to control the vehicle on the road in persons with disabilities, the disabled persons can improve mobility in their community life by driving a motor vehicle safely. Ten healthy subjects (with or w/o driver's license) and ten subjects with physical disabilities (with or w/o driver's license) were involved in this study to evaluate driving performance to operate steering wheel by using four types of steering assistive devices (Single-pin, V-grip, Palm-grip, Tri-pin) in driving simulator. STISim Drive 3 software was used to test the steering performance in four scenarios: straight road at low and high speed of vehicle (40 km/h and 80 km/h), curved road at low and high speed of vehicle (40 km/h and 80 km/h). This study used two-way ANOVA in order to compare the effects of two factors (type of steering assistive device and subject group) in the three dependent variables of driving performance (the lateral position of vehicle, standard deviation of lateral position representing the variation of the left and right movement of the vehicle and the number of line crossing). The mean values of the three dependent variables (lateral position, standard deviation of lateral position, the number of line crossing) of steering performance were statistically significantly smaller for the healthy or disabled groups with driver's license than the other groups without driver's license on the curved road at high speed of vehicle compared to low speed of vehicle.

Horizontal change of philtrum after orthognathic surgery in patients with facial asymmetry

  • Joh, Yewon;Park, Hyun Soo;Yang, Hoon Joo;Hwang, Soon Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.48.1-48.7
    • /
    • 2019
  • Background: Soft tissue asymmetry such as lip canting or deviation of the philtrum is an important influencing factor for unbalanced facial appearance. Lip canting could be improved by the correction of the occlusal canting or positional change of the mentum. Although there are many studies about changes of lip canting, however, postoperative changes of philtrum deviation have not been yet reported. In this study, we investigate the positional change of the philtrum after orthognathic surgery and influencing factors. Methods: Positional change of the philtrum was evaluated in 41 patients with facial asymmetry who underwent bimaxillary surgery, in relation to other anatomical soft tissue landmarks using a frontal clinical photo. The surgical movement of the maxillary and mandibular dental midline and canting were measured in postero-anterior cephalogram before and 1 day after surgery. The same procedure was repeated in patients with more than 1.5 mm perioperative change of the mandibular dental midline after bimaxillary surgery. Results: Maxillary dental midline shifting and canting correction did not have a significant correlation with lateral movement of the philtrum midline. However, the mandibular shift had a statistically significant correlation with a lateral movement of the philtrum (p < 0.05) as well as other linear parameters and angle values. Conclusion: The horizontal change of the philtrum is influenced by lateral mandibular movement in patients with facial asymmetry, rather than maxillary lateral movement.

Prediction of Thermal Load Distribution and Temperature of the Superheater in a Tangentially Fired Boiler (접선 연소식 보일러의 최종 과열기 열부하 분포 및 튜브 온도 예측에 관한 연구)

  • Park, Ho-Young;Sea, Sang-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.478-485
    • /
    • 2008
  • The extreme steam temperature deviation experienced in the superheater of a tangentially fired boiler can seriously affect its economic and safe operation. This temperature deviation is one of the main causes of boiler tube failures. The steam temperature deviation is mainly due to the thermal load deviation in the lateral direction of the superheater. The thermal load deviation consists of several causes. One of the causes is the non-uniform heat flow distribution of burnt gas on the superheater tube system. This distribution is very difficult to measure in situ using direct experimental techniques. So, we need thermal load model to estimate the tube temperature. In this paper, we propose a thermal load distribution model by using CFD analysis and plant data. We successfully predict the tube temperature and the steam flow rate in a final superheater system from the thermal load model and one dimensional heat-flow system analysis. The proposed model and analysis method would be valuable in preventing the frequent tube failure of the final superheater tubes.

Electron spin relaxation control in single electron QDs

  • Mashayekhi, M.Z.;Abbasian, K.;Shoar-Ghaffari, S.
    • Advances in nano research
    • /
    • v.1 no.4
    • /
    • pp.203-210
    • /
    • 2013
  • So far, all reviews and control approaches of spin relaxation have been done on lateral single electron quantum dots. In such structures, many efforts have been done, in order to eliminate spin-lattice relaxation, to obtain equal Rashba and linear Dresselhaus parameters. But, ratio of these parameters can be adjustable up to 0.7 in a material like GaAs under high-electric field magnitudes. In this article we have proposed a single electron QD structure, where confinements in all of three directions are considered to be almost identical. In this case the effect of cubic Dresselhaus interaction will have a significant amount, which undermines the linear effect of Dresselhaus while it was destructive in lateral QDs. Then it enhances the ratio of the Rashba and Dresselhaus parameters in the proposed structure as much as required and decreases the spin states up and down mixing and the deviation angle from the net spin-down As a result to the least possible value.